• Title/Summary/Keyword: X-선조사

Search Result 18, Processing Time 0.029 seconds

Cytotoxic Effect of X-irradiation of Mouse Tumor Cells in the Presence of Korean Ginseng Extract (마우스 종양세포의 세포독성에 미치는 인삼 추출액과 방사선조사의 병용 효과)

  • Kwon Hyoung-Cheol;Kim Jin-Ki;Kim Jung-Soo;Choi Dong-Seong
    • Radiation Oncology Journal
    • /
    • v.18 no.3
    • /
    • pp.200-204
    • /
    • 2000
  • Purpose : We already reported the results that aqueous extract of Korean ginseng roots showed a marked cytotoxicity. In this study, we investigated whether combined ginseng product with X-irradiation increase the cytotoxicity of tumor cells than X-irradiation or not. Materials and Methods : Fifty gram of Korean ginseng powder mixed with 1 L of distilled water was extracted with reflux flask under condition of $100^{\circ}C$ for 5 hrs. This aquaous ginseng extract was filtered, centrifuged and then was freezed under condition of $-90^{\circ}C$ for 16-18 hrs. The freezing extract was dried with freeze drier, and then diluted. X-irradiation was given to tumor cells by 6 MeV linear accelerator. The cytotoxicity of ginseng in vitro was evaluated from its ability to reduce the clonogenecity of fibrosarcoma (FSa II) cells. In X-irradiation alone group, each 2, 4, 6 and 8 Gy was given to tumor cells. In X-irradiation with ginseng group, 0.2 mg/mL of ginseng extract was exposed to tumor cells for 1 hour before X-irradiation. Results : The yield for 50 g of ginseng extract which was treated with freezing drier was 3.13 g($6.3\%$). Cytotoxicity In vitro was measured as survival fraction which was judged from the curve, at ginseng concentration of 0.001, 0.01, 0.1 and 1 mg/mL were $0.89\pm0.04$, $0.86\pm0.06$, $0.73\pm0.01$ and $0.09\pm0.02$, respectively. Survival fraction at X-irradiation alone of 2, 4, 6 and 8 Gy were $0.81\pm0.07$, $0.42\pm0.08$, $0.15\pm0.02$, $0.03\pm0.01$, respectively. But, suwival fraction in combined group of X-irradiation and ginseng (0.2mg/ml) at each same radiation dose were $0.28\pm0.01$, $0.18\pm0.03$, $0.08\pm0.02$, $0.006\pm0.002$, respectively (p<0.05). Conclusion : The yield for ginseng extract which was treated with freezing drier was $6.3\%$. Cytotoxicty of Fsa 11 in combined ginseng with X-irradiation group was increased than that of X-irradition alone group, and its enhancing effect seemed to be added.

  • PDF

Changes of Activities of Rabbit Pulmonary Surfactant Incubated at $37^{\circ}C$, and effect of X-Irradiation in Vitro ($37^{\circ}C$에서 incubate 한 가토(家兎) 폐포표면활성물질(肺胞表面活性物質)의 활성도(活性度)의 변화(變化)와 in vitro X 선조사(線照射)의 영향(影響))

  • Kim, Hyung-Kyu;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.5 no.2
    • /
    • pp.63-70
    • /
    • 1971
  • In an attempt to understand the possible effects of temperature and X-irradiation on the activities of surfactant in rabbits, the pulmonary surfactant from the rabbit was subjected to the incubation at $37^{\circ}C$ and X-irradiation with 900r in vitro, and activities of surfactant were measured at 10, 30, 60, and 90 minutes. Tension-area diagram of the lung extract was recorded automatically by the modified Langmuir-wilhelmy balance with a synchronized recording system designed in this Department. A comparison was made with the normal and the following results were obtained. 1) The maximal surface tension, minimal surface tension, width of the tension area diagram at the surface area of 40% and stability index of the normal rabbit lung extract were $31.6{\pm}3.11\;dynes/cm,\;8.2{\pm}0.56\;dynes/cm,\;21.4{\pm}4.40\;dynes/cm\;and\;1.12{\pm}0.22$,respectively. 2) In the $37^{\circ}C$ incubation group, maximal surface tension was similar to the normal value, while minimal surface tension was significantly lower and stability infer was markedly higher than the normal. 3) In the group where X-irradiation of 900r in vitro was applied, maximal surface tension did not differ greatly with the normal or the $37^{\circ}C$ incubation group. The minimal surface tension was significantly lower than the normal but comparing with the $37^{\circ}C$ incubation group, some decrease in minimal surface tension was noted. The width of the tension·area diagram at 40% and stability index in the irradiated group were significantly higher than the normal but a tendency of increase was noted comparing with the $37^{\circ}C$ incubation group.

  • PDF

KCl Crystal Growth and High Energy X Ray Expose of Properties (KCl 단결정의 성장 및 고 에너지 X선 조사 특성)

  • Park, Cheol-Woo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.31-36
    • /
    • 2008
  • Purpose: X ray irradiates material for dose distribution confirmation through material color variation to evaluate about possibility. Materials and Methods: That is rare earth material to pure KCl and KCl impurity Eu adding 0.5mol% by Czochralski method each single crystal grow and observed color variation of KCl X ray irradiation use of linear accelerator. Results: High energy X ray irradiation KCl:Eu show the blue fluorescence with purple color that pure KCl single crystal can confirm by show was not observed, but was colored violet. Conclusion: Colors variation of KCl founds stable color center from radiation and this color variation will be used usefully to X ray measurement material and phantom.

  • PDF

Effect of X-ray Irradiation on the Pulmonary Surfactant in Rabbits (흉부(胸部) X-선조사(線照射)가 가토폐포(家兎肺胞) 표면활성물질(表面活性物質)에 미치는 영향(影響))

  • Lee, Chull
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.63-73
    • /
    • 1968
  • It is well known that mammalian alveolar membrane is covered with a very thin layer of surfactant film which characteristically reduces surface tension of alveolar membrane, and maintains alveolar stability. Since Clements in 1957 demonstrated that the surfactant is extractable by mincing the lung tissue in saline, various studies on the subject have been succeeded by many workers. However, the effect of radiation on the surfactant is not well clarified. Present study was attempted to observe the effect of x-irradiation on the activity of surfactant in rabbits. X-ray in dose of 300 r, 600 r or 900 r was irradiated to the chest of rabbits. The lung was removed from normal or irradiated rabbits sacrificed by arterial blood shedding, and lung-saline extract, adding 3 grams of lung tissue to 50 mili-liters of saline, was prepared by means of Vertis homogenizer. Tension-area diagram of lung extract was recorded automatically by a modified Langmuir-Wilhelmy balance with a synchronized recording system designed in this department. The surface tension of lung extract was measured at 1st, 2 nd, 3 rd, 7 th and 15 th post-radiation day in 300 r irradiated group, at 3 rd, 7 th and 15 th post-radiation day in 600 r irradiated group, 3 rd and 7 th post-radiation day in 900 r irradiated group respectively. For the histo-pathological study, lung tissue preparations were made in all irradiatiated groups on the day of experiment and in normal group. The results obtained are summarized as follows: 1. The minimal surface tension, maximal surface tension and stability index of normal rabbits lung extracts were 7.68 dynes/cm, 38.84 dynes/cm, and 1.39 respectively. 2. The activity of surfactant was depressed prominently by x-irradiation. However, increase in the dose of x-irradiation did not show any significant change in the degree of surfactant activity suppression. The most marked depression in surfactant was observed at the third post-radiation day in all irradiated groups. 3. Activity of surfactant depressed by x-irradiation showed a tendency of recovering to normal on 15 th post-radiation day. 4. The tendency of change in activity of surfactant following x-irradiation was somewhat correlative with histo-pathological changes. But the degree of depression of surfactant by x-irradiation did not correspond to the degree of histo-pathological changes, and recovery of lung tissue from radiation damage, tissue edema and congestion, seemed to be followed by restoration of surfactant activity. 5. The width of the tension-area diagram was measured at the surface area of 40% in lung extract of normal and x-irradiated rabbits. And it was found that the changes of the width corresponded well with that of minimum surface tension and of stability index in all normal and x-irradiated groups.

  • PDF

Assessment of the Fertilizing Capacity of Domestic Animal Spermatozoa by Hamster Test II. Effects of incubation medium and X-ray irradiation on hamster test for boar spermatozoa (Hamster test를 이용한 가축정자의 수정능력 검정 II. 정액배지 및 X-선조사가 돼지정자의 Hamster test에 미치는 영향)

  • Kim Yong-Jun;Ji Dong-Boum
    • Journal of Veterinary Clinics
    • /
    • v.9 no.2
    • /
    • pp.373-390
    • /
    • 1992
  • To assay the fertilizing capacity of domestic animal spermatozoa by hamster test, semen were collected from 13 boars(Duroc. Landrace and Yorkshire) which had been proved to be fertile in the past. then, were preserved in BWW medium or in raw state at 18$^{\circ}C$ or at room temperature. The preserved semen were given each different treatment according to the experimental design and coincubated with zona-free hamster ova for 5 hours. The ova were stained by lacmoid and examined under phase contrast microscope to investigate the rates of ova bound with sperm(sperm binding). ova penetrated by sperm(penetration) and formation of a male pronucleus(pronucleus formation) and also numbers of both bound and penetrated sperm per ovum. Between BWW and TBM medium for boar sperm. no difference in the results of hamster test was obtained. The boar spermatozoa in BWW medium, BWW with caffeine, BWW with heparin, and BWW with both caffeine and heparin showed no difference in the results of hamster test. The boar spermatozoa in BWW medium containing both calcium and RSA showed considerably higher rates of sperm binding, penetration and pronucleus formation as well as higher numbers of both bound and penetrated sperm than those not containing calcium with or without BSA( p<0.01) and also the same results higher than that containing calcium without BSA( p< 0.05). The boar spermatozoa irradiated by X-ray(70 KVP, 20mA) for 3 seconds. then, maintained at 18$^{\circ}C$ for 18 hours showed considerably lower rate of sperm binding than all the other groups including the control and X-ray groups irradiated by smaller dose or maintained for shorter period(p<0.01), and also showed lower number of bound sperm than the other groups(p<0.01, p<0.05). All the control groups of both raw and diluted sperm in BWM medium showed higher rates of sperm binding, penetration and pronucleus formation as well as higher number of penetrated sperm than all the X-ray groups irradiated for 3 seconds(70KVP, 20mA) and maintained for either 3 or 18 hours (p<0.01, p<0.05). At the same time the control groups of diluted sperm showed considerably higher rates of sperm penetration and pronucleus formation than the control group of raw sperm( p<0.01). These results indicates that fertile boar sperm showed considerably lower rates In the results of hamster test, when incubated in the medium without calcium and irradiated by X-ray than when incubated in the medium with calcium and not irradiated by X-ray, respectively, to prove consequently that hamster test would be of great value in assaying the fertilizing capacity of boar spermatozoa.

  • PDF

Characteristies of the background fabric and coloring of "Buseoksa Temple Gwaebul" in the possession of the National museum of Korea (국립중앙박물관 소장 <부석사 괘불>의 바탕직물과 채색 특성)

  • Park Seungwon;Yu Heisun;Park Jinho;Cheon Juhyun
    • Conservation Science in Museum
    • /
    • v.31
    • /
    • pp.1-20
    • /
    • 2024
  • The "Buseoksa Temple Gwaebul" (1684, K969) in the possession of the National Museum of Korea is a large Buddhist hanging scroll produced for outdoor rituals (gwaebul) at the eponymous temple. The painting demonstrates the most complex composition among the existing Buddhist hanging scrolls as it depicts the Shakyamuni Buddha in the lower middle, surrounded by the Vairocana Buddha, Medicine Buddha, and Amitabha Buddha. This study examines the characteristics of the background fabric and the production methods of the scroll from Buseoksa Temple and explores the characteristics of the coloring techniques by integrating the results of a non-destructive analysis to determine the materials used for coloring. The gwaebul comprises a total of 13 panels, with 11 panels arranged side by side and one panel each added to the top and bottom. The background fabric of the painting consist of semi-transparent silk tabby for the nine panels in the center, and silk tabby for the four panels surrounding the four sides. The coloring materials used to paint the scroll were analyzed using X-ray fluorescence, and were confirmed to be inorganic pigments of red, yellow, green, blue, and white. For some parts painted in yellow and blue, the colors were expressed by first applying light white pigment before adding organic pigments. In addition, ink was used for the black lines and gold leaf was used for the patterns of the Buddhist robes. X-ray irradiation enabled the determination of the location and technique of coloring according to each pigment color by highlighting the difference in brightness depending on the main component and the thickness of each pigment.

Fabrication of Backscatter Electron Cones for Radiation Therapy (산란전자선을 이용한 강내측방조사기구의 제작과 특성)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.74-80
    • /
    • 2001
  • Purpose : Irradiation cones by using backscatter electrons are made for the treatment of superficial small lesions of skin, oral cavity, and rectum where a significant dose gradient and maximum surface dose is desired. Methods and Materials : Backscatter electrons are produced from the primary electron beams from the linear accelerators. The design consists of a cylindrical cone that has a thick circular plate of high atomic number medium (Pb or Cu) attached to the distal end, and the plate can be adjusted the reflected angle. Primary electrons strike the metal plate perpendicularly and produce backscatter electrons that reflect through the lateral hole for treatment. Using film and a parallel plate ion chamber, backscatter electron dose characteristics are measured. Results : The depth dose characteristic of the backscatter electron is very similar to that of the hard x-ray beam that is commonly used for the intracavitary and superficial lesions. The basckscatter electron energy is nearly constant and effectively about 1.5 MeV from the clinical megavoltage beams. The backscatter electron dose rate of $35\~85\;cGy/min$ could be achieved from modern accelerators without any modification. and the depth in water of $50\%$ depth dose from backscatter electron located at 6mm for $45^{\circ}$ angled lead scatter. The beam flatness is dependent on the slit size and the depth of treatment, but is satisfactory to treat small lesions. Conclusions : The measured data for backscatter electron energy, depth dose flatness dose rate and absolute dose indicates that the backscatter electrons are suitable for clinical use.

  • PDF

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF