• Title/Summary/Keyword: X-ray Unit

Search Result 563, Processing Time 0.027 seconds

Radioopacity of Absorbable Plate containing Hydroxyapatite and Gold(Au); A Preliminary Report (Hydroxyapatite와 금(Au)이 혼합된 흡수성 고정판의 방사선비투과성; 예비 실험)

  • Kim, Yong Ha;Nam, Hyun Jae;Lee, Joon Ho;Kim, Kap Joong;Kim, Yeon Jung;Choi, Sik Young
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.419-422
    • /
    • 2008
  • Purpose: Absorbable bone fixation materials for operation of facial bone fracture are composed of poly- lactic acid(PLA) & poly-glycolic acid(PGA). These materials are absorbed after facial bone healing period. Therefore, these materials are harmless in human body. But because of it's radioopacity, the number and the location of the materials are not checked in follow-up X-ray examination. We studied absorbable bone fixation materials checked radiological examination. So, we made the absorbable plate composed of PLA, Hydroxyapatite (HA) and Gold(Au). Methods: Plate 1 was consisted of pure PLA. Plate 2 was consisted of PLA(50%) and HA(50%). Plate 3 - 7 were consisted of PLA(50%), and variable composition of HA & Au. The ratio of Au was as following. From the plate 3 to plate 7, the Au ratio was 1%, 5%, 10%, 17%, and 25%, respectively. Total 3 examinations were used-naked eye examination, simple X-ray examination, and Haunsfield unit of plate in CT examination. Results: Naked eye examination found out that the color of plate 1 was most white. As the Au ratio increases, the color of plate was getting close to khaki color. the radioopacity of plate 2 was similar cortical bone of face in simple X-ray. The Haunsfield unit of cortical bone of face was 1000 HU. Haunsfield unit of titanium plate was 2900 HU. Haunsfield unit of plate 1 through plate 7 were -242, 1489, 1776, 3052, 3092, 3095, and 3095, respectively. Conclusion: Radioopacity of plate 2 was similar to cortical bone of face. In CT examination, Hanusfield unit of plate 2 was similar to Hanusfield unit of cortical bone of face. Hanusfield unit of plate 4 - 7 were similar to Hanusfield unit of titanium plate. So to trace bone fixation materials after facial bone surgery, the best ratio of Au is about 1 - 5%. If this study is applied to facial bone surgery, radiologic follow up would be easy after facial bone surgery.

Research on ANIOS Disinfection Efficiency to Prevent Infection in Radiography Room (방사선촬영실 감염 방지를 위한 에니오설프의 소독효율 연구)

  • Jung, Woo-Chan;Ahn, Ki-Song;Yang, Eun-Ju;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.55-61
    • /
    • 2021
  • In this study, microbes were collected before and after disinfection using ANIOS(ANIOSURF Premium NPC) and compared the areas where the radiological technologist and the patient frequently contacted the chest X-ray. From September 1st to September 7th, 2020. in P Hospital in Deagu, 4 region were collected in a 10×10 size using a sterile cotton swab of the transport medium, and before and after disinfection results were obtained through the colorimetric method. As a result, n the X-ray tube handle Proteus mirabilis, Staphylococcus epidermidis, Bacillus spp., Candida spp., and in the Chin region Proteus mirabilis, Enterococcu faecium, Pseudomonas aeruginosa, NTM, and in the Chest region Proteus mirabilis, Enterococcu faecium, Pseudomonas aeruginosa, and in the Palm region NTM, Candida spp. were detected, and 103 CFU(Colony Forming Unit) or more were measured. After disinfection, only X-ray tube handle was detect Bacillus spp. and more than 102 CFU was measured. Microorganisms found prior to disinfection can cause opportunistic infections, Experimental results showed that Aniosulf(0.25%) is more economical and disinfectant than ethanol(70-90%) and isopropyl alcohol(70-90%). However, further research is needed on the detection of Bacillus spp. resultingly this research is useful basic data of infection control in Radiography room and prevention secondary infections.

X-Ray and NMR Studies of Vanadium(V)-Nitrilotriacetate Complex (바나듐(V)-니크릴로트리아세테이트 착물의 X-선 및 핵자기공명 연구)

  • Lee, Man-Ho;Jeong, Woo-Won
    • Analytical Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.196-202
    • /
    • 1997
  • New vanadium(V) complex, $(NH_4)_2[VO_2NTA]$, has been synthesized and its structure has been determined by solution and solid-state NMR spectroscopies as well as X-ray crystallography. The unit cell of the monoclinic crystals contains four complexes with $a=6.923(1){\AA}$, $b=8.824(2){\AA}$, $c=19.218(11){\AA}$ and ${\beta}=91.60(3)^{\circ}$ in the space group of $P2_1/n$. The $[VO_2NTA]^{2-}$ anion has distorted octahedral geometry with cis-$VO_2$ moiety. It is confirmed that the octahedral geometry is retained in both of solution and solid-state complexes.

  • PDF

A Study of x-ray tube voltage, tube current and dose rate depeding on temperature (온도 변화에 따른 X-선진단장치의 관전압, 관전류, 조사선량에 관한 연구)

  • Chon, Ki-Hwan;Hwang, Min-Seon;Choi, Myeon-Woong;Lee, Song-Yi;Kim, Min-Ji;Yang, Dong-Il;Lee, Gwi-Yeol
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.2
    • /
    • pp.264-272
    • /
    • 2011
  • This study was function experiment or inspection of diagnosis x-ray unit at the hospital. It's how many changes tube voltage, tube current, DOSE value through the experiment depending on temperature increasing. The study want to know whether which parameter shown out of range or not how about image quality and so on. Increasing tube current and DOSE were not only too many radiation to the patient and radiation workers and make bad images but also the tube should be damaged by heat. This study was recommended proper exposure at intervals of seconds because passed inspection, reduced radiations for patient and the tube used long term. This results in the hospital`s finances will be very helpful.

Structural and Magnetic Properties of the Substituted YIG System (치환된 YIG계의 구조적 및 자기적 특성)

  • Choi, Seung-Han;Lee, Young-Bae
    • Korean Journal of Materials Research
    • /
    • v.13 no.1
    • /
    • pp.48-52
    • /
    • 2003
  • The substituted yttrium iron garnet systems $Y_{ 3-x}$/Gd$_{x}$X$0.2_{0.2}$ $Fe_{4.8}$ $O _{12}$ (x = 0.2, 0.4, 0.6) have been investigated by means of X-ray diffraction, Mossbauer spectroscopy and SQUID. The X-ray diffraction patterns at room temperature confirm the samples to have a single phase of the garnet structure over the whole composition range. The lattice constants of all the samples linearly change with increasing x due to the size of substituted ions in the dodecahedral sites. $Y_{3-x}$ $Gd_{x}$ X$Fe_{4.8}$ $In_{0.2}$ $O_{12}$ system which $Y_{3-x}$ ions are substituted with Gd$^{ 3+}$ ions, the Mossbauer spectrum consists of three Zeeman sextets at room temperature, one due to the $Fe^{3+}$ ions on the octahedral(a-) sites and the others due to the $Fe^{3+}$ ions on the tetrahedral(d-, d'-) sites, respectively. From the hysteresis loop measured by means of SQUID over the whole composition range, the saturation magnetization $M_{s}$ and magnetic moments $\mu_{ B}$ per unit cell have been obtained. The increment of Gd-ion content causes $M_{s}$ and $\mu_{B}$ decrease while the increment of In-ion content does not.

An X-ray Diffraction Study of Na, Ag-A Reduced by Hydrogen. Ag$_3\;^+$and Ag$_3\;^{2+}$ Clusters

  • Kim, Yang;Seff, Karl
    • Bulletin of the Korean Chemical Society
    • /
    • v.5 no.4
    • /
    • pp.135-140
    • /
    • 1984
  • The reduction of vacuum-dehydrated $Na_xAg_{12-x}-A, 0 {\le} x {\le} 9.2$, and its reoxidation by O$_2$, have been studied by X-ray powder diffraction. Also, the structure of $Na_6Na_6-A$ treated with hydrogen at room temperature has been studied by single crystal methods in the cubic space group Pm3m at $24{\circ}C (a = 12.221(2) {\AA})$. The diffraction pattern of dehydrated Ag$_{12}$-A reduced by H$_2$ contains only the (111) and (200) reflections of silver metal, indicationg that the zeolite structure has been lost, but the zeolite's diffraction pattern and structural integrity can be fully restored by oxidation with O$_2$ at 100 or 200${\circ}C$. In contrast, the structures of $Na_xAg_{12-x}-A$, x = 4.5 and 9.2, were not destroyed by treatment with hydrogen. Dehydrated Na$_6Ag_6$-A treated with 50 Torr of hydrogen gas at 24${\circ}C$ for 30 minutes has $6\; Na^+\;and\;1.27\;Ag^+$ ions at 6-ring sites. These $Ag^+ ions are associated with 2.54 Ag${\circ}$ atoms to form 1.27 $Ag_3^+$ clusters per unit cell. Also found were 0.7 $Ag_3^{2+}$ clusters per unit cell near the 8-rings. The structure was refined to the final error indices R$_1$ = 0.134 and R$_2$ (weighted) = 0.147, using 168 independent reflections for which $I_0 >3{\sigma}(I_0)$.

A Study on Gas Storage Medium by Using X-ray Diffraction (X-선 회절을 이용한 기체 저장제의 연구)

  • Park, Jong-Sam;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.147-155
    • /
    • 2006
  • The crystal structures of fully dehydrated $K_3Na_8H-A(R_1=0.0478,\;R_2=0.0458\;and\;a=12.257(1){\AA})$ have been studied by single-crystal x-ray diffraction methods in the cubic space group. Pm3m in order to understand the structure of the zeolite as a gas storage medium and the mechanisms based on the encapsulation and decapsulation processes of gas molecules. In the crystal structures of dehydrated $K_3Na_8H-A$, three $K^+$ ions per unit cell are located on the 8-oxygen ring(0.0, 0.4531, 0.4531) and eight $Na^+$ ions per unit cell are located near the centers of 6-oxygen rings. Each $K^+$ ions on the 8-ring is $2.87(2){\AA}$ and $2.79(1){\AA}$ away from two kinds of framework oxygen atoms. These values are more realistic than previously known values in $K_{12}Na-A$. The exact positions of $K^+$ ions are ca. $0.8{\AA}$ away from the centers of the 8-rings which are previously reported as the preferred location of $K^+$ ions. Because the zeolites frameworks are stabilized as the results, more effective controls of gas molecules at encapsulation, decapsulation, and storage are achieved. Additionally, the available storage volumes are also maximized and more volume of gases can be stored in the materials. Therefore, oxygen storage bottles in hospital can be minimized and portable oxygen bottles for patients in emergency can be developed by using the materials.

  • PDF

BLDC Motor Control Unit for Automation of X ray Equipment (X선 기기의 자동화를 위한 BLDC 모터 제어 장치)

  • Kim, Tae-Gon;Kim, Young-Pyo;Cheon, Min-Woo
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.5
    • /
    • pp.833-838
    • /
    • 2011
  • X-ray device used in the diagnosis has made possible to have more effective and accurate diagnosis, powered by the development of various devices. Based on this, X-ray device has become the most basic and essential diagnostic equipment in clinical medicine. At present, in the image acquisition field using X-ray, the use of Digital radiography which is useful in the acquisition time reduction and transfer of images and is possible to have the dose reduction has expanded. With the structure using one detector, this DR device has disadvantages in that it needs structural changes unlike existing X-ray and the detector should be moved to the desired position depending on the shooting location. Therefore, in this study, using BLDC(Brushless direct current) motor and PID(Proportional integral differential) control method, the automatic control system of 3-axis which is upward and downward, left and right and rotation of detector where having the most movement in DR was designed and produced and its performance was evaluated.

Quantification of 3D Pore Structure in Glass Bead Using Micro X-ray CT (Micro X-ray CT를 이용한 글라스 비드의 3차원 간극 구조 정량화)

  • Jung, Yeon-Jong;Yun, Tae-Sup
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.11
    • /
    • pp.83-92
    • /
    • 2011
  • The random and heterogeneous pore structure is a significant factor that dominates physical and mechanical behaviors of soils such as fluid flow and geomechanical responses driven by loading. The characterization method using non-destructive testing such as micro X-ray CT technique which has a high resolution with micrometer unit allows to observe internal structure of soils. However, the application has been limited to qualitatively observe 2D and 3D CT images and to obtain the void ratio at macro-scale although the CT images contain enormous information of materials of interests. In this study, we constructed the 3D particle and pore structures based on sequentially taken 2D images of glass beads and quantitatively defined complex pore structure with void cell and void channel. This approach was enabled by implementing image processing techniques that include coordinate transformation, binarization, Delaunay Triangulation, and Euclidean Distance Transform. It was confirmed that the suggested algorithm allows to quantitatively evaluate the distribution of void cells and their connectivity of heterogeneous pore structures for glass beads.

Calculation of Photoelectric Yield by X-ray (X선(線)에 의한 광전수율(光電收率) 계산(計算)에 관(關)한 연구(硏究))

  • Song, Jae-Kwan
    • Journal of radiological science and technology
    • /
    • v.1 no.1
    • /
    • pp.31-35
    • /
    • 1978
  • X-rays contribute to electron emission from material surfaces primarily through photoelectric interaction. A simple model is described for predicting the yield and energy spectrum of photon and Auger electrons emitted from materials exposed to X-ray with low energy. In this paper, We have calculated the yield of primary, Auger, and secondary, electrons. The results of the photoelectric yield model developed here suggests that. I) The angular distribution of emitted electrons(Per unit angle) is proportional to $sin{\theta}\;cos{\theta}$ for all electron energies and all components(Primary, Auger, or Secondary) II) The shape of the energy spectrum of the photoelectric yield is independent of angle. III) For this targets the forward and backward photoelectric yields are indentical.

  • PDF