• Title/Summary/Keyword: X ray image

Search Result 1,290, Processing Time 0.026 seconds

Evaluation of bone quality in alveolar crest obscured by dental implants ; A pilot study by densitometric digital analysis in mandibular bone specimen (치과 임플란트 주변 협설측 치조골의 변화분석 - 하악골 시편에서의 디지털 농도분석법을 이용한 실험적 고찰 -)

  • Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.900-913
    • /
    • 1998
  • Despite of technical difficulties, the combination of occlusal projection and densitometric digital analysis may ultimately provide a means of detection of subtle bone loss at the facial and lingual side of dental implant (Oblique occlusal view is more useful for $ITI^{(R)}$ dental implant due to its contour of shoulder as like tulip flower). In this study, conventional periapical projections of x-ray beam had shown more high sensitivity to detect the bony defects than oblique occlusal projections in alveolar crest obscured by dental implants or not, even if the difference was not statistically significant. Unlike conventional periapical projections. occusal projections combined with densitometric digital analysis technique may provide a means for detection of subtle bone change at the all around of implants without obscuring effect by implant itself. Although the results from this in vitro study were performed under limited circumstances, these results might afford more possibility and versatile modality of diagnosis options to clinician in the implant practice.

  • PDF

Evaluation of imaging reformation for root and pulp canal shapes of permanent teeth using a cone beam computed tomography (Cone beam형 전산화단층영상을 이용한 영구치 치근과 근관의 형태 평가)

  • Hong, Jong-Hyun;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.165-170
    • /
    • 2007
  • Purpose: To estimate the shape of root and pulp canal using a dental cone beam computed tomography (CBCT) and to evaluate the accuracy of imaging reformation. Materials and Methods: CBCT images were obtained with incisors, premolars, and molars as the destination by using PSR $9000N^{TM}$ Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) and i-CAT (Imaging Sciences International, Inc, USA) cone beam CT unit that have different kind of detector and field of view, and compared these with the shape and the size of actual root and root canal. Results: When the measuring value of cone beam computed tomography concerning to each root's bucco-lingual diameter and mesio-distal diameter was compared with the value of the actual root, it reveals an error range $-0.49{\sim}+0.63$ mm at PSR900N and $-0.97{\sim}+1.14$ mm at i-CAT (P>0.05). It was possible to identify and measure PSR$9000N^{TM}$ Dental CT system to the limit $0.48{\pm}0.06mm$ (P>0.05) and i-CAT CBCT to the limit $0.86{\pm}0.09mm$ (P<0.05) on estimating the size and the shape of root canal. Two kinds of CBCT images revealed the useful reproducibility to estimate the shape of root, but there was the difference to estimate the shape of root according to apparatus. The reproducibility of root shape in the image of three-dimensions at PSR 900N is low such as 0.65 mm in a case of minute root canal. Conclusions: CBCT images revealed higher accuracy of the imaging reformation for root and pulp and clinically CBCT is a useful diagnostic tool for the assessment of root and canal. However, there are different qualities of imaging reformation according to CBCT apparatus and limitation of reproducibility for minute root canals.

  • PDF

Prediction of Osteoporosis using Compositive Analysis of Trabecular Patterns on Proximal Femur (대퇴 근위부의 골소주 패턴에 대한 복합적인 분석을 통한 골다공증 예측 연구)

  • Lee, Ju-Hwan;Park, Sung-Yun;Jeong, Jae-Hoon;Kim, Sung-Min
    • The KIPS Transactions:PartB
    • /
    • v.19B no.2
    • /
    • pp.99-106
    • /
    • 2012
  • The purpose of this study was to determine the evaluation parameters' osteoporosis predictability in accordance with measuring regions by analyzing the correlations between bone mineral density and trabecular patterns derived from different measuring regions. Experimental subjects were a total of 40 female patients after menopause aged over 40 years, and were classified into 20 control and 20 osteoporotic groups according to the T-score. Bone mineral density was measured on femoral neck, trochanter and ward's triangle by DEXA(Dual Energy X-ray Absorptiometry). We designated ROI(Region of Interest) with $50{\times}50$ pixel size on each measuring regions, and extracted trabecular patterns by using existing image processing method. We also selected a total of eight evaluation parameters that are categorized into structural(mean gray level, area, perimeter, thickness and terminal distance), skeletonized parameters(number, length) and fractal dimension. As a result, it was observed that area, perimeter, thickness, terminal distance, number, length and fractal dimension reflected the bone mineral density with high statistical validity(p<0.003). We also confirmed that the evaluation parameters could predict the osteoporosis more efficiently.

Ultrasound Imaging of Normal Cardiac Structures with Convex Scanner in Puppies (강아지에서 컨벡스스캐너를 이용한 정상적인 심장구조물의 초음파상)

  • Jeong Soon-wuk;Park Hee-myung;Han Sook-hee;Yoon Jung-hee;Han Hong-ryul
    • Journal of Veterinary Clinics
    • /
    • v.11 no.2
    • /
    • pp.529-537
    • /
    • 1994
  • Sector scanner which has a conical end is used to image through the intercostal space because heart is protected by the ribs. Cardiac data published all around the world were also obtained by sector scanner. Although scanners being used in every small animal practice and animal hospital at college in Korea include convex ape and linear type, linear type is not appropriate f3r cardiac scan because of a wide contact surface. The purpose of this study is to establish ultrasonographic images of normal cardiac structures by measuring shape, size of reflectable cardiac structure according to restraint position in scanning normal heart of the puppies with 6.5 MHz convex scanner(SonoAce 4500, Medison, Korea) used in our veterinary teaching hospital, Seoul national university. Seventeen male and female puppies considered having healthy hear by X-ray and clinical examination are used feom April to July 1994. Scanning point selection of probe head and the distinction of imaged cardiac structures were accomplished by necropsy and cardiac scanning performed through thoracotomy under general anesthesia. At 10 o'clock position of transducer(at an angle of 30$^{\circ}$ between imaginary line from elbow joint to 3rd sternum and probe head, 60$^{\circ}$ from body surface, 4th intercostal space of right thorax) with the marker of scanner toward the head of dogs right atrium, left atrium and left ventricle were observed in 2, 3, 4, 5 intercostal space(2cm from the sternum) of experimental dog positioned ventrodorsally under general anesthesia. Under these conditions, the numerical values of imaged diastolic hear are as follows : the distance from skin to apex(mean$\pm$S.D) 47.53$\pm$6.94mm, thickness of left ventricular wall 6.00$\pm$1.60mm, length of left ventricle 16.27$\pm$5.31mm, width of left ventricle 15,33$\pm$4.25mm, length of left atrium 12.33$\pm$3.82mm, width of left atrium 11. 33$\pm$3.94mm, length of right atrium 1.00$\pm$2.41mm, width of right atrium 11.21$\pm$2.76mm and the area of left ventricle 270.92$\pm$109.81mm$^2$, area of left atrium 98.00$\pm$41.08mm$^2$, area of right atrium 62.75$\pm$21.04mm$^2$.

  • PDF

Clinical usefulness of facial soft tissues thickness measurement using 3D computed tomographic images (3차원 전산화단층촬영 영상을 이용한 안면 연조직 두께 계측의 임상적 유용성)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Choi Seong-Ho;Kim Chong-Kwan;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.2
    • /
    • pp.89-94
    • /
    • 2006
  • Purpose : To evaluate clinical usefulness of facial soft tissue thickness measurement using 3D computed tomographic images. Materials and Methods : One cadaver that had sound facial soft tissues was chosen for the study. The cadaver was scanned with a Helical CT under following scanning protocols about slice thickness and table speed; 3 mm and 3 mm/sec, 5 mm and 5 mm/sec, 7 mm and 7 mm/sec. The acquired data were reconstructed 1.5, 2.5, 3.5 mm reconstruction interval respectively and the images were transferred to a personal computer. Using a program developed to measure facial soft tissue thickness in 3D image, the facial soft tissue thickness was measured. After the ten-time repeation of the measurement for ten times, repeated measure analysis of variance (ANOVA) was adopted to compare and analyze the measurements using the three scanning protocols. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant intraobserver differences in the measurements of the facial soft tissue thickness using the three scanning protocols (p>0.05). There were no statistically significant differences between measurements in the 3 mm slice thickness and those in the 5 mm, 7 mm slice thickness (p>0.05). There were statistical differences in the 14 of the total 30 measured points in the 5 mm slice thickness and 22 in the 7 mm slice thickness. Conclusion : The facial soft tissue thickness measurement using 3D images of 7 mm slice thickness is acceptable clinically, but those of 5 mm slice thickness is recommended for the more accurate measurement.

  • PDF

Systemic Lupus Erythematosus Associated with Interstitial Pneumonia and Achalasia (식도 이완 불능증과 간질성 폐렴을 동반한 전신성 홍반성 낭창)

  • Kwon, Hye Lee;Hong, Kyung Wook;Lim, Seung Jin;Park, So Young;Bae, Young Deok;Kim, Kyung Ho;Choi, Jeong Hee;Mo, Eun Kyung;Park, Yong Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.4
    • /
    • pp.323-327
    • /
    • 2008
  • Systemic lupus erythematosus (SLE) is a multisystem disorder where the etiology is not clearly known. Symptomatic chronic interstitial pneumonitis is an uncommon manifestation, with a reported prevalence of 3~13%. Achalasia is rare disease that presents with failure in the relaxation of the esophagus sphincter. A 22-year-old woman was admitted to our hospital because of fever, cough and dyspnea. The patient had a history of pericardial effusion and Raynaud's phenomenon. The results of laboratory tests indicated the presence of lymphopenia and included positive antibody tests for antinuclear antibody and anti Sm antibody. A chest X-ray demonstrated the presence of peribronchial infiltration on both lung fields. A Chest CT image showed interlobar septal thickening, ground-glass opacity and a honeycomb appearance in both lung fields and esophageal dilatation with air fluid level. An esophagogram showed the presence of dilated esophagus ends that represented the non-relaxed lower esophageal sphincter. Manometry demonstrated incomplete sphincter relaxation. The case was diagnosed as systemic lupus erythematosus associated with interstitial pneumonia and achalasia.

Preparation of Chitosan-coated Magnetite Nanoparticles (키토산이 피복된 나노 크기의 자성체 분말 제조)

  • Cho, Jun-Hee;Ko, Sang-Gil;Ahn, Yang-Kyu;Song, Ki-Chang;Choi, Eun-Jung
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.1
    • /
    • pp.102-106
    • /
    • 2006
  • Magnetic nanoparticles can be used for a variety of biomedical applications. They can be used in the targeted delivery of therapeutic agents in vivo, in the hyperthermic treatment of cancers. in magnetic resonance (MR) imaging as contrast agents and in the biomagnetic separations of biomolecules. We have synthesized magnetite $(Fe_3O_4)$ nanoparticles using chemical coprecipitation technique with sodium oleate as surfactant. Nanoparticle size can be varied from 2 to 8nm by controlling the sodium oleate concentration. Magnetite phase nanoparticles could be observed from X-ray diffraction. Magnetic colloid suspensions containing particles with sodium oleate and chitosan have been prepared. Nanoparticles, both oleate-coated and chitosan-coated, have been characterized by several techniques. Atomic farce microscope (AFM) was used to image the coated nanoparticles. Magnetic hysteresis measurement were performed using a superconducting quantum interference device (SQUID) magnetometer at room temperature to investigate the magnetic properties of the magnetite nanoparticles. The SQUID measurements revealed superparamagnetism of nanoparticles.

Preparation of Biopolymer coated Magnetite And Magnetic Biopolymer Microsphere Particles for Medical Application (의학적 응용을 위한 생체 고분자로 피복 된 자성 나노 입자와 미소구체의 제조)

  • Ko, Sang-Gil;Cho, Jun-Hee;Ahn, Yang-kyu;Song, Ki-Chang;Choi, Eun-Jung
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.4
    • /
    • pp.221-227
    • /
    • 2006
  • We have synthesized uniform nanometer sized magnetite particles using chemical coprecipitation technique through a sonochemical method with surfactant such as oleic acid. Magnetite phase nanoparticles could be observed from X-ray diffraction. Magnetite nanoparticles is surface phase morphology and biopolymer-microspheres for Application Medical. Magnetite nanoparticles coated biopolymer. Atomic Force Microscope (AFM) was used to image the coated nanoparticles. Magnetic colloid suspensions containing particles with sodium oleate, chitosan and $\beta$-glucan have been prepared. The morphology of the magnetic biopolymer microsphere particles were characterized using optical microscope. Magnetic hysteresis measurement were performed using a superconducting quantum interference device (SQUID) magnetometer at room temperature to investigate the magnetic properties of the biopolymer microspheres and magnetite coated biopolymer including magnetite nanoparticles. Magnetic Resonance (MR) imaging was used to investigate biopolymer coated nanoparticles and biopolymer microspheres.

Diagnostic Value of Sonographic Medial Meniscal Extrusion (초음파적 내측 반월상 연골 탈출의 진단 가치)

  • Kim, Jung-Man;Lee, Dong-Yeob;Koh, In-Jun;Lee, Un-Bong
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.1
    • /
    • pp.7-12
    • /
    • 2009
  • Purpose: The purpose of this study was to correlate the degree of sonographic medial meniscal extrusion with MRI and arthroscopic findings. Materials and Methods: Out of these 32 patients, with medial meniscal tear who went on arthroscopic surgery, 14 patients had the medial meniscal tear and 18 patients had both lateral and medial meniscal tear. The extent of meniscal extrusion without meniscal tear was assesed in 24 patients who did not show meniscal tear on MRI. The extent of meniscal extrusion was measured between tibial medial joint line (excluded osteophyte) and the outer margin of the medial meniscus. Kellgren-Lawrence grading scale was assessed in plain X-ray image and the location of lesion was assessed during arthroscopic surgery. We also measured the extent of meniscal extrusion on MRI and sonography respectively, and compared each other. Results: There was significant difference between patients with medial meniscal tear and both lateral and medial meniscal tear, patients with medial meniscal tear, patients with both medial and lateral meniscal tear, patients without meniscal tear (P value<0.05). Conclusion: The Meniscus tear must be considered when sonography shows the meniscal extrusion more than 5 mm in length.

  • PDF

The effect of steroid for fibrous dysplasia of the humerus combined with multiple cystic lesion (낭종성 병변을 동반한 상완골의 섬유성 골이형성증에서 steroid의 효과 - 증례 보고 -)

  • Hahn, Soo-Bong;Shin, Kyoo-Ho;Kim, Bo-Hyun;Won, Jung-Hoon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.8 no.1
    • /
    • pp.20-26
    • /
    • 2002
  • Fibrous dysplasia is a benign pathologic condition in which the normal cancellous bone is replaced by the fibro-osseous tissue. It is found mostly in the femur, tibia, skull, rib, and humerus. Clinically it may develops pain, progressive deformity, and pathologic fracture. Curettage with bone graft has been the most popular treatment method thesedays. A 17-year-old female who had fibrous dysplasia of the humerus combined with multiple cystic lesion was treated by intralesional steroid injection into the lesion total 2 times. The follow-up plain X-ray which was taken 11 months after steroid injection reveals decrease in size and increase in bone density and cortex thickness. The follow-up MRI reveals significant decrease in size and signal intensity. The signal intensity was decreased to that of normal bone marrow in T2 weighted image. She complains no pain and lives symptom free in last follow-up at 2 years and 8 months after steroid injection.

  • PDF