• Title/Summary/Keyword: Wrist Rehabilitation

Search Result 153, Processing Time 0.028 seconds

Pain and Weakness on Unilateral Upper Extremity Diagnosed as Brachial Plexopathy after Herpes Zoster Infection (대상포진후 상완신경총병증으로 진단된 편측 상지의 통증과 위약)

  • Cho, Junmo;Kang, Si Hyun;Seo, Kyung Mook;Kim, Don-Kyu;Kim, Du Hwan;Shin, Hyun Iee
    • Clinical Pain
    • /
    • v.19 no.2
    • /
    • pp.124-128
    • /
    • 2020
  • Motor paralysis is a less common neurologic complication of herpes zoster. Until now, a few cases have been reported, and most of these cases showed brachial plexopathy involving one or two segments. We report a patient with pain and weakness on upper extremity diagnosed as brachial plexopathy after herpes zoster infection. An 88-year-old female patient complained not only tingling sense, pain, and swelling on right whole arm, but also weakness on this right upper extremity. On physical examination, weakness is seen in right shoulder abduction·shoulder flexion·elbow flexion·elbow extension· wrist extension (grade 4), finger flexion·finger abduction·finger extension·finger DIP flexion (grade 3). In electrodiagnostic study and magnetic resonance imaging study, she was diagnosed as the brachial plexopathy, whole branch involved. This is the only case of post-herpetic brachial plexopathy involving whole branch in domestic.

Enhancement of Fall-Detection Rate using Frequency Spectrum Pattern Matching

  • Lee, Suhwan;Oh, Dongik;Nam, Yunyoung
    • Journal of Internet Computing and Services
    • /
    • v.18 no.3
    • /
    • pp.11-17
    • /
    • 2017
  • To the elderly, sudden falls are one of the most frightening accidents. If an accident occurs, a prompt action has to be taken to deal with the situation. Recently, there have been a number of attempts to detect sudden falls using acceleration sensors embedded in the mobile devices, such as smart phones and wrist-bands. However, using the sensor readings only, the detection rate of the falls is around 65%. Ordinary daily activities such as running or jumping could not be well distinguished from the falls. In this paper, we describe our attempts on improving the fall-detection rate. We implemented a wrist-band fall detection module, using a three-axis acceleration sensor. With the pattern matching on the fall signal-strength frequency spectrum, in addition to the conventional signal strength measurement, we could improve the detection rate by 9% point. Furthermore, by applying two wrist-bands in the experiment, we could further improve the detection rate to 82%.

Reliability of the Modified Modified Ashworth Scale for the Muscle Tone of Poststroke Patients (뇌졸중 환자의 근긴장도 평가를 위한 개정된 개정된 Ashworth 척도의 신뢰도)

  • Kim, Tae-Ho;Kim, Yong-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.3
    • /
    • pp.477-485
    • /
    • 2010
  • Purpose : The clinical scale to assess spasticity of muscle was wildly used the modified Ashworth scale (MAS). But reliability of the MAS has been controverted for ambiguity among the grades. The purpose of this study was to establish the inter-rater reliability of the modified MAS (MMAS) translated into Korean in stroke patients. Methods : Twenty-five patients (sixteen men and nine women) with hemiplegia (ten right and fifteen left) were measured by two raters who were physical therapist in the rehabilitation hospital. The raters assessed spasticity of shoulder adductor, elbow flexor, wrist flexor, hip adductor, knee extensor, and ankle plantar flexor in the same patients according to ratings criteria of the MAS and the MMAS. Results : For the inter-rater reliability of the MAS, two raters agreed on 57.3% and the Kappa values were moderate ($\kappa$=0.41) between two rater. The inter-rater reliability of the MAS was fair for the wrist flexor and the hip adductor and moderate for the other muscles. The intra-rater reliability was good for the shoulder adductor and the knee extensor and moderate for the other muscles. For the inter-rater reliability of the MMAS, two raters agreed on 84.7% and the Kappa values were good ($\kappa$=0.78) between two rater. The inter-rater reliability of the MMAS was moderate for the hip adductor, and good for the shoulder adductor and the wrist flexor, and very good for the other muscles. The intra-rater reliability was good for the wrist flexor and the hip adductor and very good for the other muscles. Conclusion : This study suggests that the MMAS translated into Korean is reliable test scale for the spasticity with stroke patients in the clinical field.

Effects of Differential Stability on Control of Multi-Joint Coordination in the Upper Extremity: A Torque Component Analysis

  • Ryu, Young Uk;Shin, Hwa Kyung
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Purpose: The purpose of the present current study was to examine control of upper limb multi-joint movements with differential coordination stability. To achieve the goals of the study, torque analyses were utilized to answer questions about how torque components were differed among various elbow-wrist coordination patterns. Methods: Eight self-reported right-handed college students (3 males and 5 females, mean age=20.6 yr) were volunteered. The task required participants to rhythmically coordinate the flexion-extension motions of their elbow and wrist with coordination relationship of $0^{\circ}$, $90^{\circ}$, and $180^{\circ}$relative phases between the two joints. Mean relative phase and phase stability (standard deviation of relative phase) were computed to for analysisze of overall coordination performance. To determine the figure out characteristics of torque components in elbow and wrist joints, impulse values of muscle torque (MT) and interactive torque (IT) and MT as a percentage of cycle duration (MT-PCD) were analyzed. Results: Torque results showed that the proximal elbow joint generated motions with mainly muscle efforts regardless of coordination patterns, while the distal wrist joint adjusted the coordination patterns by changing amount of MT. Impulse analyses showed that the least stable $90^{\circ}$ pattern was performed by utilizing a similar coordination strategy of the most stable $0^{\circ}$ pattern. Conclusion: The present current study suggests that the roles of distal and proximal joints differ in order to achieve various multi-joint coordination movements. This study provides information for use in gives an idea to development of rehabilitation or training programs for to persons with an impaired upper limb motor ability.

Reliability Study of Three-Dimensional Motion Analysis Program for Wrist and Finger Joint Range of Motion Measurement (손목 · 손가락 관절가동범위 측정에 관한 3차원 동작분석 프로그램의 신뢰도 연구)

  • Park, Sun Ha;Park, Ji-Hyuk;Kim, Jong Bae;Jung, Young Jin;Lee, Joo Hyun;Park, Hae Yean
    • Therapeutic Science for Rehabilitation
    • /
    • v.12 no.1
    • /
    • pp.79-92
    • /
    • 2023
  • Objective : This study aimed to assess the reliability of a three-dimensional (3D) motion analysis program for measuring the range of motion (ROM) of wrist and finger joints. Methods : The study recruited 50 people who had no restrictions on wrist and finger movements, understood the purpose of this study, and agreed to participate. Using a goniometer and a 3D motion analysis program, a total of 11 wrist and finger ROM were measured once each. To measure the reliability of the 3D motion analysis program, the degree of agreement and inconsistency of the measured values were compared. Results : Analysis of the degree of agreement of the measured values revealed that 38 out of 44 items showed a very high degree of agreement. Regarding analysis of inconsistency in the measured values, inconsistencies were found in three items. Conclusion : The results of this study confirmed that the ROM of the joint could be measured using the 3D motion analysis program applied in this study. In addition, it might be expected that the 3D motion analysis program would be used in various clinical fields owing to the advantages of measurement convenience and accuracy.

The Comparison of the Acupuncture-Like Transcutaneous Electrical Nerve Stimulation and Conventional Transcutaneous Electrical Nerve Stimulation in Crossover Effect (침형 경피신경 전기자극법과 전통적인 경피신경 전기자극법의 교차효과 비교)

  • Kwon, Soo-Hyun;Bae, Eun-Young;Shin, Young-Ju;Lee, Jae-Ho
    • Physical Therapy Korea
    • /
    • v.3 no.2
    • /
    • pp.29-35
    • /
    • 1996
  • The purpose of this study was to compare acupuncture-like transcutaneous electrical nerve stimulation(ALTENS) with conventional transcutaneous electrical nerve stimulation(C-TENS) for crossover effect in healthy subjects. Forty subjects recieved ALTENS(20 persons), C-TENS(20 persons) to one upper extremity. Each technic was applied to the motor point of the wrist extensor muscle group for twenty-minutes. With the subject placed in supine the technics were applied at 80 Hz, 2-10 mA(ALTENS) and 10 Hz, 4-12 mA(C-TENS). Results revealed: (1) a significant difference between the pretreatment and posttreatment in each group(p<.05) (2) no significant difference between ALTENS and C-TENS(p>.05). In conclusion, there was no difference between ALTENS and C-TENS for crossover effect.

  • PDF

A clinical study of the affected part acupuncture moving treatment on the acute radial nerve palsy patient who has Cervical Herniation (환측 동기침법을 이용한 경추 추간판 탈출증 환자의 급성 압박성 요골신경마비 치험 1례)

  • Jeong, Hoon;Cho, Nam-Hoon;Park, Ji-Yong;Park, Hyun-Min;Bae, Sang-Eun;Hong, Nam-Jung
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.17 no.2
    • /
    • pp.73-81
    • /
    • 2011
  • Objectives : The purpose of this study is to evaluate the affected part acupuncture moving treatment for acute radial nerve palsy patient who has Cervical Herniation. Methods : We examined 1 patient with Radial nerve palsy who admitted Jaseng Hospital of Oriental Medicine. The patient was treated by the affected part acupuncture moving treatment including herbal mixture. Results : In this study, in the end of affected part acupuncture moving treatment, patient's condition has improved. Muscle strength was also increased. Conclusions : The affected part acupuncture moving treatment for acute radial nerve palsy was effective in restore of functional activities, but this treatment needs more study.

  • PDF

A Case of Combined Korean Medicine Treatment for Recurrent Limb Weakness after Guillain-Barré Syndrome Improvement: Case Report (길랑바레 증후군 호전 이후 재발한 사지무력 증상에 대한 한방 복합치료 1예: 증례보고)

  • Park, Song-Mi;Cho, Sung-Woo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.29 no.4
    • /
    • pp.135-142
    • /
    • 2019
  • The objective of this study is to propose Korean Medicine treatment for recurrent limb weakness after Guillain-Barre syndrome (GBS) improvement by intraveinous immunoglobulin, and to report its effectiveness. Manual muscle test (MMT), Korean modified Bathel index (K-MBI), and tendon reflex were used to evaluate the patient. The patient was improved hip joint, knee joint, ankle joint MMT from grade 3-/3- to grade 5/5 and in the upper limb the patient can do big joint exercise but cannot do micromovement like writing or using cell phone. When discharge date the patient's wrist joint MMT grade is improved grade 5-/5- to grade 5/5. The K-MBI score is improved from 71 to 86 and there was a big change in walking and chair/bed transfer, there was no change in tendon reflex. This study suggests that Korean Medicine can be effective for patients who have recurrent limb weakness after GBS improvement.

Flexor Carpi Radialis Tendon Rupture due to Repetitive Golf Swing (반복적인 골프 스윙으로 인한 노쪽손목굽힘근 힘줄의 파열)

  • Lee, Sang Chul;Koh, Sung Hoon;Jang, Jin Hyuk;Ahn, Jae Ki
    • Clinical Pain
    • /
    • v.18 no.2
    • /
    • pp.107-110
    • /
    • 2019
  • Flexor carpi radialis (FCR) muscle is located in the forearm anteriorly that runs through a synovial fibro-osseous tunnel in the forearm. We described a case of FCR tendon rupture due to repetitive overuse injury. A 55-year-old man, right-hand dominant, presented with right forearm pain and swelling which started 3 days ago while playing amateur golf. Focal tenderness and bruising over volo-ulnar region of the right forearm were examined. Plain radiographs showed soft tissue edema around lesion area and no detectable fracture. Ultrasonography showed multiple hypoechoic lesions suspected as hematoma of the flexor muscle group. After done magnetic resonance imaging, he was diagnosed with rupture of FCR tendon at proximal origin and strain of flexor digitorum superficialis and palmaris longus muscle. He received compressive dressing and restriction of wrist range of motion for three weeks. Two months later, remaining traces of lesions were observed at the follow-up ultrasonography and the pain disappeared.

Effect of Ultrasound-Guided Perineural Injection with Dextrose for Direct Traumatic Injury of Median Nerve (정중신경 손상에서 초음파 유도 하 신경주위 포도당 용액 주사치료의 효과)

  • Jung, Yu Sang;Park, Hyerin;Park, Jung Hyun;Park, Hee Jae;Cho, Han Eol
    • Clinical Pain
    • /
    • v.20 no.2
    • /
    • pp.127-130
    • /
    • 2021
  • Ultrasound (US)-guided hydrodissection (HD) is a widely applied therapeutic method to release the entrapped peripheral nerve. However, this therapy has only been studied for the nerve entrapments such as carpal tunnel syndrome, and there are no reports of its effect on direct nerve injuries with incomplete axonal damage. Here, we report a case of direct traumatic injury of a median nerve with incomplete axonal injury in a 28-year-old man. He presented hypoesthesia and weakness along with the median nerve territory of the left hand after a laceration wound of the wrist. The patient underwent a surgical procedure, but did not experience prominent improvement for the next six months. Symptoms improved after we performed the US-guided HD with dextrose. We propose this procedure as one of the new treatment methods for direct axonal injury of nerves including the median nerve.