• Title/Summary/Keyword: X-ray emission

Search Result 1,310, Processing Time 0.03 seconds

Image Quality Improvement through Energy Spectrum Change for X-ray (엑스선 에너지스펙트럼 변경을 통한 영상 화질 향상에 관한 연구)

  • Kim, Gu;Kim, Neung Gyun;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.71-78
    • /
    • 2021
  • When continuous X-ray are used when acquiring and X-ray image, even the same material may not be accurately represented in the image according to the thickness due to various X-ray energies. To solve this problem, the X-ray energy spectrum was changed to improve the image quality. Using SPEKTR v3.0, an X-ray energy spectrum with an additional filter added and a general X-ray energy spectrum using only a unique filter were obtained. Simulation was performed using the obtained X-ray energy spectrum as a radiation source for Geant4 Application for Tomographic Emission (GATE). Using GATE data, an X-ray image with an additional filter and an image reconstructed from and X-ray image without an additional filter were compared and analyzed through a mono energy image of 74 keV. In the case of using the X-ray energy spectrum without using an additional filter, the amount of X-rays transmitted according to the thickness of the same material is different from the amount that decreases according to the thickness of the material. Similar results were obtained as the amount decreased with the material thickness. In other words, a similar result was obtained when the reduced dose was used with a mono energy. When an X-ray image is obtained by changing an X-ray energy spectrum using an additional filter, a more accurate result of transmission of X-rays may be obtained. In radiological examination, it was confirmed that the appropriate use of the additional filter has a great effect on improving the image quality.

Mass and energy of erupting plasma associated with a coronal mass ejection in X-rays and EUV

  • Lee, Jin-Yi;Raymond, John C.;Reeves, Katharine K.;Moon, Yong-Jae;Kim, Kap-Sung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.85.1-85.1
    • /
    • 2015
  • We investigate the mass and energy of erupting plasma observed in X-rays and EUV, which is associated with a coronal mass ejection (CME) and an X-class flare. The erupting plasma was observed by both the X-ray telescope (XRT) on Hinode and the Atmospheric Imaging Assembly (AIA) on Solar Dynamic Observatory (SDO). We estimate the emission measures of the erupting plasma using a differential emission measure method. The plasma erupts with a loop-like structure in X-ray and EUV. We estimate the mass of erupting plasma assuming a cylinder structure. In addition, we estimate the radiative loss, thermal conduction, thermal, and kinetic energies of the eruptive hot plasma. We find that the thermal conduction timescale is much shorter than the duration of the eruption. This result implies that additional heating during the eruption may be required to explain the hot plasma observations in X-rays.

  • PDF

Interactions in Massive Colliding Wind Binaries

  • Corcoran, Michael F.
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.1
    • /
    • pp.93-96
    • /
    • 2012
  • There are observational difficulties determining dynamical masses of binary star components in the upper HR diagram both due to the scarcity of massive binary systems and spectral and photometric contamination produced by the strong wind outflows in these systems. We discuss how variable X-ray emission in these systems produced by wind-wind collisions in massive binaries can be used to constrain the system parameters, with application to two important massive binaries, Eta Carinae and WR 140.

Luminescence of $Y_{2-x}Ce_xSiO_5$ Phosphor

  • Han-Soo Kim;Sahn Nahm;Myong-Ho Kim;Kyung-Su Suh;Jae-Dong Byun
    • The Korean Journal of Ceramics
    • /
    • v.3 no.4
    • /
    • pp.245-248
    • /
    • 1997
  • Photoluminescence (PL) and cathodoluminescence (CL) characteristics of Ce-activated $Y_{2-x}Ce_xSiO_5$ have been investigated as functions of Ce concentration and firing condition. According to the X-ray, PL and CL results, $Y_2SiO_5$ is found to have two phases depending on the firing temperature. For the specimen fired above 127$0^{\circ}C$, the emission band peaked at 395nm with a shoulder at 424 nm under ultraviolet (u.v.) and cathode-ray (c.r.) excitation. However, for the specimen fired below 120$0^{\circ}C$ in air the peak was observed at 424 nm and it shifted to longer wavelength with reduction level. The reduced specimen for x=0.02 showed the brightest emission under u.v. excitation whereas under c.r. excitation the brightest emission was observed for the reduced specimen for x=0.06.

  • PDF

Comparison of Different Techniques for Measurement of Cold Work in Mild Steel

  • Badgujar, B.P.;Jha, S.K.;Goswami, G.L.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.6
    • /
    • pp.616-621
    • /
    • 2003
  • There are various Non-Destructive Evaluation (NDE) techniques used for measurement of residual stresses in material, such as magnetic methods, X-ray diffraction, Ultrasonic velocity measurement etc. The capabilities, applications and limitations of these techniques for evaluation of cold work/plastic deformation were studied and compared. Mild steel plates were subjected to different degree of cold deformation and were analyzed by Magneto-mechanical Acoustic Emission (MAE), Barkhausen Noise (BN) and magnetic properties (hysteresis loop parameters analysis). Further, these specimens were analyzed by X-ray diffraction and ultrasonic velocity measurements. The microhardness measurement and microstructure studies of these cold worked plates were also carried out. The results of all these studies and comparison of different techniques are discussed in this paper.

X-Ray Emission Spectroscopic Analysis for Crystallized Amorphous Silicon Induced by Excimer Laser Annealing

  • John, Young-Min;Kim, Dong-Hwan;Cho, Woon-Jo;Lee, Seok;Kurmaev, E.-Z.
    • Journal of the Optical Society of Korea
    • /
    • v.5 no.1
    • /
    • pp.1-4
    • /
    • 2001
  • The results of investigating $SiL_{2,3}$/ X-ray emission valence spectra of amorphous silicon films irradiated by excimer laser are presented. It is found that laser annealing leads to crystallization of amorphous silicon films and the crystallinity increases with the laser energy density from 250 to 400 mJ/$\textrm{cm}^2$. The vertical structure of the film is investigated by changing the accelerating voltage on the X-ray tube, and the chemical and structural state of Si$_3$N$_4$ buffer layer is found not to be changed by the excimer laser treatment.

Nanotube Shape Variation on the Ti-xNb Alloys with Alloying Elements and Applied Potentials

  • Byeon, In-Seop;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.112-112
    • /
    • 2015
  • The purposed of this work was to determine nanotube shape variation on the Ti-xNb alloys with alloying elements and applied potentials. Samples were prepared by arc melting, followed by followed by homogenization for 12 hr at $1000^{\circ}C$ in argon atmosphere. This study was evaluated the phase and microstructure of Ti-xNb alloys using an X-ray diffraction (XRD) and optical microscopy (OM). The morphology of the samples was investigated with a field-emission scanning electron microscope (FE-SEM) and energy dispersive X-ray spectroscopy (EDS). The nanotube on the alloy surface was formed in 1 M $H_3PO_4$ with small additions of NaF 0.8 wt.%. All anodization treatments were carried out using a scanning potentiostat (Model 362, EG&G, USA) at constant voltage 30 V for 120 min, respectively. The morphology of the samples was investigated with a field-emission scanning electron microscope (FE-SEM) and energy dispersive X-ray spectroscopy (EDS). Surface characteristics of nanotbue formed on Ti-xNb alloys was investigated by potentiodynamic test and potentiostatic in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. It was observed that the changed ${\alpha}$ phase to ${\beta}$ phase with Nb content.

  • PDF

Analysis of a Spun-CNT Based X-ray Source

  • Kim, Hyun Suk;Castro, Edward Joseph D.;Hun, Choong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.639-639
    • /
    • 2013
  • In this research we report the significant contribution of the as-spun multi-walled carbon nanotube (MWCNT) on the x-ray images formation using a low tube voltage x-ray source. The MWCNT, which was used for the fabrication of the spun CNT, was grown using a microwave plasma-enhanced chemical vapor deposition machine. Electrical-optics simulation software was utilized to determine the electron field emission trajectory of the triode-structure-as-spun CNT-based x-ray source. It was shown that a significant amount of converging electrons hit the target anode producing a clear x-ray image. These x-ray images where produced at a small amount of anode current of 0.67 mA at a tube voltage of 5 kV with the gate voltage of 0 V. Also, comparisons of the radiographs at various exposure times of the sample where analyzed with and without an x-ray dose filter. Results showed that spatially-resolved images were formed using the as-spun CNT at a low tube voltage with a $54-{\mu}m$ Al x-ray filter. This study can be used for low-voltage medical applications.

  • PDF

Zinc Sulfide-selenium X-ray Detector for Digital Radiography

  • Park, Ji-Koon;Kang, Sang-Sik;Kim, Jae-Hyung;Mun, Chi-Woong;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.4
    • /
    • pp.16-20
    • /
    • 2002
  • The high bias voltage associated with the thick layer (typically 500-1000 ㎛) of selenium required to have an acceptable x-ray absorption in radiography and fluoroscopy applications may have some practical inconvenience. A hybrid x-ray detector with zinc sulfide-amorphous selenium structure has been developed to improve the x-ray sensitivity of a a-Se based flat-panel digital imaging detector. Photoluminescence(PL) characteristic of a ZnS:Ag phosphor layer showed a light emission peak centered at about 450 nm, which matches the sensitivity spectrum of selenium. The dark current of the hybrid detector showed similar characteristics with that of a a-Se detector. The x-ray sensitivity of hybrid and a-Se x-ray detector was 345 pC/㎠/mR and 295 pC/㎠/mR at an applied voltage of 10 V/㎛, respectively. The purpose of this study was to evaluate the pertinence of a solution using a thin selenium layer, as a photosensitive converter, with a thick coating of silver doped zinc sulfide phosphor.