• 제목/요약/키워드: X-ray unit

검색결과 563건 처리시간 0.026초

Characterization of the biodegradable behavior for biphasic calcium phosphates using X-ray diffraction and lattice parameter (X-선 회절 및 격자 매개변수를 이용한 biphasic calcium phosphate 분말의 생분 해성 특성평가)

  • Kim, Dong-Hyun;Song, Chang-Weon;Kim, Tae-Wan;Jin, Heoyng-Ho;Park, Hong-Chae;Yoon, Seog-Young
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • 제21권4호
    • /
    • pp.169-174
    • /
    • 2011
  • Nanoscale-biodegradable behaviors of synthesized biphasic calcium phosphates (BCP) powders were characterized using X-ray diffraction (XRD), lattice parameter, and field emission microscopy (FE-SEM). The calcined BCP powders in vitro tested in Hank's balanced salt solution (pH = 7.4, $36.5^{\circ}C$) for 3 weeks. The calculated unit cell parameters for BCP have shown lattice distortion and expansion as irregular changes in the a and c-axis after in vitro.

Evaluation of the Reproducibility of Radiation Output from Diagnostic X-ray Equipment(Standards Based on IEC 60601-2-54) (진단용 X선 장치에서 방사선출력의 재현성 평가(IEC 60601-2-54 표준규격을 기반으로))

  • Han, Beom-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan;Kim, Chong-Yeal;Lee, Sang-Ho;Han, Sang-Hyun;Hong, Dong-Hee;Kim, Chang-Gyu;You, In-Gyu;Mo, Eun-Hee
    • Journal of Digital Convergence
    • /
    • 제12권2호
    • /
    • pp.555-561
    • /
    • 2014
  • For five diagnostic X-ray generators (DR), four units turned out to be appropriate in tests on the reproducibility of radiation output suggested in the IEC 60601-2-54 standard, but in one unit of the X-ray equipment, an item measured in a combination of 50% of the highest tube voltage of the diagnostic X-ray equipment, the test setting of Group C with authorized output doses between $1{\mu}Gy$ and $5{\mu}Gy$ of mAs turned out to be inappropriate. As a result, the radiation dose to the IEC 60601-2-54 standard for quantification standards proposed by the radiation output from diagnostic X-ray imaging device reproducibility of performance management should be aware that an important evaluation factor.

A Study on the Physical Characteristics of Photoconductors for Photon Counting based X-ray Sensor Application (광계수형 기반의 X선 영상센서 적용을 위한 광도전체 물성 연구)

  • Park, Ji Koon;Noh, Si Cheol;Choi, Il Hong;Jung, Bong Jae;Kang, Sang Sik
    • Journal of the Korean Society of Radiology
    • /
    • 제8권7호
    • /
    • pp.423-428
    • /
    • 2014
  • Digital X-ray imaging devices using a TFT based flat panel array has been used in medical field. But, recently, lots of research on the photon counting sensor has been reported. In this study, we evaluated the physical properties of the photoconductor by suggesting the standard and testing method for quantitative performance evaluation of photon counting x-ray imaging sensor. First, we measured the leakage current and the sensitivity of photon counting x-ray imaging sensor and we evaluated the characteristic of rising time for determining the signal shaping time. In addition, the set-up study was conducted on the basis of the IEC 62220-1-2 recommendations to define the number of incident photons per unit area. And the efficiency of the charge collection was also evaluated. As a result, the characteristic was measured as $200pA/mm^2$ of the leakage current, $7{\mu}C/cm^2R $ of the X-ray sensitivity, and $0.765{\mu}s$ of the rising time.

A Study on the Reasonable Personnel Management of Radiology Department -Centering around the General Hospitals in Seoul- (진단방사선과(診斷放射線科)의 적정인력(適正人力) 관리(管理)에 관(關)한 연구(硏究) -서울시내 종합병원(綜合病院) 중심(中心)으로-)

  • Chung, Soon-Kuy
    • Journal of radiological science and technology
    • /
    • 제11권2호
    • /
    • pp.27-64
    • /
    • 1988
  • Most hospital administrators in our country have doubted whether or not the size of their hospital personnel staffs, and the personnel management styles implemented are efficient or not. Actually, increased personnel expenditures due to sophisticated specialization of medical practices has become the biggest hospital expense. Therefore, it is said that hospitals can be run move efficiently by implementing reasonable management strategies for hospital personnel management. In this paper, the departments of diagnostic radiography in 16 general hospitals in Seoul, which were classified into 4 groups by the scale of hospital beds, were used as sample cases. Then, the data for the number of X-ray examination by diagnostic item was collected from sample hospitals. The unit hour spent on X-ray examinations in each diagnostic service was quoted from "A Study on setting-up of the relative value units of medical services and on the structure of current fee schedules" written by Mr. Ik Je Seong. The data analysis results are as follows; First, the number of hours per day spent on X-ray examinations in 13 hospitals out of 16 hospitals, was shorter than the general daily working hours (8 hours). Second, in the morning there was not enough time to work for X-ray examinations required, with the available manpower. In the afternoon, however, the situation was diametrically opposed to that in the morning. Third, in light of above results, though most hospitals employ sufficient personnel for the quantity of the actural work, they were always short-handed where their works were performed Fourth, this study tells us that there is a maldistribution of the work in the schedule : too much work for the available personnel in the morning. The following recommendations are resulted from the data analysis described above. First, it is recommended that all out-patients coming again, except specific patients(G. B. or I.V.P. etc) who have to have their X-ray examinations on an empty stomach in the morning among out-patients, be required to visit the hospital in the afternoon. Second, it is recommended that all new out-patients be required to make a reservation in order to equalize the number of patients throughout the day. Third, it is recommended that all in-patients, except specified patients, be arranged to have their X-ray examinations in the afternoon. Fourth, it is recommended that part time workers be employed during peak hours. This recommendation, if applied in a wider scale, would allow hospitals to overcome the problem of the maldistribution of work and personnel, and then more efficient hospital management through the appropirate personnel management procedures could be expected.

  • PDF

Synthesis of Trimetallic (PtRu-Sn/VC, PtRu-Ni/VC) Catalysts by Radiation Induced Reduction for Direct Methanol Fuel Cell (DMFC) (방사선환원법을 이용한 직접메탄올연료전지용(DMFC) 삼성분계촉매(PtRu-Sn/VC, PtRu-Ni/VC)의 합성)

  • Kim, Sang Kyum;Park, Ji Yun;Hwang, Sun Choel;Lee, Do Kyun;Lee, Sang Heon;Rhee, Young Woo;Han, Moon Hee
    • Clean Technology
    • /
    • 제19권3호
    • /
    • pp.320-326
    • /
    • 2013
  • Nano-sized PtRu-Ni/VC and PtRu-Sn/VC electrocatalysts were synthesized by a one-step radiation-induced reduction (RIR) (30 kGy) process using distilled water as the solvent and Vulcan XC-72 as the supporting material. The obtained electrocatalysts were characterized by transmission electron microscopy (TEM), scanning electron microscope energy dispersive spectroscopic (SEM-EDS), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS), respectively. The catalytic efficiency of electrocatalysts was examined for oxygen reduction, MeOH oxidation and CO stripping decreased in the following order, Hydrogen stripping : PtRu-Sn/VC > PtRu-Ni/VC > PtRu/VC$^{(R)}$ (E-TEK). MeOH oxidation : PtRu-Sn/VC > PtRu-Ni/VC > PtRu/ VC$^{(R)}$ (E-TEK). Unit cell performance : PtRu-Sn/VC > PtRu-Ni/VC > PtRu/VC$^{(R)}$ (E-TEK) catalysts.

High-Resolution X-Ray Photoelectron Spectroscopy Study of a Sb2Te3 Thin Film with the Polycrystalline Phase (고해상도 엑스선 광전자 분광법을 이용한 다결정구조의 안티몬-테레니움 박막 연구)

  • Lee, Y.M.;Kim, K.;Shin, H.J.;Jung, M.C.;Qi, Y.
    • Journal of the Korean Vacuum Society
    • /
    • 제21권6호
    • /
    • pp.348-353
    • /
    • 2012
  • We investigated chemical states of a $Sb_2Te_3$ thin film with the polycrystalline phase by using high-resolution x-ray photoelectron spectroscopy with synchrotron radiation. The $Sb_2Te_3$ thin film was formed by sputtering. The rhombohedral phase was confirmed by x-ray diffraction. To remove the surface oxide, we performed $Ne^+$ ion sputtering for 1 hour with the beam energy of 1 kV and post-annealing at $100^{\circ}C$ for 5 min in ultra-high vacuum. We obtained the Te and Sb 4d core-levels spectra with the peaks at the binding energies of 40.4 and 33.0 eV, respectively. The full-width of half maximum of both the Te and Sb $4d_{5/2}$ core-levels is 0.9 eV. The Te and Sb core-levels only show a single chemical state, and we also confirmed the stoichiometry of approximately 2 : 3.

A Charge Pump Circuit in a Phase Locked Loop for a CMOS X-Ray Detector (CMOS X-Ray 검출기를 위한 위상 고정 루프의 전하 펌프 회로)

  • Hwang, Jun-Sub;Lee, Yong-Man;Cheon, Ji-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • 제13권5호
    • /
    • pp.359-369
    • /
    • 2020
  • In this paper, we proposed a charge pump (CP) circuit that has a wide operating range while reducing the current mismatch for the PLL that generates the main clock of the CMOS X-Ray detector. The operating range and current mismatch of the CP circuit are determined by the characteristics of the current source circuit for the CP circuit. The proposed CP circuit is implemented with a wide operating current mirror bias circuit to secure a wide operating range and a cascode structure with a large output resistance to reduce current mismatch. The proposed wide operating range cascode CP circuit was fabricated as a chip using a 350nm CMOS process, and current matching characteristics were measured using a source measurement unit. At this time, the power supply voltage was 3.3 V and the CP circuit current ICP = 100 ㎂. The operating range of the proposed CP circuit is △VO_Swing=2.7V, and the maximum current mismatch is 5.15 % and the maximum current deviation is 2.64 %. The proposed CP circuit has low current mismatch characteristics and can cope with a wide frequency range, so it can be applied to systems requiring various clock speed.

Investigation on the Structural, Electrical and Magnetic Properties of Layered Perovskite Manganite La0.5Sr1.5Mn0.5Cr0.5-xFexO4 (x=0.15, 0.3) System (층상 페로브스카이트 구조인 La0.5Sr1.5Mn0.5Cr0.5-xFexO4 (x=0.15, 0.3) 망가나이트의 구조적, 전기적, 자기적 특성의 연구)

  • Singh, Devinder
    • Journal of the Korean Chemical Society
    • /
    • 제55권4호
    • /
    • pp.697-702
    • /
    • 2011
  • The new layered perovskite manganites $La_{0.5}Sr_{1.5}Mn_{0.5}Cr_{0.5-x}Fe_xO_4$ (x=0.15, 0.3) have been prepared by standard ceramic method. The powder X-ray diffraction studies show that the phases crystallize with tetragonal unit cell in the space group I4/mmm. The electrical transport properties suggest that the phases show insulating behaviour and the electrical conduction in the phases occurs by a 3D variable range hopping mechanism. The magnetic properties suggest that both the phases are antiferromagnetic.

Synthesis, Structure and Characterization of Nd2XCd2-3XSiO4 (0.01≤X≤0.21) Solid-Solutions (Nd2XCd2-3XSiO4 (0.01≤X≤0.21) 고용체의 합성과 구조 규명)

  • Ramesh, S.;Das, B.B.
    • Journal of the Korean Chemical Society
    • /
    • 제55권3호
    • /
    • pp.502-508
    • /
    • 2011
  • Synthesis of $Nd_{2x}Cd_{2-3x}SiO_4$ ($0.01{\leq}x{\leq}0.21$) [S1-S3: x=0.01, 0.11 and 0.21] solid solutions were prepared by solgel method. Powder x-ray diffraction (XRD) results show monoclinic unit cell with space group P21/m. The average crystallite sizes are found to be 20 to 45 nm. The Scanning Electron Microcopy (SEM) images show morphology of the sample is in globular nature. The energy dispersive analysis of x-rays (EDX) and X-ray mapping results confirmed that all the constituent elements of the composites were present and that were distributed in uniformly. The optical absorption band at ~750 nm was due to $^4I_{9/2}{\rightarrow}^4F_{7/2}+^4S_{3/2}$ transition optically active $Nd^{3+}$ ions. Electron Paramagnetic Resonance (EPR) lineshapes of S1-S3 at 10, 40, 77 and 300 K show a broad unresolved isotropic lineshapes were observed due to rapid spin lattice relaxation of $Nd^{3+}$.

Effect of Molecular Weight on Thermal Behavior of Polyurthanes Containing Mesogen Unit (분자량이 메소겐기를 포함한 폴리우레탄의 열적거동에 미치는 영향)

  • Hong, Sung-Chul;Lee, Woo-Young;Nam, Byeong-Uk;Lee, Sang-Won
    • Elastomers and Composites
    • /
    • 제40권3호
    • /
    • pp.212-221
    • /
    • 2005
  • Polyurethanes containing mesogen unit (MPU-6) were prepared from 4,4'-diphenylmethane diisocyanate (MDI) and 4,4'-bis(6-hydroxy hexoxy)biphenyl (BP-6) having flexible chain composed of 6 carbons. Intrinsic viscosities of MPU-6s were in the range of $0.23{\sim}0.56 dL/g$. The mesomorphic behaviors of MPU-6 were observed in X-ray and polarizing microscopy analysis. However, MPU-6s demonstrated a 'virtual liquid crystal' behavior, which did not exhibit mesophase on slow heating and slow cooling. MPU-6 having lower molecular weight exhibited higher crystallization rate and melting crystallization temperature due to increased mobility of polymer chains. The increased mobility of polymer chains facilitate the orientation of mesogen units that may act as a nucleating agent.