The Effects of Image Quality due to Scattering X-ray according to increasing Patient Thickness (피사체 두께에 따른 산란선 발생이 화질에 미치는 영향)

  • Park, Ji-Koon;Yang, Sung-Woo;Jun, Jae-Hoon;Cho, Su-Yeon;Kim, Kyo-Tae;Heo, Ye-Ji;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.671-677
    • /
    • 2017
  • In this study, scattering factors affecting the quality of medical images were quantitatively analyzed and investigated. MCNPX simulation was conducted by using ANSI phantom, made of tissue equivalent materials, to calculate the scattering ratio occurred by the increase of the object thickness. Then, the result of the simulation was compared with the result of actual radiation measurement. In addition, we evaluated the image quality by the RMS evaluation, RSD and NPS analysis using X-ray images acquired with increasing object thickness. Furthermore, the scattering ratio was analyzed by increasing the thickness of acrylic phantom on chest phantom. The result showed that the scattering ratio was increased to 57.2%, 62.4%, and 66.8% from 48.9%, respectively, when the acrylic phantom thickness was increased by 1 inch from 6.1 inches. The results of MCNPX simulation and the actual measured scattering dose showed similar results. Also, as a result of RMS measurement from acquired x-ray images, the standard deviation decreased as the object thickness increased. However, in the RSD analysis considering the average incident dose, the results were increased from 0.028 to 0.039, 0.051, 0.062 as the acrylic phantom thickness was increased from 6.1 inches to 7.1 inch, 8.1 inch, and 9.1 inch, respectively. It can be seen that the increase of the scattering effect due to the increase of the object thickness reduces the SNR. Also, the NPS results obtained by measuring scattered radiation incident on the detector resulted in the increase of the noise as the object thickness increased.

Early and Late Bowel Complication Following Irradiation of Cancer of the Uterine Cervix (자궁경부암의 고선량 치료후의 장관 합병증)

  • Kim Myung Se;Kim Kyung Ae;Kim Sung Kyu;Shin Sei One;Lee Sung Ho;Chang Jae Chun
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.59-70
    • /
    • 1989
  • Cervix cancer is the most common female cancer in Korea. In spite of their relatively local invasive tendency, still $44\%$ of patient will develop recurrent cancer. This result suggests that more aggressive local treatment may increase the cure rate but increased complication risk also cannot be avoidable. Various institutions proposed different treatment regimen, but recommended dose were about 4500 cGy for whole pelvis and 8000 cGy at point A, even though they agreed that those doses may not be satisfactory for control of bulky disease. 96 cases of invasive cervical cancer, treated with postoperative or primary radiation therapy were analyzed to determine the complication rate and prognostic factor in our treatment regimen Which is $5500\~1000 CGy$ higher than Other institution. Mean follow up duration was 21 months. Symptomatic patients including mild but persistent abdominal discomfort was $46\%$, but only 1 patient $(1\%)$ had operative treatment because of incomplete obstruction of small bowel. Most symptoms appeared within 12 months and most common complaints were frequent bowel movement. Barium enema and sigmoidoscopy were performed for persistent symptomatic patients. Only one patient had abnormal finding in barium enema which showed inefficiency of this method for detecting bowel complication. Patient's age, total tumor dose, total TDF, rectal dose were not significant risk factors for complication, but boost dose, previous history of operation had some relationship with complication risk. Even though dose of point A and rectum is $500\~1,000cGy$ higher than other institution, such a low rate of severe complications may suggest that fear of complications should not be overestimated than cure rate and the possibility of more aggressive treatment for better local control should not be underestimated.

  • PDF

A Study on Absorbed Dose in the Breast Tissue using Geant4 simulation for Mammography (유방촬영에서 Geant4 시뮬레이션를 이용한 유방조직내 흡수선량에 관한 연구)

  • Lee, Sang-Ho;Lee, Jong-Seok;Han, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.345-352
    • /
    • 2012
  • As the breast cancer rate is increasing fast in Korean women, people pay more attention to mammography and number of mammography have been increasing dramatically over the last few years. Mammography is the only means to diagnose breast cancer early, but harms caused by radiation exposure shouldn't be overlooked. Therefore, it is important to calculate the radiation dose being absorbed into the breast tissue during the process of mammography for a protective measure against radiation exposure. Because it is impossible to directly measure the radiation dose being absorbed into the human body, statistical calculation methods are commonly used, and most of them are supposed to simulate the interaction between radiation and matter by describing the human body internal structure with anthropomorphic phantoms. However, a simulation using Geant4 Code of Monte Carlo Method, which is well-known as most accurate in calculating the absorbed dose inside the human body, helps calculate exact dose by recreating the anatomical human body structure as it is through the DICOM file of CT. To calculate the absorbed dose in the breast tissue, therefore, this study carried out a simulation using Geant4 Code, and by using the DICOM converted file provided by Geant4, this study changed the human body structure expressed on the CT image data into geometry needed for this simulation. Besides, this study attempted to verify if the dose calculation of Geant4 interlocking with the DICOM file is useful, by comparing the calculated dose provided by this simulation and the measured dose provided by the PTW ion chamber. As a result, under the condition of 28kVp/190mAs, the Difference(%) between the measured dose and the calculated dose was found to be 0.08 %~0.33 %, and at 28 kVp/70 mAs, the Difference(%) of dose was 0.01 %~0.16 %, both of which showed results within 2%, the effective difference range. Therefore, this study found out that calculation of the absorbed dose using Geant4 Simulation is useful in measuring the absorbed dose in the breast tissue for mammography.

Efficacy of Pamidronate in Nephropathic Children with Ongoing Long Term Corticosteroid Therapy (장기 스테로이드 치료요법 중인 신질환 환자에서 Pamidronate의 효과)

  • Hong Hyun-Kee;Kim Eun-Seong;Kim Sung-Do;Cho Byoung-Soo
    • Childhood Kidney Diseases
    • /
    • v.8 no.1
    • /
    • pp.43-50
    • /
    • 2004
  • Background : Steroid-induced osteoporosis(SIO) is one of the serious complications of long-term steroid therapy, especially in growing children. Recently bisphosphonates have been used to treat or prevent SIO in adult, which is rare in children with glomerular diseases. We studied the effect of pamidronate on SIO using dual energy X-ray absorptiometry and biochemical markers of bone turnover. Methods : Forty four children receiving moderate-to-high doses of steroids were enrolled. They had no history of bone, liver, or endocrine disease. Patients were stratified by their baseline bone mineral density(BMD) findings. All patients received corticosteroids for 3 month and oral calcium supplementation(500 mg/day) daily. Among them, 28 patients were treated with placebo and 16 were treated with pamidronate(125 mg) for 3 months. Blood chemistry and bone mineral density(BMD) were measured at baseline, and 3months. In addition, parathyroid hormone(PTH), serum osteocalcin, and urinary dipyridinoline levels were evaluated. Results : In overall population, the mean lumbar spine BMD decreased from $0.754{\pm}0.211(g/cm^2)$ to $0.728{\pm}0.208(g/cm^2)$ in the placebo group(P<0.05) and increased from $0.652{\pm}0.194(g/cm^2)$ to $0.658{\pm}0.226(g/cm^2)$ in the pamidronate group(P>0.05). Conclusion : Pamidronate appears to be effective in preventing SIO in children with glomerular diseases requiring long-term steroids therapy. Further careful observation and follow-up might be needed for children receiving bisphosphonates such as pamidronate.

  • PDF

Clinical Characteristics of Asthmatic Patients Who Visited Emergency Room (응급실로 내원한 천식환자들의 임상적 특성)

  • Suh, Jung-Kyung;Lee, So-Ra;Lee, Sang-Youb;Lee, Sang-Hwa;Cho, Jae-Youn;Shim, Jae-Jeong;In, Kwang-Ho;Kang, Kyung-Ho;Yoo, Se-Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.290-297
    • /
    • 1997
  • Background : Despite remarkable progress of understanding the pathophysiology and therapy of bronchial asthma, asthma morbidity and mortality are on the rise. Also hospitalization and attending rates of emergency department for asthma have been increasing gradually. We analyzed clinical characteristics and prognosis of patients who visited emergency room due to asthma attack in order to define clinical characteristics of these group of patients. Method : We reviewed 105 adult asthmatic patients who attended emergency department of Korea University Hospital between August 1995 and July 1996, retrospectively. Results : 103 patients(56 female, 47 males, mean age : 48.6 years) attended-68 self referral, 18 practitioner referral and 17 OPD transfer- and 86 patients(83.5%) were admitted. Attending emergncy department was clearly more frequent in December(13.6%) and May(12.6%). Time lag between onset of asthmatic attack and arrival at the hospital was $14.2{\pm}15.5$ hour and initial peak expiratory flow rate was $166.7{\pm}68.3L/min$.(43.3% predicted) The commonest cause for visiting emergency room was aggravation of asthma due to upper respiratory tract infection in mild asthmatics. About half of them had history of previous ER visits. Their prognosis was not bad, but after discharge, about half of patients escaped from OPD follow-up. Conclusion : As a group they merit detailed attention and follow up arrangement. Clinician need to monitor and review the treatment plans, the medications, the patient's management technique, and the level of asthma control. For this group, plans for longer term treatment, including asthma education program and adjustment of overall treatment plan should be made.

  • PDF

sICAM-1, sE-selectin, sVCAM-1 Concentration in Patients with Pulmonary Tuberculosis (폐결핵 환자에서 SICAM-1, sE-selectin sVCAM-1농도의 변화)

  • Oh, Sang-Mi;Jang, Jae-Ho;Choi, Sang-In;Lee, Heung-Bum;Lee, Yong-Chul;Rhee, Yang-Keun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1256-1262
    • /
    • 1997
  • Background : Leukocyte-endothelial adhesion molecules have been implicated in the pathogenesis of inflammatory disease. ICAM-1, VCAM-1 and E-selectin are cell surface adhesion molecule on vascular endothelial cells. They are up-regulated by inflammatory cytokines and regulate the adhesion and migration of leukocytes across the endothelium. Tuberculosis, a granulomatous disorder is an infection caused by Mycobacterium tuberculosis. The clinical manifestations of tuberculosis are dependent on the cellular immune response to tubercule bacilli. Circulating adhesion molecules are probably formed by cleavage and release into the circulation of the extracellular domain of the membrane bound form. The elevated levels of circulating adhesion molecules have been reported in numerous disease state. To evaluate their role as markers of disease activity in tuberculosis, we measured a sE-selectin, sVCAM-1 and sICAM-1 levels in the serum with severities of mild, moderate and far advanced pulmonary tuberculosis. Methods : The control and test groups were divided as follows. Group I : control(n=5), Group II : patients with mild pulmonary tuberculosis(n=12), Group III : pateints with moderate pulmonary tuberculosis(n=20), Group IV : patients with far advanced pulmonary tuberculosis(n=19). Serum sICAM-1, sVCAM-1 and sE-selectin were measured by ELISA kit Results : Serum soluble adhesion molecules are elevated in patients with pulmonary tuberculosis, Circulating ICAM-1 levels were significantly elevated in patients with moderate and far advanced pulmonary tuberculosis when compared with control group. When compared with control group, serum sVCAM-1 levels showed significant elevation in patients with mild, moderate and far advanced pulmonary tuberculosis. Serum sE-selectin levels were significantly elevated in patients with far advanced pulmonary tuberculosis when compared with control group. Conclusion : These results suggest that sICAM-1, sVCAM-1, and sE-selectin may be invloved in the pathogenesis of tuberculosis. And, particularly, sICAM-1 and sVCAM-1 may be useful markers of the disease activity.

  • PDF

Analyze for the Quality Control of General X-ray Systems in Capital region (수도권지역 일반촬영 장비의 정도관리 분석)

  • Kang, Byung-Sam;Lee, Kang-Min;Shim, Woo-Yong;Park, Soon-Chul;Choi, Hak-Dong;Cho, Yong-Kwon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.93-102
    • /
    • 2012
  • Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.