Development of a truncation artifact reduction method in stationary inverse-geometry X-ray laminography for non-destructive testing

  • Kim, Burnyoung;Yim, Dobin;Lee, Seungwan
    • Nuclear Engineering and Technology
    • /
    • 제53권5호
    • /
    • pp.1626-1633
    • /
    • 2021
  • In an industrial field, non-destructive testing (NDT) is commonly used to inspect industrial products. Among NDT methods using radiation sources, X-ray laminography has several advantages, such as high depth resolution and low computational costs. Moreover, an X-ray laminography system with stationary source array and compact detector is able to reduce mechanical motion artifacts and improve inspection efficiency. However, this system, called stationary inverse-geometry X-ray laminography (s-IGXL), causes truncation artifacts in reconstructed images due to limited fields-of-view (FOVs). In this study, we proposed a projection data correction (PDC) method to reduce the truncation artifacts arisen in s-IGXL images, and the performance of the proposed method was evaluated with the different number of focal spots in terms of quantitative accuracy. Comparing with conventional techniques, the PDC method showed superior performance in reducing truncation artifacts and improved the quantitative accuracy of s-IGXL images for all the number of focal spots. In conclusion, the PDC method can improve the accuracy of s-IGXL images and allow precise NDT measurements.

격자간섭계를 위한 탈봇 패턴 연구 (Study on Talbot Pattern for Grating Interferometer)

  • 김영주;오오성;김종열;이승욱
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권1호
    • /
    • pp.39-49
    • /
    • 2015
  • 격자 간섭계(grating interferometer)는 방사선 영상분야의 새로운 기술로서, 흡수 영상(absorption imaging)뿐만 아니라 위상차 영상(phase contrast imaging)과 다크필드 영상(dark field imaging)을 제공한다. 격자 간섭계는 크게 탈봇 효과(talbot effect)를 이용하는 탈봇 간섭계와 탈봇-라우 효과(talbot-lau effect)를 이용하는 탈봇-라우 간섭계로 나뉘는데, 일반적인 방사선 영상시스템과 달리 방사선의 간섭을 예측하고 적용하는 것이 중요하다. 본 연구에서는 현재 부산대학교 중성자 및 방사선 공학 연구실에서 보유하고 있는 엑스선 격자 세트와 중성자 격자 세트를 이용하여 탈봇 간섭 패턴 및 탈봇-라우 간섭 패턴을 제작하였다. 이를 통해 방사선의 파동 거동에 따른 간섭 세기의 변화를 예측하고, 격자 간섭계를 구성하는 각 요소들을 계산했다. 그리고 격자의 종류 및 위상차 물체에 대한 탈봇 간섭 패턴 및 탈봇-라우 간섭 패턴을 예측하였다.

미소초점엑스선원 개발을 위한 전산모사 (Computer Simulation for Development of Micro-Focus X-ray Generator)

  • 김성수;이연승;김도윤;고동섭
    • 한국진공학회지
    • /
    • 제20권6호
    • /
    • pp.403-408
    • /
    • 2011
  • MFX tube를 개발하기 위하여, MFX tube 내에서 전계방출음극으로부터 방출된 전자의 궤적을 SIMION 프로그램을 이용하여 전산모사하였다. 전자의 출발위치와 상관없이 emitter에서 방출된 전자빔을 한곳에 집중시킬 수 있는 optimum extractor voltage Ve가 존재한다는 것을 알아내었다. Extractor voltage Ve는 source voltage Vs에 따라 변하지만, 두 전압의 비율(Ve/Vs)는 항상 일정하고, 그 값은 99.4%였다. Source와 extractor에 인가된 전압의 비율(Ve/Vs)이 99.4%일 때, 교차점에서의 빔 직경은 $1.2{\mu}m$였다. MFXG의 초점 크기는 교차점에서의 beam diameter보다 작을 수 없기 때문에, 교차점에서의 beam diameter을 작게 할 수 있는 조건을 찾는 것은 중요하다. 따라서 위의 두 결과는 MFX tube의 개발에 있어서 매우 중요한 결과로 판단된다.

바나듐 페라이트 박막의 결정구조 및 자기적 성질에 관한 뫼스바우어 분광학적 연구 (Mössbauer Study of Crystallographic and Magnetic Properties in Vanadium Ferrite(VxFe3-xO4) Thin Films)

  • 박재윤;김광주
    • 한국자기학회지
    • /
    • 제18권1호
    • /
    • pp.19-23
    • /
    • 2008
  • Sol-gel 법을 이용하여 $V_xFe_{3-x}O_4$(x=0.0, 0.15, 0.5, 1.0) 박막 시료을 만들어 V 치환에 따른 $Fe_3O_4$의 결정구조적 특성을 X-ray diffraction(XRD)과 X-ray photoelectron spectroscopy(XPS)로 조사하였다. 특히 Fe 이온의 전하상태와 거동에 관하여 강력하게 조사할 수 있는 conversion electron $M\"{o}ssbauer$(CEMS) 분광법을 이용하여 양이온들의 거동과 초미세 자기적 성질을 분석하였다. X-선 회절실험의 결과 $V_xFe_{3-x}O_4(X{\leq}1.0)$ 박막 시료들의 결정구조는 스피넬구조로서 V 조성값 증가에 따라 격자상수값이 약간 증가함을 보여준다. XPS 조사에서 x값 증가에 따라 처음에는 $V^{3+}$ 이온이 B-자리의 $Fe^{3+}$ 이온을 주로 치환하고 x값이 더 커지면서 $V^{2+}$ 이온의 $Fe^{2+}$ 치환도 발생되는 것으로 나타났다. 이것은 격자상수값이 증가하는 분석 결과를 잘 설명하여 준다. CEMS 측정 결과에서 나타난 양이온 거동은 주로 B-자리의 $Fe^{3+}$ 이온에 대한 $V^{3+}$ 이온 치환이 나타나고, V 조성값이 더 크게 증가함에 따라 $V^{2+}$ 이온의 $Fe^{2+}$ 치환도 발생됨을 알 수 있었다. 그리고 이것은 V 치환이 Fe 이온 주위의 국부적 전하분포와 대칭성의 변화를 가져와 초미세 자기적 성질의 변화를 초래함을 의미한다.

다이오드 검출기를 이용한 초소형 X선관(Miniature X-ray Tube)의 반가층 측정 (HVL Measurement of the Miniature X-Ray Tube Using Diode Detector)

  • 김주혜;안소현;오윤진;지윤서;허장용;강창무;서현숙;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.279-284
    • /
    • 2012
  • X선은 방사선 진단과 치료 분야에 있어서 다양하고 광범위하게 이용되고 있으며, 최근에는 방사선 치료용 초소형 X선관이 개발되었다. 초소형 X선관은 조사 목적 부위에 직접 삽입하여 사용되므로 제작 시준기에 따라 다양한 각도로 X선 조사가 가능하고, 검사 목적 외의 환자 피폭선량을 최소화한다. 이러한 초소형 X선관의 장점을 이용해서 X선 영상을 획득하는데 적용한다면 X선 진단 분야의 새로운 장을 열 것으로 기대된다. 하지만 초소형 X선관은 본래 치료용으로 설계되었기 때문에 진단용 장비에 적합한 시준기, 필터(added filter) 등이 필요하다. 따라서 자체 제작한 시준기와 필터를 적용하여 초소형 X선관의 빔 특성이 진단용에 적합한지 평가 하였고, 이를 위해서 다이오드 검출기를 이용하여 반가층을 측정하고 측정의 가능성을 평가하였다. 본 연구에서는 Si PIN Photodiode type인 Piranha 검출기(Piranha, RTI, Sweden)를 사용하여 필터 적용 유무에 따른 초소형 X선관의 반가층을 측정하고, 알루미늄 필터를 사용한 측정을 통하여 Piranha 검출기의 반가층 측정의 정확성을 평가하였다. 측정 결과에 따르면 초소형 X선관의 반가층은 필터의 장착에 따라 약 1.9배 증가하여 진단용 방사선 발생 장치의 적합성을 확인하였다. Piranha 검출기의 반가층 자동 측정값은 필터를 미장착한 경우에 실제 반가층 측정값에 비해 50% 높게 측정되어 적용이 불가능하나, 필터를 장착한 경우에는 실제 반가층 측정값과 약 15%의 차이로 감소되었다. 따라서 진단용 필터를 적용했을 경우는 Piranha 검출기의 반가층 자동측정이 가능하여 kV-X선 특성평가를 수월하게 수행할 것으로 기대된다.

Radiation exposure to the eyes and thyroid during C-arm fluoroscopy-guided cervical epidural injections is far below the safety limit

  • Choi, Eun Joo;Go, Gwangcheol;Han, Woong Ki;Lee, Pyung-Bok
    • The Korean Journal of Pain
    • /
    • 제33권1호
    • /
    • pp.73-80
    • /
    • 2020
  • Background: The aim of this study was to evaluate radiation exposure to the eye and thyroid in pain physicians during the fluoroscopy-guided cervical epidural block (CEB). Methods: Two pain physicians (a fellow and a professor) who regularly performed C-arm fluoroscopy-guided CEBs were included. Seven dosimeters were used to measure radiation exposure, five of which were placed on the physician (forehead, inside and outside of the thyroid protector, and inside and outside of the lead apron) and two were used as controls. Patient age, sex, height, and weight were noted, as were radiation exposure time, absorbed radiation dose, and distance from the X-ray field center to the physician. Results: One hundred CEB procedures using C-arm fluoroscopy were performed on comparable patients. Only the distance from the X-ray field center to the physician was significantly different between the two physicians (fellow: 37.5 ± 2.1 cm, professor: 41.2 ± 3.6 cm, P = 0.03). The use of lead-based protection effectively decreased the absorbed radiation dose by up to 35%. Conclusions: Although there was no difference in radiation exposure between the professor and the fellow, there was a difference in the distance from the X-ray field during the CEBs. Further, radiation exposure can be minimized if proper protection (thyroid protector, leaded apron, and eyewear) is used, even if the distance between the X-ray beam and the pain physician is small. Damage from frequent, low-dose radiation exposure is not yet fully understood. Therefore, safety measures, including lead-based protection, should always be enforced.

GENERATION OF RAY CLASS FIELDS OF IMAGINARY QUADRATIC FIELDS

  • Jung, Ho Yun
    • 충청수학회지
    • /
    • 제34권4호
    • /
    • pp.317-326
    • /
    • 2021
  • Let K be an imaginary quadratic field other than ℚ(${\sqrt{-1}}$) and ℚ(${\sqrt{-3}}$), and let 𝒪K be its ring of integers. Let N be a positive integer such that N = 5 or N ≥ 7. In this paper, we generate the ray class field modulo N𝒪K over K by using a single x-coordinate of an elliptic curve with complex multiplication by 𝒪K.

디지털 유방촬영장치에서 다엽 조리개 적용으로 인한 화질과 선량의 변화 (Variation of Image Quality and Dose by Applying Multi-Leaf Collimator for Digital Mammography)

  • 권순무;김부순;박형준;강영한
    • 한국방사선학회논문지
    • /
    • 제9권7호
    • /
    • pp.535-540
    • /
    • 2015
  • X선 조사야(X-ray beam field)는 X선관 앞에 부착된 선속제한기구(beam limiting device)인 조리개(collimator)에 의해 조절된다. 조리개는 1차 X선을 조절하여 환자의 피폭선량을 감소시키고 산란선량을 감소시켜 영상의 화질을 향상시키는 중요한 기능을 한다. 그러나 유방촬영장치의 조리개에 대해서 따로 규정되어 있지 않으며 상업화된 장치에서는 조사야가 사각형으로 조절되는 조리개를 사용하고 있다. 최근 디지털 유방촬영장치의 보급이 확대되고 있으나 film/screen방식에서부터 적용되던 사각형으로 조사야가 조절되는 조리개가 사용되고 있다. 따라서 본 연구에서는 디지털 유방촬영에서 조사야 조절 사용에 대한 실태조사 후 유방의 크기와 모양에 따라 조사야를 조절할 수 있는 다엽조리개를 제작 후 적용했을 때 영상의 화질변화와 평균유선선량, 면적선량 값의 변화를 알아보았다. 사각형으로 조사야가 조절되는 조리개와 비교하여 다엽 조리개를 적용한 영상에서 통계적으로 유의한 차이가 없었으며 DAP값 또한 50.72% 감소되었다. 따라서 디지털 유방촬영장치에서 조사야를 최적화하기 위한 자동조사야조절장치 개발이 환자 피폭선량 감소에 도움이 될 것으로 판단된다.

Mechanism of the X-ray and Soft Gamma-ray Emissions from the High Magnetic Field Pulsar: PSR B1509-58

  • Wang, Yu;Takata, Jumpei;Cheng, Kwong Sang
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권2호
    • /
    • pp.91-94
    • /
    • 2013
  • We use the outer gap model to explain the spectrum and the energy dependent light curves of the X-ray and soft ${\gamma}$-ray radiations of the spin-down powered pulsar PSR B1509-58. In the outer gap model, most pairs inside the gap are created around the null charge surface and the gap's electric field separates the opposite charges to move in opposite directions. Consequently, the region from the null charge surface to the light cylinder is dominated by the outflow current and that from the null charge surface to the star is dominated by the inflow current. We suggest that the viewing angle of PSR B1509-58 only receives the inflow radiation. The incoming curvature photons are converted to pairs by the strong magnetic field of the star. The X-rays and soft ${\gamma}$-rays of PSR B1509-58 result from the synchrotron radiation of these pairs. The magnetic pair creation requires a large pitch angle, which makes the pulse profile of the synchrotron radiation distinct from that of the curvature radiation. We carefully trace the pulse profiles of the synchrotron radiation with different pitch angles. We find that the differences between the light curves of different energy bands are due to the different pitch angles of the secondary pairs, and the second peak appearing at E > 10 MeV comes from the region near the star, where the stronger magnetic field allows the pair creation to happen with a smaller pitch angle.

Cu 치환에 따른 $(Ru_{1-x}Cu_x)Sr_2(Eu_{1.34}Ce_{0.66})Cu_2O_z$ 계의 초전도 특성 (Effect of Cu substitution on Superconductivity in $(Ru_{1-x}Cu_x)Sr_2(Eu_{1.34}Ce_{0.66})Cu_2O_z$ System)

  • 이호근
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.67-71
    • /
    • 2009
  • The effect of Cu substitution on the structural and superconducting properties of the $(Ru_{1-x}Cu_x)Sr_2(Eu_{1.34{\cdot}}Ce_{0.66})Cu_2O_z$ system with x = 0, 0.25 and 0.5 prepared under ambient pressure have been investigated. The X-ray diffraction patterns indicated that the Ru ions are replaced by the Cu ions. It is found that the Cu substitution for Ru significantly reduces the ferromagnetic component of field-cooled magnetic susceptibility, but results in a small change in diamagnetic onset transition temperature of zero-field-cooled magnetic susceptibility. In contrast to the Ru $Sr_2(Eu_{1.34{\cdot}}Ce_{0.66})Cu_2O_z$, bulk Meissner effect is observed in the field-cooled magnetization measurements of the Cu doped samples. The experimental results are discussed in connection with the spontaneous vortex phase interpretation.

  • PDF