• Title/Summary/Keyword: X-Ray structure

Search Result 3,699, Processing Time 0.032 seconds

Synthesis, Structure, and Thermal Property of Poly(trimethylene terephthalate- co-trimethylene 2,6-naphthalate) Copolymers

  • Jeong, Young-Gyu;Jo, Won-Ho;Lee, Sang-Cheol
    • Fibers and Polymers
    • /
    • v.5 no.3
    • /
    • pp.245-251
    • /
    • 2004
  • Poly(trimethylene terephthalate-co-trimethylene 2,6-naphthalate)s (P(TT-co-TN)s) with various copolymer composition were synthesized, and their chain structure, thermal property and crystalline structure were investigated by using $^1$H-NMR spectroscopy, differential scanning calorimetry (DSC) and wide-angle X-ray diffraction (WAXD), respectively. It was found from sequence analysis that all the P(TT-co-TN) copolymers synthesized have a statistical random distribution of TT and TN units. It was also observed from DSC thermograms that the glass transition temperature increases linearly with increasing the TN comonomer content, whereas the melting temperature of copolymer decreases with increasing the corresponding comonomer content in respective PTT- and PTN-based copolymer, showing pseudo-eutectic melting behavior. All the samples melt-crystallized isothermally except for P(TT-co-66 mol % TN) exhibit multiple melting endotherms and clear X-ray diffraction patterns. The multiple melting behavior originates from the dual lamellar population and/or the melting-recrystallization-remelting. The X-ray diffraction patterns are largely divided into two classes depending on the copolymer composition, i.e., PTT and PTN $\beta$-form diffraction patterns, without exhibiting cocrystallization.

Electron Crystallography of CaMoO4 Using High Voltage Electron Microscopy

  • Kim, Jin-Gyu;Choi, Joo-Hyoung;Jeong, Jong-Man;Kim, Young-Min;Suh, Il-Hwan;Kim, Jong-Pil;Kim, Youn-Joong
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.391-396
    • /
    • 2007
  • The three-dimensional structure of an inorganic crystal, CaMoO4 (space group I 41/a, a = 5.198(69) A and c = 11.458(41) A), was determined by electron crystallography utilizing a high voltage electron microscope. An initial structure of CaMoO4 was determined with 3-D electron diffraction patterns. This structure was refined by crystallographic image processing of high resolution TEM images. X-ray crystallography of the same material was performed to evaluate the accuracy of the TEM structure determination. The cell parameters of CaMoO4 determined by electron crystallography coincide with the X-ray crystallography result to within 0.033-0.040 A, while the atomic coordinates were determined to within 0.072 A.

A Study On Structure Change of Binding Actin and Moysin On The Contracting Muscle Membrane (수축중인 근육막에서 actin과 myosin 결합의 구조변화에 관한 연구)

  • Kim, Duck-Sool;Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.380-387
    • /
    • 2008
  • The effects of the applied stretch and MgADP binding on the structure of the actin and myosin cross-bridges in rabbit fibers in the rigor state have been investigatedwith improved resolution by x-ray diffraction using synchrotron radiation. To clarify the structure of the ATP hydrolysis intermediates formed by actin and myosin cross-bridges,the effects of various phosphate analogs in the of MgADP on the structure of the thin and thick filaments in glycerinated rabbit muscle fibers in the rigor state investigated by x-ray diffraction with a short exposure time using synchrotron radiation. These results strongly suggest that when MgADP and phosphate analogs such as metallofluorides(BeF3 and AlF4)and vanadate(VO4(Vi)) were added the rigor fibers in the presence of the ATP-depletion backup system, the intensities of the actin-based layer lines were markedly weakened. We found that the intensity of the 14.5 nm-based meridional reflections increase by 20-50% when phosphate analogs such as metallofluorides(BeF3 and AlF4) and vanadate(VO4(Vi)) was added to the rigor muscle.

Effects of Sputter Parameters on Electrochromic Properties of Tungsten Oxide Thin Films Grown by RF Sputtering

  • Nah, Yoon-Chae
    • Korean Journal of Materials Research
    • /
    • v.21 no.12
    • /
    • pp.703-707
    • /
    • 2011
  • The electrochromic properties of tungsten oxide films grown by RF sputtering were investigated. Among the sputter parameters, first the $Ar:O_2$ ratios were controlled with division into only an $O_2$ environment, 1:1 and 4:1. The structure of each film prepared by these conditions was studied by X-ray diffraction, X-ray photoelectron spectroscopy and Rutherford backscattering spectroscopy. The sputter-deposited tungsten oxide films had an amorphous structure regardless of the $Ar:O_2$ ratios. The chemical compositions, however, were different from each other. The stoichiometric structure and low-density film was obtained at higher $O_2$ contents. Electrochemical tests were performed by cyclic voltammetry and chronoamperometry at 0.05 M $H_2SO_4$ solutions. The current density and charge ratio was estimated during the continuous potential and pulse potential cycling at -0.5 V and 1.8 V, respectively. The film grown in a higher oxygen environment had a higher current density and a reversible charge reaction during intercalation and deintercalation. The in-situ transmittance tests were performed by He-Ne laser (633 nm). At higher oxygen contents, a big transmittance difference was observed but the response speed was too slow. This was likely caused by higher film resistivity. Furthermore, the effect of sputtering pressure was also investigated. The structure and surface morphology of each film was observed by X-ray diffraction and scanning electron microscopy. A rough surface was observed at higher sputtering pressure, and this affected the higher transmittance difference and coloration efficiency.

Crystal structure analysis of orthohombic $Sr_{0.6}Ca_{0.4}CuO_2$ compound (사방정계 $Sr_{0.6}Ca_{0.4}CuO_2$ 화합물의 결정구조해석)

  • Park, H.M.;Goetz, D.;Hahn, Th.
    • Korean Journal of Crystallography
    • /
    • v.7 no.1
    • /
    • pp.20-29
    • /
    • 1996
  • Sr0.6Ca0.4CuO2 single crystal has been synthesized by flux method and characterized by the single crystal X-ray diffraction. The compound has the orthorhombic system and the space group is Cmcm(63), lattice parameters are a=3.4645Å, b=16.1417Å, c=3.8727Å. In the (Sr1-xCax)CuO2 compound the limit of Ca from substitution for Sr was determined by the change of bond length. For this, X-ray diffraction, scanning electron microscopy (SEM), energy dispersive X-ray fluorescence (EDAX) and electron probe micro-analysis (EPMA) were used. From the change of Cu-O bond length as the Ca substitution, we concluded the limit of Ca incorporation Xca≒0.73.

  • PDF

Polymerization of Tetraethoxysilane by Using Remote Argon/dinitrogen oxide Microwave Plasma

  • Chun, Tae-Il;Rossbach, Volker
    • Textile Coloration and Finishing
    • /
    • v.21 no.3
    • /
    • pp.19-25
    • /
    • 2009
  • Polymerization of tetraethoxysilane on a glass substrate was investigated by remote microwave plasma using argon with portions of nitrous oxide as carrier gas. Transparent layer like a thickness of 0.5 ${\mu}m$ 3 ${\mu}m$ were obtained, differing in chemical composition, depending on plasma power and treatment time as well as on ageing time. In general the milder the treatment and the shorter the ageing was, the higher was the content of organic structural elements in the layer. We have identified that the chemical structure of our samples composed of mainly Si O and Si C groups containing aliphatics, carbonyl groups. These results were obtained by X ray photon spectroscopy, Fourier transformed infrared spectroscopy, and scanning electron microscope combined with Energy dispersive X ray spectroscopy.

The Necessary of Portable X-ray Equipment for Emergency Medical Service System and Sports Injures (응급의료체계와 스포츠손상에서 휴대용 X-ray 장치의 도입 필요성)

  • Cho, Dong-Heon;Koo, Kyung-Wan;Jo, Jeanman
    • The Korean Journal of Emergency Medical Services
    • /
    • v.8 no.1
    • /
    • pp.189-197
    • /
    • 2004
  • The fate of a emergency patient is decided upon the extent of first aid in one hour after accident. Suitable diagnosis and treatment can raise the possibility of patient's life and reduce the recuperation time. We surveys papers which were The Korean Society Of Sports Medicine(1993-2004 yeas 405papers)and The Korean Society Of Emergency Medicine (1990-2004 yeas 797 papers). This paper got the following results through analyses of problems in emergency medical service system and of injures from sports. First, portable X-RAY equipment is needed to apply it to emergency. Second, it should have small and light structure compared with old equipments and have high voltage generator unit for X-RAY using inverter. Third, it should be able to send the shot data that is digital detector type without film to doctors in emergency center.

  • PDF

In Situ X-ray Absorption Spectroscopic Study for α-MoO3 Electrode upon Discharge/Charge Reaction in Lithium Secondary Batteries

  • Kang, Joo-Hee;Paek, Seung-Min;Choy, Jin-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.12
    • /
    • pp.3675-3678
    • /
    • 2010
  • In-situ X-ray absorption spectroscopy (XAS) was used to elucidate the structural variation of $\alpha-MoO_3$ electrode upon discharge/charge reaction in a lithium ion battery. According to the XAS analysis, hexavalent Mo atoms in $\alpha-MoO_3$ framework are reduced as the amount of intercalated lithium ions increases. As lithium de-intercalation proceeds, most of pre-edge peaks are restored again. However, according to the Fourier transforms of the extended X-ray absorption fine structure (EXAFS) spectra, lithium de-intercalation reaction is partially irreversible upon the charge reaction, which is one of the main reasons why the capacity of $\alpha-MoO_3$ electrode decreases upon successive discharge/charge cycles.

Three Dimensional Volume Reconstruction of Polyhedral Objects Using X-ray Stereo Images

  • Roh, Young-Jun;Kim, Byung-Man;Cho, Hyung-Suck
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.28.2-28
    • /
    • 2001
  • Three dimensional shape measurement techniques are widely needed in industries for product quality monitoring and control. X-ray imaging method is a promising technology to achieve three-dimensional Information, both the surface and inner structure of an object, since it can overcome the limitations of conventional visual or optical methods such as an occlusion problem or surface reflection properties. In this paper, we propose three dimensional volume reconstruction method based on x-ray stereo imaging technology. Here, the stereo images of an object from two different views are taken by changing the object pose rather than moving imaging plane as in conventional stereo vision method. We propose a series of image processing techniques to extract the features efficiently from x-ray images, where the occluded features in case of normal camera vision could be found ...

  • PDF

CNT-BASED FIELD EMISSION X-RAY SOURCE

  • Kim, Hyun Suk;Lee, Choong Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.433-433
    • /
    • 2016
  • Carbon nanotubes (CNT) emitter has widely become an attractive mechanism that draws growing interests for cold cathode field emission. CNT yarns have demonstrated its potential as excellent field emitters. It was demonstrated that a small focal spot size was achieved by manipulating some electrical parameters, such as applied bias voltage at the mesh gate, and electrostatic focal lenses, geometrical parameters, such as axial distances of the anode, and the electrostatic focal lens from the cathode assembly, and the dimension of the opening of the electrostatic lens. Electrical-optics software was used to systematically investigate the behavior of the electron beam trajectory when the aforementioned variables were manipulated. The results of the experiment agree with the theoretical simulation results. Each variable has an individual effect on the electron beam focal spot size impinging on the target anode. An optimum condition of the parameters was obtained producing good quality of X-ray images. Also, MWCNT yarn was investigated for field emission characteristics and its contribution in the X-ray generation. The dry spinning method was used to fabricate MWCNT yarn from super MWCNTs, which was fabricated by MW-PECVD. The MWCNT yarn has a significant field emission capability in both diode and the triode X-ray generation structure compared to a MWCNT. The low-voltage-field emission of the MWCNT yarn can be attributed to the field enhancing effect of the yarn due to its shape and the contribution of the high-aspect-ratio nanotubes that protrude from the sides of the yarn. Observations of the use of filters on the development of X-ray images were also demonstrated. The amount of exposure time of the samples to the X-ray was also manipulated. The MWCNT yarn can be a good candidate for use in the low voltage field emission application of X-ray imaging.

  • PDF