• Title/Summary/Keyword: X-ray measurement

Search Result 1,305, Processing Time 0.037 seconds

A Study on Dosimetry for Small Fields of Photon Beam (광자선 소조사면의 선량 측정에 관한 연구)

  • 강위생;하성환;박찬일
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.57-68
    • /
    • 1994
  • Purpose : The purposes are to discuss the reason to measure dose distributions of circular small fields for stereotactic radiosurgery based on medical linear accelerator, finding of beam axis, and considering points on dosimetry using home-made small water phantom, and to report dosimetric results of 10MV X-ray of Clinac-18, like as TMR, OAR and field size factor required for treatment planning. Method and material : Dose-response linearity and dose-rate dependence of a p-type silicon (Si) diode, of which size and sensitivity are proper for small field dosimetry, are determined by means of measurement. Two water tanks being same in shape and size, with internal dimension, 30${\times}$30${\times}$30cm$^3$ were home-made with acrylic plates and connected by a hose. One of them a used as a water phantom and the other as a device to control depth of the Si detector in the phantom. Two orthogonal dose profiles at a specified depth were used to determine beam axis. TMR's of 4 circular cones, 10, 20, 30 and 40mm at 100cm SAD were measured, and OAR's of them were measured at 4 depths, d$\sub$max/, 6, 10, 15cm at 100cm SCD. Field size factor (FSF) defined by the ratio of D$\sub$max/ of a given cone at SAD to MU were also measured. Result : The dose-response linearity of the Si detector was almost perfect. Its sensitivity decreased with increasing dose rate but stable for high dose rate like as 100MU/min and higher even though dose out of field could be a little bit overestimated because of low dose rate. Method determining beam axis by two orthogonal profiles was simple and gave 0.05mm accuracy. Adjustment of depth of the detector in a water phantom by insertion and remove of some acryl pates under an auxiliary water tank was also simple and accurate. TMR, OAR and FSF measured by Si detector were sufficiently accurate for application to treatment planning of linac-based stereotactic radiosurgery. OAR in field was nearly independent of depth. Conclusion : The Si detector was appropriate for dosimetry of small circular fields for linac-based stereotactic radiosurgery. The beam axis could be determined by two orthogonal dose profiles. The adjustment of depth of the detector in water was possible by addition or removal of some acryl plates under the auxiliary water tank and simple. TMR, OAR and FSF were accurate enough to apply to stereotactic radiosurgery planning. OAR data at one depth are sufficient for radiosurgery planning.

  • PDF

Usefulness of Interferon-$\gamma$ Measurement Following Stimulation of Tuberculosis-specific Antigens for Diagnosis of Latent Tuberculosis Infection in Children Exposed to Pulmonary Tuberculosis (폐결핵 접촉력을 가진 소아에서 잠복 결핵 감염의 진단을 위한 결핵 특이항원 자극 인터페론-감마 측정의 유용성)

  • Sung, Ji Yeon;Ki, Joo Hwa;Yang, Mi Ae;Kim, So Hee;Eun, Byung Wook;Kim, Nam Hee;Park, Kyoung Un;Lee, Jina;Choi, Eun Hwa;Lee, Hoan Jong
    • Pediatric Infection and Vaccine
    • /
    • v.15 no.1
    • /
    • pp.52-58
    • /
    • 2008
  • Purpose : Whole blood interferon-$\gamma$ assay was developed and many studies showed its usefulness in diagnosing tuberculosis (TB) including latent tuberculosis infection (LTBI). However, assessment in children has been limited. This study was undertaken to evaluate the usefulness of QuantiFERON-TB Gold for the diagnosis of LTBI in children exposed to pulmonary TB. Methods : Children who visited Seoul National University Bundang Hospital with a history of TB exposure were enrolled from January 2006 to December 2007. They were evaluated with chest x-rays, tuberculin skin test (TST) and QuantiFERON-TB Gold test. TST was retested 3 months later for those with initial negative reactivity. Definition of LTBI was made on the basis of the TST reactivity. Results : Among the 103 children with a history of TB exposure, 49 children were tested with chest x-ray, TST, and QuantiFERON-TB Gold. Twenty-two were males. Median age was 7.5 years (range; 3 months to 14.7 years). According to TST reactivity, LTBI was in 8 (19%), no infection was in 21 (50%), possible LTBI was in 13 (31%). QuantiFERON-TB Gold test was positive in 5 of the 49 subjects (10%); 3 of the 13 subjects (23.1%) in unknown status, 1 of the 8 subjects (13%) in LTBI, and 1 of the 21 subjects (5%) without infection. The agreement between the QuantiFERON-TB Gold and the TST was poor (${\kappa}=0.101$). Conclusion : QuantiFERON-TB Gold showed poor sensitivity for the diagnosis of LTBI in children with exposure to TB. QuantiFERON-TB Gold alone does not seem to be useful in the diagnosis of LTBI in children.

  • PDF

Comparative Analysis of Bone Mineral Contents with Dual-Energy Quantitative Computed Tomography (이중에너지광자선의 전산화단층촬영술을 이용한 정량적 골무기물함량의 비교분석)

  • Choi, Tae-Jin;Yoon, Seon-Min;Kim, Ok-Bae;Lee, Sung-Moon;Suh, Soo-Jhi
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.153-158
    • /
    • 1997
  • Purpose : The Dual-Energy Quantitative Computed Tomography(DEQCT) was compared with bone equivalent $K_2HPO_4$ standard solution and ash weight of animal cadaveric trabecular bone in the measurement of bone mineral contents(BMC). Method and Materials : The attenuation coefficient of tissues highly depends on the radiation energy density and effective atomic number of composition, The bone mineral content of DEQCT in this experiments was determined from empirical constants and mass attenuation coefficients of bone,fat and soft tissue equivalent solution in two photon spectra. In this experiments, the BMC of DEQCT with 80 and $120kV_p$ X rays was compared to ash weight of animal trabecular bone. Results : We obtained the mass attenuation coefficient of 0.2409 0.5608 and 0.2206 in $80kV_p$, and 0.2046, 0.3273 and $0.1971cm^2/g$ in $120kV_p$ X-ray spectra for water bone and fat equivalent materials, respectively. The BMC with DEQCT was acomplished with empirical constants $K_1=0.3232,\;K_2$=0.2450 and mass attenuation coefficients has very closed to ash weight of animal trabecular bone The BMC of empirical DEQCT and that of manufacturing DEQCT were correlated with ash weight as a correlation r= 0.998 and r= 0.996, respectively. Conclusion : The BMC of empirical DEQCT using the experimental mass attenuation coefficients and that of manufacture have showed very close to ash weight of animal trabecular bone.

  • PDF

Effect of Flavopiridol on Radiation-induced Apoptosis of Human Laryngeal and Lung Cancer Cells (후두암 및 폐암 세포주에서 Flavopiridol이 방사선에 의한 아포토시스에 미치는 영향)

  • Kim, Su-Zy;Kwon, Eun-Kyung;Lee, Seung-Hee;Park, Hye-Jin;Wu, Hong-Gyun
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.227-232
    • /
    • 2007
  • Purpose: To investigate the flavopiridol effect on radiation-induced apoptosis and expression of apoptosisrelated genes of human laryngeal and lung cancer cells. Materials and Methods: A human laryngeal cancer cell line, AMC-HN3 and a human lung cancer cell line, NCI-H460, were used in the study. The cells were divided into four groups according to the type of treatment: 1) control groups; 2) cells that were only irradiated; 3) cells treated only with flavopiridol; 4) cells treated with flavopiridol and radiation simultaneously. The cells were irradiated with 10 Gy of X-rays using a 4 MV linear accelerator. Flavopiridol was administered to the media at a concentration of 100 nM for 24 hours. We compared the fraction of apoptotic cells of each group 24 hours after the initiation of treatment. The fraction of apoptotic cells was detected by measurement of the sub-G1 fractions from a flow cytometric analysis. The expression of apoptosis-regulating genes, including cleaved caspase-3, cleaved PARP (poly (ADP-ribose) polymerase), p53, p21, cyclin D1, and phosphorylated Akt (protein kinase B) were analyzed by Western blotting. Results: The sub-G1 fraction of cells was significantly increased in the combination treatment group, as compared to cells exposed to radiation alone or flavopiridol alone. Western blotting also showed an increased expression of cleaved caspase-3 and cleaved PARP expression in cells of the combination treatment group, as compared with cells exposed to radiation alone or flavopiridol alone. Treatment with flavopiridol down regulated cyclin 01 expression of both cell lines but its effect on p53 and p21 expression was different according to each individual cell line. Flavopiridol did not affect the expression of phophorylated Akt in both cell lines. Conclusion: Treatment with flavopiridol increased radiation-induced apoptosis of both the human laryngeal and lung cancer cell lines. Flavopiridol effects on p53 and p21 expression were different according to the individual cell line and it did not affect Akt activation of both cell lines.

Measurement of Image Quality According to the Time of Computed Radiography System (시간에 따르는 CR장비의 영상의 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Hwang, Sun-Kwang;Lee, Ik-Pyo;Kim, Ki-Won;Jung, Jae-Yong;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.365-374
    • /
    • 2015
  • The regular quality assurance (RQA) of X-ray images is essential for maintaining a high accuracy of diagnosis. This study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) of a computed radiography (CR) system for various periods of use from 2006 to 2015. We measured the pre-sampling MTF using the edge method and RQA 5 based on commission standard international electro-technical commission (IEC). The spatial frequencies corresponding to the 50% MTF for the CR systems in 2006, 2009, 2012 and 2015 were 1.54, 1.14, 1.12, and $1.38mm^{-1}$, respectively and the10% MTF for 2006, 2009, 2012, and 2015 were 2.68, 2.44, 2.44, and $2.46mm^{-1}$, respectively. In the NPS results, the CR systems showed the best noise distribution in 2006, and with the quality of distributions in the order of 2015, 2009, and 2012. At peak DQE and DQE at $1mm^{-1}$, the CR systems showed the best efficiency in 2006, and showed better efficiency in order of 2015, 2009, and 2012. Because the eraser lamp in the CR systems was replaced, the image quality in 2015 was superior to those in 2009 and 2012. This study can be incorporated into used in clinical QA requiring performance and evaluation of the performance of the CR systems.

Calculation of Renal Depth by Conjugate-View Method Using Dual-head Gamma Camera (이중 헤드 감마 카메라를 이용한 Conjugate-View 계수법에 의한 신장 깊이 도출)

  • Kim, Hyun-Mi;Suh, Tae-Suk;Choe, Bo-Young;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.378-388
    • /
    • 2001
  • Purpose: In this study, we developed a new method for the determination of renal depth with anterior and posterior renal scintigrams in a dual-head gamma camera, considering the attenuation factor $e^{-{\mu}x}$ of the conjugate-view method. Material and Method: We developed abdomen and kidney phantoms to perform experiments using Technetium-99m dimercaptosuccinic acid ($^{99m}Tc$-DMSA). The phantom images were obtained by dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators (ICONf, Siemens). The equation was derived from the linear integration of omission ${\gamma}$-ray considering attenuation from the posterior abdomen to the anterior abdomen phantom surface. The program for measurement was developed by Microsoft Visual C++ 6.0. Results : Renal depths of the phantoms were derived from the derived equations and compared with the exact geometrical values. Differences between the measured and the calculated values were the range of 0.1 to 0.7 cm ($0.029{\pm}0.15cm,\;mean{\pm}S.D.$). Conclusion: The present study showed that the use of the derived equations for renal depth measurements, combined with quantitative planar imaging using dual-head gamma camera, could provide more accurate results for individual variation than the conventional method.

  • PDF

Magnetic and Electric Transport Properties of MnTe Thin Film Grown by Molecular Beam Epitaxy (분자선 증착법에 의해 성장한 MnTe 박막의 자기적 및 전기수송 특성)

  • Kim, Woo-Chul;Bae, Sung-Whan;Kim, Sam-Jin;Kim, Chul-Sung;Kim, Kwang-Joo;Yoon, Jung-Bum;Jung, Myung-Hwa
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.2
    • /
    • pp.81-85
    • /
    • 2007
  • MnTe layers of high crystalline quality were successfully grown on Si(100) : B and Si(111) substrates by molecular beam epitaxy (MBE). Under tellurium-rich condition and the substrate temperature around $400^{\circ}C$, a layer thickness of $700{\AA}$ could be easily obtained with the growth rate of $1.1 {\AA}/s$. We investigated the structural, magnetic and transport properties of MnTe layers by using x-ray diffraction (XRD), superconducting quantum interference device (SQUID) magnetometry, and physical properties measurement system (PPMS). Characterization of MnTe layers on Si(100) : B and Si(111) substrates by XRD revealed a hexagonal structure of polycrystals with lattice parameters, ${\alpha}=4.143{\pm}0.001{\AA}\;and\;c=6.707{\pm}0.001{\AA}$. Investigation of magnetic and transport properties of MnTe films showed anomalies unlike antiferromagnetic powder MnTe. The temperature dependence of the magnetization data taken in zero-field-tooling (ZFC) and field-cooling (FC) conditions indicates three magnetic transitions at around 21, 49, and 210 K as well as the great irreversibility between ZFC and FC magnetization in the films. These anomalies are attributable to a magnetic-elastic coupling in the films. Magnetization measurements indicate ferromagnetic behaviour with hysteresis loops at 5 and 300 K for MnTe polycrystalline film. The coercivity ($H_c$) values at 5 and 300 K are 55 and 44 Oe, respectively. In electro-transport measurements, the temperature dependence of resistivity revealed a noticeable semiconducting behaviours and showed conduction via Mott variable range hopping at low temperatures.

Change of Volume of Isoflow in Pneumoconiosis Patients with Small Opacity (소음영 진폐증 환자에서의 등기류용량(Volume of Isoflow)의 변화)

  • Oh, Sang-Yong;Kim, Jee-Won;Jung, Chang-Young;Kim, Kyung-Ah;Yun, Im-Goung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.5
    • /
    • pp.540-547
    • /
    • 1993
  • Backgrounds: The measurement of volume of isoflow has been considered as a sensitive test for detecting small airway diseases showing normal pulmonary function in a routine pulmonary function test. To evaluate the functions of small airway among dust exposed workers, the changes of volume of isoflow were measured and its applicability of managing early stage pneumoconiosis patients was studied. Method: The subjects were 67 male, pneumoconiosis with small opacity and FEV1>80%, FEV1/FVC>75% in spirometry and the controls were 20 male, no dust-exposed office workers. The maximal epiratory volume curves after inhalation of indoor air and $He-O_2$ gas mixtures were measured and ${\Delta}V_{max50},\;{\Delta}V_{max75},\;V_{iso}V/VC$ between the dust exposed and control workers were compaired. Results: 1) There were no significant differences between two group in ${\Delta}V_{max50}$ and ${\Delta}V_{max75}$. But the ratio of $V_{iso}V/VC$ of the subjects was siginificantly higher than that of the control (p<0.01). This study confirms that $V_{iso}V/VC$ is a very useful index in early detection of small airway dysfunction. 2) The ratio of $V_{iso}V/VC$ of the subjects was signigicantly different between only smoker group and mixed group(smoker and nonsmoker). It suggestes that smoking is an important cousative factor of small airway dysfunction. 3) As the profusion of the chest X-ray increased, the rartio of $V_{iso}V/VC$ increased, but no significant difference of $V_{iso}V/VC$ was found between categories of pneumoconiosis. The categories of pneumoconiosis and small airway dysfunction may not be related. 4) No significant relationship was established between the duration of work and the ratio of $V_{iso}V/VC$. Conclusions : It is concluded that the measurement of $V_{iso}V/VC$ is useful to detect small airway dysfuction of early stage pnuemoconiosis patents with small opacities but showing normal pulmonary function in a routine pulmonary function test.

  • PDF

Factors Related to Bone Mineral Content Among Adolescents in Seoul (서울시 일부 청소년의 골질량 관련요인)

  • Shin, Sang-Ah;Hong, Kyung-Eui;Choi, Hyun-Jeong;Roh, Ji-Hyun;Joung, Hyo-Jee
    • Journal of Nutrition and Health
    • /
    • v.41 no.2
    • /
    • pp.156-164
    • /
    • 2008
  • The purpose of this study was to investigate factors related to bone mineral contents (BMC) at os calcis of adolescents. The subjects were 604 students (327 boys and 277 girls) between 7th and 9th grade in Seoul, Korea. The mean age was 14.2 ${\pm}$ 0.9 years. General characteristics were collected by a questionnaire, bone mineral contents (BMC) were measured in os calcis by Duel Energy X-ray Absorptiometry (PIXI, General Electronics, USA) and height and weight were measured by bioelectrical impedance analysis method (Inbody 4.0, Biospace Co. Ltd, Seoul, Korea). Mean BMC of os calsis were 2.241 g. Height (p <.0001), weight (p <.0001I), BMC (p <.0001I) ofboys were higher than those of girls. Percent body fat of girls, however, was higher than that of boys (p <.0001). Anthropometric measurement, pocket money, sibling, experience of fracture, pubertal stage, intake of supplements, physical or outdoors activity, and eating habit had significant influence on BMC of boys. Anthropometric measurement, physical or outdoors activity, and eating habit had significant influence on BMC of girls. Multivariate regression with adjustment for sex and age showed that BMC was associated positively with height, BMI, frequency of regular activity, and intake of spinach or radish leaves (all p <0.05), and negatively with percent body fat (p <.0000 and Korean traditional diet pattern (p = 0.01). On the basis of these results, it is recommended to develop nutrition education and physical activity program for adolescents to improve BMC and prevent osteoporosis.

Transmission Dose Estimation Algorithm for in vivo Dosimertry (투과선량을 이용한 생체내 (in vivo) 선량측정을 위한 알고리즘)

  • Yun, Hyong-Geun;Chie, Eui-Kyu;Huh, Soon-Nyung;Lee, Hyoung-Koo;Woo, Hong-Gyun;Shin, Kyo-Chul;Kim, Si-Yong;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.147-154
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry of QA purpose. The objective of this study is to develope an algorithm for estimation of tumor dose using measured transmission dose for open radiation field. Materials and Methods : Transmission dose was measured with various field size (FS), phantom thickness (Tp), and phantom chamber distance (PCD) with a acrylic phantom for 6 MV and 10 MV X-ray. Source to chamber distance (SCD) was set to 150 cm. Measurement was conducted with a 0.6 co Farmer type ion chamber. Using measured data and regression analysis, an algorithm was developed lot estimation of expected reading of transmission dose. Accuracy of the algorithm was tested with flat solid phantom with various settings. Results : The algorithm consisted of quadratic function of log(A/P) (where A/P is area-perimeter ratio) and tertiary function of PCD. The algorithm could estimate dose with very high accuracy for open square field, with errors within ${\pm}0.5%$. For elongated radiation field, the errors were limited to ${\pm}1.0%$. Conclusion : The developed algorithm can accurately estimate the transmission dose in open radiation fields with various treatment settings.