• Title/Summary/Keyword: X-ray Examination

Search Result 657, Processing Time 0.022 seconds

A Study on the Usefulness of an Examination Information Printout during Ordinary X-Ray Examinations (일반촬영 검사 시 검사안내 유인물의 유용성에 관한 고찰)

  • Kang, Sang-Oh;Hong, Seong-Kwon;Son, Seok-Ho;Lee, Min-Woo;Kim, Kyeong-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.13-20
    • /
    • 2012
  • In a normal x-ray examination, the cooperation of a patient in positioning greatly influences the improvement of work performance, the quality of the images and the reduction in time spent on the examination. An attempt was made to discover the connection between an examination information printout and the effects of the examination by informing the patient before the examination on the examination positions in order to increase the level of cooperation by the patient and by surveying the degree of satisfaction of the patient during the examination proceedings. An examination information printout was prepared on five positions that patients consider to be difficult while receiving normal x-ray examinations and were shown to 257 male and female patients between the ages of 30 to 79 who had visited this hospital between January 1 to February 29, 2012 or to a person who had accompanied the patients before the examination to research the degree of satisfaction regarding the printout. In addition, the examination explanation printout was given to Radiologic Technologists with over 1 year experience in this hospital to use while taking the x-rays and the degree of satisfaction was surveyed and it was examined if the increase of the degree of satisfaction had an effect on the reduction in the examination time. The patients who utilized the examination information printout revealed results of approximately a 7.8% higher degree of satisfaction among the patients who had previous experience receiving x-ray examinations compared to those were having an x-ray for the first time. In the age groups between 30 to 70 years of age, the age group in the 30's revealed the lowest level of satisfaction at approximately 69% and the group in the 50's showed the highest degree of satisfaction of 87.94%. In the survey of the Radiologic Technologists, 85% responded that they were satisfied. In the question that stated "Will the examination information printouts reduce the time involved in unnecessary conversations with the patients?," the responses showed a 95% degree of satisfaction. The degree of satisfaction was high over the examination information printout by both the patients and the Radiologic Technologists. Although the effects of examination time reduction varied based on the ages of the patients and physical conditions that they were in and could not be given measurement values, it was able to be seen through the survey that reduction of the unnecessary communication between the patient and the Radiologic Technologists contributed to the increase in the degree of satisfaction. As a result, both the patients and the Radiologic Technologists had an increased degree of satisfaction over the examination information printout and it was possible for improvements to be made in the quality of medical service provided as well. Nevertheless, it is considered that a more developed manual in terms of quality and quantity must be produced using a more systematic approach and design.

  • PDF

Evaluation of Respiration Reproducibility of Chest General X-ray Examination using Self-made Respiratory Synchronization Device (자체 제작한 호흡 동기화 장치를 통한 흉부 일반촬영 검사의 호흡 재현성 평가)

  • Kwon, Oh-Young;Lee, Chang-Hun;Yong, Keum-Ju;Jin, Seon-Hui;Jung, Da-Bin;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1049-1056
    • /
    • 2021
  • The purpose of this study was to develop a respiratory synchronization device for X-ray (X-RSD) to increase the reproducibility of inspiration when examining the Chest X-ray of a patient who difficulty in breathing coordination. The X-RSD was self-made using an air pressure sensor and air was injected by connecting a ventilator to the mannequin for CPR. At this time, the amount of injected air was quantified using the SkillReporting device. After placing the X-RSD on the chest of the mannequin, the amount of air was tested in 6 steps from 200 to 700 cc by 100 cc increased. For the accuracy evaluation, the sensitivity of X-RSD was measured by repeating a total of 80 measurements, and the sensitivity was 100%, and very precise results were obtained. After that, the images examined while viewing the X-RSD of the chest lateral examination and the images obtained by the blind examination were compared and evaluated. The lung volume of X-RSD was larger than that of the blind test, and the deviation was smaller. Overall, the use of X-RSD can help with chest X-ray examination of patients who have difficulty in cooperating, and it is thought that it will be possible to contribute to the reduction of exposure dose by reducing the repeat rate of general X-ray examinations.

Survey on the Incidence of Homeless Pulmonary Tuberculosis Infection Rate through Chest X-ray Examination (흉부 X-선 검사를 통한 노숙인 폐결핵 감염률 현황조사)

  • Kim, Mi-Young;Shin, Sung-Rae;Ryu, Young-Hwan;Lim, Hwan-Yeal
    • Journal of Radiation Industry
    • /
    • v.10 no.4
    • /
    • pp.249-255
    • /
    • 2016
  • This study, Seoul City shelter, you are trying to seek medical cooperation and cure rate increase proposal Yu findings's current situation and tuberculosis of homeless tuberculosis. Inspector, and has a total 591 people is targeted to implement an interview after acquiring utilization agreement in studies conducted chest X-ray photography. Of the interview questions, three or more protons, it is determined that the TB symptomatic conducted sputum examination, chest X-ray examination confirms the physician radiology, when sputum examination primarily chromatic findings the double implemented and conducted by requesting the ship inspection also said inspection sputum acid-fast bacteria if it is true one, respectively. confirmed case result of checking whether there is a difference due to risk factors(Jb) at the chi square black, it was found that there is no statistically significant difference at 95% confidence level. (${\chi}^2=0.276$, p>0.05), suspected case (Ac, Ae) results of examining whether there is a difference due to risk factors in chi square black, that there is a statistically significant difference at 99% confidence level is I found (${\chi}^2=9.414$, p<0.01). The nature of the homeless tuberculosis screening and directed to the distance homeless specific location are likely to evaluate the actual incidence low and aggressive or management needs, the rationale is allowed insufficient reality is. Through this research, future, for tuberculosis high risk tuberculosis patient, such as homeless to expand the tuberculosis screening of infectious tuberculosis patients in private medical institutions, and one-stop service that chest X-ray examination and sputum examination is carried out at the same time introduced immediately to prevent the inspection and examination, cure, and should establish a foundation that can be up to post administration.

Effect of Field Size on the Clinical Exposure Index for Lumbar Spine X-ray Examination (노출지수를 이용한 요추 X선 촬영의 조사야 유효성 평가)

  • Park, Hyemin;Yoon, Yongsu;Kim, Jungsu;Jeong, Hoiwoun
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.183-187
    • /
    • 2021
  • The field size of the lumbar spine X-ray examination, which belongs to the most frequent examination in general radiography, is 5 times wider than the width of the lumbar spine. Exposure index (EI) as per International Electrotechnical Commission has a proportional relationship with the dose incident on the image receptor for clinical protocols in addition to RQA5, which is a calibration beam quality. In this study, the effectiveness of the set field size was evaluated through the change of EI according to the size of field during lumbar spine X-ray examinations. Lumbar anterior-posterior and lateral examinations was performed using a whole-body phantom, and the national average exposure conditions of Korea investigated in 2017 were introduced for the X-ray exposure. As a result of comparing the EI displayed on the console of digital radiography system for the three field size in ① 18 × 36 cm2 ② 25 × 36 cm2 ③ 36 × 36 cm2, the EI values showed a tendency to increase as the field size increased. Since the patient dose, such as organ dose around the lumbar spine, increases as the field size becomes larger, thus, if the EI obtained from the field size at a level that does not interfere with diagnosis is set as a reference, the effectiveness of the field size can be evaluated through the EI displayed on the console when the lumbar spine X-ray examination is conducted.

Study of Suitable Angle of Tibia-Foot and X-ray Tube for Navicular in Foot X-ray Examination (족부 X선 검사에서 주상골 관찰에 용이한 Tibia-Foot angle과 X-ray tube 각도에 대한 연구)

  • Moon, Joo-Wan;Han, Jae-Bok;Choi, Nam-Gil
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.39-46
    • /
    • 2018
  • The purpose of this study was to determine suitable angle of Tibia-foot and the X-ray tube for scaphoid in foot X-ray examination. A total of twenty patients(mean age $32.12{\pm}years)$ are participated in this study. In the positions of Foot AP, internal and external oblique, tibia-foot angle was defined as $90^{\circ}$ and $135^{\circ}$, and x-ray tube angle was defined as $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$ and $20^{\circ}$ respectively. The image quality was evaluated with blind test yielding scores ranging from 0 to 5 by the evaluation team consisted of 2 radiogical technologists, 2 radiologists, and 2 orthopedic surgeons. In case of Foot AP position, the degree of overlap between cuneiform and navicular was 3% and the blind test result was 4.89 at tibia-foot angle of $90^{\circ}$ and $15^{\circ}$ X-ray tube angle. When the tibia-foot angle is $135^{\circ}$, the degree of overlap was 5%, also the blind test result was 4.30 at $15^{\circ}$ X-ray tube angle. The degree of overlap and blind test result were 30% and 3.75 respectively at $0^{\circ}$ X-ray tube angle. In case of internal oblique position, at tibia-foot angle of $90^{\circ}$ and $0^{\circ}$ X-ray tube angle, the degree of overlap was 4% and the blind test result was 4.70. The 5% overlapping and highest score as 4.55 were obtained on tibia-foot angle of $135^{\circ}$ and $0^{\circ}$ X-ray tube angle. In case of external oblique position, at tibia-foot angle of $90^{\circ}$ and $15^{\circ}$ X-ray tube angle, the degree of overlap was 4% and the blind test score was 4.85. The 5% overlapping and highest score as 4.75 were obtained on tibia-foot angle of $135^{\circ}$ and $15^{\circ}$ X-ray tube angle. In conclusion, we confirmed suitable angle of tibia-foot and X-ray tube for scaph46oid in foot X-ray examination in this study. These findings will be helpful for us to reading for navicular fracture.

Analysis of the Influence of Examination Gowns on the Image and the Suitable Fabrics for Chest AP Examinations on DR X-ray Systems (디지털 X-선 시스템에서 흉부 전·후 방향 검사 시 검사복이 영상에 미치는 영향과 적정 검사복 원단의 분석)

  • Eun-Bi Baek;Yoo-Jin Jeong;Su-Bin Lim;Sang-Jo Park;Yeong-Cheol Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.865-872
    • /
    • 2023
  • The purpose of this study was to analyze fabrics suitable for use as examination gowns to determine whether examination gowns affect imaging during anterior to posterior chest examinations(Chest AP) on a digital X-ray system. Examination gowns in use at five medical centers in Seoul were collected and included modal, tencel, cotton, and rayon fabrics. The selection of fabrics was based on studies that reported fabrics with good tactile, absorbent, stretchable, and wrinkle resistance. Phantoms of five hospital gowns and four fabrics, arranged in overlapping layers from one to eight, were created and examined on a digital X-ray system in both Chest AP examination. The images examined were subjected to a first-step profile analysis, a second-step signal intensity averaging analysis, and a third-step microscopic analysis. The results showed that all nine materials had an increasing impact on the image as the number of layers of fabric increased, with the modal fabric having the least impact on the image in the first, second, and third analyses. In conclusion, as the resolution of digital x-ray systems increases, the impact of examination clothing on the image will increase, and research to find suitable materials for examination clothing will continue to be necessary.

Development of Acanthial Parieto Projection for Maxillary Diagnosis in X-ray Paranasal Sinuses (X-ray 코곁굴 검사에서 위턱굴 진단을 위한 비극-두정방향 촬영법 개발)

  • Byung-Ju Ahn;Yong-Wan Kim;In-Soo Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.327-333
    • /
    • 2023
  • In Order to Diagnose Maxillary Bone and Maxillary Sinus in the X-Ray Paranasal Sinus Projection test, this Study used Skull Rando Phantom to Change the Posture and X-ray tube Angle to 5° of the Head or 5° of ROC Who worked for more than 10 years. The Significance of the Evaluated score was Verified through SPSS Ver. 3.0, and the Cronbach value was Significantly higher at 0.712. In addition, as a Result of Calculating SNR by Setting the ROI(Receiver Operation Characteristic) of the Maxillary bone and Maxillary sinus images, it was the Highest at 6,449 in the Examination by tilting 5° toward the Head or Leg of the X-ray tube. In the study, it is believed that among the X-Ray simple Paranasal Sinus projection tests, a sharp Image can be Obtained during the Examination by Tilting the X-ray tube 5° toward the Head or Leg.

Application of 3-Dimensional MOIRE Topography to the School Screening Program for Adolescent Scoliosis (모아레 체형측정법이 청소년기 척추측만증의 조기집단검진 활용 가능성에 대한 평가)

  • Han, Myeng-Gum;Shin, Byung-Cheul
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.4 no.1
    • /
    • pp.1-16
    • /
    • 2003
  • Objectives : The purpose of this study is researching for possibility that Moire topography be applied in group school screening for scoliosis known school health problem, and find acceptable method of early detection and early treatment for scoliosis Methods : The authors practiced Moire topography for primary & middle school 1,895 students[male 976, female 919] in Jeonju, korea in 2001. After we distinguished students who had abnormal finding in Moire topography and then re-examined spinal X-ray analysis. The data was analysed and evaluated statistically Results : According to this research, the abnormal finding in Moire topography was 53.7% (1,018 students), and students needed X-ray re-examination were 11.2% (213 students). Students diagnosed scoliosis by X-ray re-examination were 1.8%. According to statistical analysis, interval between vertical base line of pelvis and vertical base line of neck, gap between left distance and right distance to the vertical base line of pelvis and difference of contour lines have strong correlations with deformity degree of the body surface examined by Moire. Conclusions : Following this research, throughout early detection for scoliosis by Moire topography could reduce exposure from scoliosis radiographs, and could detect trunk asymmetry that couldn't be found existing X-ray examination, so it made selecting students under observation who have bad posture possible.

  • PDF

A Study of Radiation Dose Evaluation and Optimization Methods for Intra Oral Dental X-ray in Pediatric Patient (소아 구내촬영 시 방사선량 평가 및 최적화 방안에 대한 연구)

  • Lee, Hyun-Yong;Cho, Yong-In
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.195-203
    • /
    • 2021
  • Although intra oral dental x-ray is a lower dose than other radiological examinations, pediatric patients are known to have a higher risk of radiation damage than adults. For this reason, pediatric dental x-ray requires management of dose evaluation and imaging conditions during the examination. In this study, the dose calculation program ALARA-Dental(child/adult) was used to evaluate the organ dose and effective dose exposed to each examination site during intra oral imaging of children during dental radiographic examination, and dose analysis according to the imaging conditions was performed. As a result, the highest organ dose distribution was shown at 0.044 ~ 0.097 mGy in all are as of the mucous membrane of oral cavity except for the maxillary incisors and canines. Also, in the case of the thyroid gland, the maxillary canine and maxillary premolar examination showed 0.027 and 0.020 mGy, respectively, and the dose distribution was 15.4% to 70.0% higher than that of the mandibular examination. As for the effective dose calculated during intra oral imaging, the maxillary anterior and canine examinations showed the highest effective doses of 0.005 and 0.004 mSv, respectively, and the maxillary area examination showed a higher dose distribution on average than the mandible.

Error Analysis of General X-ray Examination by Using Simulation Training (시뮬레이션 교육을 통한 일반 X선 검사의 오류 분석)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.919-927
    • /
    • 2018
  • The purpose of this study was to present simulation training model for general X-ray examinations and to analyze the errors that occur during the simulation training. From 2012 to 2018, a total of 183 students (77 men and 106 women) participated. The simulated X-ray system used computed radiography (CR) system. The contents of simulation training were patient's care, X-ray examinations accuracy, images stability, etc. As a result, it were found that the patient's position setting error, the accuracy error of the X-ray beam central ray, the image receptor's size and setting error, the error of the grid use, the marking error, and the error of X-ray exposure technical factors. It is expected that improved practical general X-ray examinations training of radiographer will be needed, focusing on these errors, so that we could contribute to the health care of the people by providing precise examinations and high quality medical service.