• Title/Summary/Keyword: X-ray 발생장치

Search Result 188, Processing Time 0.026 seconds

Comparison of Wedge Factors of Dynamic Wedge and Physical Wedge (기능상쐐기와 물질쐐기의 쐐기인수의 비교)

  • Kim Jae Sung;Kang Wee-Saing
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.237-246
    • /
    • 2004
  • Even though the wedge factor was defined by ICRU, RTPS uses other definition different from the wedge factor to consider the wedge effect to correct dose. Because the factors with different concept are defined in a very different way, replacement of different factor could make severe error of dose and is unacceptable because their values are very different from each other. Radiotherapy machine installed in department includes physical wedges and function of dynamic wedge by upper jaws, and Eclipse and Pinnacle$^{3}$ such as RTPS are used. The wedge factors, relative wedge output factors and wedge field output factors of physical wedges and dynamic wedges were measured by an ionization chamber in water phantom. They are analyzed and compared in according to wedge position, field size, wedge angle, X-ray quality, measurement condition. Wedge factor, relative wedge output factors and wedge field output factors of dynamic wedges comparing physical wedges have an effect of several factors. Main factors effecting to the factors of dynamic wedges were field size and wedge angle. Beam quality of X-ray introduces a few effect to the factors. Because the factors related to wedge and defined with different concepts are different from each other, to reduce dose error it should be input by values proper to RTPS.

  • PDF

Comparison of Dose Depending on the Position when Shooting Panorama and CBCT (CBCT와 panorama 촬영시 위치에 따른 선량 비교)

  • Jeong, Cheonsoo;Kim, Chongyeal
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.175-179
    • /
    • 2013
  • To find out the appropriate defensive measures for protectors and radiation workers in rotating radiation generating devices such as CBCT and panorama, irradiation dose depending on the position was compared and analyzed. The devices such as panorama DP-90-P PAX-500 (Vatech, Korea) and CBCT DCT-90-P IMPLAGRAPHY Dental CT system (Vatech, Korea) were used. As irradiation dose measuring instruments, Ion chamber model 2026 and Reader 20X5-60E were used. The exposure conditions were set as the factor used in the clinical trial. The result of the experiment showed that panorama was the highest, 81${\mu}R$, at point A where the test starts first and the lowest, 53${\mu}R$, at point D where the test ends. In case of CBCT, it was the highest, 1,021${\mu}R$, at point D where the test ends and was measured as the highest, 809.67${\mu}R$, at point A where the test starts. If protectors and radiation workers are forced to examine a patient holding him, they should be positioned in the middle of the point where X ray tube starts to rotate and the point where it ends to avoid the position where radiation dose is the most. And due to the nature of equipment, it will be the safest for them to stand at the opposite side of the machine and to uphold it from the rear rather than upholding it from the side of a patient and they should wear appropriate the protection gear.

Isotropic Compression Behavior of Lawsonite Under High-pressure Conditions (로소나이트(Lawsonite)의 압력에 따른 등방성 압축거동 연구)

  • Im, Junhyuck;Lee, Yongjae
    • Economic and Environmental Geology
    • /
    • v.49 no.1
    • /
    • pp.23-30
    • /
    • 2016
  • Powder samples of natural lawsonite (Ca-lawsonite, $CaAl_2Si_2O_7(OH)_2{\cdot}H_2O$) was studied structurally up to 8 GPa at room temperature using monochromatic synchrotron X-ray powder diffraction and a diamond anvil cell (DAC) with a methanol : ethanol : water (16 : 3 : 1 by volume) mixture solution as a penetrating pressure transmitting medium (PTM). Upon pressure increase, lawsonite does not show any apparent pressure induced expansion (PIE) or phase transition. Pressure-volume data were fitted to a second-order Birch-Murnaghan equation of state using a fixed pressure derivative of 4 leading to a bulk modulus ($B_0$) of 146(6) GPa. This compression is further characterized to be isotropic with calculated linear compressibilities of ${\beta}^a=0.0022GPa^{-1}$, ${\beta}^b=0.0024GPa^{-1}$, and ${\beta}^c=0.0020GPa^{-1}$.

Jet A-1 Coking Tests under Conditions Simulating Gas Turbine Combustor (가스터빈 연소기 모사 조건에서의 Jet A-1 코킹시험)

  • Lee, Dain;Lee, Kangyeong;Han, Sunwoo;Ahn, Kyubok;Ryu, Gyong Won
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • In a gas turbine, fuel is exposed to a high temperature environment until it is fed to the combustor through the injector. Hydrocarbon fuels can coke under high temperature conditions, which can cause coking material to deposit on fuel lines or block the injector passages. In this study, a specimen simulating a fuel line located inside a gas turbine and Jet A-1 were heated using electric devices. Jet A-1 coking tests were performed by changing the wall temperature of the stainless steel specimen and the temperature of Jet A-1 supplied to the specimen. After the coked specimens were cut, the coking material and the inner surface were analyzed using an energy dispersive X-ray spectrometer and a field emission scanning electron microscope.

유리화 비정형 탄소(vitreous carbon)를 이용하여 제작한 전계방출 소자의 균일성 증진방법

  • 안상혁;이광렬
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.53-53
    • /
    • 1999
  • 전계방출을 이용한 평판 표시장치는 CRT가 가진 장점을 모두 갖는 동시에 얇고 가벼우며 낮은 전력소모로 완벽한 색을 구현할 수 있는 차세대 표시장치로서 이에 대한 여국가 활발히 이루어지고 있다. 여기에 사용되는 음극물질로서 실리콘이나 몰리 등을 팁모양으로 제작하여 사용해 왔다. 하지만 잔류가스에 의한 역스퍼터링이나 화학적 반응에 의해서 전계방출 성능이 점차 저하되는 등의 해결해야할 많은 문제가 있다. 이러한 문제들을 해결하기 위하여 탄소계 재료로서 다이아몬드, 다이아몬드상 카본 등을 이용하려는 노력이 진행되어 왔다. 이중 유리화 비정형 탄소는 다량의 결함을 가지고 있는 유리질의 고상 탄소 재로로서, 전기전도도가 우수하면서 outgassing이 적고 기계적 강도가 뛰어나며 고온에서도 화학적으로 안정하여 전계방출 소자의 음극재료로서 알맞은 것으로 생각된다. 유리화 비정형 탄소가루를 전기영동법으로 기판에 코팅하여 전계방출 소자를 제작하였다. 전기영동 용액으로 이소프로필알코올에 질산마그네슘과 소량의 증류수, 유리화 비정형 탄소분말을 섞어주었고 기판으로는 몰리(Mo)가 증착된 유리를 사용하였다. 균일한 증착을 위해서 증착후 역전압을 걸어 주는 방법과 증착 후 플라즈마 처리를 하는 등의 여러 가지 방법을 사용했다. 전계방출 전류는 1$\times$10-7Torr이사에서 측정하였다. 1회 제작된 용액으로 반복해서 증착한 횟수에 따라 표면의 거치기, 입자의 분포, 전계방출 측정 결과 등의 차이가 관찰되었다. 발광이미지는 전압에 따라 변화하였고, 균일한 발광을 관찰하기 위해서 오랜 시간동안 aging 과정을 거쳐야 했다. 그리고 구 모양의 양극을 사용해서 위치를 변화시키며 시동 전기장을 관찰하여 위치에 따른 전계방출의 차이를 조사하여 발광의 균일성을 알 수 있었다.on microscopy로 분석하였으며 구조 분석은 X-선 회절분석, X-ray photoelectron spectroscopy 그리고Auger electron spectroscope로 하였다. 증착된 산화바나듐 박막의 전기화학적 특성을 분석하기 위하여 리튬 메탈을 anode로 하고 EC:DMC=1:1, 1M LiPF6 액체 전해질을 사용한 Half-Cell를 구성하여 200회 이상의 정전류 충 방전 시험을 행하였다. Half-Cell test 결과 박막의 결정성과 표면상태에 따라 매우 다른 전지 특성을 나타내었다.도상승율을 갖는 경우가 다른 베이킹 시나리오 모델에 비해 효과적이라 생각되며 초대 필요 공급열량은 200kW 정도로 산출되었다. 실질적인 수치를 얻기 위해 보다 고차원 모델로의 해석이 필요하리라 생각된다. 끝으로 장기적인 관점에서 KSTAR 장치의 베이킹 계획도 살펴본다.습파라미터와 더불어, 본 연구에서 새롭게 제시된 주기분할층의 파라미터들이 모형의 학습성과를 높이기 위해 함께 고려된다. 한편, 이러한 학습과정에서 추가적으로 고려해야 할 파라미터 갯수가 증가함에 따라서, 본 모델의 학습성과가 local minimum에 빠지는 문제점이 발생될 수 있다. 즉, 웨이블릿분석과 인공신경망모형을 모두 전역적으로 최적화시켜야 하는 문제가 발생한다. 본 연구에서는 이 문제를 해결하기 위해서, 최근 local minimum의 가능성을 최소화하여 전역적인 학습성과를 높여 주는 인공지능기법으로서 유전자알고리즘기법을 본 연구이 통합모델에 반영하였다. 이에 대한 실증사례 분석결과는 일일 환율예측문제를 적용하였을 경우, 기존의 방법론보다 더 나운 예측성과를 타나내었다.pective" to workflow architectural discussions. The vocabulary suggested

  • PDF

The Solution to the Limitation of the Conventional Digital X-ray System and Its Feasibility Test (디지털 X선 촬영장치의 한계 검사 개선 및 유용성 평가)

  • Gil, Jong-Won;Park, Jeong-Ho;Bae, Seok-Hwan;Hwang, Hye-Jeong;Kim, Yong-Gwon
    • Journal of Digital Convergence
    • /
    • v.12 no.12
    • /
    • pp.371-379
    • /
    • 2014
  • In this study, we conducted a survey on the limited examinations of the DR system to the 30 radiologic technologists engaging in the clinical sites and university hospitals in Daejeon metropolitan city from Oct. 15, 2012 to Nov. 15, 2012. Based on the survey results, we propose the conceptual design of a supplementary table for the conventional DR system to extend the examination capability and overcome the limitation of DR system. And, we evaluated the convenience and usefulness of the proposed table by applying it to five subjects. Ten experts were involved to evaluate the clinical usefulness of the obtained images. In this study, the experimental results show the feasibility to overcome the limited examination of the conventional DR system, and the proposed supplementary table may be beneficial to patients and hospitals.

Development and Usefulness Evaluation of Virtual Reality Simulator for Education of Spatial Dose Rate in Radiation Controlled Area (방사선관리구역의 공간선량률 교육을 위한 가상현실 시뮬레이터의 개발과 유용성 평가)

  • Jeong-Min Seo
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.493-499
    • /
    • 2023
  • This study developed education contents of measuring spatial dose with virtual reality simulation and applied to students majoring radiological science. The virtual reality(VR) contents with measuring spatial dose rate in the radiation controlled area was developed based on the simulation from pilot study. In this simulation, the tube voltage and tube current can be set from 60 to 120 kVp in 10 kVp steps and 10 to 40 mAs in 10 mAs increments, and the distance from source can be set from 30 to 400 cm continuously. Iron and lead shields can be placed between the source and the detector, and shielding thickness can be set by 1 mm increments ranging from 1 to 20 mm. We surveyed to students for evaluating improvement of understanding spatial dose rate between before and after education by VR simulation. The survey was conducted with 5 questions(X-ray exposure factors, effects by distance from the source, effects from using shield, depending on material and thickness of shield, concept and measuring of spatial dose rate) and all answers showed significant improvement. Therefore, this VR simulation content will be well used in education for spatial dose rate and radiation safety environments.

Effects of Field Configuration Shielding Area and Changing of Density and Sensitivity on Tube Current and Image Quality in Automatic Exposure Control System (자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향)

  • Jeong, Min-Gyu;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.635-642
    • /
    • 2020
  • The purpose of this study was to analysis the effects of shielding area of field configuration with changing of sensitivity and density on tube current (milliampere-seconds, mAs) and image quality in automatic exposure control (AEC) system. The equipment used a digital radiography device (Digital Diagnost, Philips, Netherlands), which has a integral type with an X-ray tube and an indirect digital detector. The AEC system conditions were consisted of 9 setting environments, that mode changing of the sensitivity (S200, S400, S800) and the density (+2.5, 0, -2.5). The tube current evaluated automatically exposed mAs under 81 combination conditions crossed by AEC conditions in fixed at 40 kVp. The image quality evaluated the radiographic images that selected valid images by visual assessment the radiographic images of the self-produced conical pyramid phantom and then measured their signal to noise ratio (SNR). As a result, the maximum tube current was 60.0 mAs that automatically exposed conditions were the 100% of shielding area and the sensitivity of S200 and the density of +2.5. The minimum tube current was 0.9 mAs with non-shielding area and the sensitivity of S800 and the density of -2.5. When the shielded area 0% with the sensitivity of S200 and the density of +2.5, the maximum SNR was the highest as 25.2. But when the shielded area 25% with the sensitivity of S800 and the density of -2.5, the minimum SNR was the lowest as 4.7.

대면적 플라즈마 공정에서 자장이 내장형 선형 유도결합형 플라즈마 특성에 미치는 영향에 관한 연구

  • 경세진;이영준;김경남;염근영
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.55-55
    • /
    • 2003
  • 최근 높은 해상도의 평판 디스플레이 장치 특히 차세대 TFT-LCD를 개발하기 위해서는 건식식각공정의 개발이 필수 불가결하며 이는 플라즈마 공정장치의 대면적화가 가능해야 한다. 따라서 산업계는 이러한 제조 조건에 알맞는 대면적 플라즈마 반응기 개발을 추구하고 있다. 이를 위해서는 건식식각공정의 개발이 필수 불가결하며 이를 위해선 플라즈마 공정장 치의 대면적화가 가능해야 한다. 이러한 대면적 공정을 위해서는 낮은 공정압력, 고밀도, 높은 플라즈마 균일도가 요구된다. 또한 이러한 대면적 고밀도 플라즈마에의 적용을 위하여 새로운 유도결합형 플라즈마 소오스의 개발이 진행되고 있으며, 안정적인 300mm웨이퍼 공정을 위하여 여러 형태의 안테나가 연구되어지고 있다. 그러나 차세대 TFT-LCD에 적용 가 능하게끔 기존의 ICP 소오스를 직접적으로 대면적화 하는데 있어서는 안테나의 인덕턴스의 값이 키지며, 유전물질의 두께 증가 및 그에 따른 재료비의 상슴에 의해 그 한계점을 나타 내었다. 본 연구에서는 차세대 TFT-LCD 및 POP 대면적 공정에 적용 가능한 고밀도 플라즈마를 발생시키기 위해서 내장형 유도결합형 선형 안테나를 사용하였다. 내장형 유도결합형 선형 안테나가 가지고 있는 고유의 정전기적 결합효과를 최소화시키기 위해 직사각형모양의 플라즈마 챔버(830mm*1,020mm)에서 영구자석을 사용하였다. 영구자석을 사용하여 외부자 장을 인가하였을 때가, 그럴지 않은 때보다 RF 안테나에 걸리는 코일의 전압을 낮춰주었으며, 영구자석의 배열에 따라 코일의 인덕턴스의 값이 크게 변함을 알 수 있었다. 그리고, 최적화된 자장의 배열은 플라즈마의 이온밀도를 증가시켰으며, 플라즈마 균일도 또한 10% 이 내로 유지됨을 알 수 있었다. 따른 식각 메커니즘에 대하여 알아보고자 하였다. $CF_4/Cl_2$ gas chemistry 에 첨 가 가스로 $N_2$와 Ar을 첨 가할 경 우 텅 스텐 박막과 하부 layer 간의 etch selectivity 증가는 관찰되지 않았으며, 반면에 첨가 가스로 $O_2$를 사용할 경우, $O_2$의 첨가량이 증가함에 따라 etch s selectivity 는 계속적으로 증가렴을 관찰할 수 있었다. 이는 $O_2$ 첨가에 따라 형성되는 WOF4 에 의한 텅스텐의 etch rates 의 감소에 비하여, $Si0_2$ 등의 형성에 의한 poly-Si etch rates 이 더욱 크게 감소하였기 때문으로 사료된다. W 과 poly-Si 의 식각 특성을 이해하기 위하여 X -ray photoelectron spectroscopy (XPS)를 사용하였으며, 식각 전후의 etch depth 를 측정하기 위하여 stylus p pmfilometeT 를 이용하였다.X> 피막이 열처리 전후에 보아는 기계적 특성의 변화 양상은 열역학적으로 안정한 Wurzite-AlN의 석출에 따른 것으로 AlN 석출상의 크기에 의존하며, 또한 이러한 영향은 $(Ti_{1-x}AI_{x})N$ 피막에 존재하는 AI의 함량이 높고, 초기에 증착된 막의 업자 크기가 작을 수록 클 것으로 여겨진다. 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로

  • PDF

Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control (자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향)

  • Kang-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.257-265
    • /
    • 2024
  • In this study, we applied AEC(Auto Exposure Control), which is used in many chest examinations, to evaluate whether medical devices inserted into the body affect the dose and image quality of chest images. After attaching three HIMD(Human implantable medical devices) to the ion chamber, the Monte Carlo methodology-based program PCXMC(PC Program for X-ray Monte Carlo) 2.0 was applied to measure the effective dose by inputting the DAP(Dose Ares Product) value derived from the Pacemaker and CRT and Chemoport Additionally, to evaluate image quality, we set three regions of interest and one noise region on the chest and measured SNR and CNR. The final study results showed significant differences in DAP and Effective dose. There was a significant difference between Pacemaker and CRT when AEC was applied and not applied. (p<0.05) When applied, the dose increased by 37% for Pacemaekr and 52% for CRT. Chemoport showed a 10% increase in effective dose depending on whether AEC was applied, but there was no significant difference. (p>0.05) In the image quality evaluation, there was no significant difference in image quality between all HIMD insertions and AEC applied or not. (p>0.05) Therefore, when the HIMD was inserted into the chest during a chest x ray and overlapped with the ion chamber sensor, the effective dose increased, and there was no difference in image quality even at a low dose without AEC. Therefore, when performing a chest X-ray examination of a patient with a HIMD inserted, it is considered that performing the examination without applying AEC is a method that can be considered to reduce the patient's radiation exposure.