• Title/Summary/Keyword: X-ray Optics

Search Result 126, Processing Time 0.022 seconds

The Development of Beamline Hutch Structures at PAL-XFEL (PAL-XFEL 빔라인 허치 구조물 개발)

  • Kim, Seungnam;Kim, Myeongjin;Kim, Seonghan;Kim, Yeongchan;Shin, Hocheol;Kim, Jihwa;Kim, Kyeongsuk;Kim, Kwangwoo;Eom, Intae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.5
    • /
    • pp.567-577
    • /
    • 2016
  • The hutches which are installed in the beamline are largely classified into two, i.e XPP (X-ray pump probe) and CXI (Coherent X-ray image). Laser room is installed on the hutch and provides laser to XPP and CXI simultaneously. And two hutches have heavy crane to install some optics equipments. Safety and reliability of hutch structures should be taken into account for the precise operating of the laser facilities, so vibration analysis is essential to do this. The main purpose of vibration analysis is to install hutch structures with large stiffness. We have changed materials specification several times to install hutch structures having strong stiffness. Now hutch structures were installed and checked vibration status at laser room and XPP hutch. The results of laser table and robot arm satisfy vibration criteria. This paper explains about the design and vibration analysis of hutch structures.

Material Properties of GeSbSe Chalcogenide Glass and Fabrication Process for 8~12 ㎛ IR Region Aspherical Optical Lens (GeSbSe계 기반 8~12 ㎛ 파장대역 적외선 광학 렌즈 제작 및 비구면 렌즈 가공기술 개발)

  • Bae, Dong-Sik;Yeo, Jong-Bin;Han, Sang-Hyun;Lee, Hyun-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.3
    • /
    • pp.183-189
    • /
    • 2013
  • The chalcogenide glass has superior optical properties in IR region transmittances. We have determined the composition of GeSbSe chalcogenide glass for the application of good IR lenses, resulting in the composite rate of $Ge_{19}Sb_{23}Se_{58}$. The optical, structural, thermal and physical properties were measured by Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), Differential scanning calorimeter (DSC), X-ray computed tomography (X-ray CT) respectively. The fabrication of the chalcogenide glass lens for infrared optics applications was proposed using a diamond turning machining technology which is known as the suitable ways for the production cost reduction and the accurate fabrication process control.

Preparation of electrostatic spray pyrolysis derived nano powder and hydroxyapatite forming ability (정전분무 열분해법에 의한 나노분말의 제조 및 하이드록시 아파타이트 형성능력 평가)

  • Lee, Young-Hwan;Jeon, Kyung-Ok;Jeon, Young-Sun;Lee, Ji-Chang;Hwang, Kyu-Seog
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.16 no.6
    • /
    • pp.244-249
    • /
    • 2006
  • Electrostatic spray pyrolysis, a novel fabrication technique, has been used in this study to prepare calcium phosphate nano powders. Final annealing was done at $400^{\circ}C$ for 30min in air. The hydroxyapatite - forming ability of the annealed powder has been evaluated in Eagle's minimum essential medium solution (MEM). X-ray diffraction analysis, field emission - scanning electron microscope, energy dispersive X-ray spectroscope, and Fourier transform infrared spectroscope were used to characterized the annealed powders after immersion in MEM. The powder with an amorphous structure induced hydroxyapatite formation on their surfaces after immersion fer 15 days.

Composition and Surface Analyses of RGP Contact Lenses (RGP 콘택트렌즈의 성분과 표면 분석)

  • Jang, Jun-Kyu;Shin, Hyung-Sup
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.329-337
    • /
    • 2010
  • Purpose: The surfaces and compositions of rigid gas permeable (RGP) contact lenses were analyzed with the consistent methods, and the basic informations for the composition design of lens materials were suggested. Methods: The bulk structures were analyzed by using Fourier infrared spectroscopy (FTIR), the compositions of surface components were observed by using x-ray photoelectron spectroscopy (XPS), the surface morphology and roughness were observed using atomic force microscopy (AFM), and the wettabilities were estimated by the surface wetting angles. The relations and trends of those results were analyzed. Results: The high oxygen permeability RGP lenses showed the trend that the fluorine decreases and the silicon increases. As the silicon and fluorine contents increased, the carbon and oxygen contents of RGP lens materials decreased at a constant ratio. The decreasing ratio of the carbon contents was three times larger than the decreasing ratio of oxygen contents. The composition of the surface treated lens was far from these tendency line. When the silicon contents increased, the rough surface was formed with the cohered particles. When the fluorine contents increased, the rough surface was formed with the deep flaws. The surface roughness increased and then wettabilities decreased as the silicon and fluorine contents increased. For the surface roughness changes, the increasing ratio of the silicon contents was two times larger than the increasing ratio of fluorine contents. The surface of RGP lens materials appeared the hydrophobic character of which the wettabilities decreased when the roughnesses increased. Conclusions: The surfaces and compositions of RGP contact lenses were measured by the same methods. Those results and relationships were compared and analysed. It is considered that these research results will be applied with the basic data for the composition design of lens materials.

System Resolution Recovery by Motion Blur Recovery Technique - Particuar Application to X-ray Computerized Tomography (이동 Blur 회복법을 이용한 분해능 향상-X-ray C.T.에의 응용)

  • 이수영;김홍석
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.3
    • /
    • pp.26-35
    • /
    • 1980
  • The degradation of image due to the finite size of sensing devices has been one of the problems in all digital imaging systems. The basic study on the improvement of the spatial resolution was carried out in both spatial and frequency domains by the resolution recovery techniques which have been used in optics. Here, the techniques were applied to CT (Computerized Tomography) system, and image with finer resolution was obtained by these techniques. The basic theory is described and the results of the simulation are shown.

  • PDF

Advanced Flow Visualization Techniques for Diagnosing Microscale Biofluid Flows (미세 생체유동 해석을 위한 첨단 유동가시화기법)

  • Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • Recently microscale biofluid flows have been receiving large attention in various research areas. However, most conventional imaging techniques are unsatisfactory due to difficulties encountered in the visualization of microscale biological flows. Recent advances in optics and digital image processing techniques have made it possible to develop several advanced micro-PIV/PTV techniques. They can be used to get quantitative velocity field information of various biofluid flows from visualized images of tracer particles. In this paper, as new advanced micro-PIV techniques suitable for biofluid flow analysis, the basic principle and typical applications of the time-resolved micro-PIV and X-ray micro-PIV methods are explained. As a 3D velocity field measurement technique for measuring microscale flows, holographic micro-PTV method is introduced. These advanced PIV/PTV techniques can be used to reveal the basic physics of various microscale biological flows and will play an important role in visualizing veiled biofluid flow phenomena, for which conventional methods have many difficulties to analyze.

In Situ X-ray Photoemission Spectroscopy Study of Atomic Layer Deposition of $TiO_2$ on Silicon Substrate

  • Lee, Seung-Youb;Jeon, Cheol-ho;Kim, Yoo-Seok;Kim, Seok-Hwan;An, Ki-Seok;Park, Chong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.222-222
    • /
    • 2011
  • Titanium dioxide (TiO2) has a number of applications in optics and electronics due to its superior properties, such as physical and chemical stability, high refractive index, good transmission in vis and NIR regions, and high dielectric constant. Atomic layer deposition (ALD), also called atomic layer epitaxy, can be regarded as a special modification of the chemical vapor deposition method. ALD is a pulsed method in which the reactant vapors are alternately supplied onto the substrate. During each pulse, the precursors chemisorb or react with the surface groups. When the process conditions are suitably chosen, the film growth proceeds by alternate saturative surface reactions and is thus self-limiting. This makes it possible to cover even complex shaped objects with a uniform film. It is also possible to control the film thickness accurately simply by controlling the number of pulsing cycles repeated. We have investigated the ALD of TiO2 at 100$^{\circ}C$ using precursors titanium tetra-isopropoxide (TTIP) and H2O on -O, -OH terminated Si surface by in situ X-ray photoemission spectroscopy. ALD reactions with TTIP were performed on the H2O-dosed Si substrate at 100$^{\circ}C$, where one cycle was completed. The number of ALD cycles was increased by repeated deposition of H2O and TTIP at 100$^{\circ}C$. After precursor exposure, the samples were transferred under vacuum from the reaction chamber to the UHV chamber at room temperature for in situ XPS analysis. The XPS instrument included a hemispherical analyzer (ALPHA 110) and a monochromatic X-ray source generated by exciting Al K${\alpha}$ radiation (h${\nu}$=1486.6 eV).

  • PDF

High Purification of Hg2Br2 Powder for Acousto-Optic Tunable Filters Utilizing a PVT Process (PVT공정을 이용한 음향광학 가변 필터용 Hg2Br2 파우더의 고순도 정제)

  • Kim, Tae Hyeon;Lee, Hee Tae;Kwon, In Hoi;Kang, Young-Min;Woo, Shi-Gwan;Jang, Gun-Eik;Cho, Byungjin
    • Korean Journal of Materials Research
    • /
    • v.28 no.12
    • /
    • pp.732-737
    • /
    • 2018
  • We develop a purification process of $Hg_2Br_2$ raw powders using a physical vapor transport(PVT) process, which is essential for the fabrication of a high performance acousto-optic tunable filter(AOTF) module. Specifically, we characterize and compare three $Hg_2Br_2$ powders: $Hg_2Br_2$ raw powder, $Hg_2Br_2$ powder purified under pumping conditions, and $Hg_2Br_2$ powder purified under vacuum sealing. Before and after purification, we characterize the powder samples through X-ray diffraction and X-ray photoelectron spectroscopy. The corresponding results indicate that physical properties of the $Hg_2Br_2$ compound are not damaged even after the purification process. The impurities and concentration in the purified $Hg_2Br_2$ powder are evaluated by inductively coupled plasma-mass spectroscopy. Notably, compared to the sample purified under pumping conditions, the purification process under vacuum sealing results in a higher purity $Hg_2Br_2$ (99.999 %). In addition, when the second vacuum sealing purification process is performed, the remaining impurities are almost removed, giving rise to $Hg_2Br_2$ with ultra-high purity. This high purification process might be possible due to independent control of impurities and $Hg_2Br_2$ materials under the optimized vacuum sealing. Preparation of such a highly purified $Hg_2Br_2$ materials will pave a promising way toward a high-quality $Hg_2Br_2$ single crystal and then high performance AOTF modules.

Fabrication of Silicon Angle Standard and Calibration of Rotary Encoder Using Silicon Angle Standard (각도교정용 실리콘 다면체의 제작과 이를 이용한 회전에코더의 각도교정)

  • 박진원;엄천일
    • Korean Journal of Crystallography
    • /
    • v.6 no.2
    • /
    • pp.88-92
    • /
    • 1995
  • Higly pure silicon crystals with an almost perfect lattice structure constityte a powerful metrological tool. The streographic standard prohection for the (111) orientation of diamond structure found by the Laue method shows angles between net planes of 60°. This value is known to be certain to some 10-8 rad. We have made a six-faced silicon polygon, and the (220) lattice planes of the polygon act as a reference angular standard. The information of angles between lattice planes could be taken by the X-ray diffraction. The angle of the rotary encoder have been calibrated using the silicon angle standard. The X-ray optics was double crystal arrangement.

  • PDF