• Title/Summary/Keyword: X-선 촬영

Search Result 358, Processing Time 0.026 seconds

A Double-coin in esophagus (흥미있는 식도이물 1례)

  • 강주원;장혁순;박성남
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1983.05a
    • /
    • pp.13.2-13
    • /
    • 1983
  • Foreign bodies in air and food passages are not uncommon conditions in otolaryngological field and we can find out numerous causes of esophageal foreign bodies in literatures. Radiological exammination is essential and important method in diagnosis of foreign bodies in esophagus. The authors experienced a case of foreign body double coins, in esophagus in a 4-year - old girl and the authors emphasizing that in cases of esophageal foreign bodies radiological examination should always be included lateral view as well as anteroposterior view of neck especially when coins in the esophagus is suspected.

  • PDF

X-ray image system design for non-destructive inspector (비파괴 검사용 X선 영상시스템 설계)

  • Lee, Eui-Yong;Nam, Hyung-Jin;Jo, Nam-In;Sul, Yong-Tae
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.11a
    • /
    • pp.147-149
    • /
    • 2006
  • 본 연구는 산업용과 의료용에 사용되는 비파괴 검사용 X 선 영상시스템에 이용되는 X 선을 직접 감지하는 방식의 센서를 실리콘 반도체 재료를 사용하여 개발하는데 목적이 있다. 현재 사용되고 있는 비파괴 시험 용 검사 방법은 X-선을 사용하고 감지 필름 또는 고가의 감지재료를 사용하고 있으나 본 과제에서는 경제성이 있으며 기술기반이 확고한 실리콘 재료를 사용하고 디지털 촬영 방식을 도입하여 컴퓨터로 시험결과를 영상 처리한다는 장점이 있으며 영상 자료의 컴퓨터 베이스 처리와 영상 저장이 편리하게 이루어졌다.

  • PDF

The efficacy of computerized tomographic scan for chest trauma (흉부외상 환자에 대한 전산화 단층촬영의 효용성)

  • Roh, Hwan-Kyu;Choi, Ho;Kim, Young-Jin;Kim, Jung-Tae;Soh, Dong-Moon;Ryu, Han-Young;Lee, Cheol-Joo
    • Journal of Chest Surgery
    • /
    • v.31 no.3
    • /
    • pp.298-303
    • /
    • 1998
  • Computerized tomography(CT) is an effective technique in the initial evaluation of the abdomen and head following blunt trauma. To evaluate the efficacy of CT of the thorax, a retrospective study comparing early thoracic CT scanning with initial chest roentgenogram (CXR) was carried out on 134 patients with blunt trauma on the chest. Among 134 patients, 45 patients had normal initial chest roentgenogram and 24 patients showed normal CT findings. Sensitivities of diagnosing pneumothorax and pleural effusion by CXR were low (46.2 and 62.9% respectively), whereas 71.4%(45/63) of patients had thoracostomy only by CXR. Although sometimes abused, CT of the thorax is effective in the initial diagnosis.

  • PDF

Comparison Evaluation of Image Quality with Different Thickness of Aluminum added Filter using GATE Simulation in Digital Radiography (GATE 시뮬레이션을 사용한 알루미늄 부가필터 두께에 따른 Digital Radiography의 영상 화질 비교 평가)

  • Oh, Minju;Hong, Joo-Wan;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.81-86
    • /
    • 2019
  • In X-ray image, the role of filtration through the filter is to reduce the exposure of the patient by using photon which is useful in formation of the image, and at the same time, enhance the contrast of the image. During interaction between photon and object, low energy X-rays are absorbed from the site of a few cm of the first patient's tissue, and high energy X-rays are the one which form the image. Therefore, the radiation filter absorbs low energy X-ray in order to lower the exposure of the patient and improve the quality of the image. The purpose of this study is to compare the effect on the image quality by differences of added filter through simulation image and actual radiation image. For that purpose, we used Geant4 Application for Tomographic Emission (GATE) as a tool for Monte Carlo simulation. We set actual size, shape and material of Polymethylmethacrylate (PMMA) Phantom on GATE and differentiated the parameter of added filter. Also, we took image of PMMA phantom with same parameter of added filter by digital radiography (DR). Than we performed contrast-to-noise ratio (CNR) evaluation on both simulation image and actual DR image by Image J. Finally, we observed the effect on image quality due to different thickness of added filter, and compared two images' CNR evaluation's transitions of change. The result of this experiment showed decreasing in the progress of CNR on both DR and simulation image. It is ultimately caused by decreasing in contrast on image. In theory, contrast decrease with kVp increased. Given that condition, this study found out that filter makes not only decreasing total dose by absorbing low energy of X-ray, but also increasing average energy of X-ray.

An Iterative Method for Flat-Field Correction of Digital Radiography When Detector is at Any Position (반복적인 방법을 이용한 임의의 DR detector 위치에서의 flat field correction 방법 연구)

  • Kim, Do-Il;Lee, Hyoung-Koo;Kim, Sung-Hyeon;Park, Dae-Sop;Choe, Bo-Young;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.64-66
    • /
    • 2004
  • When examing patients with DRs it is necessary to remove bad pixels and lines and to correct non-uniform offsets and x-ray field. For non-uniformity correction a flat field x-ray image is needed, and to obtain it the center of detector is usually aligned with the focal spot of the x-ray tube, which is conserved when examing patients to preserve the flat field. In some of radiographic techniques, however, it is necessary to move the x-ray tube off the center position of detector or tilt the detector. We investigated the effect of detector tilting on the non-uniformity correction, and propose a method to reduce the effect using a new algorithm. The flat field of X-ray in the DR detector could be guaranteed with this result.

  • PDF

Changes in Spatial Resolution at Position of the Detector in Digital Mammography System (디지털 엑스선유방촬영장치에서 검출기 위치에 따른 공간분해능의 변화)

  • Kim, Hye-Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.215-222
    • /
    • 2016
  • X-ray mammography is the most effective method for the diagnosis of calcified lesions of various breast diseases. To reduce patient dose and to obtain optimal image required for diagnosis, the performance of the mammography system should be maintained continuously. Because the target (anode) angle of the X-ray tube is measured from the central X-ray, the effective angle can be slightly different in view of the position on the detector, which can result in degrading spatial resolution of the imaging within the field of view. In this study, we measured the MTF to examine spatial resolution for positions on the detector in the digital mammography system. For a tungsten wire of $50{\mu}m$ diameter, the highest spatial frequency was obtained. It meant that a wire diameter for measuring MTF through LSF should be small compared to the pixel size of the detector used in the mammography system. The spatial resolution showed slightly different performance according to positions on the detector. The center position gave the best spatial resolution and positions away from the center showed the degraded performance although the difference of the spatial resolution was small. The effective focal spot size of the full width at half maximum also showed similar result. It concluded that the slightly increase of the effective focal spot size gave the degradation of the spatial resolution for positions on the detector.

Leakage and Scattered Radiation from X-ray Unit in Radiography (영상의학과 엑스선 발생장치의 누설 및 산란선량 측정)

  • Im, In-Chul;Lee, Jae-Seung;Kweon, Dae-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.155-159
    • /
    • 2011
  • The purposed of this study were measured the radiation exposure of patients and workers by generators, and the protection state for radiation facilities. The subject of the study by X-ray generators in university hospitals of capital area, we measured the maximum irradiation condition of 80 kVp, 200 mA, 0.1 second in the control entrance, control room window, entrance of radiography, adjacent site. The leakage dose per week was which the control entrance was 0.11 mR/week, control room window was 0.15 mR/week, entrance of radiography was 0.12 mR/week and adjacent site was 0.06 mR/week with X-ray unit the mean And the leakage mean dose was 0.11 mR/week. Diagnostic X-ray tubes must ensure that the leakage radiation in the maximum leakage dose in week emitted by the tube outside the useful beam does not exceed certain levels provided by standards.

Acquisition of Monochromatic X-ray Using Multilayer Mirror (다층박막 거울을 이용한 단색 엑스선 획득)

  • Chon, Kwon-Su
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.179-184
    • /
    • 2010
  • A hard X-ray microscope system for obtaining images of nano-spatial resolution has been widely studied and requires monochromatic X-ray. A multilayer mirror of 84% reflectivity was designed to acquire tungsten characteristic X-ray of 8.4 keV from the white beam generated from an X-ray tube, and the C/W multilayer mirror of $50{\times}50\;mm$ size and 5.65 nm d-spacing was fabricated by the ion-beam sputtering system. The C/W multilayer had a uniformity of 99.5%, and the structure of the multilayer mirror was verified by a TEM image. The obtainable x-ray reflectivity for the C/W multilayer mirror at 8.4 keV was estimated from measuring the X-ray reflectivity using the copper characteristic X-ray of 8.05 keV. Monochromatic X-ray of 8.4 keV was generated by combining a X-ray tube, and the reflectivity and monochromaticity were 77.1% and 0.21 keV, respectively. Monochromatic X-ray generated from the combination of an X-ray tube and an C/W multilayer mirror has enough potential to use X-ray source for hard X-ray microscope system of laboratory size. If the C/W multilayer mirror of d-spacing of a few nanometers can be fabricated, monochromatic X-ray corresponded to 17.5 keV, molybdenum characteristic X-ray, can be obtained and applied to mammography in the medical application.

The Manufacture of Digital X-ray Devices and Implementation of Image Processing Algorithm (디지털 X-ray 장치 제작 및 영상 처리 알고리즘 구현)

  • Kim, So-young;Park, Seung-woo;Lee, Dong-hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.195-201
    • /
    • 2020
  • This study studied scoliosis, one of the most common modern diseases caused by lifestyle patterns of office workers sitting in front of computers all day and modern people who use smart phones frequently. Scoliosis is a typical complication that takes more than 80% of the nation's total population at least once. X-ray are used to test for these complications. X-ray, a non-destructive testing method that allows scoliosis to be easily performed and filmed in various areas such as the chest, abdomen and bone without contrast agents or other instruments. We uses NI DAQ to miniaturize digital X-ray imaging devices and image intensifier in self-shielding housing with Vision Assistant for drawing lines to the top and the bottom of the spine to acquire angles, i.e. curvature in real-time. In this way, the research was conducted to see scoliosis patients and their condition easily and to help rapid treatment for solving the problem of posture correction in modern people.

The Characteristic of Temperature and Dose Distribution of intra oral X-ray Tube (강내형 X선 튜브 온도 및 선량 분포 특성)

  • Cho, Sungho;Lee, Rena
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.262-266
    • /
    • 2013
  • A new concept of periapical radiography, intra oral x-ray tube and detector system is introduced. It is new system that a miniature x-ray tube is inserted into mouse and it acquired digital image using external detector. In this study, we have investigated temperature and dose distribution of insertional x-ray tube for periapical radiography. To analyze temperature characteristic of x-ray tube, we attached the thermocouple to surface of x-ray tube and we measured the temperature according to distance. Also, we measured the dose distribution of a miniature x-ray tube according to distance. As a result, temperature was constant to $27^{\circ}C$ over 2mm without cooling system, dose distribution of x-ray tube was 3.14 and 1.84mGy in 3 and 5cm, respectively. Therefore, the proposed x-ray system works in lower dose than conventional dental x-ray system. Thus, it is considered that new concept of system will have a significant effect on medical imaging technology.