• Title/Summary/Keyword: X-선 CT

Search Result 150, Processing Time 0.032 seconds

Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry (대퇴골 경부 골절 환자에서 골다공증 평가를 위한 다중검출 CT의 이용: 이중에너지 X-선 흡수계측법과의 비교)

  • Hyo Jeong Lee;Ji Young Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.173-181
    • /
    • 2021
  • Purpose To evaluate the ability of the Hounsfield unit (HU) measurement of the femoral neck during multidetector computed tomography (MDCT) for assessing osteoporosis compared with dual-energy X-ray absorptiometry (DXA). Materials and Methods Forty-two patients with femoral neck fractures who underwent MDCT and DXA from July to December 2016 were included in this study. HU measurements were made of the cancellous portions of the normal contralateral femoral neck on MDCT. Bone mineral density (BMD) and T-scores were obtained at the femur DXA. Correlations of HU values with BMD and T-scores were analyzed using Spearman's correlation test. Results The mean BMD and T-score of the femoral neck were 0.650 g/cm2 and -2.4, respectively. The mean HU values for the normal, osteopenia, and osteoporosis groups were 131.9, 98.9, and 41.3, respectively. HU values at the femoral neck were positively correlated with BMD (r2 = 0.670; p < 0.001) and T-scores (r2 = 0.676; p < 0.001). Conclusion The HU values of the femoral neck on MDCT are significantly correlated with BMD and T-scores of femur DXA. The HU values may serve as a diagnostic tool for the screening of regional bone quality when MDCT is performed for other reasons.

A Clinical Review of Primary Tracheal Carcinoma (원발성 악성기관종양의 임상적 고찰)

  • Ryu, Jeong-Seon;Cho, Hyun-Myung;Yang, Dong-Gyoo;Lee, Hong-Lyeol;Kim, Se-Kyu;Chang, Joon;Ahn, Chul-Min;Shin, Kye-Chul;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.766-775
    • /
    • 1997
  • Background : Primary malignant tumors of the trachea are extremely rare entities and account for a mere 0.1 per cent of all malignancies of the respiratory tract. Because of vague localizing signs, symptoms and a usually negative routine chest film, the patients with tracheal tumors are often treated for asthma or chronic obstructive pulmonary disease for considerable period of time before correct diagnosis. Method : We have made a review of the 17 cases of primary tracheal tumors in recent 15 years. We reviewed the clinical features including history of smoking and respiratory symptoms, the official readings of initial routine chest film, the cytologic examination of sputum, the time of delay in diagnosis, and the response according to the therapeutic modalities. Results : Eight out of 9 patients with squamous cell carcinoma(SCC) were above 50 years old, five out of 6 patients with adenoid cystic carcinoma(ACC) were below 50 years old. The most common location of primary tracheal tumors was the upper one-third of trachea in 8 cases(47%). The most frequent symptoms were dyspnea in 13/17 cases(76%) and then stridor or wheezing, cough. and sputum in order. The routine chest roentgenographic examinations were not helpful to diagnose tracheal carcinoma and the cytologic examinations of sputums were helpful to diagnose tracheal carcinoma in only one case with adenocarcinoma. The mean times of delay in diagnosis of patients with sec and ACC were 5 months and 24.9 months respectively. We had bronchial asthma in 8 cases(47%) and tracheal tumors in 4 cases(23%) as initial clinical impression. Conclusion : We would like to perform more comprehensive diagnostic tools(high KVP technique, the fibroptic bronchoscopic examination, chest CT scan etc.) in patients who had the suggestive points for the tracheal tumorse(1. unexplained hemoptysis or hoarsness, 2. inspiratory wheezing or stridor, 3. wax and waning of dyspnea according to changes of position, 4. progressive asthmatics unresponsive to antiasthmatic therapy) and radical resection of tumor or external radiation therapy with curative aim as possible.

  • PDF

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.

Evaluation of Xerostomia Following 3 Dimensional Conformal Radiotherapy for Nasopharyngeal Cancer Patients (3차원 입체조형 방사선치료를 시행받은 코인두암 환자에서의 구강건조증 분석)

  • Park Young-Je;Park Won;Ju Sang-Gyu;Nam Hee-Rim;Oh Dong-Ryul;Park Hee-Chul;Ahn Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.24 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purose: This study is to evaluate the xerostomia following 3-dimensional conformal radiation therapy (3D CRT) in nasopharynx cancer patients using the xerostomia questionnaire score (XQS). Materials and Methods: Questionnaire study was done on 51 patients with nasopharynx cancer who received 3D CRT from Dec. 2000 to Aug. 2005. 3D CRT technique is based on 'serial shrinking field' concept by 3 times of computed tomography (CT) simulation. Total target dose to the primary tumor was 72 Gy with 1.8 Gy daily fractions. Xerostomia was assessed with 4-questions XQS, and the associations between XQS and time elapsed after RT, age, sex, stage, concurrent chemotherapy, and parotid dose were analyzed. Results: Concurrent chemotherapy was given to 40 patients and RT alone was given to 11 patients. The median time elapsed after 3D CRT was 20 ($1{\sim}58$) months and the mean XQS of all 51 patients was $8.4{\pm}1.9\;(6{\sim}14)$. XQS continuously and significantly decreased over time after 3D CRT ($X^2$=-0.484, p<0.05). There was no significant difference in XQS according to sex, age, and stag. However, XQS of concurrent chemotherapy patients was significantly higher than RT alone patients (P=0.001). XQS of patients receiving total mean parotid dose ${\ge}35 Gy$ was significantly higher than <35 Gy (p=0.05). Decreasing tendency of XQS over time after 3D CRT was observed. Concurrent chemotherapy and total mean parotid dose ${\ge}35 Gy$ were suggested to adversely affect radiation-induced xerostomia.

A Fat Density Mass in the Mediastinum (지방음영을 보인 종격동내 종괴)

  • Heo, Su Beom;Roh, Eun Suk;Kim, Dae Sung;Kim, Eui Hiung;Kang, Ji Ho;Lee, Sang Haak;Moon, Hwa Sik;Song, Jeong Sup;Park, Sung Hak;Park, Chan Beom;Lee, Bae Young;Kim, Hyeon Sook
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.2
    • /
    • pp.188-192
    • /
    • 2005
  • A 47-year-old female was admitted for an evaluation of a left mediastinal mass. The chest X-ray performed 16 months ago was normal, but the chest X-ray upon admission showed a large mass adjacent to the anterior aspect of the left hemidiaphragm. The CT scan demonstrated a large mass with a fat density in the left lower hemithorax. A focal diaphragmatic defect behind the xiphoid process was suspected. A thoracoscopic examination revealed omental herniation through the diaphragmatic defect. Therefore, a left thoracotomy was performed and the defect was repaired. We believe that a differential diagnosis should be needed to include a diaphragmatic omental hernia when a fat density mass is observed in the mediastinum.

Mineralogical Properties and Paragenesis of H-smectite (H-스멕타이트의 광물학적 특성과 생성관계)

  • Noh, Jin-Hwan;Hong, Jin-Sung
    • Journal of the Mineralogical Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.377-393
    • /
    • 2010
  • Pumiceous tuffs occurring in the Beomgockri Group are examined applied-mineralogical characteristics and their controling factors to evaluate their potentials as the adsorption-functional mineral resources. The pumiceous tuffs are diagenetically altered to low-grade zeolitcs and bentonites in the Janggi area. Compositional specialty due to the presence of pumice fragments induces the altered tuffs to exhibit the characteristic adsorption property combined with cation exchange capacity, specific surface area, and acidic pH. Unusual lower pH in the adsorption-functional mineral substances is turned out to be originated from the presence of H-smectite having $H^+$ in the interlayer site of the sheet structure. On account of disordered crystallinity resulting from the exchanged $H^+$ in the interlayer site, the smectite commonly forms crenulated edges in the planar crystal form and exhibits characteristic X-ray diffraction patterns showing comparatively lower intensities of basal spacings including (001) peak than conventional Ca-smectite. Based on the interpretation of paragenetic relations and precursor of the H-smectite, a genetic model of the peculiar clay mineral was proposed. The smectite formation may be facilitated resulting from the precipitation of opal-CT at decreasing pH condition caused by the release of H+ during diagenetic alteration of pumice fragments. Because of the acidic smectite, the low-grade mineral resources from the Beomgockri Group may be applicable to the adsorption industry as the raw materials of acid clays and bed-soil.

High-resolution computed tomography findings of lung parenchyme changes in very low birth weight infants treated with oxygen (산소 치료를 받은 극소저출생 체중아에서 폐 실질변화에 관한 고해상컴퓨터 단층촬영술 소견에 관한 연구)

  • Jin, Young Man;Chung, David Chanwook;Chang, Young Pyo;Lee, Yung Suk;Lee, En Sun
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.3
    • /
    • pp.255-261
    • /
    • 2007
  • Purpose : The objective of this study is to observe high-resolution computed tomography (HRCT) findings of lung parenchyme in very low birth weight (VLBW) infants between the corrected age of 38-42 weeks who were treated with oxygen after birth, and to compare them to the clinical severity of bronchopulmonary dysplasia (BPD). Methods : The lungs of fourty-four VLBW infants with gestational ages of less than 32 weeks and birth weights of less than 1,500 g who were treated with oxygen after birth were examined using HRCT taken when the corrected age was between 38-42 weeks. Common findings among the infants and the frequency of their occurrences were noted. Total CT scores obtained by the summation of air trapping and actelectasis scores and the ratio of bronchus-to-pulmonary artery diameter were used to quantitatively evaluate HRCT findings and correlate them with the clinical severity of BPD as defined by Jobe-Bancalari diagnostic criteria. Results : 1) The most common findings in HRCT images of the lungs were air trapping (56%), atelectasis (70.5%), linear opacity (77%), and distortion of the bronchopulmonary bundle (65.9%). These findings were more commonly observed in infants with BPD in a mixed pattern than those without (P<0.05). However, abnormal findings were also found in HRCT images of some infants without BPD. In infants with BPD, air trapping, atelectasis and total CT scores were higher than those without BPD. Also infants with BPD had a lower bronchus-to-pulmonary artery diameter than those without BPD (P<0.05). 2) The total CT scores (r=0.799, P<0.0001) and the ratio of bronchus-to-pulmonary artery diameter (r=0.576, P<0.0001) showed a linear correlation with the clinical severity of BPD. Conclusion : HRCT findings in VLBW infants between the corrected age of 38-42 weeks who had been treated with oxygen after birth are useful in revealing pathologic changes in the lung parenchyme and show a good correlation with the clinical severity of BPD.

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF

Clinical Usefulness of Implanted Fiducial Markers for Hypofractionated Radiotherapy of Prostate Cancer (전립선암의 소분할 방사선치료 시에 위치표지자 삽입의 유용성)

  • Choi, Young-Min;Ahn, Sung-Hwan;Lee, Hyung-Sik;Hur, Won-Joo;Yoon, Jin-Han;Kim, Tae-Hyo;Kim, Soo-Dong;Yun, Seong-Guk
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.91-98
    • /
    • 2011
  • Purpose: To assess the usefulness of implanted fiducial markers in the setup of hypofractionated radiotherapy for prostate cancer patients by comparing a fiducial marker matched setup with a pelvic bone match. Materials and Methods: Four prostate cancer patients treated with definitive hypofractionated radiotherapy between September 2009 and August 2010 were enrolled in this study. Three gold fiducial markers were implanted into the prostate and through the rectum under ultrasound guidance around a week before radiotherapy. Glycerin enemas were given prior to each radiotherapy planning CT and every radiotherapy session. Hypofractionated radiotherapy was planned for a total dose of 59.5 Gy in daily 3.5 Gy with using the Novalis system. Orthogonal kV X-rays were taken before radiotherapy. Treatment positions were adjusted according to the results from the fusion of the fiducial markers on digitally reconstructed radiographs of a radiotherapy plan with those on orthogonal kV X-rays. When the difference in the coordinates from the fiducial marker fusion was less than 1 mm, the patient position was approved for radiotherapy. A virtual bone matching was carried out at the fiducial marker matched position, and then a setup difference between the fiducial marker matching and bone matching was evaluated. Results: Three patients received a planned 17-fractionated radiotherapy and the rest underwent 16 fractionations. The setup error of the fiducial marker matching was $0.94{\pm}0.62$ mm (range, 0.09 to 3.01 mm; median, 0.81 mm), and the means of the lateral, craniocaudal, and anteroposterior errors were $0.39{\pm}0.34$ mm, $0.46{\pm}0.34$ mm, and $0.57{\pm}0.59$ mm, respectively. The setup error of the pelvic bony matching was $3.15{\pm}2.03$ mm (range, 0.25 to 8.23 mm; median, 2.95 mm), and the error of craniocaudal direction ($2.29{\pm}1.95$ mm) was significantly larger than those of anteroposterior ($1.73{\pm}1.31$ mm) and lateral directions ($0.45{\pm}0.37$ mm), respectively (p<0.05). Incidences of over 3 mm and 5 mm in setup difference among the fractionations were 1.5% and 0% in the fiducial marker matching, respectively, and 49.3% and 17.9% in the pelvic bone matching, respectively. Conclusion: The more precise setup of hypofractionated radiotherapy for prostate cancer patients is feasible with the implanted fiducial marker matching compared with the pelvic bony matching. Therefore, a less marginal expansion of planning target volume produces less radiation exposure to adjacent normal tissues, which could ultimately make hypofractionated radiotherapy safer.

Congenital Cystic Adenomatoid Malformation Associated with Pectus Excavatum -1 case report (누두흉을 동반한 선천성 낭종성 선종양기형 -1례 보고-)

  • An, Byeong-Hui;Mun, Hyeong-Seon;Na, Guk-Ju
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.231-235
    • /
    • 1997
  • Congenital cystic adenomatoid malformation of the lung is a rare pulmonary malformation, Although it is one of the most common congenital anomalies which cause acute respiratory distress in the newborn infants, characterized by marked proliferation of terminal respiratory structures. We have experienced an unusual case of congenital cystic adenomatoid malformation associated with pectus excavatum. The patient was 3-year-old female who suffered from cough and high fever for 20 days, and antibiotic therapy was given in other hospital before transfer to our hospital. The findings on chest X-ray, chest CT, aortogram, and selective bronchial arteriogram showed cystic lesions in the right upper and middle lobe accompanied but severe pectus excavatum. Right bilobectomy for pulmonary lesion and costosternal elevation for pectus excavatum was performed simultaneously with successful result. The postoperative course was uneventful and the patient was discharged on the twentieth postoperative day.

  • PDF