• Title/Summary/Keyword: X ray image

Search Result 1,285, Processing Time 0.032 seconds

COMPARISON OF JAW BONE DENSITY IN YOUNG ADULTS AND POSTMENOPAUSAL WOMEN (젊은 성인과 폐경 여성간의 악골 골밀도에 관한 비교 연구)

  • Kim, Tae-Sung;Lee, Dong-Keun;Lee, Byung-Do;Jung, Sun-Kwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.2
    • /
    • pp.107-114
    • /
    • 2001
  • Objectives : To compare jaw bone density of young adults (control group) and post-menopausal women(experimental group) in periapical and panoramic film. Materials and Methods : The bone mineral density values of lumbar and femur were measured by dual-energy X-ray absorptiometry(DEXA) and T scores of lumbar were obtained. T scores were classified into 3 group (T<-2.5, $-2.5{\leqq}T<-1$, $-1{\leqq}T$). Radiographic densities of alveolar bones were measured from interdental bones of premolar, molar areas in the maxilla and mandible and expressed into copper step wedge thickness by Scion $Image^{(R)}$ program. We considered these values of step wedge thickness as bone density of alveolar bone. Panorama mandibular index(PMI) was calculated by the method that the height of the inferior cortex of the mandible was divided by the height from the lower border of the mandible to the superior edge of the mental foramen. Bone density of alveolar bone and PMI were analysed statistically. Results : There were significant differences in bone mineral density of lumbar and femoral neck between control and experimental groups. There were also significant differences in bone density of premolar and molar area of jaw between control and experimental groups by MANOVA test. When considered lumbar T variables, there was only difference in interdental bone density of maxillary molar area between control and experimental group, but there was interaction. Interdental bone density of experimental group was appeared higher in $-1{\leqq}T$ group and lower in T<-2.5 group than control group. There was significant difference in PMI between control and experimental groups, but there was also inter action, thus, PMI of experimental group was appeared higher in $-1{\leqq}T$ group and lower in T<-2.5 group than control group. Conclusion : There were significant differences of alveolar density and cortical bone thickness between young men and post-menopausal women in periapical and panoramic film. These differences were dependent on lumbar T.

  • PDF

Analysis of Mass Transport in PEMFC GDL (연료전지 가스확산층(GDL) 내의 물질거동에 대한 연구)

  • Jeong, Hee-Seok;Kim, Jeong-Ik;Lee, Seong-Ho;Lim, Cheol-Ho;Ahn, Byung-Ki;Kim, Charn-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.10
    • /
    • pp.979-988
    • /
    • 2012
  • The 3D structure of GDL for fuel cells was measured using high-resolution X-ray tomography in order to study material transport in the GDL. A computational algorithm has been developed to remove noise in the 3D image and construct 3D elements representing carbon fibers of GDL, which were used for both structural and fluid analyses. Changes in the pore structure of GDL under various compression levels were calculated, and the corresponding volume meshes were generated to evaluate the anisotropic permeability of gas within GDL as a function of compression. Furthermore, the transfer of liquid water and reactant gases was simulated by using the volume of fluid (VOF) and pore-network model (PNM) techniques. In addition, the simulation results of liquid water transport in GDL were validated by analogous experiments to visualize the diffusion of fluid in porous media. Through this research, a procedure for simulating the material transport in deformed GDL has been developed; this will help in optimizing the clamping force of fuel cell stacks as well as in determining the design parameters of GDL, such as thickness and porosity.

Three Dimensional Target Volume Reconstruction from Multiple Projection Images (다중투사영상을 이용한 표적체적의 3차원 재구성)

  • 정광호;진호상;이형구;최보영;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.167-174
    • /
    • 2003
  • In the radiation treatment planning (RTP) process, especially for stereotactic radiosurgery (SRS), knowing the exact volume and shape and the precise position of a lesion is very important. Sometimes X-ray projection images, such as angiograms, become the best choice for lesion identification. However, while the exact target position can be acquired by bi-projection images, 3D target reconstruction from bi-projection images is considered to be impossible. The aim of this study was to reconstruct the 3D target volume from multiple projection images. It was assumed that we knew the exact target position in advance, and all processes were performed in Target Coordinates, where the origin was the center of the target. We used six projections: two projections were used to make a Reconstruction Box and four projections were for image acquisition. The Reconstruction Box was made up of voxels of 3D matrices. Projection images were transformed into 3D in this virtual box using a geometric back-projection method. The resolution and the accuracy of the reconstructed target volume were dependent on the target size. An algorithm was applied to an ellipsoid model and a horseshoe-shaped model. Projection images were created geometrically using C program language, and reconstruction was also performed using C program language and Matlab ver. 6(The Mathwork Inc., USA). For the ellipsoid model, the reconstructed volume was slightly overestimated, but the target shape and position proved to be correct. For the horseshoe-shaped model, reconstructed volume was somewhat different from the original target model, but there was a considerable improvement in determining the target volume.

  • PDF

Noninvasive Evaluation of Coronary Artery Bypass Graft Patency by Electron Beam Tomography (전자선 단층 촬영을 이용한 관상동맥 우회로 개존의 비침습적 평가)

  • 최규옥;김호석;조범구
    • Journal of Chest Surgery
    • /
    • v.32 no.8
    • /
    • pp.693-701
    • /
    • 1999
  • Recently non-invasive diagnostic imaging replaced the invasive catheter angiography in the diagnosis of vascular disease. Catheter methods are now almost confined to the purpose of intervention. Coronary artery or coronary artery bypass graft still needs catheter technique because of small diameter and the cardiac motion. The last challenge for radiologists in this domain is to obtain a non-invasive imaging. Electron beam tomography(EBT) for high temporal resolution is able to obtain a coronary arteriogram or coronary artery bypass graft (CABG), of which CABG imaging is quite useful for the evaluation of patency. In our experience as well as others, the accuracy of EBT angiogram in evaluating CABG patency revealed that the accuracy of patency of saphenous vein grafts(SVG) is high due to relatively wide lumen, short and straight course and less influence from cardiac motion. The sensitivity and specificity of patency of SVGs were 92%, 97% respectively in the prospective evaluat on and 100% each in the retrospective evaluation. A false positive and a false negative case are rudimentary errors in the initial learing period. In contrast the analysis of left internal mammary artery(LIMA) graft was difficult due to the inherent small size and the adjacent surgical clips provoking beam-hardening artifact; therefore, the method of combining 3 dimensional reconstruction and flow mode study was important in improving the accuracy of LIMA patency. The sensitivity and specificity of LIMA patency were 100% and 80% in both prospective and retrospective evaluation. Therefore, EBT angiography is an accurate non-invasive diagnostic modality for evaluating the patency of CABG, particularly in SVGs. The accuracy can be improved with the improvement of the EBT and the development of the image reconstruction software.

  • PDF

Missed Skeletal Trauma Detected by Whole Body Bone Scan in Patients with Traumatic Brain Injury

  • Seo, Yongsik;Whang, Kum;Pyen, Jinsu;Choi, Jongwook;Kim, Joneyeon;Oh, Jiwoong
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.5
    • /
    • pp.649-656
    • /
    • 2020
  • Objective : Unclear mental state is one of the major factors contributing to diagnostic failure of occult skeletal trauma in patients with traumatic brain injury (TBI). The aim of this study was to evaluate the overlooked co-occurring skeletal trauma through whole body bone scan (WBBS) in TBI. Methods : A retrospective study of 547 TBI patients admitted between 2015 and 2017 was performed to investigate their cooccurring skeletal injuries detected by WBBS. The patients were divided into three groups based on the timing of suspecting skeletal trauma confirmed : 1) before WBBS (pre-WBBS); 2) after the routine WBBS (post-WBBS) with good mental state and no initial musculoskeletal complaints; and 3) after the routine WBBS with poor mental state (poor MS). The skeletal trauma detected by WBBS was classified into six skeletal categories : spine, upper and lower extremities, pelvis, chest wall, and clavicles. The skeletal injuries identified by WBBS were confirmed to be simple contusion or fractures by other imaging modalities such as X-ray or computed tomography (CT) scans. Of the six categorizations of skeletal trauma detected as hot uptake lesions in WBBS, the lesions of spine, upper and lower extremities were further statistically analyzed to calculate the incidence rates of actual fractures (AF) and actual surgery (AS) cases over the total number of hot uptake lesions in WBBS. Results : Of 547 patients with TBI, 112 patients (20.4 %) were presented with TBI alone. Four hundred and thirty-five patients with TBI had co-occurring skeletal injuries confirmed by WBBS. The incidences were as follows : chest wall (27.4%), spine (22.9%), lower extremities (20.2%), upper extremities (13.5%), pelvis (9.4%), and clavicles (6.3%). It is notable that relatively larger number of positive hot uptakes were observed in the groups of post-WBBS and poor MS. The percentage of post-WBBS group over the total hot uptake lesions in upper and lower extremities, and spines were 51.0%, 43.8%, and 41.7%, respectively, while their percentages of AS were 2.73%, 1.1%, and 0%, respectively. The percentages of poor MS group in the upper and lower extremities, and spines were 10.4%, 17.4%, and 7.8%, respectively, while their percentages of AS were 26.7%, 14.2%, and 11.1%, respectively. There was a statistical difference in the percentage of AS between the groups of post-WBBS and poor MS (p=0.000). Conclusion : WBBS is a potential diagnostic tool in understanding the skeletal conditions of patients with head injuries which may be undetected during the initial assessment.

Evaluation of bone quality in alveolar crest obscured by dental implants ; A pilot study by densitometric digital analysis in mandibular bone specimen (치과 임플란트 주변 협설측 치조골의 변화분석 - 하악골 시편에서의 디지털 농도분석법을 이용한 실험적 고찰 -)

  • Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.900-913
    • /
    • 1998
  • Despite of technical difficulties, the combination of occlusal projection and densitometric digital analysis may ultimately provide a means of detection of subtle bone loss at the facial and lingual side of dental implant (Oblique occlusal view is more useful for $ITI^{(R)}$ dental implant due to its contour of shoulder as like tulip flower). In this study, conventional periapical projections of x-ray beam had shown more high sensitivity to detect the bony defects than oblique occlusal projections in alveolar crest obscured by dental implants or not, even if the difference was not statistically significant. Unlike conventional periapical projections. occusal projections combined with densitometric digital analysis technique may provide a means for detection of subtle bone change at the all around of implants without obscuring effect by implant itself. Although the results from this in vitro study were performed under limited circumstances, these results might afford more possibility and versatile modality of diagnosis options to clinician in the implant practice.

  • PDF

Evaluation of imaging reformation for root and pulp canal shapes of permanent teeth using a cone beam computed tomography (Cone beam형 전산화단층영상을 이용한 영구치 치근과 근관의 형태 평가)

  • Hong, Jong-Hyun;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.165-170
    • /
    • 2007
  • Purpose: To estimate the shape of root and pulp canal using a dental cone beam computed tomography (CBCT) and to evaluate the accuracy of imaging reformation. Materials and Methods: CBCT images were obtained with incisors, premolars, and molars as the destination by using PSR $9000N^{TM}$ Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) and i-CAT (Imaging Sciences International, Inc, USA) cone beam CT unit that have different kind of detector and field of view, and compared these with the shape and the size of actual root and root canal. Results: When the measuring value of cone beam computed tomography concerning to each root's bucco-lingual diameter and mesio-distal diameter was compared with the value of the actual root, it reveals an error range $-0.49{\sim}+0.63$ mm at PSR900N and $-0.97{\sim}+1.14$ mm at i-CAT (P>0.05). It was possible to identify and measure PSR$9000N^{TM}$ Dental CT system to the limit $0.48{\pm}0.06mm$ (P>0.05) and i-CAT CBCT to the limit $0.86{\pm}0.09mm$ (P<0.05) on estimating the size and the shape of root canal. Two kinds of CBCT images revealed the useful reproducibility to estimate the shape of root, but there was the difference to estimate the shape of root according to apparatus. The reproducibility of root shape in the image of three-dimensions at PSR 900N is low such as 0.65 mm in a case of minute root canal. Conclusions: CBCT images revealed higher accuracy of the imaging reformation for root and pulp and clinically CBCT is a useful diagnostic tool for the assessment of root and canal. However, there are different qualities of imaging reformation according to CBCT apparatus and limitation of reproducibility for minute root canals.

  • PDF

Prediction of Osteoporosis using Compositive Analysis of Trabecular Patterns on Proximal Femur (대퇴 근위부의 골소주 패턴에 대한 복합적인 분석을 통한 골다공증 예측 연구)

  • Lee, Ju-Hwan;Park, Sung-Yun;Jeong, Jae-Hoon;Kim, Sung-Min
    • The KIPS Transactions:PartB
    • /
    • v.19B no.2
    • /
    • pp.99-106
    • /
    • 2012
  • The purpose of this study was to determine the evaluation parameters' osteoporosis predictability in accordance with measuring regions by analyzing the correlations between bone mineral density and trabecular patterns derived from different measuring regions. Experimental subjects were a total of 40 female patients after menopause aged over 40 years, and were classified into 20 control and 20 osteoporotic groups according to the T-score. Bone mineral density was measured on femoral neck, trochanter and ward's triangle by DEXA(Dual Energy X-ray Absorptiometry). We designated ROI(Region of Interest) with $50{\times}50$ pixel size on each measuring regions, and extracted trabecular patterns by using existing image processing method. We also selected a total of eight evaluation parameters that are categorized into structural(mean gray level, area, perimeter, thickness and terminal distance), skeletonized parameters(number, length) and fractal dimension. As a result, it was observed that area, perimeter, thickness, terminal distance, number, length and fractal dimension reflected the bone mineral density with high statistical validity(p<0.003). We also confirmed that the evaluation parameters could predict the osteoporosis more efficiently.

Ultrasound Imaging of Normal Cardiac Structures with Convex Scanner in Puppies (강아지에서 컨벡스스캐너를 이용한 정상적인 심장구조물의 초음파상)

  • Jeong Soon-wuk;Park Hee-myung;Han Sook-hee;Yoon Jung-hee;Han Hong-ryul
    • Journal of Veterinary Clinics
    • /
    • v.11 no.2
    • /
    • pp.529-537
    • /
    • 1994
  • Sector scanner which has a conical end is used to image through the intercostal space because heart is protected by the ribs. Cardiac data published all around the world were also obtained by sector scanner. Although scanners being used in every small animal practice and animal hospital at college in Korea include convex ape and linear type, linear type is not appropriate f3r cardiac scan because of a wide contact surface. The purpose of this study is to establish ultrasonographic images of normal cardiac structures by measuring shape, size of reflectable cardiac structure according to restraint position in scanning normal heart of the puppies with 6.5 MHz convex scanner(SonoAce 4500, Medison, Korea) used in our veterinary teaching hospital, Seoul national university. Seventeen male and female puppies considered having healthy hear by X-ray and clinical examination are used feom April to July 1994. Scanning point selection of probe head and the distinction of imaged cardiac structures were accomplished by necropsy and cardiac scanning performed through thoracotomy under general anesthesia. At 10 o'clock position of transducer(at an angle of 30$^{\circ}$ between imaginary line from elbow joint to 3rd sternum and probe head, 60$^{\circ}$ from body surface, 4th intercostal space of right thorax) with the marker of scanner toward the head of dogs right atrium, left atrium and left ventricle were observed in 2, 3, 4, 5 intercostal space(2cm from the sternum) of experimental dog positioned ventrodorsally under general anesthesia. Under these conditions, the numerical values of imaged diastolic hear are as follows : the distance from skin to apex(mean$\pm$S.D) 47.53$\pm$6.94mm, thickness of left ventricular wall 6.00$\pm$1.60mm, length of left ventricle 16.27$\pm$5.31mm, width of left ventricle 15,33$\pm$4.25mm, length of left atrium 12.33$\pm$3.82mm, width of left atrium 11. 33$\pm$3.94mm, length of right atrium 1.00$\pm$2.41mm, width of right atrium 11.21$\pm$2.76mm and the area of left ventricle 270.92$\pm$109.81mm$^2$, area of left atrium 98.00$\pm$41.08mm$^2$, area of right atrium 62.75$\pm$21.04mm$^2$.

  • PDF

Clinical usefulness of facial soft tissues thickness measurement using 3D computed tomographic images (3차원 전산화단층촬영 영상을 이용한 안면 연조직 두께 계측의 임상적 유용성)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Choi Seong-Ho;Kim Chong-Kwan;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.2
    • /
    • pp.89-94
    • /
    • 2006
  • Purpose : To evaluate clinical usefulness of facial soft tissue thickness measurement using 3D computed tomographic images. Materials and Methods : One cadaver that had sound facial soft tissues was chosen for the study. The cadaver was scanned with a Helical CT under following scanning protocols about slice thickness and table speed; 3 mm and 3 mm/sec, 5 mm and 5 mm/sec, 7 mm and 7 mm/sec. The acquired data were reconstructed 1.5, 2.5, 3.5 mm reconstruction interval respectively and the images were transferred to a personal computer. Using a program developed to measure facial soft tissue thickness in 3D image, the facial soft tissue thickness was measured. After the ten-time repeation of the measurement for ten times, repeated measure analysis of variance (ANOVA) was adopted to compare and analyze the measurements using the three scanning protocols. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant intraobserver differences in the measurements of the facial soft tissue thickness using the three scanning protocols (p>0.05). There were no statistically significant differences between measurements in the 3 mm slice thickness and those in the 5 mm, 7 mm slice thickness (p>0.05). There were statistical differences in the 14 of the total 30 measured points in the 5 mm slice thickness and 22 in the 7 mm slice thickness. Conclusion : The facial soft tissue thickness measurement using 3D images of 7 mm slice thickness is acceptable clinically, but those of 5 mm slice thickness is recommended for the more accurate measurement.

  • PDF