• Title/Summary/Keyword: X-ray radiography

Search Result 524, Processing Time 0.03 seconds

Image Restoration in Dual Energy Digital Radiography using Wiener Filtering Method

  • Min, Byoung-Goo;Park, Kwang-Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.171-176
    • /
    • 1987
  • Wiener filtering method was applied to the dual energy imaging procedure in digital radiography(D.R.). A linear scanning photodiode arrays with 1024 elements(0.6mm H 1.3mm pixel size) were used to obtain chest images in 0.7 sec. For high energy image acquisition, X-ray tube was set at 140KVp, 100mA with a rare-earth phosphor screen. Low energy image was obtained with X-ray tube setting at 70KVp, 150mA. These measured dual energy images are represented in the vector matrix notation as a linear discrete model including the additive random noise. Then, the object images are restored in the minimum mean square error sense using Wiener filtering method in the transformed domain. These restored high and low energy images are used for computation of the basis image decomposition. Then the basis images are linearly combined to produce bone or tissue selective images. Using this process, we could improve the signal to noise ratio characteristics in the material selective images.

  • PDF

A study on the Radiation exposure of simple abdomen x-ray in Radiography (복부 단순 X선검사시 피복 선량에 관한 연구)

  • Ko In Ho;Lee Kyung Sung;Shin Dong Yong
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.57-65
    • /
    • 2001
  • This study was performed to measure about exposure dose during simple abdomen x-ray Radiography. The exposure dose was measured by PDD, surface dose, percentage scatter dose, respectively. The result was as followed: 1. When tube voltage were increased wi

  • PDF

COVID-19 Chest X-ray reading Technique based on Deep Learning (흉부 X-ray 사진 분석을 통한 코로나 판독)

  • Kim, Sung-Jung;Yoo, JaeChern
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.01a
    • /
    • pp.31-32
    • /
    • 2021
  • 신종 코로나바이러스 감염증(Coronavirus disease 2019; COVID-19)이 빠르게 확산됨에 따라 세계적인 전염병 대유행인 팬데믹(Pandemic)으로 선언되었다. 감염자들은 꾸준히 증가하고 있고 최근에는, 무증상 감염자들이 나타나고 있어 의심 환자를 조기에 판단하고 선별할 수 있는 기술이 필요하다. 본 논문에서는 흉부 방사선 검사(chest Radiography; CXR) 영상을 딥러닝(Deep Learning)하여 정상인, 폐렴 환자, 코로나바이러스 감염자를 분류할 수 있도록 한다.

  • PDF

A Study of Radiation Dose and Quality by Using Added Filtration in Chest Radiography (흉부(胸部) X선촬영시(線撮影時) 부가여과사용(附加濾過使用)에 따른 선양(線量)과 선질(線質)에 관(關)한 연구(硏究))

  • You, Byung-Hun;Chu, Sung-Sil;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.10 no.1
    • /
    • pp.13-23
    • /
    • 1987
  • Author has studied for finding the method of decreasing the radiation dose and increasing diagnostic range in chest X-ray radiography. The study for the added filter thickness from half value layer to 1/8 value layer by decreasing curve and research for the exposure factors, decreasing ratio of radiation dose, ratio of scatter ray and image quality in chest X-ray radiography. The results were as follows: 1. By using the rare earth intensifying screen system at 120 Kvp, the sensitivity is increased by times and the exposure ratio is decreased 0.22 by comparison with the $CaWO_{4}$ intensifying screen system at 80 Kvp. 2. By using Al added filter of 1/8 value layer, the scatter ray is increased more than no filter, But the scatter ray is decreased more in $G_{4}/RxOG$ intensifying system than in LT-II/Rx intensifying system. 3. At 120 Kvp, the image quality value of $G_{4}/RxOG$ system is increased more than LT-II/Rx system compared with slight decreasing image quality value at 80 Kvp. Concluded that by using the added filter could decrease the radiation dose by 1/3 and obtain effective image quality with the added filter at high voltage hard exposure.

  • PDF

Image System Using Dual Energy Detector (이중 에너지 검출기를 이용한 영상 시스템)

  • Yeo, Hwa-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3517-3523
    • /
    • 2010
  • Single exposure dual X-ray imaging can be used to separate soft and dense-material images for medical and industrial applications. This study keep focusing baggage inspection system(BIS) specifically. New detector modules for single exposure dual X-ray imaging are consisted of low energy detector (LED) and high energy detector (HED). First, the optimized thickness of copper filter coupled HED to separate low energy and high energy was simulated by the given X-ray energy (140 kVp, 1 mA) using Monte Carlo simulation codes, MCNPX. So as a result of simulation, the copper filter thickness is 0.7 mm. For the design of PIN photodiode, ATLAS device simulation tool was used. 16 channels PIN photodiode of 1.5 mm ${\times}$ 3.2 mm for Dual X-ray imaging detector was fabricated in the process of ETRI. And its dark current and quantum efficiency, terminal capacitance were measured. It was proven that the Lanex Fast B coupled HED were a sufficient candidate to replace the CsI(Tl) commerced in dual X-ray system, since these give a strong signal, overcoming system noise. Finally dual X-ray image was acquired through correction of the LED X-ray Image and the HED X-ray Image.

The MTF Measurement of the Conventional X-ray System by using the Computed Radiography (CR을 이용한 일반촬영장치의 MTF 측정)

  • Kim, Chang-Bok
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.111-115
    • /
    • 2005
  • The quality of image from the system that creates medical images by using X-ray depends on the various different reasons such as the X-ray generator, the subject and the image transmission medium. In other words, thereare various factors existing that can influence on the quality of image from the moment when the X-ray is generated and until the final image is created. Therefore, the operator who creates images at the clinical site should make continuous evaluation and observation from the final image. There are various methods of evaluating the medical images, but it is assumed that the MTF measurement method can be suitable for measuring actual or effective resolution. So in this study, the MTF measurement method by using X-ray film has been avoided and the MTF features according to the deterioration of the X-ray system have been measured by using the software (the program used Borland C++ builder software and LEAD tools software) that can measure the MTF of the digital medical images. As the result of this measurement, it has been found out through the MTF graph that the resolution and sharpness from the old x-ray generator with a many years of using and many numbers of times of using were deteriorated for the quality of image comparing to those from the new system. Also a simple and easy measurement method for the MTF from the digital medical images can be obtained in this study.

  • PDF

A Study on Chest X-ray Using Ancillary Device for Child Radiography (방사선촬영 보조기구를 이용한 어린이 흉부 엑스선 검사에 관한 연구)

  • Rhee, Do-byung;Lee, Somi;Choi, Hyunwoo;Kim, Jong-ki;Lee, Jongmin
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.48-54
    • /
    • 2018
  • In this study, We developed a Ancillary device for child radiography for X-ray of children under 5 years old and verified its effectiveness. Chest X-rays of children younger than 5 years of age were performed by Supine method at the position of Table detector, Short - Source to Image Receptor Distance(SID). Existing Supine and Short -SID imaging methods cause many problems, such as errors in image reading and excessive radiation exposure dose to patients, but the use of an Ancillary device for child radiography(ADCR) solves these problems. A total of 160 children were divided into the Upright group using ADCR and Supine group without ADCR. The chest X-ray image was visually evaluated by two radiologists with reference to the European Commission's List of Quality Criteria for Diagnostic Radiographic Images in Pediatrics. The total score of the qualitative evaluation was 5.15% higher in the chest upright method using ADCR than in the chest supine method without ADCR, and the chest upright method score was higher than that of the chest supine method in items 1 to 7. whether infants have deep inspiration or not, 4.87% higher for item 1, whether infants rotate or not and the degree of tilting, 0% higher for the item 2, the reproduction of image from just above apices of lungs to T12/L1, 0% for the item 3, reproduction of the vascular pattern in central 2/3 of the lungs, 6.92% higher for the item 4, reproduction of the trachea and the proximal bronchi, 12.9% higher for the item 5, visually sharp reproduction of the diaphragm and costo-phrenic angles, 10% higher for the item 6, reproduction of the spine and paraspinal structures and visualisation of the retrocardiac lung and the mediastinum, and 3.65% higher for the item 7. Items 2 and 3 showed no statistically significant differences(P > 0.05), and items 1, 4, 5, 6, and 7 showed statistically significant differences(P < 0.05). In conclusion, Upright method using ADCR in pediatric chest X-ray is considered as a good alternative to existing Supine method.

Development of a Cantilevered Patient Table Considering X-ray Transparency (X-선 투과특성을 고려한 외주형 수술용 테이블 개발)

  • Won B.H.;Chun K.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.189-190
    • /
    • 2006
  • A patient table considering x-ray transparency, mechanical safety and compact multi-axis moving mechanism has been developed. The goal of medical imaging technology is to keep radiation exposure of patients during x-raying to a minimum. In order to obtain clear pictures at low dose, however, the x-ray table which supports the patient must be sufficiently permeable to radiation to allow good image resolution. The table top is made of low density foam for x-ray transparent effective area and structural aluminum plate to connect moving mechanism under the table, covered with thin carbon fiber. This sandwich construction is very rigid and lightweight, so the table top can handle relatively heavy load comparing to its cantilevered structure which is unavoidable as long as cooperate with C-arm radiography. To verify the design results finite element static analysis and experimental tests have been done. According to the verification the results well satisfy certification guide lines as a medical device.

  • PDF

A study of the mandibular canal in digital panoramic radiographic images of a selected Korean population (한국인의 디지털파노라마 방사선영상에서 하악관에 관한 연구)

  • Kim, Jae-Duk;Kim, Jin-Soo
    • Imaging Science in Dentistry
    • /
    • v.37 no.1
    • /
    • pp.9-14
    • /
    • 2007
  • Purpose : To determine the more valuable information to detect the mandibular canal and the mental foramen in panoramic radiographs of a selected Korean population for the implant. Materials and Methods : This study analysed 288 panoramic radiographic images of patients taken at the Dental hospital of Chosun University retrospectively. Indirect digital panoramic X-ray machine (ProlineXC, PLANMECA, Finland) with processing by using Directview $CR950^@$ (Kodak, U.S.A.) and Direct digital panoramic X-ray machine (Promax, PLANMECA, Finland) were used for all exposures. All images were converted into Dicom format. Results : The common position of the mental foramen was in line with the longitudinal axis of the second premolar (68.1%). The mental foramen was symmetrical in 81.8% of cases. The mandibular canal was not identified at anterior portion and discontinued with the mental foramen in 27.8% of all cases, in 42.4% identified with lower border line continued with the mental foramen, in 14.6% with both upper and lower border lines, and in 15.3% unilaterally identified with lower border line. Conclusion : Clinicians can estimate the upper border line of the mandibular canal from the confirmation of the mental foramen and the lower border line of the mandibular canal symmetrically on the panoramic radiography taken in adjusted midsaggital plane of patient's head.

  • PDF

Comparison Evaluation of Image Quality with Different Thickness of Aluminum added Filter using GATE Simulation in Digital Radiography (GATE 시뮬레이션을 사용한 알루미늄 부가필터 두께에 따른 Digital Radiography의 영상 화질 비교 평가)

  • Oh, Minju;Hong, Joo-Wan;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.81-86
    • /
    • 2019
  • In X-ray image, the role of filtration through the filter is to reduce the exposure of the patient by using photon which is useful in formation of the image, and at the same time, enhance the contrast of the image. During interaction between photon and object, low energy X-rays are absorbed from the site of a few cm of the first patient's tissue, and high energy X-rays are the one which form the image. Therefore, the radiation filter absorbs low energy X-ray in order to lower the exposure of the patient and improve the quality of the image. The purpose of this study is to compare the effect on the image quality by differences of added filter through simulation image and actual radiation image. For that purpose, we used Geant4 Application for Tomographic Emission (GATE) as a tool for Monte Carlo simulation. We set actual size, shape and material of Polymethylmethacrylate (PMMA) Phantom on GATE and differentiated the parameter of added filter. Also, we took image of PMMA phantom with same parameter of added filter by digital radiography (DR). Than we performed contrast-to-noise ratio (CNR) evaluation on both simulation image and actual DR image by Image J. Finally, we observed the effect on image quality due to different thickness of added filter, and compared two images' CNR evaluation's transitions of change. The result of this experiment showed decreasing in the progress of CNR on both DR and simulation image. It is ultimately caused by decreasing in contrast on image. In theory, contrast decrease with kVp increased. Given that condition, this study found out that filter makes not only decreasing total dose by absorbing low energy of X-ray, but also increasing average energy of X-ray.