• Title/Summary/Keyword: X-Ray Film

Search Result 2,292, Processing Time 0.031 seconds

The Comparative Analysis of Exposure Conditions between F/S and C/R System for an Ideal Image in Simple Abdomen (복부 단순촬영의 이상적 영상구현을 위한 F. S system과 C.R system의 촬영조건 비교분석)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Je-Bong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • 1. Purpose : This study is to present effective exposure conditions to acquire the best image of simple abdomen in Film Screen (F.S) system and Computed Radiography (C.R) system. 2. Method : In the F.S system, while an exposure condition was fixed as 70kVp, images of a patients simple abdomen were taken under the different mAs exposure conditions. Among these images, the best one was chosen by radiologists and radiological technologists. In the C.R system, the best image of the same patient was acquired with the same method from the F.S system. Both characteristic curves from F.S system and C.R system were analyzed. 3. Results : In the F.S system, the best exposure condition of simple abdomen was 70kVp and 20mAs. In the CR system, with the fixed condition at 70kVp, the image densities of human organs, such as liver, kidney, spleen, psoas muscle, lumbar spine body and iliac crest, were almost same despite different environments (3.2mAs, 8mAs, 12mAs, 16mAs and 20mAs). However, when the exposure conditions were over or under (below) 12mAs, the images between the abdominal wall and the directly exposed part became blurred because the gap of density was decreased. In the C.R system, while the volume of mAs was decreased, an artifact of quantum mottle was increased. 4. Conclusion : This study shows that the exposure condition in the C.R system can be reduced 40% than in the F.S system. This paper concluded that when the exposure conditions are set in CR environment, after the analysis of equipment character, such as image processing system(EDR : Exposure Data Recognition processing), PACS and so on, the high quality of image with maximum information can be acquired with a minimum exposure dose.

  • PDF

Magnetic and Electric Transport Properties of MnTe Thin Film Grown by Molecular Beam Epitaxy (분자선 증착법에 의해 성장한 MnTe 박막의 자기적 및 전기수송 특성)

  • Kim, Woo-Chul;Bae, Sung-Whan;Kim, Sam-Jin;Kim, Chul-Sung;Kim, Kwang-Joo;Yoon, Jung-Bum;Jung, Myung-Hwa
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.2
    • /
    • pp.81-85
    • /
    • 2007
  • MnTe layers of high crystalline quality were successfully grown on Si(100) : B and Si(111) substrates by molecular beam epitaxy (MBE). Under tellurium-rich condition and the substrate temperature around $400^{\circ}C$, a layer thickness of $700{\AA}$ could be easily obtained with the growth rate of $1.1 {\AA}/s$. We investigated the structural, magnetic and transport properties of MnTe layers by using x-ray diffraction (XRD), superconducting quantum interference device (SQUID) magnetometry, and physical properties measurement system (PPMS). Characterization of MnTe layers on Si(100) : B and Si(111) substrates by XRD revealed a hexagonal structure of polycrystals with lattice parameters, ${\alpha}=4.143{\pm}0.001{\AA}\;and\;c=6.707{\pm}0.001{\AA}$. Investigation of magnetic and transport properties of MnTe films showed anomalies unlike antiferromagnetic powder MnTe. The temperature dependence of the magnetization data taken in zero-field-tooling (ZFC) and field-cooling (FC) conditions indicates three magnetic transitions at around 21, 49, and 210 K as well as the great irreversibility between ZFC and FC magnetization in the films. These anomalies are attributable to a magnetic-elastic coupling in the films. Magnetization measurements indicate ferromagnetic behaviour with hysteresis loops at 5 and 300 K for MnTe polycrystalline film. The coercivity ($H_c$) values at 5 and 300 K are 55 and 44 Oe, respectively. In electro-transport measurements, the temperature dependence of resistivity revealed a noticeable semiconducting behaviours and showed conduction via Mott variable range hopping at low temperatures.

Electrochemical Characteristics of Dental Implant in the Various Simulated Body Fluid and Artificial Saliva (다양한 유사체액과 인공타액에서 치과용 임플란트의 전기화학적 특성)

  • Kim, T.H.;Park, G.H.;Son, M.K.;Kim, W.G.;Jang, S.H.;Choe, H.C.
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.5
    • /
    • pp.226-231
    • /
    • 2008
  • Titanium and its alloy have been widely used in dental implant and orthopedic prostheses. Electrochemical characteristics of dental implant in the various simulated body fluids have been researched by using electrochemical methods. Ti-6Al-4V alloy implant was used for corrosion test in 0.9% NaCl, artificial saliva and simulated body fluids. The surface morphology was observed using scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX). The electrochemical stability was investigated using potentiosat (EG&G Co, 263A). The corrosion surface was observed using scanning electron microscopy (SEM). From the results of potentiodynamic test in various solution, the current density of implant tested in SBF and AS solution was lower than that of implant tested in 0.9% NaCl solution. From the results of passive film stability test, the variation of current density at constant 250 mV showed the consistent with time in the case of implant tested in SBF and AS solution, whereas, the current density at constant 250mV in the case of implant tested in 0.9% NaCl solution showed higher compared to SBF and AS solution as time increased. From the results of cyclic potentiodynamic test, the pitting potential and |$E_{pit}\;-\;E_{corr}$| of implant tested in SBF and AS solution were higher than those of implant tested in 0.9% NaCl solution.

Growth of $CdGa_2Se_4$ epilayer using hot wall epitaxy method and their photoconductive characteristics (HWE에 의한 $CdGa_2Se_4$ 박막 성장과 광전도 특성)

  • 홍광준;이관교;이상열;유상하;신용진;서상석;정준우;정경아;신영진
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.3
    • /
    • pp.366-376
    • /
    • 1997
  • $CdGa_2Se_4$, epilayer of tetragonal type are grown on Si(100) substrate by hot wall epitaxy method. The source and substrate temperature is $580^{\circ}C$ and $420^{\circ}C$ respectively, and the thickness of the film is 3 $\mu \textrm{m}$. The crystallihe structure of epilayers were investigated by double crystal X-ray diffraction(DCXD). Hall effect on this sample was measured by the method of van der Pauw and studied on carrier density and mobility depending on temperature. From Hall data, the mobility was likely to be decreased by pizoelectric scattering in the temperature range 30 K to 200 K and by polar optical scattering in the temperature range 200 K to 293 K. In order to explore of photocurrent to darkcurrent (pc/dc), maximum allowable power dissipation (MAPD), spectral response and response time. The results indicated that for the samples annealed in Se vapor the photoconductive characteristics are best. Then we obtained the sensitivity of 0.98, the value of pc/dc of $9.62{\times}10^6$, the MAPD of 321 ㎽ and the rise and decay time of 9 ㎳ and 9.5 ㎳, respectively.

  • PDF

Statistical Study of the Ferguson's Angle, Lumbar Gravity Line and Lumbar Lordotic Angle in HIVD Patients. (요추간판탈출증 환자의 요천각, 요추중력중심선 및 요추전만각의 통계적 관찰)

  • Koh, Dong-Hyun;Hong, Soon-Sung;Lee, Jin-Ho;Jung, Sung-Yub;Shin, Joon-Shik
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.2 no.2
    • /
    • pp.17-32
    • /
    • 2007
  • Objectives : The lumbosacral joint is unstable area from an anatomical viewpoint, while it is also a very mobile area in ordinary life, so that clinically major causes of low back pain originate in this joint. The purpose of this study is to assess the difference of the Ferguson's angles, Lumbar gravity lines, Lumbar lordotic angles among Herniated of Intervertebral Disc(HIVD) patients. Methods : We analyzed the lateral view of lumbar spine checked at erect position on 88 patients who had been diagnosed as HIVD by Magnetic Resonance Imaging(MRI). We investigated the Ferguson's angle, Lumbar gravity line, Lumbar lordotic angle on X-ray film. Results and Conclusions : In the acute lumbago group the Ferguson's angle had a tendency to decrease, while in the chronic group it had a tendency to increase. In the acute lumbago group the Lumbar gravity line fell in front of the normal range(sacrum), while in the chronic group it fell behind the normal range(sacrum). In the acute lumbago group the Lumbar lordotic angle usually decreased, while in the chronic group it increased. The Ferguson's angle and the Lumbar gravity line, the Ferguson's angle and the Lumbar lordotic angle, the Lumbar gravity line and Lumbar lordotic angle each had a positive realtionship. The Ferguson's angle, the Lumbar gravity line and the Lumbar lordotic angle was less influenced by the level of HIVD and was more influenced by how long the patient had the pain. The correlationship between each factor was less in the chronic lumbago group than the acute group. In the chronic lumbago group the instability of the lumbosacral joint increased, while in the acute group the compression of the weight on the sacrum increased.

  • PDF

Effect of Photodynamic Therapy in Lung Cancer (폐암에서 광역동치료술의 효과)

  • Yoon, Sung Ho;Han, Kyung Taek;Kim, Gyung Nam;Lee, Seung Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.4
    • /
    • pp.358-363
    • /
    • 2004
  • Background : Photodynamic therapy (PDT) involves the use of photosensitizing agents for treatment of malignant disease. PDT is approved by the U.S. Food and Drug Administration for the endobronchial microinvasive nonsmall cell lung cancer and for palliation in patients with obstructing tumors. We report our experience and results of PDT in lung cancer. Method : Ten patients with lung cancer who were diagnosed in Chosun university hospital by histologic confirm through bronchoscopy were included between August 2002 and May 2003. The photosensitizer (Photogem$^{(R)}$, Lomonosov institute of Fine Chemical, Russia/dose 2.0 mg/kg body weight) was injected 48 hours prior to the PDT session. For PDT with the photosensitizer (Photogem$^{(R)}$), Diode LASER system (Biolitec Inc., Germany, wavelength; 633nm) were used. PDTs were done at 48-72 hours after photogem injection. Follow up bronchoscopy and chest X-ray or thorax computerized tomography were done for evaluate PDT response. Results : 9 of 10 patients with endobronchial obstruction showed partial remission with bronchus opening after PDT. Direct reaction of the tumor to PDT was similar in despite of its localization. It was as follows; edema, hyperemia, in-situ bleeding, fibrin film occurrence. Any other complications such as sunburns of skin, inflammation within the PDT zone were not occurred by the end of the fourth week. Conclusion : In the advanced endobronchial disease, PDT has been shown to be useful in treating endobronchial tumors that are causing clinically significant dyspnea or are likely to progress and lead to further clinical complications, such as postobstructive pneumonia.

Electrochemical treatment of wastewater using boron doped diamond electrode by metal inter layer

  • KIM, Seohan;YOU, Miyoung;SONG, Pungkeun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.251-251
    • /
    • 2016
  • For several decades, industrial processes consume a huge amount of raw water for various objects that consequently results in the generation of large amounts of wastewater. Wastewaters are consisting of complex mixture of different inorganic and organic compounds and some of them can be toxic, hazardous and hard to degrade. These effluents are mainly treated by conventional technologies such are aerobic and anaerobic treatment and chemical coagulation. But, these processes are not suitable for eliminating all hazardous chemical compounds form wastewater and generate a large amount of toxic sludge. Therefore, other processes have been studied and applied together with these techniques to enhance purification results. These include photocatalysis, absorption, advanced oxidation processes, and ozonation, but also have their own drawbacks. In recent years, electrochemical techniques have received attention as wastewater treatment process that could be show higher purification results. Among them, boron doped diamond (BDD) attract attention as electrochemical electrode due to good chemical and electrochemical stability, long lifetime and wide potential window that necessary properties for anode electrode. So, there are many researches about high quality BDD on Nb, Ta, W and Si substrates, but, their application in effluents treatment is not suitable due to high cost of metal and low conductivity of Si. To solve these problems, Ti has been candidate as substrate in consideration of cost and property. But there are adhesion issues that must be overcome to apply Ti as BDD substrate. Al, Cu, Ti and Nb thin films were deposited on Ti substrate to improve adhesion between substrate and BDD thin film. In this paper, BDD films were deposited by hot filament chemical vapor deposition (HF-CVD) method. Prior to deposition, cleaning processes were conducted in acetone, ethanol, and isopropyl alcohol (IPA) using sonification machine for 7 min, respectively. And metal layer with the thickness of 200 nm were deposited by DC magnetron sputtering (DCMS). To analyze microstructure X-ray diffraction (XRD, Bruker gads) and field emission scanning electron microscopy (FE-SEM, Hitachi) were used. It is confirmed that metal layer was effective to adhesion property and improved electrode property. Electrochemical measurements were carried out in a three electrode electrochemical cell containing a 0.5 % H2SO4 in deionized water. As a result, it is confirmed that metal inter layer heavily effect on BDD property by improving adhesion property due to suppressing formation of titanium carbide.

  • PDF

Relation between Tuffier's Line and Spondylolisthesis (척추전방전위증과 Tuffier's line 높이와의 상관관계)

  • Kim, Han-Kyum;Hong, Soon-Sung;Yom, Sun-Kyu;Jin, Eun-Seok;Jung, Hae-Chan
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.3 no.2
    • /
    • pp.37-42
    • /
    • 2008
  • Objectives : One of the most important cause of spondylolisthesis is it's epidemiological structure and L5's stability takes a significant role. The purpose of this study is to assess the difference of the Tuffier's line among of Spondylolythesis patients. Methods : We analyzed the Anterior view of lumbar spine checked at erect position on 60 patients who had been diagnosed as spondylolythesis. We investigated the Tuffier's Line on X-ray film. Results and Conclusions : Age distribution was 15 to 66 and the average was 47.81. Men were 19 cases(31.6%) and women were 41 cases(68.4%). Compared to men, women were more exposed to spondylolisthesis and for the age distribution, 50's showed the biggest portion. Group of normal people showed proportion of 14.3% at L4, 44% at L4/5 and 41.7% at L5 each. And group of patients showed proportion of 48.4% at L4, 35% at L4/5 and 51.6% at L5 each. Comparing these results, significance probability was 0.004(<0.05) which was significant. As the results of comparing the relation between L4/5 and L5/S1 patients, Normal group showed average of 3.33 which were close to L4/5. When there are spondylolisthesis at L4/5, averege was 3.33, placed at lower part of the vertebra body. When there are spondylolisthesis at L5/S1, averege was 3.566, placed between lower part of the veterbra body of L4 and L4/5. The p value of Normal group and L4/5 spondylolisthesis patient group was 0.022(p<0.05) which was significant. But the p value of Normal group and L5/S1 spondylolisthesis patient group was 0.0239 which was not significant. Also p value of L4/5 spcndylolisthesis patient group and L5/S1 spondylolisthesis patient group was 0.721 which was also not significant.

  • PDF

Study of etching properties of the $HfAlO_3$ thin film using the inductively coupled plasma (유도결합 플라즈마를 이용한 $HfAlO_3$ 박막의 식각특성 연구)

  • Ha, Tae-Kyung;Kim, Dong-Pyo;Woo, Jong-Chang;Um, Doo-Seung;Yang, Xue;Joo, Young-Hee;Kim, Chang-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.73-73
    • /
    • 2009
  • 트렌지스터의 채널 길이가 줄어듦에 따라 절연층으로 쓰이는 $SiO_2$의 두께는 얇아져야 한다. 이에 따라 얇아진 절연층에서 터널링이 발생하여 누설전류가 증가하게 되어 소자의 오동작을 유발한다. 절연층에서의 터널링을 줄여주기 위해서는 High-K와 같은 유전율이 높은 물질을 이용하여 절연층의 두께를 높여주어야 한다. 최근에 각광 받고 있는 High-K의 대표적인 물질은 $HfO_2$, $ZrO_2$$Al_2O_3$등이 있다. $HfO_2$, $ZrO_2$$Al_2O_3$$SiO_2$보다 유전상 수는 높지만 밴드갭 에너지, 열역학적 안정성, 재결정 온도와 같은 특성 면에서 $SiO_2$를 완전히 대체하기는 어려운 실정이다. 최근 연구에 따르면 기존의 High-K물질에 금속을 첨가한 금속산화물의 경우 밴드갭 에너지, 열역학적 안정성, 재결정 온도의 특성이 향상되었다는 결과가 있다. 이 금속 산화물 중 $HfAlO_3$가 대표적이다. $HfAlO_3$는 유전상수 18.2, 밴드캡 에너지 6.5 eV, 재결정 온도 $900\;^{\circ}C$이고 열역학적 안전성이 개선되었다. 게이트 절연층으로 사용될 수 있는 $HfAlO_3$는 전극과 기판사이에 적층구조를 이루고 있어, 이방성 식각인 건식 식각에 대한 연구가 필요하다. 본 연구는 $BCl_3$/Ar 유도결합 플라즈마를 이용하여 $HfAlO_3$ 박막의 식각 특성을 알아보았다. RF Power 700 W, DC-bias -150 V, 공정압력 15 mTorr, 기판온도 $40\;^{\circ}C$를 기본 조건으로 하여, $BCl_3$/Ar 가스비율, RF Power, DC-bias 전압, 공정압력에 의한 식각율 조건과 마스크물질과의 선택비를 알아보았다. 플라즈마 분석은 Optical 이용하여 진행하였고, 식각 후 표면의 화학적 구조는 X-ray Photoelectron Spectroscoopy(XPS) 분석을 통하여 알아보았다.

  • PDF

A Case of Interstitial Pneumonitis developed by Interferon-${\alpha}$ Treatment for Chronic Hepatitis C (만성 C형 간염 환자에서 Interferon-${\alpha}$를 투여중 발생한 간질성 폐렴 1예)

  • Yoon, Jong Goo;Ahn, Joong Hyun;Ko, Seung Hyeon;Lee, Hyun Seoung;Kwon, Soon Seog;Kim, Young Kyoon;Moon, Hwa Sik;Park, Sung Hak;Song, Jeong Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.637-644
    • /
    • 1996
  • Interstitial pneumonitis associated with interferon alpha therapy for chronic hepatitis C was first describe6 in 1994 by Kazoo et al In Japan. The mechanism of interstitial pneumonitis developed by interferon alpha was still unknown but immunologic, allergic of direct lung toxicity were suggested. We experienced a case of interstitial pneumonitis developed during interferon alpha therapy for chronic hepatitis C in a 52-year-old male patient. He was treated with 6 million units of interferon alpha intramuscularly 3 times per week for 4 weeks and noted progressive dyspnea and cough. These symptoms were subsided after 6 weeks' discontinuation of interferon alpha therapy. And so, he was retreated with 3 million units of interferon alpha 3 times per week for 8 weeks and felt dyspnea again. He was admitted to our hospital for further evaluation of progressive dyspnea. Arterial blood gas(ABG) values were $PaO_2$ 90.7 mmHg and $PaCO_2$ 31.9 mmHg, and antinuclear antibody(ANA) was negative. A chest X-ray film revealed diffuse reticulo-nodular shadows in bilateral lung fields, suggesting a diagnosis of interstitial pneumonitis. A marked increase in lymphocyte count and suppressor T cell were observed in bronchoalveolar lavage(BAL) fluid. Lymphocyte stimulation test with interferon alpha was positive. Interstitial pneumonitis was confirmed by transbronchial lung biopsy. After discontinuation of interferon alpha, we gave oral steroid in the condition that clinical symptoms were being improved gradually.

  • PDF