• Title/Summary/Keyword: X-ray Unit

Search Result 563, Processing Time 0.024 seconds

Crystal Structure Analysis of 6-Ethoxy-3-phenyl-5a,9a-dihydro-3H-chromen[4,3-c][1,2]oxazole-3a(4H)-carbonitrile

  • Malathy, P.;Sharmila, P.;Srinivasan, J.;Manickam, Bakthadoss;Aravindhan, S.
    • Journal of Integrative Natural Science
    • /
    • v.9 no.2
    • /
    • pp.94-102
    • /
    • 2016
  • The crystal structure of the potential active 6-ethoxy-3-phenyl-5a,9a-dihydro-3H-chromen[4,3-c][1,2]oxazole-3a(4H)-carbonitrile ($C_{19}H_{15}N_2O_3$) has been determined from single crystal X-ray diffraction technique. The title compound crystallizes in the monoclinic space group C2/c with unit cell dimension a= 29.3026(9) ${\AA}$, b= 6.7695(2) ${\AA}$ and c= 19.7597(6) ${\AA}$ [${\alpha}= 90^{\circ}$, ${\beta}= 125.709(10)^{\circ}$ and ${\gamma}= 90^{\circ}$]. Single crystals suitable for X-ray diffraction were obtained by slow evaporation method, the isoxazole and six membered pyran rings adopts envelope conformation. The crystal packing of the molecules is stabilized by the weak $C-H{\ldots}N$ hydrogen bond interaction.

Crystal Structure Analysis of Methyl 8-bromo-3-phenyl-5a,9a-dihydro-3H-chromen [4,3-c][1,2] isoxazole-3a(4H)-carboxylate

  • Malathy, P.;Sharmila, P.;Srinivasan, J.;Manickam, Bakthadoss;Aravindhan, S.
    • Journal of Integrative Natural Science
    • /
    • v.9 no.2
    • /
    • pp.103-112
    • /
    • 2016
  • The crystal structure of the potential active Methyl 8-bromo-3-phenyl-5a,9a-dihydro-3H-chromen [4,3-c][1,2] isoxazole-3a(4H)-carboxylate ($C_{18}H_{15}BrNO_4$) has been determined from single crystal X-ray diffraction technique. The title compound crystallizes in the triclinic space group Pī with unit cell dimension a=8.3129 (3) ${\AA}$, b=9.5847 (4) ${\AA}$ and c=11.1463(4) ${\AA}$ [${\alpha}=98.457(3)^{\circ}$, ${\beta}=102.806(2)^{\circ}$ and ${\gamma}=105.033(5)^{\circ}$]. Single crystals suitable for X-ray diffraction were obtained by slow evaporation method, the isoxazole and six membered pyran rings adopts envelope conformation. In the crystal, molecules are linked via pairs of inter molecular $C-H{\ldots}O$ hydrogen bonds to form dimmers.

Synthesis and Structural Analysis of 2-Amino-4-(4-hydroxy-3-methoxyphenyl)-7,9-dimethyl-5-oxo-4, 5, 6, 7-tetrahydropyrano [2, 3-d] pyrazolo [3, 4-b] pyridine-3-carbonitrile through X-ray Crystallography

  • Ganapathy, Jagadeesan;Jayarajan, R.;Vasuki, G.;Sanmargam, Aravindhan
    • Journal of Integrative Natural Science
    • /
    • v.8 no.1
    • /
    • pp.30-39
    • /
    • 2015
  • The crystal structure of the potential active 2-amino-4-(4-hydroxy-3-methoxyphenyl)-7, 9-dimethyl-5-oxo-4, 5, 6, 7-tetrahydropyrano [2, 3-d] pyrazolo [3, 4-b] pyridine-3-carbonitrile ($C_{21}H_{22}N_5O_6S$) has been determined from single crystal X-ray diffraction data. In the title compound crystallizes in the monoclinic space group P-1 with unit cell dimension a=8.1201(9)${\AA}$, b=12.2684(4)${\AA}$ and c=12.387(2)${\AA}$ [${\alpha}=69.573^{\circ}$, ${\beta}=12.168^{\circ}$ and ${\gamma}=76.060^{\circ}$]. In the structure the pyrazole, pyridine and pyran are almost coplanar each other. The crystal packing is stabilized by intermolecular C-H...O and N-H... O hydrogen bond interaction.

The Retrospective Study of Essential X-ray in Emergency Multiple Trauma Patients (응급 다발성 외상환자의 기본적 방사선 촬영부위에 관한 조사연구)

  • Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.19 no.2
    • /
    • pp.51-57
    • /
    • 1996
  • Radiography should be used judiciously and should not delay patients resuscitation. In the patient with emergency multiple trauma, three radiography should be obtained-cervical spine, anteroposterior(AP) chest, and AP pelvis. These examinations can be done in the resuscitation area, usually with a portable X-ray unit, but should not interrupt the resuscitation process. A retrospective study was carried on 157 emergency multiple trauma patients who were admitted to Yong Dong Severance Hospital from January, to December in 1995. I analyzed the types of X-ray examinations in emergency multiple trauma patients, and classified the patients by disoriented group of mentality. The results were as follows: 1. The subjects were 7.1%(157patients) of 2,208 trauma patients(7.3%) in total 30,085 emergency patients. 2. Male to female ratio was 2.57 : 1. The age distribution was highest from 31 years to 40 years(28.0% ). 3. The peak time of patient's entrance in emergency center was between 8 : 00 pm and 2 : 00 am(36.9%), and second peak time was between 2 : 00 pm and 8 : 00 pm (29.3%). 4. According to the injury type, traffic accident, motorcycle accident and falling down were 71.3%, 8.3% and 20.4% respectively. 5. According to the exposure rate of Computed Tomography, chest CT, cervical CT pelvis CT and brain CT were 39.5%, 24.2%, 69.4% and 51.6% respectively.

  • PDF

X-ray Diffraction Studies of Poly(aryl ether ether ketone) Fibers with Different Degrees of Crystallinity and Orientation

  • Karacan Ismail
    • Fibers and Polymers
    • /
    • v.6 no.3
    • /
    • pp.206-218
    • /
    • 2005
  • Structural studies of series of 'as spun' and drawn PEEK fibers have been carried out using X-ray diffraction and optical microscopy techniques. The analysis of results suggest that fibers produced at a constant draw ratio with increasing draw temperatures show enhanced orientation and crystalline behaviour. The resolved equatorial and meridional traces provide additional structural parameters in terms of crystallinity, crystallite size, and crystallite thickness. It is concluded that drawing at a temperature below $T_g(i.e.,\;144^{\circ}C)$ results in poorly oriented non-crystalline materials, whereas drawing above $T_g$ results in highly oriented semi crystalline materials. Additional drawing proved to increase the overall orientation with slight improvements in lateral order of the chain molecules. Quantitative analysis revealed that the crystallite size increases with increasing drawing temperature. The results also revealed the increased crystallite size upon additional drawing. Crystalline orientation parameter, $_c$, suggests almost perfect orientation. In all cases, the amorphous orientation is found to be lower than the overall orientation parameter obtained from the optical birefringence. As a result of additional drawing, crystalline orientation was found to increase slightly but the increase in the orientation of non-crystalline material was found to be substantial. An average crystalline density was determined from the orthorhombic unit cell dimensions. It was found to vary as a result of processing conditions. It was also found that the value of the maximum birefringence shows heavy dependence on the chain conformation.

Crystallization and Preliminary X-Ray Crystallographic Analysis of PAS Factor from Vibrio vulnificus

  • Lee, Jun Hyuck;Kim, Soo Young;Rho, Seong-Hwan;Im, Young Jun;Kim, Young Ran;Kim, Mun-Kyoung;Kang, Gil Bu;Rhee, Joon Haeng;Eom, Soo Hyun
    • Molecules and Cells
    • /
    • v.20 no.3
    • /
    • pp.361-363
    • /
    • 2005
  • Plasmid Achromobacter secretion (PAS) factor is a putative secretion factor that induces the secretion of periplasmic proteins. PAS factor from Vibrio vulnificus was crystallized at 294 K by the hanging drop vapor-diffusion method. It was isolated as a monomer during the purification procedures. The native crystal belongs to the F222 space group with unit cell parameters a = 56.1, b = 74.4, $c=80.0{\AA}$, ${\alpha}={\beta}={\gamma}=90^{\circ}$. The crystal was soaked in cryoprotectant containing 1 M NaBr for 1 h for MAD phasing. The diffraction limit of the Br-MAD data set was $1.9{\AA}$ using synchrotron X-ray irradiation at beam line BL-18B at the Photon Factory, Japan.

A Method for Region-Specific Anomaly Detection on Patch-wise Segmented PA Chest Radiograph (PA 흉부 X-선 영상 패치 분할에 의한 지역 특수성 이상 탐지 방법)

  • Hyun-bin Kim;Jun-Chul Chun
    • Journal of Internet Computing and Services
    • /
    • v.24 no.1
    • /
    • pp.49-59
    • /
    • 2023
  • Recently, attention to the pandemic situation represented by COVID-19 emerged problems caused by unexpected shortage of medical personnel. In this paper, we present a method for diagnosing the presence or absence of lesional sign on PA chest X-ray images as computer vision solution to support diagnosis tasks. Method for visual anomaly detection based on feature modeling can be also applied to X-ray images. With extracting feature vectors from PA chest X-ray images and divide to patch unit, region-specific abnormality can be detected. As preliminary experiment, we created simulation data set containing multiple objects and present results of the comparative experiments in this paper. We present method to improve both efficiency and performance of the process through hard masking of patch features to aligned images. By summing up regional specificity and global anomaly detection results, it shows improved performance by 0.069 AUROC compared to previous studies. By aggregating region-specific and global anomaly detection results, it shows improved performance by 0.069 AUROC compared to our last study.

Synthesis of Silicon Carbide Nanowhiskers from Coconut Fibres and Sol-Gel Derived Silica

  • Raman, V.;Bhatia, G.;Mishra, A.;Saha, M.;Sengupta, P.R.;Srivastava, A.K.
    • Carbon letters
    • /
    • v.7 no.3
    • /
    • pp.166-170
    • /
    • 2006
  • Silicon carbide whiskers ($SiC_w$) having the diameter in the range of 20-80 nm were synthesised from coconut fibres through sol-gel process. The coconut fibres were impregnated with tetraethoxysilane and methyltriethoxysilane derived sol and pyrolyzed at $1400^{\circ}C$ in argon. X-ray of the pyrolyzed samples showed the formation of ${\beta}$-SiC.

  • PDF

An ability test for the use of indirect radiographic unit (간접촬영용 X-선 발생장치 성능 평가)

  • Im, In-Cheol
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.37-41
    • /
    • 2004
  • Purpose : Raise ability cultivation in presence at a sicked business by performance management estimation of device through measurement. Also Learn a technology that measure exact tube voltage, exposure time, output dose. And it is to grasp photofluorography X-ray generator existing circumstances using at hospital. Material & Method : Investigated Photofluorography X-ray generator(inside, outside each 10) of 10 university hospitals using tube voltage, exposure time, output dose measuring instrument. Result : Photofluorography device that tube voltage correctness is incongruent by examination PAE decision came out 3, and at exposure time correctness examination 2 incongruent, Also 3 that calculate coefficient of variation about exposure in repeatability examination of exposure were incongruent. Inappropriate photofluorography device is 5 outside hospital(mobile unit) and the thing in hospital was 3 in 3 kind of efficiency test. It appeared high that photofluorography device outside hospital is more incongruent than thing in hospital. Conclusion : May ready situation that can offer patient medical service of good quality by radiation exposure reduction, image quality administration, retake decrease etc. by keeping performance of Photofluorography device. Therefore, is considered that need on-time efficiency test.

  • PDF

Physical Properties of Poly(ethylene terephthalate)-Poly(1, 4-phenylene terephthalate) Copolyester (Poly (ethylene terephthalate)-Poly (1, 4-phenylene terephthalate) Copolyester의 물성)

  • Ahn, Tae Oan;Nam, Byeong Uk;Park, Jong-Yoon
    • Applied Chemistry for Engineering
    • /
    • v.2 no.3
    • /
    • pp.246-252
    • /
    • 1991
  • Copolyesters (PEHT) of poly (ethylene terephthalate) (PET) and poly (1,4-phenylene terephthalate) (PHT) were synthesized by the solution polymerization with the PHT unit contents of less than 30 mol %, and their physical properties were studied. As the content of PHT unit in PEHT was increased, glass transition temperature, crystallization rate, thermal stability increased, whereas melting temperature decreased. When the PHT unit contents were 16.5 and 24.9 mol%, nematic mesophase was observed. Wide angle X-ray diffraction pattern showed the peaks originated from both PET unit and PHT unit.

  • PDF