• 제목/요약/키워드: X-ray 시스템

검색결과 500건 처리시간 0.026초

하이브리드 코팅 시스템으로 제조된 초고경도 Ti-Si-C-N 코팅막의 기계적 특성 평가 (Mechanical evaluation of superhard Ti-Si-C-N coatings prepared by a hybrid coating system)

  • 강신후;강명창;김광호
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.178-181
    • /
    • 2005
  • Quaternary Ti-Si-C-N coatings were deposited on WC-Co substrates by a hybrid coating system of arc ion plating (AIP) and sputtering techniques using Ti and Si targets, in an $Ar/N_2/CH_4$ gaseous mixture. The crystallinity, bending status, and microstructure of the Ti-Si-C-N coatings were measured by X-ray diffractometer (XRD) and X-ray photoelectron spectroscope (XPS), The micro-hardness of Ti(C,N) and Ti-Si-N coatings were about 30 and 40 GPa, respectively. As the Si was incorporated into Ti(C,N) coatings, the Ti-Si-C-N coatings having Si content of $8.9\;at.\%$ showed the maximum hardness value of about 55 GPa. In this work, the microstructure and mechanical properties of Ti-Si-C-N coatings were systematically investigated.

  • PDF

6mm$^{t}$ 조선용 Primer코팅강판의 $CO_2$레이저 용접성 (III) - X-선 투과영상시스템에 의한 결함형성거동의 리얼타임관찰 - (The Weldability of 6mm$^{t}$ Primer-coated Steel for Shipbuilding Using $CO_2$ Laser (III) - Real-time X-ray Imaging Observation of Defect Formation of Laser Welding -)

  • 김종도;박현준;이종봉;김영식
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2004년도 춘계 학술발표대회 개요집
    • /
    • pp.103-105
    • /
    • 2004
  • 키홀 용접현상에 관한 연구는, 키홀 현상이 용융금속내부에서 아주 빠른 속도로 과도적으로 이루어지기 때문에 그 계측과 해석이 곤란하여 수 많은 가정이나 가설 하에서 용입형상과 키홀의 거동에 관한 해석이 국한된 영역에서 이루어지고 있는 것이 현실이다. (중략)

  • PDF

의료 영상 처리를 위한 실시간 영상 처리 시스템의 개발 (The development of an image processing system for processing medical image)

  • 유경걸;홍민석;이세현;박상희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.718-721
    • /
    • 1988
  • In this paper, we develop 256*256*8 bit real-time image digitizer with the IBM-PC as a image processor. With this developed system, we process a chest X-ray image, which is a medical image, using the adaptive algorithm. In the future, we consider that the application of this developed system is extended in the various fields.

  • PDF

CIGS 태양전지용 Cd-Free 버퍼층 제조 (Preparation of Cadmium-free Buffer Layers for CIGS Solar Cells)

  • 문지현;김지현;유인상;박상준
    • 공업화학
    • /
    • 제25권6호
    • /
    • pp.577-580
    • /
    • 2014
  • CIGS 태양 전지용 cadmium (Cd)-free $In(OH)_xS_y$ 버퍼층을 화학적 용액성장법을 이용해서 형성시켰고 최적 반응시간을 파악하였다. 투과율 측정과 함께 이온집적빔 시스템으로 직접 박막을 관찰해서 박막성장 조건을 최적화 하였으며 X선 회절분석법과 X선 광전자 분광법, 주사현미경을 이용해서 박막의 특성을 파악하였다. 그 결과 $In(OH)_xS_y$ 버퍼층의 증착을 위한 최적 반응 시간은 온도 섭씨 $70^{\circ}$의 조건에서 20 min임을 확인하였으며, 이때의 버퍼층의 두께는 57 nm 가량이었고 밴드갭 에너지는 2.7 eV를 나타내었다. 아울러 molybdenum (Mo)층과 CIGS층 위에서 $In(OH)_xS_y$ 버퍼층을 형성시키는 경우에 XPS 피크의 차이는 볼 수 없었다.

연합학습의 의료분야 적용을 위한 자기지도 메타러닝 (Self-supervised Meta-learning for the Application of Federated Learning on the Medical Domain)

  • 공희산;김광수
    • 지능정보연구
    • /
    • 제28권4호
    • /
    • pp.27-40
    • /
    • 2022
  • 최근 많은 발전을 이룬 의료 인공지능은 의사가 진단과 결정을 내리는 데 도움을 주는 등 중요한 역할을 수행하고 있다. 특히, 흉부 엑스레이 분야는 접근성 및 흉부질환 탐지에 유용함과 최근 COVID-19 상황이 도래함에 따라 많은 관심을 받고 있다. 그러나, 데이터의 수가 많음에도 레이블이 있는 데이터의 수가 부족하므로 효과적인 인공지능 모델을 만드는데 한계가 있다. 이러한 문제를 완화하는 방안으로 연합학습을 흉부 엑스레이 데이터에 적용한 연구가 등장했지만, 여전히 다음과 같은 문제를 내포하고 있다. 1) Non-IID 환경에서 발생할 수 있는 문제를 고려하지 않았다. 2) 연합학습 환경에서도 여전히 클라이언트의 레이블이 있는 데이터가 부족하다. 우리는 자기지도학습 모델을 연합학습의 Global 모델로 사용함으로써 위와 같은 문제를 해결하는 방법을 제안한다. 이를 위해 흉부 엑스레이 데이터를 사용한 연합학습에 알맞은 자기지도학습 방법론을 실험적으로 탐색하며, 자기지도학습 모델을 연합학습에 사용함으로써 얻을 수 있는 장점을 검증한다.

Yarn Segmentation from 3-D Voxel Data for Analysis of Textile Fabric Structure

  • Shinohara, Toshihiro;Takayama, Jun-ya;Ohyama, Shinji;Kobayashi, Akira
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.877-881
    • /
    • 2005
  • In this paper, a novel method for analyzing a textile fabric structure is proposed to segment each yarn of the textile fabric from voxel data made out of its X-ray computed tomography (CT) images. In order to segment the each yarn, directions of fibers, of which yarn consists, are firstly estimated by correlating the voxel with a fiber model. Second, each fiber is reconstructed by clustering the voxel of the fiber using the estimated fiber direction as a similarity. Then, each yarn is reconstructed by clustering the reconstructed fibers using a distance which is newly defined as a dissimilarity. Consequently, each yarn of the textile fabric is segmented from the voxel data. The effectiveness of the proposed method is confirmed by experimentally applying the method to voxel data of a sample plain woven fabric, which is made of polyester two folded yarn. The each two folded yarn is correctly segmented by the proposed method.

  • PDF

PECVD 공정에 의해 증착된 비정질 실리콘 박막의 특성에 관한 연구

  • 이용수;성호근
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.223.2-223.2
    • /
    • 2013
  • 비정질 실리콘은 태양전지, 트랜지스터, 이미지 센서 등 다양한 분야에서 응용되고 있으며 새로운 박막 소자 개발을 위한 소재로서 많은 연구가 진행되고 있다. 하지만 소자개발에 있어 공정상에서 발생하는 비정질 실리콘 박막의 높은 응력(stress)은 소자의 특성을 떨어뜨리는 문제점을 갖는다. 따라서 우수한 특성의 소자 개발을 위해서는 보다 낮은 응력을 갖는 비정질 실리콘 박막 증착 및 공정 조건에 따른 응력 조절이 필요하다. 저응력의 비정질 실리콘 박막 증착은 보다 낮은 반응온도에서 증착속도를 최소로 하여 성장되어야 하는데 이는 플라즈마기상증착(Plasma enhanced chemical vapor deposition, PECVD) 시스템에 의해 가능하다. 따라서 본 연구에서는 PECVD 시스템을 사용하여 비정질 실리콘 박막을 증착하였고 그 특성을 분석하였다. 이 때 증착 온도, rf 파워, 공정 압력은 실험결과로부터 얻어진 낮은 박막 증착속도 하에서 안정적으로 증착이 가능한 조건으로 일정하게 유지하여 실험하였다. 공정 가스는 SiH4/He/N2의 혼합가스를 사용하였고 응력 조절을 위해 SiH4/He 가스비를 일정한 비율로 변화하여 비정질 실리콘 박막을 증착하였다. 증착된 박막의 두께 및 표면 특성은 field emission scanning electron microscopy 및 atomic force microscopy를 이용하여 분석하였고, energy dispersive X-ray 분석을 통하여 정량 및 정성적 분석을 수행하였다. 그리고 stress measurement system을 이용하여 박막의 응력을 측정하였고 X-ray diffraction 측정 및 ellipsometry 측정으로부터 증착된 박막의 결정성, 굴절률 및 oiptical bandgap을 분석하였다.

  • PDF

디지탈 X-선 촬영시스템의 영상 및 물리적 특성 분석 (Characterization of Imaging and Physical Properties in Digital Radiography System)

  • 김종효;이태수;박광석;한만청;이충웅;민병구
    • 대한전자공학회논문지
    • /
    • 제26권7호
    • /
    • pp.112-124
    • /
    • 1989
  • 최근 본 연구팀에서 기존의 선 조사방식 디지탈 X-선 촬영시스템의 단점을 보완하여 촬영시간을 0.7초로 단축시키고 환자에의 X-선 조사량을 3mR 정도로 감소시킨 디지탈 X-선 촬영시스템을 개발한 바, 이 논문에서는 이 시스템의 감도 특성, 산란 성분 구성률, 양자검출 효율, 변조전달함수, 그리고 콘트라스트 상세도 등과 같은 물리적 및 영상특성들을 조사함으로써 그 촬영성능을 평가하였다. 조사 결과 이 시스템의 감도특성은 입사에너지에 비례하며, 기존의 필름-스크린 보다 적은 X-선 조사량으로도 더 우수한 콘트라스트 해상도를 지녔음이 나타났다. 그 이유는 뛰어난 산란선 제거능력과 양자검출 효율 때문인 것으로 생각된다.

  • PDF

단열배관의 온라인 두께측정시스템 개발 (Development of Real Time On-Line Thickness Measuring System for Insulated Pipeline)

  • 장지훈;김병주;조경식;김기동
    • 연구논문집
    • /
    • 통권32호
    • /
    • pp.65-76
    • /
    • 2002
  • The intensity of x-ray or gamma-ray is attenuated according to density and thickness of the transmitted medium. In this study, by using this principle, on-line real-time radiometric system was developed using a 128 channels linear array of solid state detectors to measure wall thickness of insulated piping system. This system uses a Ir-192 as a gamma ray source and detector is composed of BGO scintillator and photodiode. Ir-192 gamma ray source and linear detector array mounted on a computer controlled robotic crawler. The Ir-192 gamma ray source is located on one side of the piping components and the detector array on the other side. The individual detectors of the detector array measure the intensity of the gamma rays after passing through the walls and the insulation of the piping component under measurement. The output of the detector array is amplified by amplifier and transmitted to the computer. This system collects and analyses the data from the detector array in real-time. The maximum measurable length of pipe is 120cm/mm. in the case of 1mm scanning interval.

  • PDF