Speckle Reduction based on Neuro-Fuzzy Technique (뉴로-퍼지를 이용한 스펙클 제거)

  • Kil, Se-Kee;Jeon, Yu-Yong;Oh, Hyung-Seok;Nishimura, Toshihiro;Kwon, Jang-Woo;Lee, Sang-Min
    • Journal of IKEEE
    • /
    • v.12 no.3
    • /
    • pp.158-166
    • /
    • 2008
  • Medical ultrasound has benefits in mobility and safety than any other medical techniques such as X-ray, CT and MRI but has speckle noise which decrease the ability of an observer to distinguish the fine details in diagnostic examination. But simple removing of speckle often causes losing boundary information. Then, in this paper, we presented a novel neuro-fuzzy method which could remove speckle efficiently without loss of boundary information. Proposed method consists of image clustering by fuzzy algorithm and image processingby neural networks which was learned by back propagation. From the experiments for simulation image and real ultrasound image, we could verify the proposed method.

  • PDF

Three Dimensional Dose Planning Using 6MV X-ray and Multiaxial Computed Tomography for Pituitary Adenoma (6MV X-선과 전산화 단층 촬영상을 이용한 뇌하수체 종양 치료계획)

  • Lee, Myung-Za;Choi, Tae-Jin
    • Radiation Oncology Journal
    • /
    • v.3 no.1
    • /
    • pp.59-64
    • /
    • 1985
  • Computation of three dimensional dose distribution using CT image and RT plan was applied to a case of pituitary adenoma. Algorithm was based on two dimensional Tissue Maximun Ratio model extended to the third dimension. The resulting isodose curve of transeverse, coronal and sagittal section was demonstrated. This RT plan allows computation of dose distribution in any arbitarily defined plane in addition to conventional cross sectional view.

  • PDF

High Resolution Computerized Tomography System Using the Microfocus X-Ray for Inspection of Small Specimens (소형 물체의 검사를 위한 고해상도 미세 초점 X선 단층 촬영 시스템)

  • Kim, Young-Joo;Koo, Ja-Yong;Lee, Seung-S.;Kim, Whan-W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.3
    • /
    • pp.181-190
    • /
    • 1998
  • A computerized tomography system was developed using the X-ray source that has diameter of 5 micrometer. The system is used for the nondestructive testing of specimens with diameter below 20 mm. The convolution back projection algorithm was adopted for the reconstruction of cross sectional image, and the shape of the X-ray beam was let parallel beam or fan beam to compare each resultant image. Our CT system was constructed to operate based on the personal computer. The sectional images of the fabricated specimens were reconstructed and analyzed. The reconstructed images well coincided with real images taken with optical microscope and gave us enough reports on the defects in the ceramic specimen. The resolution of the system regarded as about $20{\sim}30$ micrometers.

  • PDF

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

Effect of Contrast-Enhanced $^{18}F$-FDG PET/CT on Measurements of Whole Body Bone Mineral Density and Body Composition by Dual-Energy X-Ray Absorptiometry (조영증강 $^{18}F$-FDG PET/CT가 이중에너지 X-선 흡수 계측법을 이용한 골밀도 및 체성분 측정에 미치는 영향)

  • Kim, Seong Su;Lee, Sun Do;Lee, Nam Ju;Shin, Yong Cheol;Mo, Eun Hee;Lee, Chun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.7-11
    • /
    • 2012
  • Purpose : The effect of concomitant use of $^{18}F$-FDG and intravenous contrast agent (CA) on dual-energy X-ray absorptiometry (DXA), was rarely reported. We had investigated these potentially confounding effects. Materials and Methods : Twenty-two patients had undergone DXA before and immediately after $^{18}F$-FDG PET/CT scans. Two DXA and 1 PET/CT scans had performed within one-day. $^{18}F$-FDG PET/CT scans had been performed with CA in 17 patients and without CA in 5 patients. Whole body bone mineral content (BMC), whole body bone mineral density (BMD), total fat mass (TFM), and lean body mass (LBM) were measured by DXA scanner before and after the $^{18}F$-FDG PET/CT scans. Results : BMC, BMD, TFM and LBM had significantly affected by $^{18}F$-FDG PET/CT with CA (BMC, +13.7%, from $2061.3{\pm}393.7$ to $2343.4{\pm}373.3$; BMD, +9.3%, from $1.07{\pm}0.09$ to $1.17{\pm}0.08$; TFM, -34.1%, from $17052.1{\pm}4049.9$ to $11237.1{\pm}2990.3$; LBM, +13.6%, from $45834.5{\pm}5662.1$ to $52094.0{\pm}6335.4$). However, $^{18}F$-FDG PET/CT without CA had no effect on the measurement of DXA (BMC, +2.4%, from $2197.7{\pm}391.6$ to $2251.5{\pm}380.9$; BMD, +1.8%, from $1.13{\pm}0.09$ to $1.15{\pm}0.07$; TFM, -6.8%, from $14585.6{\pm}3455.9$ to $13591.3{\pm}4351.4$; LBM, +2.2%, from $47360.5{\pm}8381.8$ to $48441.1{\pm}8488.1$). Conclusion : The measurements of DXA are affected by using CA. However, DXA scans might be unaffected by the presence of $^{18}F$-FDG administered for PET/CT.

  • PDF

Age-dependent Difference in the Computed Tomography Numbers of the Normal Parotid Gland of Koreans (나이에 따른 한국인 정상 이하선의 전산화단층촬영값의 차이)

  • Jeong Ho-Gul;Lee Eun-Sook;Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.451-458
    • /
    • 1999
  • Purpose : To determine normal CT number range of parotid gland by analyzing the change by age increase and the difference among individuals and between both sexes in CT number of normal parotid gland. Materials & Methods : 134 subjects who took the CT scan between the period of Jan. 1996 and Dec. 1997 at Yonsei University, Dental Hospital were selected. Criteria for selection were that the patients must be within the normal range clinically and radiologically, and the entire parotid gland on the axial view must be shown. Among the axial views. the one showing the greatest parotid gland size was selected and its CT number was recorded. Also. CT numbers from both masseter muscle were recorded as its control. Results : There was statistically significant correlation between CT number of right and left of parotid glands and masseter muscles. With the increase of age. there is a significant decrease in the CT number of parotid gland(p<0.05). There was no statistically significant difference in CT number between sexes except the 7th decade and beyond age group of parotid gland(p>0.05). Conclusion : As age increases, CT number of parotid gland has a tendency to decrease, and there is no significant difference in the CT numbers between left and right parotid gland. Therefore in the CT scan of patients suspected of having a salivary gland disease of the parotid gland. to consider normal range of the age-dependent CT numbers of parotid gland and compare the CT numbers of the right and left parotid gland might be useful in diagnosing the disease.

  • PDF

Protective Effect of Pesticide on Radiation-Induced Cell Damage in Tradescantia 4430 Stamen Hairs (자주달개비 수술털에서 방사선에 의해 유발되는 세포손상에 대한 살충제의 방어효과)

  • 김진규;김원록;이창주;장화형;이영근
    • Korean Journal of Environmental Biology
    • /
    • v.17 no.1
    • /
    • pp.21-26
    • /
    • 1999
  • To investigate the combined effect of radiation and pesticide on Tradescantia somatic cell mutations, potted plants of Tradescantia 4430 on which parathion had been sprayed evenly 24 hours before irradiation. Radiation doses were 0.3, 0.5, 1.0 and 2.0 Gy of gamma-ray. The plants irradiated only with the gamma-ray radiation were used as control groups (CT). Pink mutation frequency increased linearly proportional to the radiation dose and the peak interval of elevated mutation frequencies appeared during 7 ~ 11 days after irradiation in both CT and Pa +${\gamma}$ groups. The slope of dose -response curve in CT was 5.99 ($r^2$= 0.988), while it was 3.43 (r$x^-2$=0.981) in Pa+${\gamma}$. It seemed that parathion pretreatment had a protective effect against radiation-induced cell damages since it decreased the slope value by 43%. It is suggested that an adaptive response or radiomodification could be induced in irradiated stamen hair cells by parathion pretreatment.

  • PDF

The Shape Preferred Orientation (SPO) Analysis in Estimation of Fault Activity Study (단층 활동 추적 연구에서의 Shape Preferred Orientation (SPO) 분석법)

  • Ho Sim;Yungoo Song;Changyun Park;Jaewon Seo
    • Economic and Environmental Geology
    • /
    • v.56 no.3
    • /
    • pp.293-300
    • /
    • 2023
  • The Shape Preferred Orientation (SPO) method has been used to analyze the orientation of fault motion, which is utilized as basic data for fault kinematics studies. The rigid grains, which as quartz, feldspar, and rock fragments, in the fault gouge are arranged in the P-shear direction through rigid body rotation by a given shear stress. Using this characteristic, the fault motion can be estimated from the SPO inversely. Recently, a method for securing precision and reliability by measuring 3D-SPO using X-ray CT images and examining the shape of a large number of particles in a short time has been developed. As a result, the SPO method analyzes the orientation of thousands to tens of thousands of particles at high speed, suggests the direction of fault motion, and provides easy accessibility and reliable data. In addition, the shape information and orientation distribution data of particles, which are by-products obtained in the SPO analysis process, are expected to be used as basic data for conducting various studies such as the local deformation of fault rocks and the fault generation mechanism.

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

duoPIXTM X-ray Imaging Sensor Composing of Multiple Thin Film Transistors in a Pixel for Digital X-ray Detector (픽셀내 다수의 박막트랜지스터로 구성된 듀오픽스TM 엑스선 영상센서 제작)

  • Seung Ik, Jun;Bong Goo, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.969-974
    • /
    • 2022
  • In order to maximize dynamic range and to minimize image lag in digital X-ray imaging, diminishing residual parasitic capacitance in photodiode in pixels is critically necessary. These requirements are more specifically requested in dynamic X-ray imaging with high frame rate and low image lag for industrial 2D/3D automated X-ray inspection and medical CT imaging. This study proposes duoPIXTM X-ray imaging sensor for the first time that is composed of reset thin film transistor, readout thin film transistor and photodiode in a pixel. To verify duoPIXTM X-ray imaging sensor, designing duoPIXTM pixel and imaging sensor was executed first then X-ray imaging sensor with 105 ㎛ pixel pitch, 347 mm × 430 mm imaging area and 3300 × 4096 pixels (13.5M pixels) was fabricated and evaluated by using module tester and image viewer specifically for duoPIXTM imaging sensor.