• Title/Summary/Keyword: X-ray equipment

Search Result 310, Processing Time 0.023 seconds

Shape Reconstruction of Solder Joints on PCB using Iterative Reconstruction Technique (반복복원 기법을 이용한 전자회로기판의 납땜부 형상 복원)

  • 조영빈;권대갑
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.3
    • /
    • pp.353-362
    • /
    • 1999
  • This paper presents a shape reconstruction method for automatic inspection of the solder joints on PCBs using X-ray. Shape reconstruction from X-ray radiographic image has been very important since X-ray equipment was used for improving the reliability of inspection result. For this purpose there have been lots of previous works using tomography, which reconstructs the correct shape, laminography or tomosynthesis, which are very fast algorithm. Latter two methods show outstanding performance in cross-sectional image reconstruction of lead type component, but they are also known to show some fatal limitations to some kinds of components such as BGA, because of shadow effect. Although conventional tomography does not have any shadow effect, the shape of PCB prohibits it from being applied to shape reconstruction of solder joints on PCB. This paper shows that tomography using Iterative Reconstruction Technique(IRT) can be applied to this difficult problem without any limitations. This makes conventional radiographic instrument used for shape reconstruction without shadow effect. This means that the new method makes cost down and shadow-free shape reconstruction. To verify the effectiveness of IRT, we develop three dimensional model of BGA solder ball, make projection model to obtain X-ray projection data. and perform a simulation study of shape reconstruction. To compare the performance of IRT with that of conventional laminography or tomosynthesis, reconstruction data are reorganized and error analysis between the original model are also performed.

  • PDF

Rapid Stitching Method of Digital X-ray Images Using Template-based Registration (템플릿 기반 정합 기법을 이용한 디지털 X-ray 영상의 고속 스티칭 기법)

  • Cho, Hyunji;Kye, Heewon;Lee, Jeongjin
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.6
    • /
    • pp.701-709
    • /
    • 2015
  • Image stitching method is a technique for obtaining an high-resolution image by combining two or more images. In X-ray image for clinical diagnosis, the size of the imaging region taken by one shot is limited due to the field-of-view of the equipment. Therefore, in order to obtain a high-resolution image including large regions such as a whole body, the synthesis of multiple X-ray images is required. In this paper, we propose a rapid stitching method of digital X-ray images using template-based registration. The proposed algorithm use principal component analysis(PCA) and k-nearest neighborhood(k-NN) to determine the location of input images before performing a template-based matching. After detecting the overlapping position using template-based matching, we synthesize input images by alpha blending. To improve the computational efficiency, reduced images are used for PCA and k-NN analysis. Experimental results showed that our method was more accurate comparing with the previous method with the improvement of the registration speed. Our stitching method could be usefully applied into the stitching of 2D or 3D multiple images.

The Performance Test of Anti-scattering X-ray Grid with Inclined Shielding Material by MCNP Code Simulation

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.111-115
    • /
    • 2016
  • Background: The scattered photons cause reduction of the contrast of radiographic image and it results in the degradation of the quality of the image. In order to acquire better quality image, an anti-scattering x-ray gird should be equipped in radiography system. Materials and Methods: The X-ray anti-scattering grid of the inclined type based on the hybrid concept for that of parallel and focused type was tested by MCNP code. The MCNPX 2.7.0 was used for the simulation based test. The geometry for the test was based on the IEC 60627 which was an international standard for diagnostic X-ray imaging equipment-Characteristics of general purpose and mammographic anti-scatter grids. Results and Discussion: The performance of grids with four inclined shielding material types was compared with that of the parallel type. The grid with completely tapered type the best performance where there were little performance difference according to the degree of inclination. Conclusion: It was shown that the grid of inclined type had better performance than that of parallel one.

Internal Defects Inspection of Die-cast Parts via the Comparison of X-ray CT Image and CAD Data (CAD 데이터 및 엑스레이 CT이미지 비교를 통한 다이캐스팅 부품의 내부 결함 검사방법)

  • Hong, Gyeong Taek;Shim, Jae Hong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.1
    • /
    • pp.27-34
    • /
    • 2018
  • Industrially, die-casting products are formed through casting, and so the methods to inspect the defects inside them are very restrictive. External inspection methods including visual inspection, sampling judgment, etc. enables researchers to inspect possible external defects, but x-ray inspection equipment has been generally used to inspect internal ones. Recently, they have been also applying three-dimensional internal inspections using CT equipment. However, they have their own limitations in applying to the use of industrial inspection due to limited detection size and long calculation time. To overcome the above problems, this paper has suggested a method to inspect internal defects by comparing the CAD data of the product to be inspected with the 3D data of the CT image. In this paper, we proposed a method for fast and accurate inspection in three dimensions by applying x-ray inspection to find internal defects in industrial parts such as aluminum die casting products. To show the effectiveness of the proposed method, a series of experiments have been carried out.

A Study on Stereo Visualization of the X-ray Scanned Image Based on Dual-line Sensors (듀얼센서 기반 X-선 검색영상 스테레오 가시화 연구)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Park, Jong-Won;Lim, Yong-Gon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.9
    • /
    • pp.2083-2090
    • /
    • 2010
  • This paper presents a 3-D visualization technique using stereo radioactive images to provide efficient inspection of fast moving cargo objects. The proposed technique can be used for such objects which CT or MRI cannot inspect due to restricted scan environment. Stereo radioactive images are acquired from a specially designed equipment which consists of a X-ray source, linear radioactive sensors, and a moving stage. Two radioactive sensors are installed so that rectified stereo X-ray images of objects are acquired. Using the stereo X-ray images, we run a matching algorithm to find the correspondences between the images and reconstruct 3-D shapes of real objects. The objects are put in a parallelepiped box to simulate cargo inspection. Three real objects are tested and reconstructed. Due to the inherent ambiguity in the stereo X-ray images, we reconstruct 3-D shapes of the edges of the objects. The experimental results show the proposed technique can provide efficient visualization for cargo inspection.

A Study of Electron Paramagnetic Resonance of Sugar Irradiated X-ray (X-선에 조사된 설탕의 전자 상자성 공명 연구)

  • Ok, Chi-Il;Son, Phil-Kook;Heo, Kyoung-Chan;Shon, Jong-Gi;Lee, In;Kim, Jang-Whan
    • Journal of radiological science and technology
    • /
    • v.23 no.2
    • /
    • pp.39-42
    • /
    • 2000
  • When ordinary sugar is exposed to ionizing radiation, a number of free radical are created in sugar, and Electron Paramagnetic Resonance (EPR) signal appears from the sugar because of the paramagnetic property of free radical. In this paper, EPR signal intensity has been measured in x-ray irradiated sugar for various absorbed doses, irradiated dose up to 50 Gy. The EPR intensity signals are increased as the x-ray irradiation increases. Also, the fading value decreased to about 3% in 30day after the irradiation. Therefore, the sugar is a useful material for emergency dosimeter as the free radical dosimetry with the EPR equipment.

  • PDF

A Study on Development of Guideline on Writing Technical Document for Electrical Medical Devices: Dental X-ray Equipment (치과용엑스선장치의 기술문서 작성을 위한 가이드라인 개발 연구)

  • Lee, Seung-Youl;Kim, Jae-Ryang;Lee, Jun-Ho;Park, Chang-Won
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.651-660
    • /
    • 2016
  • Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts.

The Removal of Silver in the Fixer Wastewater of X-ray Film Using Manganese Dioxide (이산화망간을 이용한 x-ray 필름 정착폐액중의 은 제거)

  • 박정호;오성훈;전용보;임찬섭;박승조
    • Resources Recycling
    • /
    • v.6 no.4
    • /
    • pp.11-16
    • /
    • 1997
  • The wastewater resulted from the process of developing and fuing for x-ray film manufachlring contains a lot of silvercomponent. The average concentation of silver-component is about 1,500 mgA. The wastewater contained silver-component is toxic when it is discharged to the natural ecosystem. So that we must to do pretreatment of wastewater prior to discharge. There are electrolysis. chemical precipitation, and metallic replacement as conventional lreabent proccss of fixer wastewater of x-ray film. Adsorption of silver-component in x-ray fkcr wastewater was carricd out this study. 'Ille manganese dioxide (MDO) reagent and the recovered manganese dioxide (RMDO) from the waste dry-cell were used for adsarbents. Adsorption of silvercomponent was wrried out at the batch and continuous type experimental equipment. The adsorption experiment results were obtained bom silver-component have some diifcrences according to adsorhents. The adsorption results of manganese dioxide reagent (MDO) were better ihan those of waste dry-ccU (RMDO), but the manganese dloxide recovered fmm waste dry-cell (RMDO) will be able la recognized as good adsorbent too.

  • PDF

Amendment of the Inspection Standard for Diagnostic Radiation Equipment Applying IEC 60601-1-3: Medical Electrical Equipment - Part 1-3: General Requirements for Basic Safety and Essential Performance - Collateral Standard: Radiation Protection in Diagnostic X-ray Equipment (KS C IEC60601-1-3: 의료용 전기기기-제1-3부: 기본 안전 및 필수 성능에 관한 일반 요구사항-보조표준: 진단용 X선 장치의 방사선 방어를 적용한 진단용 방사선 발생장치의 검사기준 개선안)

  • Park, Hye-Min;Kim, Jung-Min;Kim, Jung-Su;Kim, Seong-Ok;Choi, Young-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.493-504
    • /
    • 2018
  • The diagnostic radiation equipment is managed in accordance with the "Rules for Safety Management of Diagnostic Radiation Equipment" enacted in 1995. The equipments should be inspected before use and every three years after use in accordance with the [Appendix 1] of the same rule. The inspection standard has been maintained without particular revision since enacted. But, over the past two decades new types of equipments have been manufactured and used. So, it is necessary to revise [Appendix 1] by making inspection items and inspection standards. In this study, we revised the classification system of equipments and reviewed international standards of IEC 60601 series, IEC 61223 series and AAPM TG 18 On-line Report No.03. And identified the problem of current inspection standards. Through this, we revised, deleted and added the inspection items and inspection standard of each equipment to meet the domestic circumstances. As a result of the study, we reorganized the classification system of equipment which are current classified as 5 classes into 22 classes as X-ray system etc. (7 classes), CT system etc. (5 classes) and Dental X-ray system etc. (10 classes). And then, we developed 70 inspection items for 6 types of equipments according to the reorganized classification system of equipments. The inspection items and inspection standards derived from this study have been proposed to the KCDC and will be applied to the revision of the Rule's [Appendix 1]. Therefore, we expect to be used as reference materials for domestic medical center, inspection institutions, and equipment manufacturing import companies.