• Title/Summary/Keyword: X선조사야

Search Result 478, Processing Time 0.033 seconds

The Radioprotective Effect of Ginseng Extracts on the liver in Mice that was irradiated by radiation (방사선이 조사된 생쥐 간에서 인삼추출물이 방사선 방어효과에 미치는 영향)

  • Ko, In-Ho;Chang, Chae-Chul;Koh, Jeong-Sam
    • Journal of radiological science and technology
    • /
    • v.27 no.2
    • /
    • pp.35-43
    • /
    • 2004
  • Radioprotective effects of ginseng extracts on liver damage induced by high energy x-ray were studied. To one group of ICR male mice were given white(50 mg/kg/day for 7days, orally) and fermenta ginseng extracts(500 mg/kg/day for 7days, orally) before irrdiation. To another group were irradiated by 5 Gy dose of high energy x-ray. Contrast group were given with saline(0.1 ml). This study also investigated the radioprotective effect between SOD, CAT, hydrogen peroxide and ginseng extracts on hepatic damage. This study measured the level of superoxide dismutase(SOD), catalase(CAT), hydrogen peroxide($H_2O_2$) in liver tissue. Administrating orally white (50 mg/kg/day for 7days, orally) and fermenta ginseng extracts(500 mg/kg/day), the activity of SOD, CAT were generally increased and the hydrogen peroxide($H_2O_2$) was decreased. After irradiation, the activity of SOD, CAT were generally decreased and the hydrogen peroxide($H_2O_2$) was increased. Therefore, ginseng extracts increased antioxidative enzyme activity. And We know that the antioxidatant effect of extracts from white and fermenta ginseng protect radiation damage by direct antioxidant effect involving SOD, CAT. It was included that ginseng can protect against radiation damage through its antioxidatant properties.

  • PDF

Evaluation of Photoneutron During Radiation Therapy when Using Flattening Filter and Tracking Jaw with High Energy X-ray (고 에너지 X선 방사선치료 시 Flattening Filter와 Tracking Jaw 사용에 따른 광중성자 발생 평가)

  • Park, Euntae;Jin, Seongjin;Park, Cheolwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.125-131
    • /
    • 2016
  • Radiation therapy is usually using linear accelerator and used X-ray energy is also getting higher. Recently linear accelerators has been developed 3F mode and tracking jaw technology and that was applied for patient therapy. This study aims at measuring photoneutrons depending on the use of 3F and tracking jaw system when radiation is irradiated using a linear accelerator. The generation of photoneutrons of 3F system was 70% smaller than 2F system and that of tracking jaw system was 83% higher than static jaw system. Photoneutron value is relatively low. However, it must be minimized for Photoneutron exposure during radiation therapy.

Evaluation of Relative Emission of Image Plate by Using Relative Sensitivity in Computed Radiography System (컴퓨터 방사선영상시스템에서 비감도를 이용한 영상판의 상대적 발광량 평가)

  • Seoung, Youl-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.355-361
    • /
    • 2014
  • The aim of the present study was to evaluate a relative emission of image plate (IP) in computed radiography (CR) system by using relative sensitivity in film/screen methods. The characteristic curve was obtained by using the uniform aluminum 11-step wedge penetrometer. X-ray exposure factors on radiographic digital image were 50 kVp, 10 mAs. We adjusted zero of all parameter of algorithms (MUSICA) so proximate to raw data and applied to 200 of exposure class. Modeling on relative emission of IP are used IP without fading time and IP after 4 hours, 8 hours, 12 hours, 24 hours in the respective storage after X-ray exposure. The results of this study showed that the sensitivity point density at the measuring of relative sensitivity in CR was suited pixel values of the 2000 easy to relatively measure the characteristic curve and when relative sensitivity is decreased, the amount of light emitted from the image signal for generating was also decreased. In conclusion, the proposed method of measurement of relative sensitivity can be utilized to evaluate the quantity of relative emission of IP in CR system.

Comparison of Parameter Using the Repair Survival Model Irradiated High-LET (LET 증가에 따른 회복 생존 모델의 파라미터 값 비교)

  • Choi, Eunae
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.177-181
    • /
    • 2017
  • Dose response curves using absorbed dose to the biological effect are usually available in case of conventional X beam. However, absorbed dose is not consider in treatment planning for carbon beam such as heavy ions. Because the biological effects also depend on other quantities such as the local variation, which is often characterized by the linear energy transfer (LET). So LQ model cannot explain the entire response of fractionated carbon beam irradiation. The variation in LET with penetration depth leads to substantial differences in biological effect of carbon beam. And it is therefore essential in treatment planning to calculate not only the absorbed dose but also the LET to estimate the biological outcome of the radiation of interest. LET variation plays an important role in the fractionated irradiations. It is suggested that consideration of LET is necessary in biophysical model.

Reliability Verification of FLUKA Transport Code for Double Layered X-ray Protective Sheet Design (이중 구조의 X선 차폐시트 설계를 위한 FLUKA 수송코드의 신뢰성 검증)

  • Kang, Sang Sik;Heo, Seung Wook;Choi, Il Hong;Jun, Jae Hoon;Yang, Sung Woo;Kim, Kyo Tae;Heo, Ye Ji;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.547-553
    • /
    • 2017
  • In the current medical field, lead is widely used as a radiation shield. However, the lead weight is very heavy, so wearing protective clothing such as apron is difficult to wear for long periods of time and there is a problem with the danger of lethal toxicity in humans. Recently, many studies have been conducted to develop substitute materials of lead to resolve these problems. As a substitute materials for lead, barium(Ba) and iodine(I) have excellent shielding ability. But, It has characteristics emitting characteristic X-rays from the energy area near 30 keV. For patients or radiation workers, shielding materials is often made into contact with the human body. Therefore, the characteristic X-rays generated by the shielding material are directly exposured in the human body, which increases the risk of increasing radiation absorbed dose. In this study, we have developed the FLUKA transport code, one of the most suitable elements of radiation transport codes, to remove the characteristic X-rays generated by barium or iodine. We have verified the reliability of the shielding fraction of the structure of the structure shielding by comparing with the MCPDX simulations conducted as a prior study. Using the MCNPX and FLUKA, the double layer shielding structures with the various thickness combination consisting of barium sulphate ($BaSO_4$) and bismuth oxide($Bi_2O_3$) are designed. The accuracy of the type shown in IEC 61331-1 was geometrically identical to the simulation. In addition, the transmission spectrum and absorbed dose of the shielding material for the successive x-rays of 120 kVp spectra were compared with lead. In results, $0.3mm-BaSO_4/0.3mm-Bi_2O_3$ and $0.1mm-BaSO_4/0.5mm-Bi_2O_3$ structures have been absorbed in both 33 keV and 37 keV characteristic X-rays. In addition, for high-energy X-rays greater than 90 keV, the shielding efficiency was shown close to lead. Also, the transport code of the FLUKA's photon transport code was showed cut-off on low-energy X-rays(below 33keV) and is limited to computerized X-rays of the low-energy X-rays. But, In high-energy areas above 40 keV, the relative error with MCNPX was found to be highly reliable within 6 %.

Distribution of X-ray Strength in Exposure Field Caused by Heel Effect (양극의 경사각 효과에 따른 조사야 X-선 강도 분포)

  • Jang, Keun-Jo;Kim, Nam-Hun;Lee, Jun-Haeng;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.223-229
    • /
    • 2011
  • When negative electron in x-ray tube is accelerated in to a high speed and then the currency of the electron is blocked by the target, x-ray happens by the conversion of the energy. The real area where the fast accelerated electron collides to a target area is called actual focal spot. When the string focused size is observed at the central ray side, where the direction x-ray comes out, the size seems to be reduced. This focus is called effective focal spot. According to radiation angle of x-rays tube, the degree of the negative pole side presents higher value than inclination, the amount of exposed radiation that patient receives differs by the angle of positive pole, which means effective focal spot is the variable. This paper presents the correlation between size of effective focal spot and amount of exposed radiation to the patient by it, and effective research for homogenized dose dispersion by the size of effective focal spot. In conclusion, following the focal size, effective range which was -8cm ~ 0 cm on average, was found and average dose rate was 0.019 R/min. Through this range, for patients with small radiation exposure, image with good density and resolution in aspect of diagnosing will be able to be obtained.

Calculation Method of Entrance Skin Dose in X-ray Beam Quality Factor (선질계수에 의한 피부입사선량 계산법)

  • Kim, Sung-Chul;Kim, Chong-Yeal;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.258-267
    • /
    • 2010
  • This interest in radiation exposure makes increasing doctor's awareness and knowledge of radiation dose in patients during X-ray test important in reducing patient's uneasiness. However, very few facilities are equipped with measurement instruments. Therefore, an intensive study to find out patient dose using computational method has been initiated. This study used special features of the bit system and NDD-M and directly measured the output dose of diagnostic X-ray instruments used in Korea to create tables. Two different methods were found to be adequate when applied to cases when X-ray outputs were both known and unknown, and comparative experiments with real measurement doses were carried out. Presented methods were found to provide more accurate results compared to the bit system and NDD-M. Therefore, patient dose during clinical trials were found to be more easily acceptable to medical personnel in the radiation field in terms of radiation exposure and reduction of medical X ray dose.

Dimensional Stability of Domestic Small-diameter Timbers Treated with Polyethylene Glycol (PEG(Polyethylene glycol)처리에 의한 국내산 주요 소경재의 치수 안정화에 관한 연구)

  • Kwon, Goo-Jung;Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.40-47
    • /
    • 2002
  • This study was carried out to investigate the dimensional stability of three softwoods (Pinus densiflora S. et Z., Pinus koraiensis S. et Z., Larix kaempferi CARR.) and two hardwoods(Quercus mongolica F., Quercus variabilis BL.) treated with polyethylene glycol(PEG). Existence of PEG in wood was examined by an X-ray diffraction method. Shrinkage of the sample woods decreased with increasing concentration of PEG. The dimensional stability of five species had improved highly in thirty percent solutions of PEG with molecular weight 1000~4000, and the dimension of PEG-treated softwoods was more stable than that of PEG-treated hardwoods. Weight gain and bulking effect of the woods treated with PEG increased with increasing concentration of PEG. X-ray diffractograms of Pinus koraiensis wood treated with PEG showed two peaks derived from PEG crystal at 2𝜃 = 19° and 2𝜃 = 23°. However, the diffractograms of Quercus mongolica wood did not present any peaks caused by PEG crystal. From the result of X-ray diffraction, it was revealed that the content of PEG in Pinus koraiensis wood was higher than that in Quercus mongolica wood.

A Study on the Neutron Dose Distribution in Case of 10 MV X-rays Radiotherapy (10MV X선 방사선 치료 시 중성자 선량 분포에 관한 연구)

  • Park, Cheol-Soo;Lim, Cheong-Hwan;Jung, Hong-Ryang;Shin, Seong-Soo
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.415-417
    • /
    • 2008
  • This study is to measure the radiation dose of neutrons generated by the particle accelerator during X-ray (photon) treatment with a neutron detection method by using CR-39, and to research how the generation of neutrons may incur problems associated with radiation doses for patient treatment when using high energy photons for cancer treatment as a clinical application. The findings are summarized as follows : The results showed that average 0.35mSv was measured with exposure of 1Gy photon in case of fast neutron, 0.65mSv with exposure of 2Gy photon, 1.82mSv exposure of 5Gy, 0.26mSv with exposure of 1Gy photon in case of thermal neutron, 0.56mSv with exposure of 2Gy photon, and 1.23mSv with exposure of 5Gy of photon. By measuring the occurrence of neutron by using Wedge Filter, it has been confirmed that the occurrence of neutrons increased when using Wedge Filter. The results also showed that more neutrons were detected over the existing experiments when using an SRS Cone requiring high doses of radiation. Total 2.85mSv neutrons were found on the average with exposure of 5Gy photon in case of fast neutron and 1.37mSv neutrons were found on the average with exposure of 5Gy photon in case of thermal neutron. During the general treatment, about 1.6 times more neutrons over 5Gy photon were found in case of fast neutron and about 1.12 time more neutrons over 5Gy photon were found in case of thermal neutron.

  • PDF

Variation of Image Quality and Dose by Applying Multi-Leaf Collimator for Digital Mammography (디지털 유방촬영장치에서 다엽 조리개 적용으로 인한 화질과 선량의 변화)

  • Kwon, Soon Mu;Kim, Boo Soon;Park, Hyung Jun;Kang, Yeong Han
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.535-540
    • /
    • 2015
  • Collimator has important functions with control primary X-ray that decrease radiation exposure dose for patients and reduce scatter ray and make better quality of image. But there are no regulations for X-ray mammography device of collimator, so widely used device adopt rectangularly controlled collimator. Though digital X-ray mammography device expand supply recently, rectangularly controlled collimator of film/screen mode still used. After searching for real condition of beam field with digital mammography, we made a multi-leaf collimator which is able to adjust the beam field in accordance with size and shape of breast, and we measuring up the transitions of image quality, average glandular dose(AGD) and, Dose area product(DAP). There are no significant differences between rectangularly controlled collimator and multi-leaf collimator, and DAP value decreased by 50.72%. As conclusion, there needs to expand the use of multi-leaf collimator for optimum adoption of beam field in digital mammography, and also need to develop an automatic regulation of beam field for reduce of exposure dose to patients.