• Title/Summary/Keyword: X-means

Search Result 1,314, Processing Time 0.027 seconds

The Study on Relation between Cervical Lateroflexion and Upper Limb Numbness of Patients without Disc Herniation after Traffic Accident (교통사고 이후 디스크 탈출이 없이 상지 저림을 호소하는 환자의 경추 측굴과 상지 저림에 관한 연구)

  • Park, Hyun-Min;Park, Ji-Yong;Kim, Dong-Sub;Kim, Eun-Soo;Kim, Mi-Riong;Cho, Nam-Hoon;Jeong, Hoon;Seong, Ik-Hyun;Kim, Min-Woo;Hong, Nam-Jung;Ha, In-Hyuk;Lee, Jin-Ho
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.8 no.2
    • /
    • pp.21-29
    • /
    • 2013
  • Objectives : The purpose of this study is to investigate the relation between cervical spine lateroflexion and upper limb numbness after whiplash injury by traffic accident. Methods : Outpatients who visited Jaseng korean medicine hospital after traffic accident took cervical MRI. Patients who had Normal disc and bulging disc were reviewed to measure the cervical lateroflexion by C2-C7 Cobb's angle & scalenus muscle's length through neutrality AP X-ray views. For statistics, we used SPSS version 18.0 for windows. Results : Groups classified into difference of scalenus muscle's length were showen statistical significance than into cobb's angle. Means of numbness group's length difference are $4.18{\pm}2.26mm$ and that of non-numbness group is $1.59{\pm}1.17mm$. Unilateral numbness group had greater angle and longer of length's difference than non-numbness group. Conclusions : The more severe the lateroflexion of the upper extremity numbness occurs well. Group classifed into difference of scalenus muscle's length has more tendency of occurrence of upper limb numbness than that into cobb's angle. And upper limb numbness occurs more frequently at the same direction of lateroflexion.

  • PDF

The Measurements of Energy and Distribution of Scattered Electrons in Therapeutic X-Ray Beam (치료 방사선 선속(Flux)에 포함된 산란전자의 분포와 에너지 측정)

  • Vahc, Young-Woo;Park, Kyung-Ran;Ohyun Kwon;Lee, Yong-Ha;Kim, Tae-Hong;Kim, Sookil
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • Accurate knowledge of the distribution of contamination electrons ( which comes from mainly gantry head by Compton scattering, pair production, and tray: henceforth called leptons ) at the surface and in the first centimeters of tissue is essential for the clinical practice of radiation oncology. Such lepton tends to reduce or eliminate the ‘skin-sparing’ advantage of megavoltage photon beam radiotherapy, This information is needed to prescribe a absorbed dose to a skin volume at a few millimeter depth in high energy therapeutic radiation photon beam All experiments were done with 15 MV photon beam from a dual energy linear accelerator (Clinac 1800, Varian). Field size is defined by ranged from 10.0$\times$10.0 to 30.0$\times$30.0 $\textrm{cm}^2$. The absorbed dose and distribution of leptons in therapeutic radiation beam (15 MV) are investigated by means of variable blocked beams of 30.0$\times$30.0 $\textrm{cm}^2$ and dose beam profiles partly removed leptons with a copper plate. A numerous leptons mainly are distributed as shape of broad cone in the central photon beam and leptons path length in the water are shorter than 2.5 cm because of the leptons energy having around 3.0 MeV. These results clearly appears that the subtraction of leptons from the total depth dose curve not only lower the absolute dose in the buildup region and surface dose, it also causes a shift of d$_{max}$ to a deeper depth.

  • PDF

A STUDY OF ION BEAM ASSISTED DEPOSITION(IBAD) OF TiN ON Ni-Cr Be ALLOY FOR SURFACE CHARACTERISTIC (이온빔 보조 증착법에 의한 TiN 박막도포가 니켈-크롬-베릴륨 합금의 표면 성상에 미치는 영향에 관한 연구)

  • Choi, Soo-Young;Lee, Sun-Hyung;Chang, Ik-Tae;Yang, Jae-Ho;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.212-234
    • /
    • 1999
  • Dental restorative materials must have the physical properties to withstand wear and corrosion. Base metal alloys possess better mechanical properties and lower price than the gold alloys. For these reasons such alloys have largely replaced the precious metal alloys. One aspect to con-sider is the release of metal substances to oral environment. The release of elements from dental alloys is a continuing concern because the elements may have the potentially harmful biological effects on local tissues. The purpose of this study was to minimize metal release on the nonprecious metal surfaces by ion beam assisted deposition(IBAD) of titanium nitride (TiN) Ni-Cr-Be alloys with and without TiN coatings were secured in an wear test machine opposing ruby ball to determine their relative resistance to wear with loom, 200m, 300m and 400m sliding distance. And the corrosion behavior of the Ni-Cr-Be alloys with and without TiN coatings and 3 dental noble alloys have been studied. Potentiodynamic curves were used to analyse the corrosion characteristics of the alloys. The measurement of the released Ni and Cr ions was conducted by analysis of the electrolyte solution with atomic absorption spectroscopy. The results were as follows : 1. The critical sliding distance that wore down TiN coatings of $2.5{\mu}m$ thickness in this study condition was 300m. 2. Ion beam assisted deposition of TiN showed a good surface modification with respect to the properties of wear and corrosion resistance. 3. X-ray diffraction showed that the strongest peak of TiN is TiN(111) in the coatings. 4. The release of Ni and Cr ions from alloys measured by means of atomic absorption spectroscopy was reduced by ion beam assisted deposition of TiN.

  • PDF

Luminous Characteristics of Transparent Field Emitters Produced by Using Ultra-thin Films of Single Walled Carbon Nanotubes

  • Jang, Eun-Soo;Goak, Jeung-Choon;Lee, Han-Sung;Lee, Seung-Ho;Lee, Nae-Sung
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.31.1-31.1
    • /
    • 2009
  • Carbon nanotubes (CNTs) are attractive material because of their superior electrical, mechanical, and chemical properties. Furthermore, their geometric features such as a large aspect ratio and a small radius of curvature at tip make them ideal for low-voltage field emission devices including backlight units of liquid crystal display, lighting lamps, X-ray source, microwave amplifiers, electron microscopes, etc. In field emission devices for display applications, the phosphor anode is positioned against the CNT emitters. In most case, light generated from the phosphor by electron bombardment passes through the anode front plate to reach observers. However, light is produced in a narrow depth of the surface of the phosphor layer because phosphor particles are big as much as several micrometers, which means that it is necessary to transmit through the phosphor layer. Hence, a drop of light intensity is unavoidable during this process. In this study, we fabricated a transparent cathode back plate by depositing an ultra-thin film of single walled CNTs (SWCNTs) on an indium tin oxide (ITO)-coated glass substrate. Two types of phosphor anode plates were employed to our transparent cathode back plate: One is an ITO glass substrate with a phosphor layer and the other is a Cr-coated glass substrate with phosphor layer. For the former case, light was radiated from both the front and the back sides, where luminance on the back was ~30% higher than that on the front in our experiments. For the other case, however, light was emitted only from the cathode back side as the Cr layer on the anode glass rolled as a reflecting mirror, improving the light luminance as much as ~60% compared with that on the front of one. This study seems to be discussed about the morphologies and field emission characteristics of CNT emitters according to the experimental parameters in fabricating the lamps emitting light on the both sides or only on the cathode back side. The experimental procedures are as follows. First, a CNT aqueous solution was prepared by ultrasonically dispersing purified SWCNTs in deionized water with sodium dodecyl sulfate (SDS). A milliliter or even several tens of micro-liters of CNT solution was deposited onto a porous alumina membrane through vacuum filtration. Thereafter, the alumina membrane was solvated with the 3 M NaOH solution and the floating CNT film was easily transferred to an ITO glass substrate. It is required for CNT film to make standing CNTs up to serve as electron emitter through an adhesive roller activation.

  • PDF

Study on the Repeatability and Reproductivity of a Moire Body Shape Analyser (모아레를 이용한 체형분석의 반복성 재현성에 관한 연구)

  • Lee, Dong-Yup;Park, Young-Bae;Oh, Hwan-Sub
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.10 no.2
    • /
    • pp.121-131
    • /
    • 2006
  • Background : As each human has a look in the face of oneself, he or she has a look of him or herself in the shape of the body also. And for the shape of the body which gives a big clue in diagnosis in musculoskeletal disorders. Therefor many means are used and developed for diagnosis through body shape or posture analysis for musculoskeletal disorders. X-ray, CT, MRI has been used for diagnosis through image in this way to tell about the inside of the human body. On the other side, moire topography was used for information about the exterior of the human body, but yet only minimal information such as the number of contour lines in each side was available. Therefor there were a few studies to use moire topography or other methods to get information about the surface of the human body in numeric values. The instrument used in this study which is a laser projection moire, is another trial to get numeric data about the surface of the human body. The instrument is composed of laser projector and a computer software to recompose and analyse the image data into depth, height, angle and length. Objectives : The study was focused on whether the instrument is reliable for clinic use, and to seek the proper environment and posture for the examination, and among the data the software provides, which items are more reliable and useful. Methods : For reproductivity and repeatability, 4 testers tested 2 persons. And to how if the body shape changes according to the posture and which posture gives the most reliable data, the test was performed in 6 different positions. Results : Result, the instrument showed sufficient repeatability and reproductivity for clinical use. And among the items the software provides, the length of the back, the angle of the back in the sagittal and coronal plane showed reliable results. And there was difference in the results according to the posture, and Therefor, in following studies using this instrument or similar type of posture analysing instruments, the length of the back, the angle of the back in the sagittal and coronal plane could be reliable item to use.

  • PDF

MORPHOLOGY OF THE APICAL ROOT CANAL SYSTEM IN KOREAN MANDIBULAR FIRST MOLAR (하악 제1 대구치 근단부의 형태학적 연구)

  • Jeong, Hyeon;Park, Sang-Jin;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.137-144
    • /
    • 2009
  • The aim of this study was to investigate the shapes and diameters of the physiological foramen and anatomy of the root canal at 3mm from apex in mandibular first molars. Sixty mandibular first molars were randomly selected. The apical anatomy of 60 mandibular first molars was investigated by means of a stereo microscope (60x magnification). The results were as follows; 1. There was a high percentage of two physiological foramina in mesial (61.67%) and one foramen in distal(71.66%) roots of mandibular first molars. 2. There was a high frequency of accessory foramina in mesial roots with one foramen (26.07%). 3. The diameters of physiological foramen was as follows: - 0.329mm in single mesial foramen - 0.266mm in mesiobuccal foramen and 0.246mm in mesiolingual foramen - 0.375mm in single distal foramen - 0.291mm in distobuccal foramen and 0.237mm in distolingual foramen 4. The most common physiological foramen shape was oval (69.93%). 5. The incidence of isthmus in mesial root at 3mm from apex was 55%. The 3mm-sections contained a complete isthmus 31.66% and a partial isthmus 23.34%. 6. 3mm from the apex, the most common canal shape was oval (50.64%). Knowledge of the apical anatomy of mandibular first molar would be necessary for success of surgical and nonsurgical endodontic treatment.

Growth and Optical Conductivity Properties for BaAl2Se4 Single Crystal Thin Film by Hot Wall Epitaxy (Hot Wall Epitaxy(HWE)법에 의한 BaAl2Se4 단결정 박막 성장과 광전도 특성)

  • Jeong, Junwoo;Lee, Kijung;Hong, Kwangjoon
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.404-411
    • /
    • 2015
  • A stoichiometric mixture of evaporating materials for $BaAl_2Se_4$ single crystal thin films was prepared from horizontal electric furnace. To obtain the single crystal thin films, $BaAl_2Se_4$ mixed crystal was deposited on thoroughly etched semi-insulating GaAs(100) substrate by the Hot Wall Epitaxy (HWE) system. The source and substrate temperatures were $610^{\circ}C$ and $410^{\circ}C$, respectively. The crystalline structure of the single crystal thin films was investigated by the photoluminescence and double crystal X-ray diffraction (DCXD). The carrier density and mobility of $BaAl_2Se_4$ single crystal thin films measured from Hall effect by van der Pauw method are $8.29{\times}10^{-16}cm^{-3}$ and $278cm^2/vs$ at 293 K, respectively. The temperature dependence of the energy band gap of the $BaAl_2Se_4$ obtained from the absorption spectra was well described by the Varshni's relation, $E_g(T)=3.4205eV-(4.3112{\times}10^{-4}eV/K)T^2/(T+232 K)$. The crystal field and the spin-orbit splitting energies for the valence band of the $BaAl_2Se_4$ have been estimated to be 249.4 meV and 263.4 meV, respectively, by means of the photocurrent spectra and the Hopfield quasicubic model. These results indicate that the splitting of the ${\Delta}so$ definitely exists in the ${\Gamma}_5$ states of the valence band of the $BaAl_2Se_4/GaAs$ epilayer. The three photocurrent peaks observed at 10 K are ascribed to the $A_1$-, $B_1$-exciton for n =1 and $C_{31}$-exciton peaks for n=31.

Treatment of Phalangeal Bone Defect Using Autologous Stromal Vascular Fraction from Lipoaspirated Tissue (자가기질혈관분획을 이용한 수지골 결손 환자의 치료)

  • Jeong, Tae-Won;Ji, Yi-Hwa;Kim, Deok-Woo;Dhong, Eun-Sang;Yoon, Eul-Sik
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.438-444
    • /
    • 2011
  • Purpose: Adipose-derived stromal cells (ASCs) are readily harvested from lipoaspirated tissue or subcutaneous adipose tissue fragments. The stromal vascular fraction (SVF) is a heterogeneous set of cell populations that surround and support adipose tissue, which includes the stromal cells, ASCs, that have the ability to differentiate into cells of several lineages and contains cells from the microvasculature. The mechanisms that drive the ASCs into the osteoblast lineage are still not clear, but the process has been more extensively studied in bone marrow stromal cells. The purpose of this study was to investigate the osteogenic capacity of adipose derived SVF cells and evaluate bone formation following implantation of SVF cells into the bone defect of human phalanx. Methods: Case 1 a 43-year-old male was wounded while using a press machine. After first operation, segmental bone defects of the left 3rd and 4th middle phalanx occurred. At first we injected the SVF cells combined with demineralized bone matrix (DBM) to defected 4th middle phalangeal bone lesion. We used P (L/DL)LA [Poly (70L-lactide-co-30DL-lactide) Co Polymer P (L/DL)LA] as a scaffold. Next, we implanted the SVF cells combined with DBM to repair left 3rd middle phalangeal bone defect in sequence. Case 2 was a 25-year-old man with crushing hand injury. Three months after the previous surgery, we implanted the SVF cells combined with DBM to restore right 3rd middle phalangeal bone defect by syringe injection. Radiographic images were taken at follow-up hospital visits and evaluated radiographically by means of computerized analysis of digital images. Results: The phalangeal bone defect was treated with autologous SVF cells isolated and applied in a single operative procedure in combination with DBM. The SVF cells were supported in place with mechanical fixation with a resorbable macroporous sheets acting as a soft tissue barrier. The radiographic appearance of the defect revealed a restoration to average bone density and stable position of pharyngeal bone. Densitometric evaluations for digital X-ray revealed improved bone densities in two cases with pharyngeal bone defects, that is, 65.2% for 4th finger of the case 1, 60.5% for 3rd finger of the case 1 and 60.1% for the case 2. Conclusion: This study demonstrated that adipose derived stromal vascular fraction cells have osteogenic potential in two clinical case studies. Thus, these reports show that cells from the SVF cells have potential in many areas of clinical cell therapy and regenerative medicine, albeit a lot of work is yet to be done.

Effect of Mesoporous TiO2 in Facilitated Olefin Transport Membranes Containing Ag Nanoparticles (나노입자가 포함된 촉진수송 분리막에서의 메조기공 티타늄산화물의 영향)

  • Kim, Sang Jin;Jung, Jung Pyu;Kim, Dong Jun;Kim, Jong Hak
    • Membrane Journal
    • /
    • v.25 no.5
    • /
    • pp.398-405
    • /
    • 2015
  • Facilitated transport is considered to be a possible solution to simultaneously improve permeability and selectivity, which is challenging in normal polymeric membranes based on solution-diffusion transport only. We investigated the effect of adding mesoporous $TiO_2$ ($m-TiO_2$) upon the separation performance of facilitated olefin transport membranes comprising poly(vinyl pyrrolidone), Ag nanoparticles, and 7,7,8,8-tetracyanoquinodimethane as the polymer matrix, olefin carrier, and electron acceptor, respectively. In particular, $m-TiO_2$ was prepared by means of a facile, mass-producible method using poly(vinyl chloride)-g-poly(oxyethylene methacrylate) graft copolymer as the template. The crystal phase of $m-TiO_2$ consisted of an anatase/rutile mixture, of crystallite size approximately 16 nm as determined by X-ray diffraction. The introduction of $m-TiO_2$ increased the membrane diffusivity, thereby increasing the mixed-gas permeance from 1.6 to 16.0 GPU ($1GPU=10^{-6}cm^3$(STP)/($s{\times}cm^2{\times}cmHg$), and slightly decreased the propylene/propane selectivity from 45 to 37. However, both the mixed-gas permeance and selectivity of the membrane containing $m-TiO_2$ rapidly decreased over time, whereas the membrane without $m-TiO_2$ had more stable long-term performance. This difference might be attributed to specific chemical interactions between $TiO_2$ and Ag nanoparticles, causing Ag to lose activity as an olefin carrier.

Development of Robotic System based on RFID Scanning for Efficient Inventory Management of Thick Plates (효율적인 후판 재고관리를 위한 RFID 스캐닝 로봇 시스템 개발)

  • Lee, Kwang-Hyoung;Min, So-Yeon;Lee, Jong-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.1-8
    • /
    • 2016
  • Automation of inventory management in a steel plate factory was a difficult problem unresolved for a long time. And now, it is also necessary to work diligently in the steel industry on efficient inventory management of thick plates. So far, the environmental characteristics of stacked thick plates means it is not easy to apply advanced technology for their automatic identification. In this paper, we propose a thick-plate robotic scanning system based on radio-frequency identification (RFID) that can provide quick and accurate inventory management by acquiring plate information after the scanning automatically recognizes the RFID tags under difficult load conditions. This system is equipped with a crane to move the plates in a pulled-up operation. It is equipped with a plate-only linear dipole antenna only for scanning the position of the plate tag. Only the linear dipole antenna, while moving the x-axis and y-axis information, automatically identifies the tag information attached to the plate. The tag information acquired by the system is used for stockpiling and is managed by steel plate inventory control software. The effectiveness of the proposed system is verified through field performance evaluation. As a result, the recognition rate of the plate tags is 99.9% at a maximum distance of 320 cm. The developed thick-plate antenna showed excellent performance compared to an existing commercial antenna.