• 제목/요약/키워드: X-ray Imaging Technique

검색결과 153건 처리시간 0.024초

X선 3차원 영상 시스템에서의 영상 왜곡 및 영상 좌표계 보정 (Correction of Image Distortion and Coordinate Calibration of the x-ray three dimensional imaging system)

  • 노영준;김재완;조형석;전형조;김형철;주효남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.413-413
    • /
    • 2000
  • In this paper, we propose a series of calibrations f3r the x-ray three dimensional imaging system. In the developed x-ray system, a three dimensional inner and outer shape of an object can be reconstructed out of two dimensional transmitted x-ray image set, which are acquired by projecting x-ray to the object from different views. To achieve this, a reconstruction algorithm which estimates and updates the three dimensional volume from x-ray images is developed. The algorithm is named as uniform and simultaneous algebraic reconstruction technique(USART) which is an iterative method estimating a 3D volume based on its projected images. In this method, it is assumed that the imaging conditions that are the relative positions between the x-ray sources, object and the image planes are blown. Practically it is not easy to know the three dimensional coordinate of the components of the system, since the x-ray is not visible and the image distortions are present due to the optical components in the system. In this paper, methods of correcting image distortions are present firstly. Then the coordinates of the x-ray systems are calibrated from the x-ray images of the grid pattern. Some experimental results on these calibrations are present and discussed.

  • PDF

X-선 영상 시스템의 정밀 캘리브레이션 기법 (An Accurate Calibration Technique for X ray Imaging System)

  • 조영빈;권대갑
    • 한국정밀공학회지
    • /
    • 제16권3호통권96호
    • /
    • pp.198-207
    • /
    • 1999
  • This paper presents an accurate algorithm for geometric calibration of X-ray imaging system. Calibration is a very important process for improving an imaging system performance. There has been a lot of previous works using linear camera modeling technique, where lens distortion is neglected and/or center of distortion is assumed to be known. Geometrical distortion of image intensifier, however, is very large and its center of distortion should be calculated. This paper presents a new calibration method to estimate the intensifier position and orientation, scale factor, distortion coefficient, magnification factor, and center of distortion using the least square method. We investigate the properties of the algorithm by computer simulation. Simulation results show that the parameters can be estimated accurately using the proposed algorithm.

  • PDF

A Volume Reconstruction Algorithm and a Coordinate Calibration of an X-ray Three Dimensional Imaging System

  • Roh, Young-Jun;Cho, Hyung-Suck;Jeon, Hyoung-Jo;Kim, Hyeong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.63.3-63
    • /
    • 2001
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. In this paper, we propose a three dimensional volume reconstruction method, which is an iterative method and as uniform and simulated algebraic reconstruction technique (USART). In this method, two or more x-ray images projected from different views are needed, and also the geometry of the imaging system need to be a priori identified well. That is to say, the relative locations between the x-ray source, imaging plane and the object should be determined exactly by calibration. To achieve this, we propose a series of coordinate calibration methods of the x-ray imaging system using grid pattern images. Some experimental results of these calibrations is presented and discussed in detail ...

  • PDF

Block-matching and 3D filtering algorithm in X-ray image with photon counting detector using the improved K-edge subtraction method

  • Kyuseok Kim;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2057-2062
    • /
    • 2024
  • Among photon counting detector (PCD)-based technologies, the K-edge subtraction (KES) method has a very high material decomposition efficiency. Yet, since the increase in noise in the X-ray image to which the KES method is applied is inevitable, research on image quality improvement is essential. Here, we modeled a block-matching and 3D filtering (BM3D) algorithm and applied it to PCD-based X-ray images with the improved KES (IKES) method. For PCD modeling, Monte Carlo simulation was used, and a phantom composed of iodine substances with different concentrations was designed. The IKES method was modeled by adding a log term to KES, and the X-ray image used for subtraction was obtained by applying the 3.0 keV range based on the K-edge region of iodine. As a result, the IKES image using the BM3D algorithm showed the lowest normalized noise power spectrum value. In addition, we confirmed that the contrast-to-noise ratio and no-reference-based evaluation results when the BM3D algorithm was applied to the IKES image were improved by 29.36 % and 20.56 %, respectively, compared to the noisy image. In conclusion, we demonstrated that the IKES imaging technique using a PCD-based detector and the BM3D algorithm fusion technique were very efficient for X-ray imaging.

암 모기 흡혈과정 가시화 (Visualization of blood sucking phenomena of a female mosquito)

  • 김보흠;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.114-115
    • /
    • 2007
  • As a carrier of malaria and sneak of blood, mosquitoes are regarded as an unpleasant insect. However, there are novel phenomena that happen inside a mosquito. Among them, we focused on the blood sucking function of a female mosquito. The main objective of this study was to investigate the mosquito's pumping mechanism in order to resolve the problem encountered when we inject or transport biologic fluids into a micro-chip. To analyze the pumping mechanism, we visualized the blood sucking process inside a female mosquito. Flow characteristics of blood flow in a proboscis were investigated experimentally using a micro-PIV velocity field measurement technique. The anatomical variation of head, thorax, abdomen which work as pumps and valves, was visualized using the syncrotron X-ray micro-imaging technique.

  • PDF

Restoration of Chest X-ray by Kalman Filter

  • Kim, Jin-Woo
    • Journal of information and communication convergence engineering
    • /
    • 제8권5호
    • /
    • pp.581-585
    • /
    • 2010
  • A grid was sandwiched between two cascaded imaging plates. Using a fan-beam X-ray tube and a single exposure scheme, the two imaging plates, respectively, recorded grid-less and grid type information of the object. Referring to the mathematical model of the Grid-less and grid technique, it was explained that the collected components whereas that of imaging plates with grid was of high together with large scattered components whereas that of imaging plate with grid was of low and suppressed scattered components. Based on this assumption and using a Gaussian convolution kernel representing the effect of scattering, the related data of the imaging plates were simulated by computer. These observed data were then employed in the developed post-processing estimation and restoration (kalman-filter) algorithms and accordingly, the quality of the resultant image was effectively improved.

방사광 위상차 현미경을 이용한 생체조직의 미세구조 영상 (Synchrotron Radiation Imaging of Tissues Using Phase Contrast Technique)

  • 강보선;이동열;김기홍
    • 한국방사선학회논문지
    • /
    • 제2권2호
    • /
    • pp.23-30
    • /
    • 2008
  • 방사광 X-선 현미경은 임상실험에 유용한 도구로 높은 배율과 고 해상도로 동물 장기조직 시료의 세부 구조를 관찰할 수 있다. X-선 영상은 위상 대조도 메커니즘으로 설명할 수 있다. 우리는 쥐의 꼬리, 신경 및 허파의 in-vivo 및 in-vitro위상 대조도 영상을 8 KeV mono 빔으로부터 10배 현미경대물렌즈와 CCD 카메라를 이용하여 얻었다. 기존의 흡수 X-선 영상 보다 SR 영상이 세밀한 구조의 높은 분해능 영상을 볼 수 있었다. SR 영상은 생물학, 재료 및 임상 연구에 무한한 가능성을 가지고 있다.

  • PDF

경 엑스선 위상차 현미경을 이용한 유방 조직의 방사광 영상 (Synchrotron Radiation Imaging of Breast Tissue Using a Phase-contrast Hard X-ray Microscope)

  • 정영주;봉진구;박성환
    • 한국의학물리학회지:의학물리
    • /
    • 제22권3호
    • /
    • pp.117-123
    • /
    • 2011
  • 방사광 영상은 내부가 보이지 않는 생물학적 검체의 구조를 관찰하는데 사용될 수 있으며, 조직의 고정이나 염색없이 비침습적으로 조직의 미세 구조를 관찰하는데 유용하다. 본 연구에서는 포항방사광가속기의 1B2 빔라인에서 개발한 경엑스선(hard X-ray) 현미경을 이용하여 11.1 KeV의 에너지에서 인간 유방 조직의 현미경적 영상을 얻고자 하였으며, 고해상도의 영상을 얻기 위해 동심원 회전판(zone plate)과 위상차 영상기법을 사용하였다. 실험 결과 경 엑스선 현미경을 이용하여 유방 섬유낭성변화와 유방암 조직의 방사광 미세 영상을 얻었으며, 이들 영상의 공간 해상도는 60 nm로 각각의 유방 조직의 미세 구조를 관찰하기에 충분하였다. 또한 방사광 미세 영상과 기존의 유방촬영 영상을 비교하였을 때, 방사광 미세 영상에서 각 조직의 특징적인 형태학적 변화가 더 뚜렷하게 나타나는 것을 관찰할 수 있었다. 결론적으로, 경엑스선 위상차 현미경을 이용한 방사광 영상은 유방 질환의 진단에 많은 도움을 줄 수 있을 것으로 생각되며, 임상적으로나 여러 연구 목적으로 유용하게 사용될 수 있을 것으로 기대된다.

인쇄회로기판 검사를 위한 단일조사 이중에너지 엑스선 영상기법의 유용성에 관한 연구 (Feasibility of Single-Shot Dual-Energy X-ray Imaging Technique for Printed-Circuit Board Inspection)

  • 김승호;김동운;김대천;김준우;박지웅;박은평;김진우;김호경
    • 방사선산업학회지
    • /
    • 제9권3호
    • /
    • pp.137-141
    • /
    • 2015
  • A single-shot dual-energy x-ray imaging technique has been developed using a sandwich detector by stacking two detectors, in which the front and rear detectors respectively produce relatively lower and higher x-ray energy images. Each detector layer is composed of a phosphor screen coupled with a photodiode array. The front detector layer employs a thinner phosphor screen, whereas the rear detector layer employs a thicker phosphor screen considering the quantum efficiency for x-ray photons with higher energies. We have applied the proposed method into the inspection of printed circuit boards, and obtained dual-energy images with background clutter suppressed. In addition, the single-shot dual-energy method provides sharper-edge images than the conventional radiography because of the unsharp masking effect resulting from the use of different thickness phosphors between the two detector layers. It is promising to use the single-shot dual-energy x-ray imaging for high-resolution nondestructive testing. For the reliable use of the developed method, however, more quantitative analysis is further required in comparisons with the conventional method for various types of printed circuit boards.

암모기 흡혈과정에 대한 실험적 연구 (Experimental research on blood sucking phenomena of a female mosquito)

  • 김보흠;이정엽;이상준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.105-106
    • /
    • 2008
  • As a carrier of malaria and sneak of blood, mosquitoes are an unpleasant insect. However, there are several unknown natural secretes related with mosquitoes. Among them, we focused on the blood sucking process of a female mosquito. The main objective of this study is to understand the mosquito's blood sucking mechanism that can be used to resolve the problem encountered in the injection or transport of infinitesimal biological fluids in a micro-chip. At first, the velocity fields of blood-sucking flow in a proboscis were measured using a micro-particle image velocimetry (PIV) technique. The velocity signals of flow in the proboscis show periodic variation. This seems to be resulted from the beating of the pharyngeal pump which works as driving power. To analyze the pumping mechanism, the temporal variation of the pharyngeal pump was visualized using the synchrotron X-ray micro-imaging technique. The volume variation was estimated by the help of digital image processing techniques. Once the main mechanism of blood sucking process was found, a effective micro-pumping system with high efficiency would be developed in near future.

  • PDF