• Title/Summary/Keyword: X-ray Examination

Search Result 657, Processing Time 0.025 seconds

Conservation Treatment of Gilded bronze Sarria Reliquary Excavated from Songlim Temple Tower (송림사(松林寺) 전탑(塼塔) 출토(出土) 금동제(金銅製) 사리장치(舍利裝置)의 보존처리(保存處理))

  • Kim, Jong-oh
    • Conservation Science in Museum
    • /
    • v.3
    • /
    • pp.1-7
    • /
    • 2001
  • The gilded bronze Sarria reliquary(National Treasure No. 325-1) excavated from a five story tower in Songlim Temple is considered as a very important Sarria reliquary of Unified Silla Dynasty Kingdom along with glass Sarria containers excavated in package. It was found that this Sarria container was in a very weak condition in the conservation dept. of National Museum of Korea due to the wearing of the inside wood and the decay of the gilded bronze, so a conservation treatment was conducted by focusing on the prevention of further decay and wearing. Also because there is little information about Sarria reliquary, detailed investigation by means of precision actual measurements, microscopic examination and X-ray photography was carried out.

A Study for Establishment of Diagnostic Reference Level of Patient Dose in Skull Radiography (우리나라의 두부 엑스선검사에서의 환자선량 권고량)

  • Lee, Jung-Eun;Jeong, Jin-Baek;Lee, Hyun-Koo;Lim, Chun-Il;Son, Hye-Kyung;Jin, Hyun-Mi;Kim, Byung-Woo;Yang, Hyun-Kyu;Kim, Hyeog-Ju;Kim, Dong-Sup;Lee, Kwang-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.111-116
    • /
    • 2010
  • Ionizing radiation is most widely used for X-Ray examination among all artificial radiation exposure, it takes up the largest proportion. Even in Korea, the medical exposure by diagnostic X-Ray examination takes up 17.4% of all radiation exposure. It takes up 92% even in artificial radiation exposure. There were 111,567 cases X-Ray radiography for skull diagnosis in 2007, which is 3% annual increase since 2004. Thus, It is need to establish the diagnostic reference level and the medical facilities as a diagnostic reference level to optimize radiation protection of the patients and to reduce the doses of X-ray. In this paper, we survey patient dose on skull radiography - collected from 114 medical facilities nationwide by using human phantom and glass dosimeter. When the patient dose for the skull radiography was measured and evaluated to establish the diagnostic reference level, 2.23 mGy was established for posterior-anterior imaging and 1.87 mGy for lateral imaging was established. The posterior-anterior skull radiography entrance surface dose of 2.23 is less than the guidance level of 5 mGy from the global organizations such as World Health Organization (WHO) and International Atomic Energy Agency (IAEA), and 1.87 mGy for the lateral skull imaging is less than the guidance level of 3 mGy, which is guided by the global organizations such as World Health Organization (WHO) and International Atomic Energy Agency (IAEA).

A Study on the Guardian's Perception of Attending Patient in Pediatric Radiography (소아 방사선 검사 시 보호자 참여에 대한 인식도 조사)

  • Kwak, JongHyeok;Jeong, JaeBeom
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.189-201
    • /
    • 2014
  • The purpose of this study was to survey guardian's opinion on assisting pediatric radiography and their level of awareness of radiation, improving the quality of pediatric radiography. In this study, the recognition was analyzed for 210 parents of child patients in Pusan National University Hospital from August 20 to September 15, 2013. A total of 66.2 percent of the respondents said they had participated in pediatric radiography in the past. The reason why they did is "Radiologist's request", the highest. According to the survey, 84.3 percent said they thought it is necessary to attending patient in pediatric radiography. "The stability of the child" is the reason for it. And respondents who thought there's no need to do that answered back, the reason for this is "Radiologist's work." There was a significant difference on the psychological state for the medical radiation by gender and child age. (p<0.05) In the analysis of recognition for the radiation, there was the significance by gender and education. (p<0.05) Regarding the awareness of the radiation protector, there was a statistical significance in age, gender, child age and education. (p<0.05) Considering the results, pediatric patient's guardians recognized that it is necessary to attend a child on X-ray for their child's stability and accurate exam above all. It must make guardians wear X-ray protector and radiologist should let the guardians recognize the X-ray examination method, before starting pediatric x-ray. It needs to improve the atmosphere of the examination room and to be considered to take visual and auditory approaches in comfort for reducing the children's fear and anxiety.

Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control (자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향)

  • Kang-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.257-265
    • /
    • 2024
  • In this study, we applied AEC(Auto Exposure Control), which is used in many chest examinations, to evaluate whether medical devices inserted into the body affect the dose and image quality of chest images. After attaching three HIMD(Human implantable medical devices) to the ion chamber, the Monte Carlo methodology-based program PCXMC(PC Program for X-ray Monte Carlo) 2.0 was applied to measure the effective dose by inputting the DAP(Dose Ares Product) value derived from the Pacemaker and CRT and Chemoport Additionally, to evaluate image quality, we set three regions of interest and one noise region on the chest and measured SNR and CNR. The final study results showed significant differences in DAP and Effective dose. There was a significant difference between Pacemaker and CRT when AEC was applied and not applied. (p<0.05) When applied, the dose increased by 37% for Pacemaekr and 52% for CRT. Chemoport showed a 10% increase in effective dose depending on whether AEC was applied, but there was no significant difference. (p>0.05) In the image quality evaluation, there was no significant difference in image quality between all HIMD insertions and AEC applied or not. (p>0.05) Therefore, when the HIMD was inserted into the chest during a chest x ray and overlapped with the ion chamber sensor, the effective dose increased, and there was no difference in image quality even at a low dose without AEC. Therefore, when performing a chest X-ray examination of a patient with a HIMD inserted, it is considered that performing the examination without applying AEC is a method that can be considered to reduce the patient's radiation exposure.

Characteristics of Individuals Seeking Comprehensive Health Check-ups (종합 건강검진을 원하는 피검진자의 건강특성에 관한 연구)

  • 성미혜
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.3
    • /
    • pp.563-576
    • /
    • 1997
  • This study was carried out to identify basic data for more efficient operation of comprehensive health check-up centers in the national health care system. The researcher reviewed and analyzed the main symptoms of the subjects according to sex, age, occupation and positive rate in the screening tests of a comprehensive health check-up, performed at one comprehensive health check-up center in located in a hospital. The subjects were 512 persons who had a check-up at the comprehensive health check-up, center in K university hospital in Seoul from October 2, 1996 to March 30, 1997. A questionaire developed by the researcher to obtain subject's general characteristics, main symptoms, medical examination, diagnosed disease was used as the tool for the study. The researcher analyzed the data with SPSS PC/sup +/ program. : the distribution of the subject's general characteristics and main symptoms was described with percentages and the difference between main symptoms and screening tests analyzed with X²-test, t-test, ANOVA. The result of this study are as follows : 1. For the distribution of diagnosis in males. liver disease was most frequent and hypertension was second : in females, hypertention and liver disease were not common in that order. 2. The most common complaints were indigestion in the digestive system, sputum in the respiratory system, irregular heart beat in the cardiovascular system, frequent urine in the urinary system vertigo in the hematologic system. 3. The main symptoms according to sex were for females, a statistically siguificant higher rate of complaints in the digestive system, cardiovascular system, urinary system, hematologic system, musculoskeletal, mental & nervous system as compared to males. 4. The main symptoms according to age were that in the the second decade there wara higher rate of complaints in the digestive system, and cardiovascular system than in the older age groups : and in the fifth decade more in the musculoskeletal system. 5. The main symptoms according to occupation were that formers and fishers had a higher rate of complaints in the mental and nervous system as compared to other occupation groups : and office workers, in gynecology. 6. The main symptoms according to diagnosis, were symptoms of the digestive system, frequent in liver disease : symptoms of the cardiovascular system in allergic disease. 7. The screening tests which showed the highest rates were UGI /FGS, PFT : In males a higher rate of abnormality was seen in abdominal ultrasono- graphy and in, females, in mammography. 8. In screening tests according to sex, males showed a higher positive rate for chest X-rays, and LFT, and females, in mammography, pap smear, CBC. 9. In screening tests according to age, higher positive rates of obesity, high blood pressure, chest X-ray, mammography, pap smear, FBS, CBC, urine test were seen in the fifth decade : PFT and abdominal ultrasonography in the third decade. The subjects who wanted comprehensive health check-up were not asymptomatic but had an illness with several symptoms. It is found that the most frequent diagnosed diseases were hypertention and liver disease. So proper observations must be done for them. Comprehensive health check-ups should be changed to a comprehensive examination including treatment beyond examination for those subjects with positive results.

  • PDF

Comparative Health Status of Rural Urban and Aged Perosons by Some Screening Tests (농촌 및 대도시의 노인건강진단에 있어서의 검사치 비교 고찰)

  • Han, In-Soo;Hong, Kwang-Sun;Park, Sun-Ju;Rim, Han-Jong
    • Journal of agricultural medicine and community health
    • /
    • v.14 no.1
    • /
    • pp.5-15
    • /
    • 1989
  • To compare the health status of rural and urban aged persons(over 65 years old) by an abnormality of a hematologic and some biochemical values as well as urinalysis and chest X-ray, following examinations were done on 8,756(male : 4,339: female 4,417) by hemoglobin, total cholesteol, GOT, and glucose, on 9,207(male: 4,467; female : 4.740) by urinalysis and on 9,148(male : 4,426: female : 4,722) by chest X-ray. The results are as follows: 1) The proportion of outlier of normal range of the GOT(over 40 unit) showed higher in rural aged persons(5.3%) than in urban aged(2.8%). There was no significant difference in both of urban and rual female, but the rural male(7.4 showed significantly higher than the urban male(3.9% ). 2) The proportion of abnormality of the total cholesterol value(over 260 mg/dl) was 7,0% in urban and 1.7% in rural aged persons. In the male, there was no significant difference in both urban(2.2%) and rural(1.4%), however the urban female(10.5%) showed significantly higher than the rural female(2.2%). 3) In the blood glucose level, the proportion of abnormality(over 120 mg/dl) showed 17.1% in urban and 19.3% in rural aged persons. The rural aged persons in both sexes(male : 18.1% : female : 20.7%) were relatively higher abnormality rates than those of the urban aged(male : 15. 3%: female : 18.4% ) respectively. 4) The proportion of abnormality of hemoglobin level(less than 12.0 g/dl in male: less than 11.0 g/dl in female) showed 7.1% in urban and 2.6%J in rural aged persons. The urban aged persons in both sexes(male : 8.3%: female 6.3%) were relatively higher abnormality rates than those of the rural aged(male : 3.0%: female : 2.2%) 5) In the urinalysis by urine stix(Korea Green Cross Co.), the positive rates of urine protein were 1.0% in urban and 0.5% in rural aged per-sons, and there was no any significant differences in both areas by sex. 6) The positive rates of urine glucose in urban aged persons(5.8'% : male : 7.3% : female : 4.7%). showed relatively higher than those of rural aged (3.4% : male : 3.9%: female : 2.8%). 7) The positive findings of pulmonary tuberculosis by indirect X-ray examination were observed in 7.7% of aged persons in both rural and urban areas respectively. However, the positive rates of male in both areas(urban : 12.8% ; rural : 10.0%) showed higher than those of female (urban 4.2% ; rural 5.0%).

  • PDF

Amendment of the Inspection Standard for Diagnostic Radiation Equipment Applying IEC 60601-1-3: Medical Electrical Equipment - Part 1-3: General Requirements for Basic Safety and Essential Performance - Collateral Standard: Radiation Protection in Diagnostic X-ray Equipment (KS C IEC60601-1-3: 의료용 전기기기-제1-3부: 기본 안전 및 필수 성능에 관한 일반 요구사항-보조표준: 진단용 X선 장치의 방사선 방어를 적용한 진단용 방사선 발생장치의 검사기준 개선안)

  • Park, Hye-Min;Kim, Jung-Min;Kim, Jung-Su;Kim, Seong-Ok;Choi, Young-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.493-504
    • /
    • 2018
  • The diagnostic radiation equipment is managed in accordance with the "Rules for Safety Management of Diagnostic Radiation Equipment" enacted in 1995. The equipments should be inspected before use and every three years after use in accordance with the [Appendix 1] of the same rule. The inspection standard has been maintained without particular revision since enacted. But, over the past two decades new types of equipments have been manufactured and used. So, it is necessary to revise [Appendix 1] by making inspection items and inspection standards. In this study, we revised the classification system of equipments and reviewed international standards of IEC 60601 series, IEC 61223 series and AAPM TG 18 On-line Report No.03. And identified the problem of current inspection standards. Through this, we revised, deleted and added the inspection items and inspection standard of each equipment to meet the domestic circumstances. As a result of the study, we reorganized the classification system of equipment which are current classified as 5 classes into 22 classes as X-ray system etc. (7 classes), CT system etc. (5 classes) and Dental X-ray system etc. (10 classes). And then, we developed 70 inspection items for 6 types of equipments according to the reorganized classification system of equipments. The inspection items and inspection standards derived from this study have been proposed to the KCDC and will be applied to the revision of the Rule's [Appendix 1]. Therefore, we expect to be used as reference materials for domestic medical center, inspection institutions, and equipment manufacturing import companies.

Effects of Iyengar Yoga Practice for 12 weeks on Lower Body Imbalance in Middle-aged Women (중년여성의 12주간 아헹가 요가 수련이 하체 불균형에 미치는 영향)

  • Park, Yunha;Kim, Donghee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.431-440
    • /
    • 2017
  • The purpose of this study was to investigate the effects of Iyengar yoga practice on the lower body imbalance in middle-aged women. The subjects (n=24), who had not performed yoga training prior to this study (and) were not attending any other training programs, participated after undergoing an X-RAY examination with the Gonstead Technique and then their lower body imbalance (was reevaluated). The subjects completed the yoga program for 12 weeks (3 times per week, 90 minutes per session). The data were analyzed with the paired t-test and alpha was set at 0.05. It was found that 1) the height differences between the right and left iliac crests (p < 0.001), width (p < 0.001) and length (p < 0.001) differences between the right and left iliac fossa, and width differences between the right and left sacrum (p < 0.001) were significantly reduced after the training program. In addition, 2) the lower limb length discrepancy was significantly reduced (p < 0.001). Our data suggest that Iyengar yoga training for 12 weeks reduces the pelvic imbalance and length differences between the right and left lower limbs in middle-aged females.

Success and survival rate of the implant with crestal sinus lift using S-reamer and gel-type graft material: A retrospective study by more 5-years follow check up (S-reamer와 겔 형태의 이식재를 이용한 치조정 접근법을 통한 상악동 거상술 임플란트의 성공률과 생존율: 5년 이상 추적 관찰을 통한 후향적 연구)

  • Kim, Jong Jin;Cho, Sung Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.23-29
    • /
    • 2020
  • Purpose: The purpose of this retrospective study was to evaluate the method using the S-reamer and gel-type graft material by the success rate and survival rate. Materials and methods: Implantation period was from 2008 to 2014, Follow check up year is 2019. There were 59 patients and 117 implants. All implants were placed in the posterior maxilla with the sinus lift. The patients population consisted of 34 men and 25 women, ranging from 19 to 75 years. The residual bone heights were from 1 mm to 6 mm. Sinus was perforated with S-reamer without membrane tearing and gel type bone graft material was used for membrane lifting and filling the space. all implants were placed simultaneously. Panoramic X-ray was taken. After 5 - 6 months healing period, final prostheses were restored. After more 5-years implant surgery, Panoramic X-ray was obtained and X-ray analysis and clinical examination were performed. Success criteria was referred to a Buser's success critera. All implants were classified to success implant, survival implant, failed implant. A success implant was satisfying success criteria, a survival implant was a implant that was acute infection with suppuration and bone loss, a failed implant was a implant that was mobile, removed. Results: Five implants were removed, and 4 implants had infected with bone loss. Survival rate was 95.7% and success rate was 92.3%. Conclusion: This retrospective study presented that this method with S-reamer and gel-type graft material was a successful treatment without membrane tear in the condition of 1-6 mm residual bone height.

Reducing Radiation Exposure During X-ray Imaging of Both Hip AP (엉덩관절 정면 검사 시 환자 피폭 감소)

  • Shin, Seong-Gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.313-320
    • /
    • 2016
  • This research has been conducted to investigate the method of reducing patients' radiation exposure during X-ray imaging of Both Hip Ap examination by removing the grid. When using the grid with 60 kV and a non-filter, the Entrance Surface Dose was 4.77 mGy, and the result was highest and 34 times higher than the lowest measurement when removing the grid with 90 kV, and 0.3 mmCu filter. Based on the ICRP Pub. 60 at the level of 70 kV, the Effective Dose of testis and ovary was 0.255 mSv when using the grid, and that result was approximately 5.2 times higher than the 0.049 mSv when removing the grid. Based on the ICRP Pub. 103 at the level of 70 kV, the Effective Dose of testis and ovary was 0.090 mSv when using the grid, and that result was approximately 4.5 times higher than the 0.020 mSv when removing the grid. When using the grid, the range of Exposure Index was 671 to 782, and when removing the grid, the range of Exposure Index was 513 to 606, and both results were at optimal exposure conditions and valid diagnostic imaging after evaluations. Therefore, removing the grid during X-ray imaging of Both Hip Ap will help reduce patients radiation exposure.