• 제목/요약/키워드: X-ray image enhancement

검색결과 50건 처리시간 0.027초

The Study of Acquisition Signal Distortion due to Edge Effect in Direct Digital Radiography System

  • Cho, Jin-Wook;Choi, Jang-Yong;Mun, Chi-Woona;Lee, Hyung-Won;Nam, Sang-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.179.1-179
    • /
    • 2001
  • Successive image contrast enhancement was used to direct digital radiography system. This system was accurately required acquisition signal in each pixel. But, applied high electric field in a-Se thin film for x-ray conversion layer was caused to acquisition signal distortion, then bring low image contrast. The purpose of this study was to reduce the signal distortion, carried out different electrode size.

  • PDF

이물 객체 탐지 성능 개선을 위한 딥러닝 네트워크 기반 저품질 영상 개선 기법 개발 (Development of deep learning network based low-quality image enhancement techniques for improving foreign object detection performance)

  • 엄기열;민병석
    • 인터넷정보학회논문지
    • /
    • 제25권1호
    • /
    • pp.99-107
    • /
    • 2024
  • 경제성장과 산업 발전에 따라 반도체 제품부터 SMT 제품, 전기 배터리 제품에 이르기 까지 많은 전자통신 부품들의 제조과정에서 발생하는 철, 알루미늄, 플라스틱 등의 이물질로 인해 제품이 제대로 동작하지 않거나, 전기 배터리의 경우 화재를 발생하는 문제까지 심각한 문제로 이어질 가능성이 있다. 이러한 문제를 해결하기 위해 초음파나 X-ray를 이용한 비파괴 방법으로 제품 내부에 이물질이 있는지 판단하여 문제의 발생을 차단하고 있으나, X-ray 영상을 취득하여 이물질이 있는지 판정하는 데에도 여러 한계점이 존재한다. 특히. 크기가 작거나 밀도가 낮은 이물질들은 X-Ray장비로 촬영을 하여도 보이지 않는 문제점이 있고, 잡음 등으로 인해 이물들이 잘 안 보이는 경우가 있으며, 특히 높은 생산성을 가지기 위해서는 빠른 검사속도가 필요한데, 이 경우 X-ray 촬영시간이 짧아지게 되면 신호 대비 잡음비율(SNR)이 낮아지면서 이물 탐지 성능이 크게 저하되는 문제를 가진다. 따라서, 본 논문에서는 저화질로 인해 이물질을 탐지하기 어려운 한계를 극복하기 위한 5단계 방안을 제안한다. 첫번째로, Global 히스토그램 최적화를 통해 X-Ray영상의 대비를 향상시키고, 두 번째로 고주파 영역 신호의 구분력을 강화하기 위하여 Local contrast기법을 적용하며, 세 번째로 Edge 선명도 향상을 위해 Unsharp masking을 통해 경계선을 강화하여 객체가 잘 구분되도록 한다, 네 번째로, 잡음 제거 및 영상향상을 위해 Resdual Dense Block(RDB)의 초고해상화 방법을 제안하며, 마지막으로 Yolov5 알고리즘을 이용하여 이물질을 학습한 후 탐지한다. 본 연구에서 제안하는 방식을 이용하여 실험한 결과, 저밀도 영상 대비 정밀도 등의 평가기준에서 10%이상의 성능이 향상된다.

Multispectral X-ray imaging to distinguish among dental materials

  • Peter, Ann-Christin;Schnaubelt, Matthias;Gente, Michael
    • Imaging Science in Dentistry
    • /
    • 제47권4호
    • /
    • pp.247-254
    • /
    • 2017
  • Purpose: Dual-energy X-ray imaging is widely used today in various areas of medicine and in other applications. However, no similar technique exists for dental applications. In this study, we propose a dual-energy technique for dental diagnoses based on voltage-switching. Materials and Methods: The method presented in this study allowed different groups of materials to be classified based on atomic number, thereby enabling two-dimensional images to be colorized. Computer simulations showed the feasibility of this approach. Using a number of different samples with typical biologic and synthetic dental materials, the technique was applied to radiographs acquired with a commercially available dental X-ray unit. Results: This technique provided a novel visual representation of the intraoral environment in three colors, and is of diagnostic value when compared to state-of-the-art grayscale images, since the oral cavity often contains multiple permanent foreign materials. Conclusion: This work developed a technique for two-dimensional dual-energy imaging in the context of dental applications and showed its feasibility with a commercial dental X-ray unit in simulation and experimental studies.

최적화된 고주파 강조 필터를 이용한 의료영상의 개선 (An Enhancement of Medical Image Using Optimized High-Frequency Emphasis Filter)

  • 신충호;정채영
    • 한국정보통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.698-704
    • /
    • 2013
  • 영상개선을 위한 영상처리는 응용분야에 따라서 동일한 알고리즘이 각각 다르게 적용되므로 응용분야에 적합한 최적값이 필요하다. 본 논문에서는 X선 의료영상분야에 고주파통과 필터를 적용해서 에지영역을 개선하였고, 결과영상에 상수승수와 오프셋을 더하여 에지영역 및 평탄영역의 컨트라스트를 향상시켰다. 그러므로, 의료영상을 최적화시키기 위해서는 고주파강조필터가 필요함을 알 수 있었다. 또한, 구체적인 최적화 변수값으로는 가우시안 고주파통과필터, 차단주파수의 거리=0.05, 오프셋=0.5 값이다. 마지막으로 이들 최적화 변수값을 적용시켜 시뮬레이션 한 결과, 제안된 방법이 기존 방법들에 비해서 영상의 컨트라스트와 에지부분들을 향상시켰다.

Sparse 표현을 이용한 X 선 흡수 영상 개선 (X-ray Absorptiometry Image Enhancement using Sparse Representation)

  • 김형일;엄원용;노용만
    • 한국멀티미디어학회:학술대회논문집
    • /
    • 한국멀티미디어학회 2012년도 춘계학술발표대회논문집
    • /
    • pp.30-33
    • /
    • 2012
  • 대사성 골 질환인 골다공증(Osteoporosis)의 조기 진단을 위해 X 선 영상에서 골 밀도를 측정하는 방법이 최근 연구되고 있다. 골 밀도는 X 선 영상에서 뼈가 분리되고, 분리된 영역에서의 픽셀에 의해 BMD가 측정되는데, 개선된 영상에서의 정밀한 뼈 추출이 주요한 요소이므로 X 선 영상의 개선은 골다공증의 조기 진단을 위해 필수적이다. 본 논문에서는 sparse 표현법을 도입하여 X 선 영상을 개선시키는 방법을 제안한다. 실험을 통해 제안한 방법의 결과가 기존의 방법인 웨이블릿 BayesShrink에 비해 개선됨을 CNR(Contrast to Noise Ratio)을 통해 확인하였다.

  • PDF

실험적으로 제작한 Videodensitometer의 디지털 영상처리와 임상적 적용에 관한 연구 (DIGITAL IMAGE PROCESSING AND CLINICAL APPLICATION OF VIDEODENSITOMETER)

  • 박관수;이상래
    • 치과방사선
    • /
    • 제22권2호
    • /
    • pp.273-282
    • /
    • 1992
  • The purpose of this study was to propose the utility which was evaluated the digital image processing and clinical application of the videodensitomery. The experiments were performed with IBM-PC/16bit-AT compatible, video camera(CCdtr55, Sony Co., Japan), an color monitor(MultiSync 3D, NEC, Japan) providing the resolution of 512×480 and 64 levels of gray. Sylvia Image Capture Board for the ADC(analog to digital converter) was used, composed of digitized image from digital signal and the radiographic density was measured by 256 level of gray. The periapical radiograph(Ektaspeed EP-21, Kodak Co., U. S. A) which was radiographed dried human mandible by exposure condition of 70 kVp and 48 impulses, was used for primary X-ray detector. And them evaluated for digitzed image by low and high pass filtering, correlations between aluminum equivalent values and the thickness of aluminum step wedge, aluminum equivalent values of sound enamel, dentin, and alveolar bone, the range of diffuse density for gray level ranging from 0 to 255. The obtained results were as follows: 1. The edge between aluminum steps of digitized image were somewhat blurred by low pass filtering, but edge enhancement could be resulted by high pass filtering. Expecially, edge enhancement between distal root of lower left 2nd molar and alveolar lamina dura was observed. 2. The correlation between aluminum equivalent values and the thickness of aluminum step wedge was intimated, yielding the coefficient of correlation r=0.9997(p<0.00l), the regression line was described by Y=0.9699X+0.456, and coefficient of variation amounting to 1.5%. 3. The aluminum equivalent values of sound enamel, dentin, and alvolar bone were 15.41㎜, 12.48㎜, 10.35㎜, respectively. 4. The range of diffuse density for gray level ranging from 0 to 255 was wider enough than that of photodenstiometer to be within the range of 1-4.9.

  • PDF

CT 이미지 세그멘테이션을 위한 3D 의료 영상 데이터 증강 기법 (3D Medical Image Data Augmentation for CT Image Segmentation)

  • 고성현;양희규;김문성;추현승
    • 인터넷정보학회논문지
    • /
    • 제24권4호
    • /
    • pp.85-92
    • /
    • 2023
  • X-ray, Computed Tomography (CT), Magnetic Resonance Imaging (MRI)과 같은 의료데이터에서 딥러닝을 활용해 질병 유무 판별 태스크와 같은 문제를 해결하려는 시도가 활발하다. 대부분의 데이터 기반 딥러닝 문제들은 높은 정확도 달성과 정답과 비교하는 성능평가의 활용을 위해 지도학습기법을 사용해야 한다. 지도학습에는 다량의 이미지와 레이블 세트가 필요하지만, 학습에 충분한 양의 의료 이미지 데이터를 얻기는 어렵다. 다양한 데이터 증강 기법을 통해 적은 양의 의료이미지와 레이블 세트로 지도학습 기반 모델의 과소적합 문제를 극복할 수 있다. 본 연구는 딥러닝 기반 갈비뼈 골절 세그멘테이션 모델의 성능 향상과 효과적인 좌우 반전, 회전, 스케일링 등의 데이터 증강 기법을 탐색한다. 좌우 반전과 30° 회전, 60° 회전으로 증강한 데이터셋은 모델 성능 향상에 기여하지만, 90° 회전 및 ⨯0.5 스케일링은 모델 성능을 저하한다. 이는 데이터셋 및 태스크에 따라 적절한 데이터 증강 기법의 사용이 필요함을 나타낸다.

고주파 강조필터를 이용한 의료영상의 화질향상을 위한 최적화 방법 (A Visual Quality Enhancement of Medical Image Using Optimized High-Frequency Emphasis Filter)

  • 신충호;정채영
    • 한국정보통신학회논문지
    • /
    • 제18권7호
    • /
    • pp.1681-1685
    • /
    • 2014
  • 의료영상의 화질이 진단의 정확성에 중요한 요소이다. 그러므로 의료영상의 화질을 향상시킬 수 있는 방법들이 연구되어져 왔다. 그 중에서 주파수 도메인 필터가 영상의 화질을 향상시킬 수 있는 강력한 도구이다. 본 논문에서는 X선 의료영상에 기존의 고주파통과 필터에 최적값을 적용해서 에지영역을 개선하였고, 결과영상에 기존의 고주파 강조 필터에 최적값을 사용하여 에지영역 및 평탄영역의 대비를 향상시켰다. 마지막으로, 최소평균제곱오차필터를 사용해서 결과영상에 잡음을 최소화했다. 결과적으로, 제안된 방법이 기존 필터들에 비해서 영상의 대비와 에지부분들을 향상시켰으며, 더불어 잡음제거의 효과를 보였다.

척추 자기 공명 영상에서 특징 벡터에 기반 한 디스크 질환의 자동 인식 (Automatic Disk Disease Recognition based on Feature Vector in T-L Spine Magnetic Resonance Image)

  • 홍재성;이성기
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권3호
    • /
    • pp.233-242
    • /
    • 1998
  • 본 논문에서는 척추 자기공명영상에 대하여 자동적으로 질환에 관련된 특징 벡터들을 추출하고 디스크 질환을 인식하는 방법을 제안하였다. 척추 자기공명영상은 절단면에 따라 시상 단면 영상과 축 단면 영상으로 나누어 진다. 두가지 영상에서 질환에 관련된 특징 벡터를 추출하여 질환의 유무와 종류를 인식하는데 사용하였다. 시상 단면 영상에서는 각 부위에 해당하는 영역의 동질성을 이용하여 디스크 부분을 추출한 후 영역레이블링 과정을 통해 전체적인 크기와 돌출 정도를 구해서 질환을 나타내는 특징으로 이용하였다. 축 단면 영상에서는 템플릿 정합을 이용하여 디스크 영역을 찾고 경계선을 추출하기 위해 세기와 방향성을 고려한 연산자를 사용했다. 경계선의 모양을 분석해서 디스크 돌출 정도에 관한 수치를 얻었다. 이렇게 얻은 특징벡터들은 유사한 질환을 가진 환자의 영상을 찾기 위한 의료 영상 데이터 베이스에 사용될 수 있으며, 많은 양의 영상에서 질환이 나타나 있는 것을 일차적으로 선별하여 전문의에게 제공하는데 이용될 수 있을 것으로 예상한다.

  • PDF

Computer Tomography and Magnetic Resonance Image Manifestations of Primary Hepatic Neuroendocrine Cell Carcinomas

  • Huang, Juan;Yu, Jian-Qun;Sun, Jia-Yu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권6호
    • /
    • pp.2759-2764
    • /
    • 2014
  • Aim: This study aims to investigate the manifestation of CT, MRI and dynamic enhanced scans for primary hepatic neuroendocrine cell carcinoma. Methods: CT or MRI arterial and venous phase scan images of 19 cases of pathologically confirmed PHNEC were retrospectively analyzed. Results: 14 cases (73.68%) with single lesion, 5 cases (26.3%) with multiple lesions, with an average diameter of 13.2 cm. Some 12 cases (63.16%) showed inhomogeneous enhancement, seven cases (36.8%) showed homogeneous enhancement, 13 cases (68.4%) demonstrated significant enhancement in the arterial phase, 13 cases (68.4%) had significantly enhanced portal venous phase including 7 cases (36.8 %) with portal venous phase density or signal above the arterial phase and 5 cases (26.3%) with the portal vein density or signal below the arterial phase. Seven cases (36.8%) had continued strengthened separate shadows in the center of the lesion. Thrombosis were not seen in portal veins. Conclusion: CT and MRI images of liver cell neuroendocrine carcinoma have certain characteristics that can provide valuable information for diagnosis and differential diagnosis.