• Title/Summary/Keyword: X-축 이동

Search Result 93, Processing Time 0.026 seconds

Development of high-precision 2-axis translation system comprised of microstage and global stage (Microstage와 global stage를 결합한 초정밀 2축 이동장치 개발)

  • 김종윤;엄태봉
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.311-314
    • /
    • 1997
  • According to the development of industrial equipment such as semiconductor manufacturing machines, optical device, and precision machine tool, a high-precision translation system with wide range has been required. This paper describes a high-precision 2-axis translation system, which consists of microstage and global stage. In order to achieve the highresolution in the long range, some engineering techniques are used. Three linear guides with flexible coupling are adopted to reduce the motor vibration in the global stage. A simple elastic hinge structure activated by five PZT is applied to reduce the angular dev~atlon. As the result of combination of microstage and global stage associated with some engineering techniques, the 2-axis translation system can measure the 200 X 200 mrn range with the nanometer accuracy.

  • PDF

X-ray Radiography에 적합한 Double Multilayer Monochromaotr (DMM) 설계와 제작

  • Jeong, Sun-Yong;Yang, Seong-Seon;Im, Jae-Hong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.118-118
    • /
    • 2013
  • DMM은 방사광가속기의 백색광으로부터 단색광을 추출하기 위해 두 개의 다층 박막 (multilayer) 거울을 사용하는데, 첫 번째 거울은 Bragg 반사를 통해 분광을 하여 단색광을 생산하는 용도이고, 두 번째 거울은 이 단색광을 반사시켜 지면과 평행하게 출사되게 하기 위함이다. 일반적으로 사용되는 DCM (Double Crystal Monochromator)과의 차이점은, Bragg 반사를 위해 DCM에서는 결정을 사용하는 반면 DMM은 밀도차이가 많이나는 두 종류의 물질을 교대로 쌓아 올린 다층 박막을 사용한다는 것이다. 다층 박막의 주기가 곧 Bragg 반사에서의 d-spacing이 되며, X-선 분광의 목적으로 사용되는 d-spacing은 10-50 $\AA$ 사이이다. DCM이 0.01% 대의 우수한 에너지 분해능을 보이는데 비해, DMM은 1% 정도이다. 이 때문에 출사광의 밝기가 DCM에 비해 100배 밝은 특징이 있어서 에너지 분해능보다 광량이 더 중요한 응용에서 DMM이 사용된다. X-선 영상이나 방사선치료가 바로 이러한 응용에 해당한다. DMM은 포항가속기연구소와 (주) 벡트론에서 공동 설계하였으며, (주)벡트론에서 제작하였다. 그림 1에 DMM의 외형과 내부 구조를 나타내었다. Bragg 각의 조절 범위는 0.24-0.9도 이다. 입사광과 출사광의 수직 방향 offset을 10 mm로 유지하기 위해 두 번째 다층 박막이 수평방향으로 1,000 mm 가량 이동할 수 있어야 한다. 이를 위해 두 대의 고니오미터 stage를 사용하여 각각 첫 번째 및 두 번째 다층 박막의 위치와 방향을 제어한다. 첫 번째 다층 박막을 제어하는 고니오미터 stage는 하부가 전체 프레임에 고정되어 있고, 이 고니오미터의 회전축에서 Bragg 각을 조절한다. 두 번째 다층 박막을 제어하는 고니오미터 stage는 높이방향과 수평방향으로 이동이 가능하다. 다층 박막의 pitch는 고니오미터의 회전축에서 조절한다. 그리고 tilt stage를 사용하여 다층 박막의 roll을 조절한다.

  • PDF

2축 로드셀 기반 스크레치테스터의 제작 및 평가

  • 이정일;김종호;이효직;오희근;박연규;강대임
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.170-170
    • /
    • 2004
  • 박막의 접착강도를 측정하기 위하여 수직력과 수평력을 동시에 측정할 수 있는 0.1∼100 N 용량의 2축 로드셀에 기반을 둔 스크레치 테스터를 개발하였다. 반도체용 Si wafer 기판 위에 Au나 Al 등의 금속이 관은 박막으로 증착된 제품을 table에 고정시킨 후, 2축 로드셀(x, z)이 장착된 하중센서의 선단에 Diamond Tip을 장착하여 기판과 박막에 하중(z-axis)을 증가시키면서 동시에 wafer를 x축 방향으로 이동시킨다. 이런 방식으로 시료의 표면을 긁으면 박막이 벗겨져 나가 Diamond Tip이 기판에 닿을 때 서로 다른 경도차에 의해 진동이 발생하게 되고, 이 진동을 Acoustic Emission 센서에서 감지하여 Crack 발생 시점의 Load와 Stroke를 찾아내게 된다.(중략)

  • PDF

A Study on the Characteristics of Therapy Radiation Detector with Diode (다이오드를 이용한 치료방사선 검출기의 특성에 관한 연구)

  • 이동훈;지영훈
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.129-138
    • /
    • 1995
  • High-energy and high-dose X-ray and electron beam have been used in radiation therapy after developing particle accelerators. It is recommended to irradiate patients exect real dose for improving therapy effectiveness by International Committee on Radiation Units and Measurement. The radiation detector for daily beam checks of medical accelerators is described. Using thirteen silicon diodes, we have designed the diode detector providing information about calibration, beam symmetry, flatness, stability variation according to radiation damage, time and general quality assurance for both photon and eletron beams. we also compared these measurement values with those of using ionization chamber, film and semiconductor dosimeter.

  • PDF

A Study on the Magnetic Properties of Polycrystailine${(Fe,In,Eu)}_2O_3$ (다결정${(Fe,In,Eu)}_2O_3$계의 자기적 성질에 관한 연구)

  • 김정기;서정철;한은주;홍양기
    • Journal of the Korean Magnetics Society
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 1991
  • The magnetic properties of the polycrystalline ${(Fe_{2}O_{3})}_{1-x-y}{(In_{2}O_{3})}_{x}{(Eu_{2}O_{3})}_{y}$(x=0.01, y=0.02과 x=0.02, y=0.03) have been studied by the methods of X-ray diffraction, $M\"{o}ssbauer$ effect, and magnetic hysteresis measurement. The X-ray diffraction patterns show that the samples have a same crystal structure as $\alpha-Fe_{2}O_{3}$. From the analysis of the temperature dependence of the quadrupole splitting and average half-width, it is found that the Morin transition occurs in the sample of x=0.01 and y=0.02 and the spin angle defined as the angle between the [111] crystal axis and antiferromagnetic vector, changes from about $35^{\circ}$ to the (111) plane as increasing the temperature in the sample of x=0.02 and y=O.03. The temperature dependence of magnetic hyperfine field is analyzed by using the spin-wave theory. The isomer shift values at room temperature are found to be given by about 0.35mm/s for the samples which means that the Fe ions belong to $3^{+}ion$. The temperature dependence of isomer shift was analyzed by using the Debye model.

  • PDF

Comparison of plantar pressure and COP parameters in three types of arch support insole during stair descent in elderly with flatfoot (편평족 노인의 계단 하강 보행 시 아치 지지형 인솔 종류에 따른 족저압력 및 균형성 평가)

  • Han, Ki-Hoon;Bae, Kang-Ho;Jung, Ha-gon;Ha, Min-Sung;Choi, Do-Yeol;Lee, Joong-Sook;Yang, Jeong-Ok
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.948-955
    • /
    • 2018
  • The purpose of this study was to compare plantar pressure and COP parameters in three types of arch support insole during stair descent in elderly with flatfoot. A total of 14 women elderly were recruited for this study. Pedar-X was used to obtain plantar pressure(peak pressure, mean pressure, and contact area) and COP(distance, displacement, excursion) parameters. One-way ANOVAs were used to compare peak pressure, mean pressure, and contact area, distance of COP, displacement of COP, and excursion of COP. Among the plantar pressure parameters, significant(p<0.05) differences were observed in M3 for the peak pressure, M2, M3, and M4 for the mean pressure, and M2, M3, and M6 for the contact area. Among the COP parameters, distances of COP both in the mediolateral and anteroposterior axes revealed significant(p<0.05) differences. The larger peak pressure values of type A and B insoles were observed as compared to normal insole. The larger peak pressure and shorter COP distance values of type A and B insoles were observed as compared to normal insole.

AN EXPERIMENTAL STUDY ON THE STRESS DISTRIBUTION IN THE PERIODONTAL LIGAMENT (치주인대의 응력 분포 양상에 관한 실험 연구)

  • Choy, Kwang-Chul;Kim, Kyung-Ho;Park, Young-Chel;Han, Jung-Yun
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.15-24
    • /
    • 2001
  • In order to achieve a desirable tooth movement, it is of great importance to control the M/F ratio and to know the location of the center of resistance. The purpose of this study was to locate the center of resistance and the axis of rotation, and to estimate the stress distribution in the periodontal ligament with experimental model. After preparing a model of an upper canine with a simulated periodontal ligament and alveolar bone, the force and moment were applied. The tooth movement was traced using measuring device with LVDTs(Linear variable differential transformers) that can measure three dimensional tooth movement in real time. The results were as follows. 1. The location of center of resistance by transverse force was $29\%$ of root length measured from alveolar crest to apex regardless of force magnitude. The position of the center of resistance is more coronal than that of two-dimensional model($42\%$). 2. The center of resistance and the axis of rotation coincide when couple moment was applied. 3. As the magnitude of moment increases, tooth tends to extrude irrespective of the direction of the moment. 4. The relationship between location of force and axis of rotation (a x b = $49.6\;mm^2$) was obtained. A tooth movement can be predicted through this formula. 5. The centers of rotation by transverse force were plotted linearly.

  • PDF

A Conceptual Framework of the U.S. Suburbanization (미국 교외화에 대한 고찰과 개념적 분석틀)

  • ;Adrian X. Esparza
    • Proceedings of the KGS Conference
    • /
    • 2004.05a
    • /
    • pp.87-87
    • /
    • 2004
  • 미국 교외화에 관한 전통적인 접근의 한 축인 natural evolution 이론에서는 교외화의 요인으로서 소득증가와 교외지역 단독주택(single-family detached housing)에 대한 수요 증가, 자동차의 대중화로 인한 주택수요자의 공간이동성 증가, 주택소유 장려와 고속도로 건설 등의 미국 연방정부의 각종 정책, 그리고 교외주택의 대량생산에 따른 주택소유 비용의 하락을 강조해왔다. (중략)

  • PDF

XY Recording (XY Recorder에 있어 Noise)

  • 김은배
    • 전기의세계
    • /
    • v.20 no.5
    • /
    • pp.40-42
    • /
    • 1971
  • XY recorder는 10여년전부터 널리사용되어 오는 기록계로 2개의 자동평형전위차계로 X, Y축방향에 arm과 pen의 결합으로 양자의 좌표축의 교점에서 pen이 평형정지하는 상태에 기록지자체가 servo motor로 이동되어 기록이 가능하게 된다. 특히 타기록계에 비하여 고감도(Ex. 0.5V/cm), 고정도(Ex. 0.3%)임은 물론 y=f(x)인 x,y의 함수관계가 기록되어 타기록계에서는 얻기 어려운 특징이 있어, analog computer의 해의 기록계로서, 도한 각종 검출변환기를 전설치하여 vacuum tube 혹은 diode transistor의 특성곡선, 전기철판등의 자성재료의 자화곡선, 회전기의 회전수-전압, 전류, 출력, 효율곡선, 금속재료의 온도 혹은 인신장곡선, pipe valve의 유량-압력곡선등 전기.전지.기계.재료.물리.화학등의 다각도용도로서 연구실험은 물론 생산현장에 있어서의 시험. 정리. 감시등의 치용이 활발히 급진하는 경향에 비추어 이 기록계 사용에 고려되어야할 noise제거의 한 방법을 소개하고저 한다.

  • PDF

Effect of NiO Addition on Dielectric Properties of BaTiO3 Ceramics (NiO 첨가가 BaTiO3 세라믹스의 유전특성에 미치는 영향)

  • 김윤호
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.1 no.2
    • /
    • pp.105-112
    • /
    • 1994
  • BaTiO3 의 B-site에 0-0.03 몰 범위의 NiO를 첨가한 Ba1-xSrxTi1-y-wNiyZrwO3-y 유전 체에서 NiO 첨가가 유전특성 및 절연저항의 내환원성에 미치는 영향을 조사하였다. B-site Ni 치환에 의해 a 축의 격자상수는 증가하고 c 축의 격자상수는 감소하여 정방성 c/a가 감 소하였으며 단위격자의 부피는 증가하였다. NiO 첨가에 따라 큐리온도는 저온으로 이동하 였으며 큐리온도의 변화율은 소결분위기에 영향을 받았다. NiO가 첨가되지 않은 조성에서 는 산소분압 109 MPa의 환원분위기 소성에 의해 비정항이 107$\Omega$.cm로 저하되었으나 0.01 몰이상의 NiO를 첨가한 조성에서는 공기중 소결시 얻을수 있었던 1011$\Omega$.cm로 저하되었으 나 0.01 몰 이상의 NiO를 첨가한 조성에서는 공기중 소결시 얻을 수 있었던 1011$\Omega$.cm 이 상의 비저항을 유지하였다.