X-선 투과검사를 이용한 저항 점용접부 품질평가기법 (Weld Quality Evaluation Method for the Resistance Spot Welds using X-ray Transmission Inspection)

  • 이종대;이소정;방정환;윤길상;김목순;김준기
    • Journal of Welding and Joining
    • /
    • 제32권6호
    • /
    • pp.1-7
    • /
    • 2014
  • For the resistance spot welds of CR1180 and GA1180 TRIP steels, the weld quality evaluation method using the digitalized X-ray transmission imaging apparatus was investigated in comparison with the crosssectional examination method. In the case of the resistance spot welding of CR1180, three circular regions, such as WZ(white zone), GZ(grey zone) and DZ(dark zone), appeared on X-ray image and they corresponded to the diameters of indentation mark, nugget and corona bond, respectively. The variation of X-ray transmission thickness due to the thickness variation of the weld seemed to be mainly responsible for the formation of those contrasts. The X-ray image contrast formed from the variation of transmission thickness at the outer border line of DZ could also enable the inspections of the notch shape, nonuniformity of the welding pressure and spatter from its sharpness, concentricity and the normal straight line, respectively. The X-ray image of the resistance spot weld of galvannealed GA1180 TRIP steel was very similar to that of CR1180 TRIP steel except the crown shaped outer border line of DZ which was considered to be due to the melting behavior of zinc having the boiling temperature even lower than the melting temperature of steel.

스테레오 X-ray 시스템 검색기능 개선 연구 (The Study for the Efficient scanning of Stereo X-ray System)

  • 황영관;이남호;박종원
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.884-886
    • /
    • 2012
  • 일반적으로 사용하고 있는 X-선 검색장치는 대상물의 단면 정보만을 제공하고 있기에 검색 대상체를 식별에 어려움이 있어 이에 대한 개선이 요구되어 왔다. 스테레오 X-ray 시스템은 기존의 검색장치에 라인센서를 추가하여 검색 대상체에 대한 추가적인 정보를 제공함으로써 검색 효율을 높이도록 고안되었다. 본 논문에서는 선행 연구를 통해 개발된 스테레오 X-선 검색장치의 검색 속도를 향상시키기 위하여 정밀제어를 위한 제어부를 설계하고 이를 통해 이동체와 검색기의 스캔 속도를 동기화 하고 대상체의 검색 속도를 개선하였다. 본 연구의 결과는 대형 화물 스캔 장치 및 고속화물 스캔 장치 개발을 위해 활용될 수 있다.

  • PDF

이중 에너지 검출기를 이용한 영상 시스템 (Image System Using Dual Energy Detector)

  • 여화연
    • 한국산학기술학회논문지
    • /
    • 제11권9호
    • /
    • pp.3517-3523
    • /
    • 2010
  • 본 논문은 이중 에너지 DR(Digital Radiography) 방식 중, 단일 조사 X-선(single shot X-ray exposure) 장치와 이중 모드 검출기 모듈 (Low Energy Detector & High Energy Detector)을 이용한 이중 X-선 이미징이 가능한 검출기 모듈에 관한 연구이다. 상용 BIS(baggage inspection system)에서 사용되고 있는 X-선 발생장치의 스펙트럼과 이중 모드 검출기에 대한 특징 및 방사선적 특성을 분석하여 새롭게 제안 할 검출기 모듈의 최적 설계 방향을 기술하고 상용화된 용화된 LED 및 HED 검출기와 새롭게 제안 한 검출기 모듈에 대해 전기적, 광학적, 방사선적 특성 실험을 실시하여, 새롭게 제안된 검출기 모듈이 BIS 용도로 사용 가능함을 증명하였다. 새롭게 제안 된 검출기 모듈이 적용된 BIS에 대해, 기본 특성 실험에 대한 X-선 영상을 획득하여 실험 및 분석을 실시하였다.

스테레오 X-선 검색장치를 이용한 3차원 정보 가시화에 관한 연구 (The Geometric Modeling for 3D Information of X-ray Inspection)

  • 황영관;이승민;박종원
    • 전기학회논문지
    • /
    • 제63권1호
    • /
    • pp.145-149
    • /
    • 2014
  • In this study, using X-ray cargo container scanning device and to differentiate the concept of three-dimensional information extraction applied for X-ray scanning device as an ingredient in the rotation of the X-Ray Linear Pushbroom Stereo System by introducing the geometric How to model was introduced. Three-dimensional information obtained through the matching of a single voxel space filled with a random vector operations for each voxel in the three dimensional shape reconstruction algorithm using the definition, and in time, the time required for each step were analyzed. Using OpenCV in each step by applying parallelization techniques approximately 1.8 times improvement in the processing time of the check, but do not meet the target within one minute levels. The other hand, X-ray images by the primary process to convert the point View the results of real-time stereo through a three-dimensional could feel the comfort level.

조사시험용 핵연료봉 용접부 비파괴검사에 관한 연구 (A Study on the Non-destructive Inspection for End Closure Welding of Nuclear Fuel Elements for the Irradiation Test)

  • 김웅기;김수성;이철용;이도연;이정원
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2004년도 춘계 학술발표대회 개요집
    • /
    • pp.302-304
    • /
    • 2004
  • Nuclear fuel elements containing dry recycling nuclear fuel pellets for the irradiation test in a reactor were remotely fabricated from spent PWR fuel materials in a hot cell. End closure welding as well as seal tube welding for thermal sensor of the elements was performed by Nd:YAG laser. The soundness of the end closure welds and seal tube welds for the elements were evaluated by a precise X-ray inspection system composed of a micro-focus X-ray generator with an image intensifier and a real time camera system. Then, helium leak test was performed for the elements. The soundness of the welds of the fuel elements was confirmed by the X-ray inspection and helium leak test. The irradiation test for the fuel elements were successfully completed at the HANARO research reactor.

  • PDF

임상용 X-선관을 이용한 X-ray PIV시스템의 개발 (Development of X-ray PIV System Using a Medical X-ray Tube)

  • 임대현;김국배;김도일;이형구;이상준
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.403-406
    • /
    • 2006
  • A new medical X-ray PIV technique was developed using a conventional medical X-ray tube. To acquire images of micro-scale particles, the X-ray PIV system consists of an x-ray CCD camera with high spatial resolution, and a X-ray tube with small a focal spot. A new X-ray exposure control device was developed using a rotating disc shutter to make double pulses which are essential for PIV application. Synchronization methodology was also developed to apply the PIV technique to a conventional medical X-ray tube. In order to check the performance and usefulness of the developed X-ray PIV technique, it was applied to a glycerin flow in an opaque silicon tube. Tungsten particles which have high X-ray absorption coefficient were used as tracer particles. Through this preliminary test, the spatial resolution was found to be higher than ultrafast MRI techniques, and the temporal resolution was higher than conventional X-ray PIV techniques. By improving its performance further and developing more suitable tracers, this medical X-ray PIV technique will have strong potential in the fields of medical imaging or nondestructive inspection as well as diagnosis of practical thermo-fluid flows.

  • PDF

시각센서를 이용한 인쇄회로기판의 J-리드 납땜 검사에 관한 연구 (A Study on J-lead Solder Joint Inspection of PCB Using Vision System)

  • 유창목;차영엽;김철우;권대갑;윤한종
    • 한국정밀공학회지
    • /
    • 제15권5호
    • /
    • pp.9-18
    • /
    • 1998
  • The components with J-lead. which are more integrated and smaller than ones with Gull-wing. are rapidly being used in electronic board such as the PCB, for they have the advantage of occupying a small space compared to the other components. However, the development of inspection system for these new components is not so rapid as component development. Component-inspection with J-lead using vision system is difficult because they are hidden from camera optical axis. X-ray inspection, which has the advantage of inspecting the inside of solder state, is used to J-lead inspection. However. it is high cost and dangerous by leaking out X-ray compared to vision system. Therefore, in this paper, we design vision system suited to J-lead inspection and then propose algorithm which have flexibility in mount and rand error.

  • PDF

X-Ray 어레이 검출 모듈 신호처리 시스템 개발 (Development of X-Ray Array Detector Signal Processing System)

  • 임익찬;박종원;김영길;성소영
    • 한국정보통신학회논문지
    • /
    • 제23권10호
    • /
    • pp.1298-1304
    • /
    • 2019
  • 9.11 테러 이후 미국을 비롯한 선진국들의 해운물류 안전 보안체계가 크게 강화되었다. 해운물류의 검색에는 강력한 방사선을 투과하여 컨테이너의 내부를 확인하는 컨테이너 검색기 시스템을 주로 사용하는데, 국내에서는 전량 도입품을 적용하여 운용 중이며 국산화 개발에 대한 요구가 증가하고 있다. 이에 본 논문에서는 컨테이너 검색기 시스템의 핵심 구성요소인 X-Ray 어레이 검출 모듈 신호처리 시스템을 개발하여 제안한다. 아날로그 및 디지털 신호처리부를 통합형 하드웨어로 제작하였으며, X-선 데이터의 실시간 수집과 분석을 위해 FPGA 로직과 소프트웨어를 구현하여 시험하였다. 구현된 시스템은 기존 항만에서 사용되는 도입품 대비 해상도와 소비전력 면에서 우세하다.

이온전리함 기반의 컨테이너 검색용 고에너지 X-선 선량 측정장치 개발 (Development of High Energy X-ray Dose Measuring Device based Ion Chamber for Cargo Container Inspection System)

  • 이정희;임창휘;박종원;이상헌
    • 한국정보통신학회논문지
    • /
    • 제24권12호
    • /
    • pp.1711-1717
    • /
    • 2020
  • 일반적으로 컨테이너 내부검사를 위해서는 최대 9MeV의 X-선을 사용한다. 이때 사용되는 X-선은 선형가속기를 통해 생성되며 일정한 세기의 X-선량이 시간의 변화에 관계없이 안정적으로 유지되어야 한다. 만약 발생되는 X-선의 세기가 일정하지 않다면 영상의 해상도와 대비도 등에 영향을 미칠 수 있으며 결과적으로 컨테이너 내부의 이상화물에 대한 검사에 영향을 미칠 수 있다. 그러므로 고화질의 영상을 획득하기 위해서는 발생되는 X-선 선량에 대한 지속적인 모니터링이 요구된다. 이와같은 선량 모니터링을 위하여, 본 연구에서는 고에너지 X-선 선량의 변화 측정을 위한 이온전리함 기반의 선량변화 측정장치를 개발하였고 환경변화에 따른 신호처리부의 성능변화를 확인하기 위하여 온도와 습도 변화에 의한 측정값의 변화를 관찰하였다. 또한, 고에너지 X-선 발생장치에서 발생되는 선량의 변화에 따른 응답특성변화를 측정함으로써 개발한 X-선 선량측정장치의 검증을 수행하였다. 측정결과 온도와 습도의 변화에 따른 성능의 차이가 크게 나타나지 않았으며 입사되는 선량의 변화에 따른 출력의 변화가 선형적이었다. 그러므로 개발한 이온전리함 기반의 선량변화측정장치는 고에너지 X-선의 선량변화의 측정에 적용하기에 적합함을 알 수 있었다.