• Title/Summary/Keyword: X-ray 시스템

Search Result 500, Processing Time 0.028 seconds

A Comparison of Active Contour Algorithms in Computer-aided Detection System for Dental Cavity using X-ray Image (X선 영상 기반 치아와동 컴퓨터 보조검출 시스템에서의 동적윤곽 알고리즘 비교)

  • Kim, Dae-han;Heo, Chang-hoe;Cho, Hyun-chong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1678-1684
    • /
    • 2018
  • Dental caries is one of the most popular oral disease. The aim of automatic dental cavity detection system is helping dentist to make accurate diagnosis. It is very important to separate cavity from the teeth in the detection system. In this paper, We compared two active contour algorithms, Snake and DRLSE(Distance Regularized Level Set Evolution). To improve performance, image is selected ROI(region of interest), then applied bilateral filter, Canny edge. In order to evaluate the algorithms, we applied to 7 tooth phantoms from incisor to molar. Each teeth contains two cavities of different shape. As a result, Snake is faster than DRLSE, but Snake has limitation to compute topology of objects. DRLSE is slower but those of performance is better.

Synthesis of Lauric Acid Based Phase Change Materials Via Sol-gel Route (졸겔 법을 통한 라우르산 기반의 상변화 물질의 합성)

  • Ishak, Shafiq;Lee, Han Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.42-43
    • /
    • 2020
  • Lauric acid (LA) which is also known as dodecanoic acid has been selected as the phase change material (PCM) owing to eco-friendly in nature. A systematic study has been conducted for encapsulation of LA (core) with silicon dioxide (SiO2) as shell material. Different core-shell ratio was chosen to microencapsulate the LA with 10 ml of tetraethyl orthosilicate (TEOS) as the precursor solution for the formation of SiO2. The synthesis of microencapsulated LA was carried out at 2.5 pH of precursor solution. The synthesized microencapsulated LA are characterized by Fourier transform infrared spectroscope (FT-IR) and X-Ray Diffraction (XRD) which confirmed the presence of SiO2 shell on the surface of LA.

  • PDF

Synthesis and Characteristics of Different Ratio of Stearic Acid with SiO2 Shell Through Sol-Gel Process (Sol-gel 공정을 통한 SiO2 쉘과의 상이한 스테아산 비율의 합성 및 특성)

  • Ishak, Shafiq;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.66-67
    • /
    • 2020
  • The synthesis of stearic acid composite phase change material (PCM) was investigated and the samples produced were characterized for use in latent heat storage, using a simple chemical sol-gel process. The PCM was encapsulated to tetraethyl orthosilicate by various preparation ratios of stearic acid (5, 10, 15, 20, 30 and 50%). Fourier transformation infrared spectroscope (FT-IR) and X-Ray diffraction (XRD) were performed to determine the chemical structure and crystalloid phase of the microencapsulated PCM. SATEOS1 (5%) shows the best proportion for the PCM. With the presence of stearic acid as core materials and SiO2 as the supporting materials, it does not show any chemical reaction between both of them. SATEOS1 shows promising potential for thermal energy storage as it shows a better encapsulation efficiency and good thermal stability.

  • PDF

Consideration of density matching technique of the plate type direct radiologic image system and the conventional X-ray film;first step for the subtraction (Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구)

  • So, Sung-Soo;Noh, Hyeun-Soo;Kim, Chang-Sung;Choi, Seong-Ho;Kim, Kee-Deog;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.199-211
    • /
    • 2002
  • Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9463 to 0.9925, and the standard radiographic system had the tendency to show higher R-square in shorter focal distances.

A Study on Selective Catalytic Reduction on Diesel Particulate Filter Catalyst and Coating Technology the Removal of Particulate Matters and NOx for Old Special Cargo Vehicles (노후 특수·화물 차량 PM/NOx 저감을 위한 SDPF 촉매 및 코팅 기술 연구)

  • Jeong, Kwanhyoung;Seo, Philwon;Oh, Hungsuk;Kim, Jongkook;Kang, Soyeon;Kang, Jeongho;Kim, Hyunjun;Shin, Byeongseon
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.695-699
    • /
    • 2021
  • In this study, Selective Catalytic Reduction on Diesel Particulate Filter (SDPF) after-treatment system was introduced to simultaneously remove NOx and Particulate Matters (PM) emitted from trucks and special cargo vehicles using old engine. First, in order to select an Selective Catalytic Reduction (SCR) catalyst for SDPF, the de-NOx performance of V/TiO2 and Cu-Zeolite catalysts were compared, and the SCR catalyst characteristics were analyzed through Brunauer Emmett Teller (BET), X-ray Diffraction (XRD) and NH3-TPD (Temperature Programmed Desorption). From the activity test results, the Cu-zeolite catalyst showed the best thermal stability. For optimal coating of SDPF, slurry was prepared according to the target particle size. From the coating stability and back pressure test results of SDPF according to the amount of SCR coating, As a result of comparing coating stability, back pressure, and de-NOx performance by producing A, B, and C samples for each loading amount of the SDPF catalyst, the best results were found in the B sample. The engine dynamometer test was conducted for the optimal SDPF after-treatment system, and the test results satisfied Eu-5 regulations.

Integrated Ray Tracing Model for In-Orbit Optical Performance Simulation for GOCI (통합적 광추적 모델에 의한 해양탑재체 GOCI의 궤도 상 광학 성능 검증)

  • Ham, Seon-Jeong;Lee, Jae-Min;Kim, Seong-Hui;Yun, Hyeong-Sik;Gang, Geum-Sil;Myeong, Hwan-Chun;Kim, Seok-Hwan
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.2
    • /
    • pp.1-7
    • /
    • 2006
  • GOCi (Geostationary Ocean Color Imager) is one of the COMS payloads that KARI is currently developing and scheduled to be in operation from around 2008. Its primary objective is to monitor the Korean coastal water environmental condition. We report the current progress in development of the integrated optical model as one of the key analysis tools for the GOCI in-orbit performance verification. The model includes the Sun as the emitting light source. The curved Earth surface section of 2500 km x 2500 km includingthe Korean peninsular os defined as a Lambertian scattering surface consisted of land and sea surface. From its geostationary orbit, the GOCI optical system observes the reflected light from the surfaces with varying reflectance representing the changes in its environmental conditions. The optical ray tracing technique was used to demonstrate the GOCI in-orbit performances such as red tide detection. The computational concept, simulation results and its implications to the on-going development of GOCI are presented.

  • PDF

Nondestructive Inspection of Launch Vehicle Structural Components (우주 발사체 구조 요소의 비파피검사)

  • Kong, Cheol-Won;Youn, Jong-Hoon;Park, Jae-Sung;Eun, Se-Won;Jang, Young-Soon;Yi, Yeong-Moo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.331-337
    • /
    • 2009
  • Space launch vehicles require highly reliable, lightweight structures. It is thus important to monitor the structural health of these components with nondestructive inspections. In this paper, we studied an example of a nondestructive inspection that was partially applied to the manufacture and inspection of a launch vehicle. Ultrasonic tests, X-rays, tapping, and acoustic emissions comprised the inspection method. A payload fairing, high pressure tank, fastener part, and bonding part were used as hardware to be inspected. We proposed a quantitative standard for debonding inspection of the payload fairing and acoustic emission data for the proof test of the high pressure tank. We analyzed the fracture mode of the sandwich fastener part according to frequency changes. We also proposed a standard specimen for ultrasonic inspection of bonds of different materials. The present analyses and results provide data for evaluation of the launch operation sequence to ensure launch vehicles afford high reliability.

Influence of Filler and Cure Systems on Whitening of EPDM Composites by Formation of Metal Salt (충전 시스템과 가교 시스템이 금속염 형성에 의한 EPDM 복합체의 백화에 미치는 영향)

  • Chung, Hye-Seung;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • v.47 no.3
    • /
    • pp.210-215
    • /
    • 2012
  • Whitening phenomena of the EPDM composites with different inorganic filler compositions which were aged at $90^{\circ}C$ for 7 days in air and tap water atmospheres, respectively, were investigated. The aged samples in tap water containing stearic acid exhibited severe whitening phenomena, while all the samples aged in air did not show any whitening. Depending on the filler compositions, there was no big difference in the whitening phenomena. The whitening materials were analyzed using gas chromatography/mass spectrometry (GC/MS), image analysis, energy-dispersive X-ray spectroscopy (EDX), and attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR). The whitening materials were identified to be salts of stearic acid. The salts of stearic acid were formed by reaction of metal cation in tap water and stearic acid in the sample.

Evaluation of Image Quality for Scattered X-rays using in Digital Radiography (디지털방사선영상에서 산란선의 영상특성 평가)

  • Kim, Hansol;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.395-403
    • /
    • 2022
  • Flat-panel detector (FPD) used in digital radiographic imaging systems was used to perform a quantitative power spectrum evaluation as a result of the thickness change of polymethyl methacrylate (PMMA), a tissue equivalent. As the PMMA thickness increases with the resolution-chart phantom image, the effect of the scattering line increases, indicating that the modulation characteristics decrease, and the image is bright. The results show that the noise of the image increases, and noise-power spectral images are obtained by Fourier transform to confirm by spatial frequency. Thus, it can be verified that the PMMA thickness and noise are proportional through the result of evaluating the change of resolution characteristics and representing the 2D noise-power spectrum as one-dimensional values by evaluating the change of scattering line with MTF as the PMMA thickness increases in the image.

Implementation of PACS using PDA System on Medical Images (PDA기반 의료영상의 전송시스템 구현)

  • Ji, Yeon-Sang;Dong, Kyung-Rae;Kim, Chang-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.4
    • /
    • pp.247-253
    • /
    • 2009
  • PACS(Picture archiving communication system) is a system that enables medical images such as X -ray, CT, MRI, PET to be stored electronically viewed on computer screens so that doctors and other authorized people can access search the information as needed. But if they are not in hospital area for example on holiday or at night, that are not able to access the PACS system instantly. We have to solve this problem for more efficient patient care. So we try to suggest a method that use the PDA system that wireless LAN and CDMA cellular phone are equipped. This system may help to access easier to PACS system regardless of the location and can also attribute the development of telemedicne.