• Title/Summary/Keyword: X-ray Screening

Search Result 121, Processing Time 0.027 seconds

On the Research of 17th Century Joseon Dynasty's Bulsang, a Buddist Statue, Manufacturing Technique by Examining the Daeungbojeon Hall Samse-bulsang, The Buddha of the Three Words, at the Haenam Daeheungsa Temple (해남 대흥사 대웅보전 삼세불상을 통해 본 17세기 조선시대 불상의 제작기법 연구)

  • Lee, Su-yea
    • Korean Journal of Heritage: History & Science
    • /
    • v.47 no.1
    • /
    • pp.164-179
    • /
    • 2014
  • The Buddhas of the Three Words in a form of arranging Bhaiṣajyaguru and $Amit{\bar{a}}bha$ at its side based on ${\acute{S}}{\bar{a}}kyamuni$ at the center is enshrined in Daeungbojeon Hall of Daeheungsa Temple located at Haenam. So far, this Buddhas of the Three Words has been known as a wooden Buddha statue. However, as a result of X-ray screening, in left/right Buddha statues excepting main Buddha, wood and molding clay layer were observed at the same time. Therefore, this study intended to observe its internal structure, grafting method and to clarify making technique of Buddha statue during Joseon era based on image information being obtained through X-ray screening of The Buddhas of the Three Words of Daeheungsa Temple. As its result, it was revealed that form of ${\acute{S}}{\bar{a}}kyamuni$ was completed by mainly grafting 5 pieces of timber and this statue shows a typical wood grafted Buddha statue during Joseon era. Form of Bhaiṣajyaguru and $Amit{\bar{a}}bha$ were completed based on molding technique by applying clay on sculpture similar to its appearance after sculpturing more than 10 pieces of timber through its grafting. In other words, internal timber is considered to play a role of its core and grafting method of timber is more close to a technique of molding Buddha statue than to that of wooden Buddha statue during Joseon era. However, clay was directly applied on timber thinly, not applying clay thickly on it after winding straw rope on wooden core and its characteristic is that its facial area was completely composed of wooden construction only. Therefore, it is hard to rule out a possibility that the original sculpturing intention of an artist might be a wooden Buddha statue but in view of the fact that a word, 'molding' was used in a record of relics buried in statue, it could be seen that this Buddha statue might have been recognized as a molding statue at the time when creation of this statue was completed. It is considered that number of case of making statue based on this technique would be more increased when more results of X-ray screening should be accumulated and if more data should be collected, it would provide a significant evidence for identifying chronological, regional aspects of making technique of Buddha statue.

Comparative Analysis of pre and Post Digital X-ray Equipment Construction and Web-Based Wireless Network Environment Construction for Medical Screening Vehicles (Digital X-ray장비 구축 검진차량의 웹 기반 무선 네트워크 환경 구축 전과 후의 비교분석)

  • Ryu, Young-Hwan;Kweon, Dae-Cheol;Goo, Eun-Hoe;Dong, Kyung-Rae;Choi, Sung-Hyun;Jang, Young-Ill
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.103-111
    • /
    • 2010
  • A total of 200 hospital employees participated in this study from January 2009 to June 2010. For the survey, each participant was given necessary items for external health exams. Cronbach's alpha was calculated for the survey regarding wireless networks. There was a need for educating data processing workers in the medical field regarding fundamental information prior to wireless network construction. The reason is high scores would be collected, which would reflect knowledge regarding data processing used at hospitals and the differences between paper charts and electronic charts. However, low scores were obtained which reflected knowledge regarding the differences between wired and wireless networks and Mini-PACS. Time for each patient was shortened to a maximum of three minutes and minimum of one minute for treatment and transmitting medical images when comparing pre and post wireless network construction(p < 0.01). Scores from the pre and post construction survey increase 1.98, 1.65, and 1.43 points for activity in the health screening area, usage of space in the health screening vehicle, and patient information storage respectively(p < 0.05). The number of patients receiving external health screenings twelve times was 3,655 prior to construction of a wireless network system. However, the number increased to 4,265 after construction. The increasing percentage was 17% in total. Prior to construction, X-ray images were taken 527 times, but after construction of a wireless network, this number growed to 1,194 and it was 116% increase. The loss of patient's medical treatment charts was reduced from 19.8% to 18.7% after construction. We believe that educating medical workers on Mini-PACS and Mini-OCS Systems will not only increase their efficiency but also make patients receiving better treatment.

  • PDF

Material Discrimination Using X-Ray and Neutron

  • Jaehyun Lee;Jinhyung Park;Jae Yeon Park;Moonsik Chae;Jungho Mun;Jong Hyun Jung
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.4
    • /
    • pp.167-174
    • /
    • 2023
  • Background: A nondestructive test is commonly used to inspect the surface defects and internal structure of an object without any physical damage. X-rays generated from an electron accelerator or a tube are one of the methods used for nondestructive testing. The high penetration of X-rays through materials with low atomic numbers makes it difficult to discriminate between these materials using X-ray imaging. The interaction characteristics of neutrons with materials can supplement the limitations of X-ray imaging in material discrimination. Materials and Methods: The radiation image acquisition process for air-cargo security inspection equipment using X-rays and neutrons was simulated using a GEometry ANd Tracking (Geant4) simulation toolkit. Radiation images of phantoms composed of 13 materials were obtained, and the R-value, representing the attenuation ratio of neutrons and gamma rays in a material, was calculated from these images. Results and Discussion: The R-values were calculated from the simulated X-ray and neutron images for each phantom and compared with those obtained in the experiments. The R-values obtained from the experiments were higher than those obtained from the simulations. The difference can be due to the following two causes. The first reason is that there are various facilities or equipment in the experimental environment that scatter neutrons, unlike the simulation. The other is the difference in the neutron signal processing. In the simulation, the neutron signal is the sum of the number of neutrons entering the detector. However, in the experiment, the neutron signal was obtained by superimposing the intensities of the neutron signals. Neutron detectors also detect gamma rays, and the neutron signal cannot be clearly distinguished in the process of separating the two types of radiation. Despite these differences, the two results showed similar trends and the viability of using simulation-based radiation images, particularly in the field of security screening. With further research, the simulation-based radiation images can replace ones from experiments and be used in the related fields. Conclusion: The Korea Atomic Energy Research Institute has developed air-cargo security inspection equipment using neutrons and X-rays. Using this equipment, radiation images and R-values for various materials were obtained. The equipment was reconstructed, and the R-values were obtained for 13 materials using the Geant4 simulation toolkit. The R-values calculated by experiment and simulation show similar trends. Therefore, we confirmed the feasibility of using the simulation-based radiation image.

Identification of new ligands for RNA pseudoknot by structure-based screening of chemical database

  • Park, So-Jung;Jeong, Seung-Hyun;Kim, Yang-Gyun;Park, Hyun-Ju
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.254.2-254.2
    • /
    • 2003
  • For many viruses, -1 ribosomal frameshifting regulate protein synthesis using an RNA pseudoknot. The integrity of pseudoknot stability and structure is the important feature for efficient frameshifting. Thus, small molecules interacting with viral RNA pseudoknots would be potential antiviral agents targeting\ulcorner frameshifting system in viruses. X-ray structure of RNA pseudoknot complexed with biotin has been reported, in which biotin is bound at the interface between the pseudoknot's stacked helices. (omitted)

  • PDF

Changes in Gait Parameter with Adolescent Idiopatic Scoliosis

  • Kim, Su-Hyon;Kim, Hyun-Jin
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.3
    • /
    • pp.136-139
    • /
    • 2014
  • Purpose: The purpose of this study will demonstrate that relationship between scoliosis and gait factor and foot weight bearing in ambulation. Methods: Subjects were 40 elementary students. A normal control group consisted of a total of 20 children without any known musculoskeletal disorders and an AIS group of 20 children with mild AIS (defined by a Cobb angle between 10 and $25^{\circ}$) were recruited. Measurements were scoliometer screening test, Cobb angle, gait parameter (rate of swing/stance phase, gait velosity), foot weight bearing (entire, fore, hind). Results: Scoliometer screening test (P = 0.000) and X-ray Cobb angle (P = 0.000) significant difference of group which was significantly higher in the AIS group. Gait parameter not showed significant difference. Forefoot weight bearing was significantly higher in the AIS group than more normal group. Conclusion: It seems that the results of weight bearing analysis in ambulation may be used in modifying rehabilitation programs for individual needs of patients with idiopathic scoliosis.

Ligand-Based Virtual Screening for inhibitors of PTP-1B with Antihyperglycemic properties

  • Kim, Heung-Jae;Yoo, Moo-Hi;Son, Mi-Won;Kim, Soon-Hoe
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.359.3-359.3
    • /
    • 2002
  • Protein-tyrosine phosphatase 1 B(PTP-l B). which plays a key role in insulin signaling. is rising as a fascinating target for type 2 diabetes and obesity. Many scientists in structural biology solved the three dimensional X-ray Crystal structure of this type of enzyme, so we could easily get the active site structure of PTP-1 B or complex structure with ligand. Our virtual screening study for PTP-1B exactly based on these crystal strucutures from public database. (omitted)

  • PDF

Cross-sectional Survey for Prevalence Rate of Scoliosis in Primary, Middle and High School Boys in Pusan City (부산시내 남자 초.중.고등학생의 척추측만증 유병률 측정을 위한 단면조사)

  • Kim, Bok-Yong;Park, Jung-Han;Kim, Poong-Taek
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.2 s.24
    • /
    • pp.217-223
    • /
    • 1988
  • A cross-sectional survey was conducted to determine the prevalence rate of scoliosis in elementary, middle and high school boys in May 1988. The study population included 1,393 male students in Pusan ; 463 students of 4th grade in two elementary schools, 543 students of 1st grade in one middle school and 387 students of 1st grade in one high school. The students of elementary school were screened with inspection by two physicians at the same time and the students of middle and high schools were screened with both inspection by the same physicians and 70mm chest X-ray. Positive students in any one of the two screening tests were measured for height and body weight and asked for the shoulder side on which he carries the school bag. The angle of curvature on X-ray film was measured by Cobb's method. The number of positive students in any one of the two screening tests were 15(3.2%) in elementary schools, 174(32.0%) in middle school and 92(23.8%) in high school. However, positive rates in both tests were only 2.2% for the middle school students and 2.6% for the high school students and among these students 1.1% out of total middle school students and 2.3% of high school students had a curvature equal to or greater than $5^{\circ}$ of Cobb's angle on 70mm chest X-ray film. There was a statistically significant association between the direction of spinal curve and the shoulder side on which one carries school bag among positive students in both screening 1.sts (p<0.05) Mean height and body weight of 281 positive students in any one of two screening tests were compared with the Korean standard for the same age. Mean weight of elementary school students was nearly the same as the standard weight but the height was slightly shorter than the standard. However, both mean height and weight of the middle school students were lower than the standard while those of the high school students were higher. The prevalence rate of scoliosis for the 2nd and 3rd grades of high school is presumed to be higher than that of the 1st grade of high school and the rate for girls will be even higher than the rate for boys of the same age. Thus, scoliosis seems to be an important school health problem. To prevent scoliosis, it is recommeded to reduce the weight of school bag, educate the students to keep a right posture and exercise periodically.

  • PDF

Investigation of Near Infrared Radiation Based Screening for Video-Fluoroscopy Swallowing Studies (비디오투시연하검사 스크리닝을 위한 근적외선 기술 조사)

  • Park, Ji-Su;Jung, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.9-14
    • /
    • 2021
  • With the recent advances in radiological science, there was radiographic techniques development and several researches to diagnosing dysphagia. We proposed the new Imaging technology based on Near Infrared radiation (NIR) for video fluoroscopic swallowing study (VFSS). To reduce the risk of the VFSS examination for swallowing rehabilitation, multi-NIR camera system comprised. Based on the multi-NIR camera imaging system, Computational simulation was conducted to identify the potential of the multi-NIR camera imaging system as a clinical tool (screening system). As a result of the simulation applied in this study, the proposed system has a potential to be a clinical solution although there is a few of limitations. we believe that it will be a good tool to support the VFSS as a screening technology in clinical fields.

A Study on the Actual Conditions of Scoliosis in Fifth and Sixth Grade School Children (초등학교 5, 6학년을 대상으로 한 척추측만증 실태조사)

  • Lee, Sook-Bee;Kim, Jong-Bee
    • Journal of the Korean Society of School Health
    • /
    • v.12 no.1
    • /
    • pp.143-148
    • /
    • 1999
  • The focus of this study is to introduce the relationship between the Forward Bending Test and scoliosis. Our research screening process was conducted on elementary fifth and sixth grade school children. X-ray analysis on students who tested positive on the Forward Bending Test showed a strong positive relationship between the two. Thus, it is desirable that local schools participate actively in taking the Forward Bending Test for early detection of scoliosis among school children. In addition, schools should educate their students technigues that prevent scoliosis and the progress of it by teaching technigues how to sit up as well as muscle enhancing exercises around the spine and pelvic area.

  • PDF