• 제목/요약/키워드: X-Ray image

검색결과 1,268건 처리시간 0.123초

An Intraoral Miniature X-ray Tube Based on Carbon Nanotubes for Dental Radiography

  • Kim, Hyun Jin;Kim, Hyun Nam;Raza, Hamid Saeed;Park, Han Beom;Cho, Sung Oh
    • Nuclear Engineering and Technology
    • /
    • 제48권3호
    • /
    • pp.799-804
    • /
    • 2016
  • A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube.

어린이 성장판 영상화를 위한 초음파와 X-선 방식의 비교 평가 (Comparison Between Ultrasonic and X-ray Methods for Imaging the Children′s Growth Plate)

  • 김상후;김형준;한은옥;한승무
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권6호
    • /
    • pp.551-556
    • /
    • 2004
  • 본 연구에서는 진단 방법의 정확성이 아직까지 구체적으로 규명되지 않고 있는 어린이의 성장 발육을 체계적이고 과학적으로 측정할 수 있는 방법을 제시하고자 시도하였다. 현재 많이 이용되고 있는 성장 진단 방법은 X-ray 영상을 이용한 각 관절 부위의 성장판의 개폐 분석이다. 그러나 X-ray 방식은 성장 진단에서 요구되는 주기적이고 반복적인 측정을 하지 못함과 동시에 방사선 노출이라는 단점을 가지고 있다. 따라서 인체에 무해한 초음파 영상을 이용한 성장판 개폐 분석 대체 가능성을 평가하기 위해 종골의 초음파 광역 감쇄 영상을 이용한 프로파일 분석 및 성장판 영상 분석 알고리즘을 제시하였다. 본 연구에서는 7세~16세의 어린이 269명에 대해서 X-ray를 이용하여 무릎, 손가락, 종골에서의 성장판 영상을 얻었다. 또한 초음파 방식을 이용하여 종골의 성장판 영상을 얻었다. 각 관절에서의 성장판 개폐 유무 시기는 각 개인별로 측정 방법에 따라 조금의 차이는 있으나 전반적으로 일치하였다. 또한. X-ray방식과 초음파 방식에 의한 성장판 영상을 비교한 결과 상호 높은 연관성을 나타내었다. 이와 같이 성장판을 정확하게 측정하기 위해 도입된 초음파 프로파일 분석 알고리즘은 기존의 X-ray 영상 방식에 의한 성장판의 측정을 대체할 수 있을 것으로 사료된다.

The Performance Test of Anti-scattering X-ray Grid with Inclined Shielding Material by MCNP Code Simulation

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.111-115
    • /
    • 2016
  • Background: The scattered photons cause reduction of the contrast of radiographic image and it results in the degradation of the quality of the image. In order to acquire better quality image, an anti-scattering x-ray gird should be equipped in radiography system. Materials and Methods: The X-ray anti-scattering grid of the inclined type based on the hybrid concept for that of parallel and focused type was tested by MCNP code. The MCNPX 2.7.0 was used for the simulation based test. The geometry for the test was based on the IEC 60627 which was an international standard for diagnostic X-ray imaging equipment-Characteristics of general purpose and mammographic anti-scatter grids. Results and Discussion: The performance of grids with four inclined shielding material types was compared with that of the parallel type. The grid with completely tapered type the best performance where there were little performance difference according to the degree of inclination. Conclusion: It was shown that the grid of inclined type had better performance than that of parallel one.

퍼지를 이용한 X-ray 영상의 대비제한 적응 히스토그램 평활화 한계점 결정 (The Clip Limit Decision of Contrast Limited Adaptive Histogram Equalization for X-ray Images using Fuzzy Logic)

  • 조현지;계희원
    • 한국멀티미디어학회논문지
    • /
    • 제18권7호
    • /
    • pp.806-817
    • /
    • 2015
  • The contrast limited adaptive histogram equalization(CLAHE) is an advanced method for the histogram equalization which is a common contrast enhancement technique. The CLAHE divides the image into sections, and applies the contrast limited histogram equalization for each section. X-ray images can be classified into three areas: skin, bone, and air area. In clinical application, the interest area is limited to the skin or bone area depending on the diagnosis region. The CLAHE could deteriorate X-ray image quality because the CLAHE enhances the area which doesn't need to be enhanced. In this paper, we propose a new method which automatically determines the clip limit of CLAHE's parameter to improve X-ray image quality using fuzzy logic. We introduce fuzzy logic which is possible to determine clip limit proportional to the interest of users. Experimental results show that the proposed method improve images according to the user's preference by focusing on the subject.

X-선 투과검사를 이용한 저항 점용접부 품질평가기법 (Weld Quality Evaluation Method for the Resistance Spot Welds using X-ray Transmission Inspection)

  • 이종대;이소정;방정환;윤길상;김목순;김준기
    • Journal of Welding and Joining
    • /
    • 제32권6호
    • /
    • pp.1-7
    • /
    • 2014
  • For the resistance spot welds of CR1180 and GA1180 TRIP steels, the weld quality evaluation method using the digitalized X-ray transmission imaging apparatus was investigated in comparison with the crosssectional examination method. In the case of the resistance spot welding of CR1180, three circular regions, such as WZ(white zone), GZ(grey zone) and DZ(dark zone), appeared on X-ray image and they corresponded to the diameters of indentation mark, nugget and corona bond, respectively. The variation of X-ray transmission thickness due to the thickness variation of the weld seemed to be mainly responsible for the formation of those contrasts. The X-ray image contrast formed from the variation of transmission thickness at the outer border line of DZ could also enable the inspections of the notch shape, nonuniformity of the welding pressure and spatter from its sharpness, concentricity and the normal straight line, respectively. The X-ray image of the resistance spot weld of galvannealed GA1180 TRIP steel was very similar to that of CR1180 TRIP steel except the crown shaped outer border line of DZ which was considered to be due to the melting behavior of zinc having the boiling temperature even lower than the melting temperature of steel.

적응 양자화를 위한 의료 영상 정보의 변환 부호화에 관한 연구 (A Study Transform Coding of Medical Image Using Adaptive Quantization Method)

  • 한영오;박장춘
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권3호
    • /
    • pp.243-252
    • /
    • 1989
  • In this study, medical images, which are X-ray image and CT image, are compressed by the adam live coding technique. The medical images may be treated as special ones, because they are different from general images in many respects. The statistical characteristics that medical images only have in transform domain are analyzed, and then the improved quantization method is proposed for medical images. For chest X-ray image and CT head image, the better results are obtained by the improved adaptive coding technique.

  • PDF

퍼지 이론을 이용한 의료 영상 특징 추출에 관한 연구 (A study on segmentation of medical image using fuzzy set theory)

  • 김형석;한영오;박상희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.741-745
    • /
    • 1991
  • This paper describes a feature extraction in digitized chest X-ray image and CT head Image. There are Extraction, Thresholding, Region G rowing, Split-Merge and Relaxation in feature extraction technique. In this study, Region Growing System was realized and Fuzzy Set Theory was applied in order to extract the vague region which the conventional method has difficulties in extracting. The performance of proposed algorithm was proved by being applied to chest X-ray image and CT head image.

  • PDF

치과 영상용 삽입형 초소형 X선 튜브의 가능성 연구 (Feasibility study of insertable miniature x-ray source for dental imaging)

  • 조성호;김소영;안소현;임수미;이레나
    • 한국방사선학회논문지
    • /
    • 제6권1호
    • /
    • pp.39-45
    • /
    • 2012
  • 기존 구내 치근단 촬영용 장치는 환자 피폭선량, 촬영시 고통 등의 문제점을 지니고 있다. 본 연구에서는 이러한 문제점을 해결하기 위한 신개념의 삽입형 초소형 X선 시스템의 가능성을 검증하였다. 먼저 초소형 X선 튜브에 사용될 콜리메이터와 필터를 설계하기 위하여 Geant4를 이용하여 최적의 콜리메이터 두께와 필터 두께를 결정하였으며 CdTe 검출기와 PX4 모듈을 이용하여 결정된 두께에서의 X선 스펙트럼을 확인하였다. 또한 기존 상용화된 치근단 촬영장치와 XOFT사의 초소형 X선 튜브를 이용하여 제작된 치아 팬텀에 대한 영상을 획득하였다. 그 결과 제안된 신개념의 삽입형 초소형 X선 시스템은 기존 시스템과 유사한 영상의 질을 나타내었다. 이는 향후 치근단 촬영용 장치를 비롯하여 다양한 응용부위에 활용할 수 있음을 나타낸다.

Cobey 검사법과 Modified Cobey 검사법에 대한 방사선학적 연구 (Radiographic Study of Cobey Method and Modified Cobey Method)

  • 고유림;주영철;이승근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권3호
    • /
    • pp.167-173
    • /
    • 2019
  • The Cobey method and the modified Cobey method are most commonly used in clinical practice. Therefore, the purpose of this study was to investigate the radiological differences between Cobey and modified Cobey and provide radiographic information about changes of hindfoot image with X-ray entrance center and tube angle change in modified Cobey. This study was performed on foot and ankle phantom. First, for image comparison of Cobey and modified Cobey, the images obtained by applying the same X-ray entrance center to the ankle joint were compared and analyzed. Second, in the modified Cobey, the X-ray entrance center is set as ankle joint and lateral malleolus. The X-ray tube angle was varied from $10^{\circ}$ to $40^{\circ}$ at $5^{\circ}$ intervals for each X-ray entrance center. The images obtained by varying the X-ray tube angle from $10^{\circ}$ to $40^{\circ}$ at intervals of $5^{\circ}$ for each X-ray entrance center were compared and analyzed. The irradiation conditions were the same with 110 kVp, 200 mA, 10 ms, and 110 cm of source - image receptor distance (SID). Image evaluation was performed by two radiologists. Measurements were made on the lateral point, middle point, and calcaneus width based on a hypothetical line parallel to the calcaneal tuberosity. Data were analyzed by using descriptive statistics as the mean of the distance to each measurement location. The modified Cobey was longer than the Cobey by an average of 3 to 4 mm lateral and medial points, and the calcaneus width was similar (ICC = 0.939). In modified Cobey method, when the X-ray entrance center is ankle joint, the lateral point is about 3 mm and the medial point is about 4.3 mm longer than lateral malleolus. Also, when the X-ray tube angle is more than $20^{\circ}$, the degree of distortion is large. The ICCs for the lateral, medial point, and calcaneus width were 0.998, 0.961, and 0.997, respectively, as the X-ray entrance center and tube angle were changed. There was no significant difference between Modified Cobey and Cobey. Modified Cobey showed no need to compensate the $20^{\circ}$ detector angle of the Cobey. In addition, we suggest that tube angle should be limited within $20^{\circ}$ when modified Cobey is performed.

진단용 X-선 스펙트럼의 몬테칼로 전산모사 측정 (Diagnostic X-ray Spectra Detection by Monte Carlo Simulation)

  • 백철하;이승재;김대홍
    • 한국방사선학회논문지
    • /
    • 제12권3호
    • /
    • pp.289-295
    • /
    • 2018
  • 대부분의 진단용 방사선 장치는 엑스선을 사용하며, 엑스선은 다양한 에너지를 갖는 스펙트럼을 갖는다. 진단 영상에서 엑스선의 정량적 및 정성적 분석은 선량을 줄이면서 영상 화질을 유지하는데 필수적이다. 본 연구의 목적은 진단 영상에 사용되는 엑스선 스펙트럼을 몬테칼로 시뮬레이션으로 측정하는 것이다. 다양한 엑스선 에너지 스펙트럼이 몬테칼로 시뮬레이션으로 측정되었다. 이 스펙트럼들은 다항식을 보간 한 양극 텅스텐 모델에 의해 계산된 결과와 비교하였다. 엑스선 관전압은 50, 60, 80, 100, 110 kV 였다. 검출기로는 카드뮴 텔루라이드와 비정질 셀레늄 물질을 사용하였다. 엑스선 에너지 스펙트럼의 시뮬레이션 결과는 참조 결과와 일치하였고, NRMSD 값은 최소 1.1%에서 최대 5.7%를 보였다. 시뮬레이션 결과에 의하면 진단 영상을 획득할 때 적절한 관전압의 선택을 가능하게 할 것이다. 또한, 영상 획득 전 환자에 전달되는 선량을 예측하는데 기여할 것이다.