• 제목/요약/키워드: X-ray 시스템

검색결과 499건 처리시간 0.026초

X선 영상 기반 치아와동 컴퓨터 보조검출 시스템에서의 동적윤곽 알고리즘 비교 (A Comparison of Active Contour Algorithms in Computer-aided Detection System for Dental Cavity using X-ray Image)

  • 김대한;허창회;조현종
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1678-1684
    • /
    • 2018
  • Dental caries is one of the most popular oral disease. The aim of automatic dental cavity detection system is helping dentist to make accurate diagnosis. It is very important to separate cavity from the teeth in the detection system. In this paper, We compared two active contour algorithms, Snake and DRLSE(Distance Regularized Level Set Evolution). To improve performance, image is selected ROI(region of interest), then applied bilateral filter, Canny edge. In order to evaluate the algorithms, we applied to 7 tooth phantoms from incisor to molar. Each teeth contains two cavities of different shape. As a result, Snake is faster than DRLSE, but Snake has limitation to compute topology of objects. DRLSE is slower but those of performance is better.

졸겔 법을 통한 라우르산 기반의 상변화 물질의 합성 (Synthesis of Lauric Acid Based Phase Change Materials Via Sol-gel Route)

  • 샤픽빈이신크;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.42-43
    • /
    • 2020
  • Lauric acid (LA) which is also known as dodecanoic acid has been selected as the phase change material (PCM) owing to eco-friendly in nature. A systematic study has been conducted for encapsulation of LA (core) with silicon dioxide (SiO2) as shell material. Different core-shell ratio was chosen to microencapsulate the LA with 10 ml of tetraethyl orthosilicate (TEOS) as the precursor solution for the formation of SiO2. The synthesis of microencapsulated LA was carried out at 2.5 pH of precursor solution. The synthesized microencapsulated LA are characterized by Fourier transform infrared spectroscope (FT-IR) and X-Ray Diffraction (XRD) which confirmed the presence of SiO2 shell on the surface of LA.

  • PDF

Sol-gel 공정을 통한 SiO2 쉘과의 상이한 스테아산 비율의 합성 및 특성 (Synthesis and Characteristics of Different Ratio of Stearic Acid with SiO2 Shell Through Sol-Gel Process)

  • 샤픽빈이신크;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.66-67
    • /
    • 2020
  • The synthesis of stearic acid composite phase change material (PCM) was investigated and the samples produced were characterized for use in latent heat storage, using a simple chemical sol-gel process. The PCM was encapsulated to tetraethyl orthosilicate by various preparation ratios of stearic acid (5, 10, 15, 20, 30 and 50%). Fourier transformation infrared spectroscope (FT-IR) and X-Ray diffraction (XRD) were performed to determine the chemical structure and crystalloid phase of the microencapsulated PCM. SATEOS1 (5%) shows the best proportion for the PCM. With the presence of stearic acid as core materials and SiO2 as the supporting materials, it does not show any chemical reaction between both of them. SATEOS1 shows promising potential for thermal energy storage as it shows a better encapsulation efficiency and good thermal stability.

  • PDF

Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구 (Consideration of density matching technique of the plate type direct radiologic image system and the conventional X-ray film;first step for the subtraction)

  • 소성수;노현수;김창성;최성호;김기덕;조규성
    • Journal of Periodontal and Implant Science
    • /
    • 제32권1호
    • /
    • pp.199-211
    • /
    • 2002
  • Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9463 to 0.9925, and the standard radiographic system had the tendency to show higher R-square in shorter focal distances.

노후 특수·화물 차량 PM/NOx 저감을 위한 SDPF 촉매 및 코팅 기술 연구 (A Study on Selective Catalytic Reduction on Diesel Particulate Filter Catalyst and Coating Technology the Removal of Particulate Matters and NOx for Old Special Cargo Vehicles)

  • 정관형;서필원;오형석;김종국;강소연;강정호;김현준;신병선
    • 공업화학
    • /
    • 제32권6호
    • /
    • pp.695-699
    • /
    • 2021
  • 본 연구에서는, 노후된 엔진을 사용하는 트럭 및 특수차량에서 배출되는 NOx 및 PM을 동시에 제거하기 위해 SDPF 후처리 시스템 연구를 수행하였다. 우선, SDPF의 SCR 촉매를 선정하기 위해서, V/TiO2와 Cu-zeolite 촉매의 de-NOx 성능을 비교하였으며, SCR 촉매특성분석은 BET, XRD 및 NH3-TPD를 통해 분석하였다. 촉매 활성시험 결과, Cu-zeolite 촉매가 가장 우수한 내열성을 보여주었다. 최적의 SDPF 코팅을 위해서, 목표로 설정된 입자 크기에 맞추어 슬러리를 제조하였다. SCR 코팅량에 따른 SDPF의 코팅안정성과 배압 결과, SDPF 촉매를 로딩량별로 A, B, C 샘플을 제작하여 코팅안정성과 배압 및 de-NOx 성능을 비교한 결과 B 샘플에서에서 가장 우수한 결과를 보였다. 최적 SDPF 후처리시스템에 대해 엔진동력계 시험을 실시하였으며, 시험결과 Eu-5 규제를 만족하였다.

통합적 광추적 모델에 의한 해양탑재체 GOCI의 궤도 상 광학 성능 검증 (Integrated Ray Tracing Model for In-Orbit Optical Performance Simulation for GOCI)

  • 함선정;이재민;김성희;윤형식;강금실;명환춘;김석환
    • 한국위성정보통신학회논문지
    • /
    • 제1권2호
    • /
    • pp.1-7
    • /
    • 2006
  • 현재 항공우주연구원은 2008년에 발사 운용 예정인 통신-해양-기상위성의 주요 탑재체들 중의 하나로 한반도 주변 해역의 환경 상태를 정밀 측정하려는 정지궤도 해색센서(GOCI)를 개발하고 있다. 본 논문에서는 해색센서의 궤도상 임무성능 검증을 원할이 수행하기 위해 통합적 광선 추적 기법을 이용한 임무성능 검증 수치모사 모델을 개발 제시한다. 수치모사 모델 내에서 태양은 지구 방향으로 복사에너지를 방사하는 구형 광원으로 입력되었고, 구면인 지구 표면 중 한반도를 중심으로 한 2500km x 2500km 넓이의 곡면 관측 영역은 지표와 해수면으로 구분하여 서로 다른 특성의 람버트 산란 면들로 정의되었다. 수치모사 모델 내에서 해색센서 광학시스템은 태양을 출발하여, 지표 및 해수면의 환경적 특성 변화를 반영하는 반사도의 변화에 따라 산란 후 입사되어오는 광선들의 경로를 추적하여 초점면 광소자에 맺히게 하여준다. 이러한 통합적 광선 추적 기법을 이용하여 개발 중인 해색센서가 궤도상에서 한반도 동남부 연해 상에서 가상적으로 발생된 반사율 감소 0.014에 해당하는 적조현상을 탐지해낼 수 있음을 수치모사 입증하였다. 이 같은 결과는 본 논문에 기술된 통합적 광선 추적 기법을 이용한 과학임무 성능 검증 수치모사 모형은 해색센서 뿐만 아니라, 다른 과학적 측정 목적의 위성 탑재체의 임무성능 검증에도 활용 할 수 있는 기반 기술을 확립하였다는 의의를 제공한다.

  • PDF

우주 발사체 구조 요소의 비파피검사 (Nondestructive Inspection of Launch Vehicle Structural Components)

  • 공철원;윤종훈;박재성;은세원;장영순;이영무
    • 비파괴검사학회지
    • /
    • 제29권4호
    • /
    • pp.331-337
    • /
    • 2009
  • 우주 발사체는 매우 높은 신뢰도의 경량구조가 필요하다. 비 파괴검사 방법 등을 이용한 구조 건전성 관리가 중요하다. 본 논문에서는 우주발사체의 제작 및 검사에 실제 사용되었던 비 파괴검사 사례 중 일부를 정리하였다. 검사 방법으로는 초음파, X-ray, tapping, 음향방출 등이 사용되었고, 하드웨어로는 페이로드 페어링, 고압탱크, 체결부 및 접합부 등을 대상으로 하였다. 페이로드 페어링에서는 샌드위치 미접착 검사의 정량적 기준을 제시하였고, 고압탱크는 내압 인증시험시 내압증가에 따른 음향방출 데이터를 정리하였다. 샌드위치 체결부에서는 음향방출 신호의 주파수 변화에 따른 파손모드를 분석하였고, 이종재료 접합 구조에서는 미접착부 초음파검사를 위한 표준시편을 제시하였다. 이러한 분석 및 기록은 발사체 시스템을 구성하여 어떠한 상황이 발생하여도 신속하게 판단할 수 있는 근거가 될 수 있으며 발사체 시스템의 신뢰도를 높여주는 역할을 한다.

충전 시스템과 가교 시스템이 금속염 형성에 의한 EPDM 복합체의 백화에 미치는 영향 (Influence of Filler and Cure Systems on Whitening of EPDM Composites by Formation of Metal Salt)

  • 정혜승;최성신
    • Elastomers and Composites
    • /
    • 제47권3호
    • /
    • pp.210-215
    • /
    • 2012
  • 무기첨가제의 조성이 다른 EPDM 복합체를 준비하여 $90^{\circ}C$ 공기와 수돗물에서 각각 7일간 노화시켜 백화현상을 관찰하였다. 공기 중에서 노화시킨 시험편들은 모두 백화가 발생하지 않았으나, 수돗물에서 노화시킨 시험편들 중 스테아린산이 함유된 시험편들은 백화가 심하게 발생하였다. 무기첨가제의 조성에 따른 백화 현상의 차이는 없었다. 백화 물질을 가스 크로마토그래피/질량분석법(GC/MS), 영상 분석(image analysis), 에너지 분산 X-선 분광법(EDX), 감쇠 전반사-후리에 변환 적외선 분광법(ATR-FTIR)을 이용하여 분석하였다. 백화 물질은 스테아린산의 금속염이라는 것을 확인하였다. 스테아린산의 금속염은 수돗물에 존재하는 금속 이온과 시험편 내에 존재하는 스테아린산과의 반응에 의해 형성된다.

디지털방사선영상에서 산란선의 영상특성 평가 (Evaluation of Image Quality for Scattered X-rays using in Digital Radiography)

  • 김한솔;김창수
    • 한국방사선학회논문지
    • /
    • 제16권4호
    • /
    • pp.395-403
    • /
    • 2022
  • 본 연구에서는 디지털방사선영상 시스템에 사용되는 평판형 검출기(flat-panel detector, FPD)를 이용하여 조직 등가 물질인 폴리메틸메타아크릴레이트(Polymethyl Methacrylate, PMMA)의 두께 변화에 따라 발생되는 산란선이 영상품질의 영향으로서 해상력 평가의 변조전달함수(modulation-transfer function, MTF)와 잡음력 스펙트럼(noise-power spectrum, NPS)으로 정량적인 영상 평가를 위한 연구를 수행하였다. 해상력-차트 팬텀 영상으로 PMMA 두께가 증가할수록 산란선의 영향이 커져 변조특성이 저하 되는 것을 알 수 있고 영상이 밝다. 결과는 영상의 잡음이 많아진다는 것을 알 수 있는데 공간주파수 별로 확인하기 위해 푸리에 변환으로 잡음력 스펙트럼 영상을 얻었다. 그러므로 영상에서 피사체로서 PMMA 두께 증가에 따라 산란선의 변화를 MTF로 평가하여 해상도 특성변화와 2차원 잡음력 스펙트럼을 1차원 값으로 나타낸 결과를 통해 PMMA 두께와 잡음은 비례하는 것을 확인할 수 있다.

PDA기반 의료영상의 전송시스템 구현 (Implementation of PACS using PDA System on Medical Images)

  • 지연상;동경래;김창복
    • 한국콘텐츠학회논문지
    • /
    • 제9권4호
    • /
    • pp.247-253
    • /
    • 2009
  • PACS(Picture archiving communication system)란 의료영상정보를 디지털 영상으로 획득, 저장하여 외래나 병동에서 언제든지 검색 및 조회가 가능한 시스템을 의미 하지만 휴일과 야간에는 의료영상정보에 대한 접근이 공간적으로 제한되어 있어서 환자의 검사결과에 대한 정보를 조회 할 수 없는 문제점이 있다. 이에 대한 해결 방안은 무선 LAN과 CDMA 전화기가 내장된 PDA를 이용하여 판독의사나 수술의사 등이 원외에서도 의료영상정보에 접근하여 환자의 처치 등에 관하여 원격으로 처방 할 수 있는 서비스 방식이 유용하다. 이런 방식은 PDA와 무선랜의 하드웨어적 특성상 JPEG 파일 형태로 서비스 할 수밖에 없는데 10:1 압축 방식에서 진단가치를 잃지 않으면서도 최대의 효과를 낼 수 있었다. 또한 추후 네트워크 속도와 하드웨어적 사양이 개선된다면 DICOM 무손실 이미지의 조회도 구현 가능함을 알 수 있었다.