• 제목/요약/키워드: X-ray field

검색결과 1,749건 처리시간 0.03초

A Magnetization Study of Prussian-blue Analogue NaxMny[Fe(CN)6]

  • Minh, Nguyen Van;Phu, Phung Kim;Thuan, Nguyen Minh;Yang, In-Sang
    • Journal of Magnetics
    • /
    • 제13권4호
    • /
    • pp.149-152
    • /
    • 2008
  • In this report, we present the results of a study on the effects of the particle size on the properties of the Prussian blue (PB) analog $Na_xMn_y[Fe(CN){_6}]$. A novel synthesis method of the $Na_xMn_y[Fe(CN){_6}]$ nano-particles using an organic solvent, formamide, is employed. The size of the PB particles is found to be 100-150 nm for the samples prepared in the formamide solvent, which is much smaller than that of the samples prepared using water only. The broadening of the X-ray diffraction peaks of the nano-sized PB samples is attributed to the lattice disorder and a dramatic reduction in the particle size. The compositions of the samples are confirmed by an energy-dispersive X-ray analysis (EDAX), and the result proves that the samples are actually $Na_xMn_y[Fe(CN){_6}]$ Prussian blue. The UV-vis spectra show a broad intervalence charge-transfer (CT) band in the visible region between 400 and 700 nm, and the absorption decreases abruptly in the green region for the nano-sized PB sample. A divergence between the field cooled (FC) and zero field cooled (ZFC) magnetization curves is observed for the nano-sized PB sample at 11 K, indicating that nanoparticles in the sample are single domain superparamagnets with a blocking temperature of 11 K. Our results reveal that the nano-sized PB samples show significantly different optical and magnetic properties than those of the bulk PB samples.

CHANDRA OBSERVATIONS OF THE AKARI NEP DEEP FIELD

  • Miyaji, T.;Krumpe, M.;Brunner, H.;Ishigaki, T.;Hanami, H.;Markowitz, A.;Takagi, T.;Goto, T.;Malkan, M.A.;Matsuhara, H.;Pearson, C.;Ueda, Y.;Wada, T.
    • 천문학논총
    • /
    • 제32권1호
    • /
    • pp.235-237
    • /
    • 2017
  • The AKARI NEP Deep Field Survey is an international multiwavelength survey over $0.4deg^2$ of the sky. This is the deepest survey made by the InfraRed Camera (IRC) of the infrared astronomical satellite AKARI with 9 filters continuously covering the $2-25{\mu}m$ range, including three filters in the Spitzer gap between the IRAC and MIPS coverages. This enabled us to make sensitive MIR detection of AGN candidates at z~ 1, based on hot dust emission in the AGN torus. It is also efficient in detecting highly obscured Compton-thick AGN population. In this article, we report the first results of X-ray observations on this field. The field was covered by 15 overlapping Chandra ACIS-I observations with a total exposure of ~300 ks, detecting ${\approx}450$ X-ray sources. We utilize rest-frame stacking analysis of the MIR AGN candidates that are not detected individually. Our preliminary analysis shows a marginal detection of the rest-frame stacked Fe $k{\alpha}$ line from our strong Compton-thick candidates.

수직형 다엽 콜리메이터의 방사선 조사면 크기 결정을 통한 유용성 연구 (Feasibility Study of Vertical Multileaf Collimator for Determination of Irradiation Size)

  • 이창열;손기홍;신상훈;박승우;이동한;정해조;최문식;오원용;김금배;양광모;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제22권1호
    • /
    • pp.3-11
    • /
    • 2011
  • 본 연구에서는 제작한 수직형 다엽 콜리메이터를 이용하여 방사선치료에 사용되는 Co-60 감마선 및 6 MV 엑스선의 조사면 크기와 모양을 결정하고 동일한 모양 및 크기의 조사면을 납차폐체로 결정하여 방사선 조사면 내 선량분포 특성을 상호 분석하여 수직형 다엽 콜리메이터의 방사선 조사면 크기 결정에 관한 유용성을 평가하였다. 이를 위해 이온전리함, 유리선량계, 방사선크로믹 필름을 사용하여 선량측정 실험을 수행하였다. Co-60 감마선과 6 MV 엑스선에 대하여 기준조사면의 이온전리함 측정결과 수직형 다엽 콜리메이터의 빔 중심축 선량값이 납차폐체의 선량값보다 각각 5.1%, 4.2% 높게 측정되었다. 그리고 Co-60 감마선에 대한 4개 조사면(기준 조사면, 원형, 삼각형, 십자형)의 유리선량계 측정 결과는 수직형 다엽 콜리메이터의 선량값이 납차폐체의 선량값보다 각각 2.2%, 7.8%, 7.2%, 4.0% 높게 측정되었고, 6 MV 엑스선에 대하여는 수직형 다엽 콜리메이터의 선량값이 납차폐체의 선량값보다 각각 6.7%, 6.2%, 3.8%, 6.2% 높게 측정되었다. 방사선크로믹 필름에서 차폐체의 선량분포곡선 중 최대선량의 80%에서 20%까지의 거리를 나타내는 반음영 크기는 모든 조사면에서 수직형 다엽 콜리메이터의 반음영 크기가 납차폐체보다 Co-60의 경우 2.0~3.5 mm, 6 MV 엑스선의 경우 0.5~1.0 mm 작게 나타났으며 이는 제작한 수직형 다엽 콜리메이터가 임상에 사용되었을 때 반음영의 크기를 납차폐체보다 줄일 수 있음으로써 치료 조사면적 결정시 차폐물의 반음영으로 생기는 방사선치료체적(Treatment Volume, TV)을 최소화시킬 수 있는 장점이 있으리라 판단된다. 아울러 2차원 및 3차원 방사선치료 시 본 다엽 콜리메이터를 이용하여 다양한 방사선치료 조사면을 간편하게 결정하여 사용할 수 있으리라 생각된다.

현장 및 실내실험을 이용한 매립지 전단활동면 추정에 대한 연구 (Estimation of Shear Plane at Failed Landfill Using Field and Laboratory Tests)

  • 최호성;김태형;김성욱
    • 지질공학
    • /
    • 제29권3호
    • /
    • pp.315-327
    • /
    • 2019
  • 매립지 비탈면의 전단파괴 해석은 일반적으로 역해석 통한 파괴원호활동면을 추정하고 안전율을 산정한다. 그러나 현장 상황과 해석을 통해 산정된 원호파괴면 사이에는 서로 상이한 경우가 존재한다. 그래서 연구에서는 매립장에서 발생된 파괴면을 정확히 판정할 수 있는 근거가 될 수 있는 지반내 전단활동 파괴면의 위치를 파악하기 위하여 연구를 실시하였다. 이를 위해 콘관입시험, 시추조사, 연 X-선 영상 분석, 밀도검층, 초음파주사검층 등의 현장 및 실내실험을 실시하였다. 조사 결과 콘관입시험 결과로 부터 관입저항치, 간극수압, 비배수전단강도가 주변 구간에 비해 현저히 감소하는 특정 구간을 확인할 수 있었고 지반내의 전단파괴면으로 예측된다. 추가 확인을 위해 실시된 연 X-선 영상 판독 결과 예상 활동 지반층에서 층리가 교란된(경사진) 것으로 나타났다. 밀도검층과 초음파주사검층 결과에서도 유사하게 파괴면 위치에서 다른 위치와는 다른 경향을 보이는 구간을 확인하였다. 본 연구에서 사용된 방법으로 지반내 파괴면 추정이 가능함을 알 수 있었다.

Y2O3 : Eu3+ 적색 형광체의 발광특성 (Luminescent Characteristics and Synthesis of Eu3+- Doped Y2O3 Red Phosphors)

  • 유일
    • 한국재료학회지
    • /
    • 제31권10호
    • /
    • pp.582-585
    • /
    • 2021
  • Y2O3:Eux (x = 0.005, 0.01, 0.02, 0.03, 0.05, 0.1 mol) phosphors are synthesized with different concentrations of Eu3+ ions by solvothermal method. The crystal structure, surface and optical properties of the Eu doped Y2O3 phosphors are investigated using X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), and photoluminescence (PL) and photoluminescence excitation (PLE) analyses. From X-ray diffraction (XRD) results, the crystal structure of the Eu doped Y2O3 phosphor is found to be cubic. The maximum emission spectra of the Eu doped Y2O3 phosphors are observed at 0.05 mol Eu3+ concentration. The photoluminescence of 615 nm in the Eu doped Y2O3 phosphors is associated with 5D07F2 transition of Eu3+ ions. The decrease in emission intensity of 0.1 mol Eu doped Y2O3 is interpreted by concentration quenching. The International Commission on Illumination (CIE) coordinates of 0.05 mol Eu doped Y2O3 phosphor are X = 0.6547, Y = 0.3374.

In 이온을 첨가한 $EuFeO_{3}$의 결정구조 및 자기적 성질 (The Crystallograpic and Magnetic Properties of EuFeO3 Doped with in ions)

  • 김정기;서정철;한은주
    • 한국자기학회지
    • /
    • 제4권4호
    • /
    • pp.335-339
    • /
    • 1994
  • $Eu(Fe_{1-x}In_{x})O_{3}$ (x=0, 0.03과 0.05)의 결정구조와 자기적 성질을 상온에서의 X선 회절, $M\"{o}ssbauer$ 분광학 및 자기이력곡선 측정 방법에 의해서 연구하였다. X선 회절 분석 결과는 모든 시료가 orthorhombic 결정구조를 가지며, 단위포의 체적은 x=0을 제외하면 In 농도의 증가에 따라 증가함을 보인다. $M\"{o}ssbauer$ 스펙트럼은 두셋트 여섯 lines을 갖는다는 가정하에 분석하였다. 분석 결과는 각 셋트에서의 초미세 자기장은 x의 증가에 따라 감소하였다. 본 연구의 시료에서 공명 흡수선의 반폭이 x의 증 가에 따라 증가함은, 측정 data가 $Fe^{3+}$ 이온 주위 z개의 $In^{3+}$ 이온이 존재할 확률 분포, $_{n}P_{z}(x)$에 비례하는 초미세 구조에 의한 흡수선의 합으로 이루어졌음을 의미한다. 자기이력 곡선에서 $M_{s}$$H_{c}$는 각각 X의 증가에 따라 감소와 증가를 보인다.

  • PDF

FACS법에 의한 Fe-Al계 금속간화합물의 제조시 통전방식의 영향 (The Effects of Current Adjustment on the Preparation of Fe-Al Intermetallic Compounds by Field-Activated Combustion Synthesis)

  • 윤기석;정중채;원창환
    • 한국재료학회지
    • /
    • 제9권7호
    • /
    • pp.680-687
    • /
    • 1999
  • Fe-Al계 금속간화합물이 FACS (Field-Activated Combustion Synthesis) 법에 의해 제조되었다. 이 계의 반응에 있어서 조성 (Fe:Al=3 : 1,2 : 1, 1 : 1.1 : 2, 1 : 3) , 성형압력 (150, 250, 350MPa), 저항 등이 조사되었는데. Al의 몰비, 성형압력, 전기장의 세가가 증가함에 따라서 연소온도와 연소속도는 증가하였다. 또한 이 계에 있어서 전류적용방식에 따른 반응에 대한 영향이 조사되었다. 전기장이 적용되지 않는 경우, 반응이 일어나기 위해서는 예열이 필요하였고, 예열을 하였을 경우라도 그 반응은 불안정연소파를 나타내어 완전한 반응이 이루어지지 않았다. 생성물은 X-ray, SEM, EDXS를 사용하여 그 구조와 조성을 관찰하였다

  • PDF

Radiation Exposure of the Hand and Chest during C-arm Fluoroscopy-Guided Procedures

  • Jung, Cheol Hee;Ryu, Jae Sung;Baek, Seung Woo;Oh, Ji Hye;Woo, Nam Sik;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • 제26권1호
    • /
    • pp.51-56
    • /
    • 2013
  • Background: The C-arm fluoroscope is an essential tool for the intervention of pain. The aim of this study was to investigate the radiation exposure experienced by the hand and chest of pain physicians during C-arm fluoroscopy-guided procedures. Methods: This is a prospective study about radiation exposure to physicians during transforaminal epidural steroid injection (TFESI) and medial branch block (MBB). Four pain physicians were involved in this study. Data about effective dose (ED) at each physician's right hand and left side of the chest, exposure time, radiation absorbed dose (RAD), and the distance from the center of the X-ray field to the physician during X-ray scanning were collected. Results: Three hundred and fifteen cases were included for this study. Demographic data showed no significant differences among the physicians in the TFESIs and MBBs. In the TFESI group, there was a significant difference between the ED at the hand and chest in all the physicians. In physician A, B and C, the ED at the chest was more than the ED at the hand. The distance from the center of the X-ray field to physician A was more than that of the other physicians, and for the exposure time, the ED and RAD in physician A was less than that of the other physicians. In the MBB group, there was no difference in the ED at the hand and chest, except for physician D. The distance from the center of the X-ray field to physician A was more than that of the other physicians and the exposure time in physician A was less than that of the other physicians. Conclusions: In conclusion, the distance from the radiation source, position of the hand, experience and technique can correlate with the radiation dose.

RF Magnetron Sputtering 및 Evaporation을 이용하여 증착한 CdTe 박막의 물성평가

  • 김민제;조상현;송풍근
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.345-345
    • /
    • 2012
  • 최근 의료산업에서는 고해상도 및 동영상 구현이 가능한 직접 방식의 X-선 검측센서에서 X-ray 흡수효율이 좋은 반도체 센서(CdTe, CdZnTe 등)와 성숙된 기술, 집적효율이 뛰어난 CMOS 공정을 이용한 제품을 출시하여 대면적화 및 고집적화가 가능하게 되어 응용분야가 점차 확대되고 있는 추세이다. 하지만 이 역시 고 성능의 X-선 동영상 구현을 위해서는 고 해상도 문제, 검출효율 문제, 대면적화의 어려움이 있다. 기존의 X-선 광 도전층의 증착은 증착 속도와 박막 품질에서 우수한 Evaporation 법이 사용되고 있다. 한편, 대면적에 균일한 박막형성이 가능하기 때문에 양산성에서 우월성을 가지는 sputtering법의 경우, 밀도가 높은 소결체 타겟의 제조가 힘들뿐만 아니라 증착 속도가 낮아 장시간 증착 시 낮은 소결밀도로 인한 타겟 Particle 영향으로 인해서 대 면적에 고품질의 박막을 형성하기가 어렵다. 하지만 최근 소결체 타겟 제조기술 발달과 함께, 대면적화와 장시간 증착에 대한 어려움이 해결되고 있어 sputtering 법을 이용한 고품질 박막 제조 기술의 연구가 시급한 실정이다. 본 연구에서는 $50{\times}50$ mm 크기의 non-alkali 유리기판(Corning E2000) 위에 Evaporation과 RF magnetron sputtering을 사용하여 다양한 기판온도 (RT, 100, 200, 300, $350^{\circ}C$)에서 $1{\mu}m$의 두께로 CdTe 박막을 증착하였다. RF magnetron sputtering의 경우 CdTe 단일 타겟(50:50 at%)을 사용하였으며 Base pressure는 약 $5{\times}10^{-6}$ Torr 이하까지 배기하였고, Working pressure는 약 $7.5{\times}10^{-3}$ Torr에서 증착하였다. 시편과 기판 사이의 거리는 70 mm이며 RF 파워는 150 W로 유지하였다. CdTe 박막의 미세구조는 X-ray diffraction (XRD, BRUKER GADDS) 및 Field Emission Scanning Electron Microscopy (FE-SEM, Hitachi)를 사용하여 측정하였다. 또한, 조건별 박막의 조성은 Energy Dispersive X-ray Spectroscopy (EDS, Horiba, 7395-H)을 사용하여 평가하였다. X-선 동영상 장치의 구현을 위해서는 CdTe 다결정 박막의 높은 흡수효율, 전하수집효율 및 SNR (Signal to Noise Ratio) 등의 물성이 요구된다. 이러한 물성을 나타내기 위해서는 CdTe 박막의 높은 결정성이 중요하다. Evaporation과 RF magnetron sputtering로 제작된 CdTe 박막은 공정 온도가 증가함에 따라 기판상에 도달하는 스퍼터 원자의 에너지 증가로 인해서 결정립이 성장한 것을 확인할 수 있었다. 따라서 CdTe 박막이 직접변환방식 고감도 X-ray 검출기 광도 전층 역할을 수행할 수 있을 것으로 기대된다.

  • PDF

Material Discrimination Using X-Ray and Neutron

  • Jaehyun Lee;Jinhyung Park;Jae Yeon Park;Moonsik Chae;Jungho Mun;Jong Hyun Jung
    • Journal of Radiation Protection and Research
    • /
    • 제48권4호
    • /
    • pp.167-174
    • /
    • 2023
  • Background: A nondestructive test is commonly used to inspect the surface defects and internal structure of an object without any physical damage. X-rays generated from an electron accelerator or a tube are one of the methods used for nondestructive testing. The high penetration of X-rays through materials with low atomic numbers makes it difficult to discriminate between these materials using X-ray imaging. The interaction characteristics of neutrons with materials can supplement the limitations of X-ray imaging in material discrimination. Materials and Methods: The radiation image acquisition process for air-cargo security inspection equipment using X-rays and neutrons was simulated using a GEometry ANd Tracking (Geant4) simulation toolkit. Radiation images of phantoms composed of 13 materials were obtained, and the R-value, representing the attenuation ratio of neutrons and gamma rays in a material, was calculated from these images. Results and Discussion: The R-values were calculated from the simulated X-ray and neutron images for each phantom and compared with those obtained in the experiments. The R-values obtained from the experiments were higher than those obtained from the simulations. The difference can be due to the following two causes. The first reason is that there are various facilities or equipment in the experimental environment that scatter neutrons, unlike the simulation. The other is the difference in the neutron signal processing. In the simulation, the neutron signal is the sum of the number of neutrons entering the detector. However, in the experiment, the neutron signal was obtained by superimposing the intensities of the neutron signals. Neutron detectors also detect gamma rays, and the neutron signal cannot be clearly distinguished in the process of separating the two types of radiation. Despite these differences, the two results showed similar trends and the viability of using simulation-based radiation images, particularly in the field of security screening. With further research, the simulation-based radiation images can replace ones from experiments and be used in the related fields. Conclusion: The Korea Atomic Energy Research Institute has developed air-cargo security inspection equipment using neutrons and X-rays. Using this equipment, radiation images and R-values for various materials were obtained. The equipment was reconstructed, and the R-values were obtained for 13 materials using the Geant4 simulation toolkit. The R-values calculated by experiment and simulation show similar trends. Therefore, we confirmed the feasibility of using the simulation-based radiation image.