  • This study is to analyze of senile disease status and the social problem according to increased old ages, and then to find distributions of old man's diseases and health status efficiency of oriental-occidental contemporary health examination. And it is the first oriental-occidental contemporary health examination of old man performed by JeonJu Woosuk University Oriental Medicine Hospital and Woosuk-Clinic in nation. Methods The objects in this research are 641's old man of KimJe Gun's over 60's years performed medical examination at JeonJu Woosuk University Oriental- Mmedicine-Hospital and Woosuk-Clinic by oriental-occidental medical contemporary exam., from 1994, 24th June till 1994. 13th July. The 1st occident medical examination methods were consisted of chest x-ray check. blood and urine exam., measurement of blood pressure, visual power and audiometry. The Oriental medical examination methods were consisted of four diagnostics (望,聞,問,切), present illness. chief complaint, past history, families history, social history by question and SA Sang constitution test index. The results and conclusions The results and conclusions are the next: 1. In order of distribution. the athletic disease (75.8%),the digestive disease(43.4%), the circulatory disease(41.5%), the respiratory disease(22.3%), EENT disease(8.1%), the endocrinopathy(5.6%), and the genito-urinary disease(5.3%) are the results of the object about 641's old man, by the oriental-occidental medicine's contemporay exam. 2. Distribution of disease distiction are lumbago. gastritis and peptic ulcer. knee joint pain. heart disease. hypertension. chronic bronchitis. asthma. anemia. DM. Tbc. visual disturbance. CVA. etc in order. 3. Disease distribution according to age is almost high incident in 60-75years. Disease incidence is decreased except E.E.N.T disease in over 76years. 4. The relationships of disease and family history are: the 25.0% of CVA pts. has family history and the 11.6% of hypertension pts has family history. so they showed high relative family history. In addition the 5.6% of TBC pts. and the 2.6% of DM pts. have family history. 5. The relationships of disease and drinking are: Drinking proportion is the 36.4% in respiratory disease pts. the 34.7% in hypertension pts. the 33.3% in heart disease pts.. the 28.4% in digestive disease pts.. but because of no surveying drinking amount we can't know the absolut relationships of disease and drinking. 6. The relationships of Disease and smoking are: Smoking proportion is the 44.1% in respiratory disease pts.. the 38.0% in Heart disease pts.. the 29.8% in Hypertension pts.. but because of no surveying of smoking amount. we can't know the absolut relationships of disease and smoking. 7. Distribution of Sasang constitution is : Tae-eum-in 44.8%. So-yang-in 30.7%. So-eum-in 24.6%. Tae-yang-in 0.0%. And disease distribution of Sasang constitution distinction is ; Tae-eum-in has high incidence of circulation disease(50.0%) and respiratory disease(23.1%).So-yang-in has high incidence of athletics disease(77.7%) and EENT disease(12.2%), So-eum-in has high incidence of digestive disease(65.8%). 8. Distribution of abnormal result in occidental medical examination and oriental-occidental contemporal exam result is considerably different. This is the reason of needing oriental medicine exam, for characteristics of Senile. I think that the oriental-occidental contemporary examination in old man is much more effecient than only occident medical examination. This oriental-occidental contemporary examination has many defects because it is the first practice. To participate in the public health program efficiently. I think that we must improve lots of problems and present the model of the oriental-occidental contemporary examination and the project of oriental medicine's for public health.

  • PDF

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

The Expression of Adhesion Molecules on BAL Cells and Serum Soluble ICAM-1 Level after the Radiotherapy for the Lung Cancer and Its Relationship to the Development of of Radiation Pneumonitis and Fibrosis (방사선 치료후 기관지-폐포세척액내 폐포대식세포 및 임파구의 접착분자발현 변화와 방사선에 의한 폐렴 및 폐섬유증발생의 예측인자로서의 의의)

  • Kim, Dong-Soon;Paik, Sang-Hoon;Choi, Eun-Kyung;Chang, Hye-Sook;Choi, Jung-Eun;Lim, Chae-Man;Koh, Yun-Suck;Lee, Sang-Do;Kim, Woo-Sung;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.75-87
    • /
    • 1996
  • Background: Lung cancer is the second most frequent malignancy in man in Korea. Surgery is the best treatment modality for non-small cell lung cancer, but most patients were presented in far advanced stage. So radiation therapy(RT) with or without chemotherapy is the next choice and radiation-induced pneumonitis and pulmonary fibrosis is the major limiting factor for the curative RT. Radiation pneumonitis is manifested with fever, cough and dyspnea, 2~3 months after the termination of radiotherpy. Chest X ray shows infiltration, typically limited to the radiation field, but occasionally bilateral infiltration was reported. Also Gibson et al reported that BAL lymphocytosis was found in both lungs, even though the radiation was confined to one lung. The aim of this study is to investigate the change of adhesion molecules expression on BAL cells and serum soluble ICAM-1(sICAM-1) level after the RT and its relationship to the development of radiation pneumonitis. The second aim is to confirm the bilaterality of change of BAL cell pattern and adhesion molecule expression. Subjects: BAL and the measurement of sICAM level in serum and BALF were done on 29 patients with lung cancer who received RT with curative intention. The BAL was done before the RT in 16 patients and 1~2 month after RT in 18 patients. 5 patients performed BAL before and after RT. Result: Clinically significant radiation pneumonitis developed in 7 patients. After RT, total cell count in BAL was significantly increased from $(20.2{\pm}10.2){\times}10^6\;cells/ml$ to $(35.3{\pm}21.6){\times}10^6\;cells/ml$ (p=0.0344) and %lymphocyte was also increased from $5.3{\pm}4.2%$ to $39.6{\pm}23.4%$ (p=0.0001) in all patient group. There was no difference between ipsilateral and contraleteral side to RT, and between the patients with and without radiation-pneumonitis. In whole patient group, the level of sICAM-1 showed no significant change after RT(in serum: $378{\pm}148$, $411{\pm}150\;ng/ml$, BALF: $20.2{\pm}12.2$, $45.1{\pm}34.8\;ng/ml$, respectively), but there was a significant difference between the patients with pneumonitis and without pneumonitis (serum: $505{\pm}164$ vs $345{\pm}102\;ng/ml$, p=0.0253, BALF: $67.9{\pm}36.3$ vs $25.2{\pm}17.9\;ng/ml$, p=0.0112). The expression of ICAM-1 on alveolar macrophages (AM) tends to increase after RT (RMFI: from $1.28{\pm}0.479$ to $1.63{\pm}0.539$, p=0.0605), but it was significantly high in patients with pneumonitis ($2.10{\pm}0.390$) compared to the patients without pneumonitis ($1.28{\pm}0.31$, p=0.0002). ICAM-1 expression on lymphocytes and CD 18 (${\beta}2$-integrin) expression tended to be high in the patients with pneumonitis but the difference was statiastically not significant. Conclusion: Subclinical alveolitis on the basis of BAL finding developed bilaterally in all patients after RT. But clinically significant pneumonitis occurred in much smaller fraction and the ICAM-1 expression on AM and the sICAM-1 level in serum were good indicator of it.

  • PDF

Analysis of the ESD and DAP According to the Change of the Cine Imaging Condition of Coronary Angiography and Usefulness of SNR and CNR of the Images: Focusing on the Change of Tube Current (관상동맥 조영술(Coronary Angiography)의 씨네(cine) 촬영조건 변화에 따른 입사표면선량(ESD)과 흡수선량(DAP) 및 영상의 SNR·CNR 유용성 분석: 관전류 변화를 중점으로)

  • Seo, Young Hyun;Song, Jong Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.371-379
    • /
    • 2019
  • The purpose of this study was to investigate the effect of the change in the X-ray condition on the entrance surface dose (ESD) and dose area product (DAP) in the cine imaging of coronary angiography (CAG), and to analyze the usefulness of the condition change on the dose relation and image quality by measuring and analyzing the Signal to Noise Radio (SNR) and Contrast to Nois Ratio (CNR) of the angiographic images taken by the Image J program. Data were collected from 33 patients (24 males and 9 females) who underwent CAG at this hospital from November 2017 to March 2018. In terms of imaging condition and data acquisition, the ESD and DAP of group A with a high tube current of 397.2 mA and group B with a low tube current of 370.7 mA were retrospectively obtained for comparison and analysis. For the SNR and CNR measurement and analysis via Image J, the result values were derived by substituting the obtained data into the formula. The correlations among ESD and DAP according to the change in the imaging condition, SNR, and CNR were analyzed by using the SPSS statistical analysis software. The relationships of groups A and B, having a difference in the imaging condition, mA, with ESD ($A:483.5{\pm}60.1$; $B: 464.4{\pm}39.9$) and DAP ($A:84.3{\pm}10.7$; $B:81.5{\pm}7$) were not statistically significant (p>0.05). In the relationships with SNR and CNR based on Image J, the SNR ($5.451{\pm}0.529$) and CNR ($0.411{\pm}0.0432$) of the images obtained via the left coronary artery (LCA) imaging of group B showed differences of $0.475{\pm}0.096$ and $-0.048{\pm}0.0$, respectively, from the SNR ($4.976{\pm}0.433$) and CNR ($0.459{\pm}0.0431$) of the LCA of group A. However, the differences were not statistically significant (p<0.05). In the SNR and CNR obtained via the right coronary artery (RCA) imaging, the SNR ($4.731{\pm}0.773$) and CNR ($0.354{\pm}0.083$) of group A showed increased values of $1.491{\pm}0.405$ and $0.188{\pm}0.005$, respectively, from the SNR ($3.24{\pm}0.368$) and CNR ($0.166{\pm}0.033$) of group B. Among these, CNR was statistically significant (p<0.05). In the correlation analysis, statistically significant results were shown in SNR (LCA) and CNR (LCA); SNR (RCA) and CNR (RCA); ESD and DAP; ESD and sec; DAP and CNR (RCA); and DAP and sec (p<0.05). As a result of the analyses on the image quality evaluation and usefulness of the dose change, the SNR and CNR were increased in the RCA images of the CAG obtained by increasing the mA. Based on the result that CNR showed a statistically significant difference, it is believed that the contrast in the image quality can be further improved by increasing the mA in RCA imaging.

Effect of Carbon Couch Side Rail and Vac-lok In case of Lung RPO irradiation (Lung RPO 선량전달시, Carbon Couch Side Rail과 Vac-lok이 미치는 영향)

  • Kim, Seok Min;Gwak, Geun Tak;Lee, Seung Hun;Kim, Jung Soo;Kwon, Hyoung Cheol;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.27-34
    • /
    • 2018
  • Purpose : To evaluate the effect of carbon couch side rail and vacuum immobilization device in case of lung RPO irradiation. Materials and Methods : The 10, 20, 30 mm thickness of vac-lok's right side were obtained. To measure of doses, glass dosimeters were used and measured reference point is left lung center at the phantom. A, B, C, and D points are left, right, down, and up directions based on the center point. In the state of Side-Rail-Out, place the without vac-lok, with the thickness of 10, 20, and 30 mm vac-lok. After the glass dosimeters was inserted in center, A, B, C, and D points, 100 MU of 6 MV X-ray were irradiated to the referenced center point in the condition of $10{\times}10cm^2$ field size, SAD 100 cm, gantry angle 225, 300 MU/min dose rate. Five measurements were made for each point. In the state of Side-Rail-In, five measurement were made for each point under the same conditions. The average is measured on each of the five Side-Rail-Out and Side-Rail-In measurements. Results : In the presence of side rail, the dose reduction ratio was -11.8 %, -12.3 %, -4.1 %, -12.3 %, -7.3 % for each A, B, C, and D points. In the state of Side-Rail-Out, the dose reduction ratio for the using 10 mm thickness of vac-lok was -0.9 % than without vac-lok. The dose reduction ratio for the using 20 mm thickness of vac-lok was -2.0 %, for the using 30 mm thickness of the vac-lok was -3.0 % than without vac-lok. In the state of Side-Rail-In, the dose reduction ratio for the using 10 mm thickness of vac-lok was -1.0 % than without vac-lok. The dose reduction ratio for the using 20 mm vac-lok was -2.1 %, for the using 30 mm vac-lok was -3.0 % than without vac-lok. Based on the value of no vac-lok dose in the Side-Rail-In state, The dose reduction ratios for the using 10 mm, 20 mm and 30 mm thickness of vac-loks In the Side-Rail-Out that the center point were -12.7 %, -13.7 %, -14.2 % and -12.8 %, -13.8 %, -14.5 % respectively at point A. The dose reduction ratios for the same conditions to the B point were -4.9 %, -6.1 %, -7.1 % and -13.4 %, -14.4 %, -15.5 % respectively at point C. The dose reduction ratios for the same conditions to the D point were -8.4 %, -9.0 %, -10.4 % respectively. Conclusion : The attenuation was caused by presence of side rails and thickness of vac-lok. Pay attention to these attenuation factors, making it a more effective radiation therapy.