• Title/Summary/Keyword: Wrist Rehabilitation

Search Result 153, Processing Time 0.027 seconds

Electromyography Triggered Training System for Wrist Rehabilitation (근전도 트리거 손목 재활 훈련 시스템 개발)

  • Kim, Younghoon;Le, DuyKhoa;Chee, Youngjoon;Ahn, Kyoungkwan;Hwang, Changho
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.148-155
    • /
    • 2013
  • This study is about the development of the wrist rehabilitation system for the patient who has limited capability of movement after stroke. Electromyography triggered training system (ETTS) can play the role between complete passive training and patient activating training system. Surface EMG was measured on pronator teres muscle and biceps brachii muscle for wrist pronation and supination. Our system detects whether the subject makes muscular effort for pronation or supination or nothing in every 50 ms. When the effort level exceeds the preset percentage of maximal voluntary contraction, the motor rotates according to the direction of the intention of the subject. EMG triggers the motor rotation for the wrist rehabilitation training until the preset angle. To evaluate its performance, the maximum voluntary contraction level was measured for 4 subjects at first. With the audio-visual instruction to rotate the wrist (pronation or supination) the subjects made effort to follow the instruction. After calculating root mean square (RMS) for 50 ms, the controller determines whether there was muscular effort to rotate while holding the motor. When there was an effort to rotate, the controller rotates the motor 0.8 degree. By comparing the RMS values from two channels of EMG, the controller determines the rotational direction. The onset delay is $0.76{\pm}0.24$ s and offset delay is $0.65{\pm}0.22$ s for pronation. For supination the onset delay is $1.24{\pm}0.41$ s and offset delay is $0.77{\pm}0.22$ s. The system responded fast enough to be used for rehabilitation training. The controller perceived the direction of rotation 100% correctly for the pronation and 97.5% correctly for supination. ETTS was developed and the fundamental functions were validated for normal subjects. The clinical validation should be done with patients for real world application. With ETTS, the subjects can train voluntarily over the limitation of the range of motion which increases the effectiveness of the rehabilitation training.

Development of the Myoelectric Hand with a 2 DOF Auto Wrist Module (2 자유도 자동손목관절을 가진 근전 전동의수 개발)

  • Park, Se-Hoon;Hong, Beom-Ki;Kim, Jong-Kwon;Hong, Eyong-Pyo;Mun, Mu-Seong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.8
    • /
    • pp.824-832
    • /
    • 2011
  • An essential consideration to differentiate prosthetic hand from robot hand is its convenience and usefulness rather than high resolution or multi-function of the robot hand. Therefore, this study proposes a myoelectric hand with a 2 DOF auto wrist module which has 6 essential functions of the human hand such as open, grasp, pronation, supination, extension, flexion, which improves the convenience of the daily life. It consists of the 3 main parts, the myoelectric sensor for input signal without additional attachment to operate the prosthetic hand, hand mechanism with high-torqued auto-transmission mechanism and self-locking module which guarantee the safety under the abrupt emergency and minimum power consumption, and dual threshold based controller to make easy for adopting the multi-DOF myoelectric hand. We prove the validity of the proposed system with experimental results.

Isokinetic Measures of Forearm Muscle Strength in Young Normal Adults (등속성 운동시 20대 정상성인의 손목 관절근력의 정상치 측정)

  • Kim, Do-Yon;Kim, Hyon-Kyoung;Baek, Sung-Ho;Jung, Kyung-Soo
    • Physical Therapy Korea
    • /
    • v.1 no.1
    • /
    • pp.47-54
    • /
    • 1994
  • This study was designed to develop an objective method of strength measurement of muscles controlling the wrist joint in normal subjects. Forty subjects (20 male, 20 female) with a mean age of 22 years, were tested isokinetically at $60^{\circ}/sec$ and $120^{\circ}/sec$. Results were as follows, 1) Peak torque for wrist flexors, extensors were significantly different for both speeds, but wrist ulnar deviator, radial deviator peak torques were not, 2) Mean values for all muscle groups controlling the wrist were not significantly different for both speeds in the female group, 3) All mean values at both $60^{\circ}/sec$ and $120^{\circ}/sec$ were significantly different between males and females, 4) Means and standard deviations of wrist joint angle of movement at peak torque were determined.

  • PDF

The Clinical Effect of Rehabilitation Protocol for Distal Radius Fracture in Korean Medicine: A Report of 3 Cases (원위 요골 골절에 대한 한방 재활치료 프로토콜 적용의 임상적 효과: 증례 보고)

  • Ha, Won-Bae;Geum, Ji-Hye;Koh, Nak-Yong;Lee, Jung-Han
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.28 no.3
    • /
    • pp.97-106
    • /
    • 2018
  • The objective of this study was to propose a rehabilitation protocol for distal radius fracture in Korean Medicine and to report its effectiveness. Three patients who had undergone distal radius fracture were treated using the rehabilitation protocol in Korean Medicine. We estimated the outcome evaluating physical examination findings of the wrist joint, numeric rating scale and quick the Disabilities of the Arm, Shoulder and Hand (DASH) score. After the treatment, we observed that wrist movement, numeric rating scale and quick DASH score were improved. A rehabilitation in Korean Medicine can be effectively used for distal radius fracture patients. The limitation of this study was the insufficient number of cases. Further studies are needed to design a rehabilitation protocol in Korean Medicine.

DULEX, A Wearable Hand Rehabilitation Device for Stroke Survivals (뇌졸중 환자를 위한 착용형 손 재활훈련기기, DULEX)

  • Kim, Young-Min;Moon, In-Hyuk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.10
    • /
    • pp.919-926
    • /
    • 2010
  • This paper proposes a wearable hand rehabilitation device, DULEX, for persons with functional paralysis of upper-limbs after stoke. DULEX has three degrees of freedom for rehabilitation exercises for wrist and fingers except the thumb. The main function of DULEX is to extend the range of motions of finger and wrist being contracture. DULEX is designed by using a parallel mechanism, and its parameters such as length and location of links are determined by kinematic analysis. The motion trajectory of the designed DULEX is aligned to human hand to prevent a slip. To reduce total weight of DULEX, artificial air muscles are used for actuating each joint motion. In feedback control, each joint angle is indirectly estimated from the relations of the input air pressure and the output muscle length. Experimental results show that DULEX is feasible in hand rehabilitation for stroke survivals.

Cupping Therapy Combined with Rehabilitation for the Treatment of Radial Palsy: a Case Report

  • Benli, Ali Ramazan;Senay, Demir Yazici;Koroglu, Mustafa;Mutlu, Tansel;Erturhan, Selman;Ogun, Muhammet Nur;Sunay, Didem
    • Journal of Acupuncture Research
    • /
    • v.35 no.1
    • /
    • pp.1-3
    • /
    • 2018
  • This case report demonstrates the beneficial effects of cupping therapy (CT) in a 35-year-old man who is diagnosed with a fracture of the radial shaft due to a motorcycle accident. One year after the treatment started, pseudoarthrosis developed in the radius and an autogenous iliac bone graft was performed. However, extension dysfunction in the wrist became evident. After another 6 months of physical therapy and rehabilitation, no improvements were observed. Therefore, CT and adjunctive electrostimulation were performed, after 30 days of treatment, marked recovery of muscle function and full wrist extension were observed, as determined by electromyography and a grade 5/5 on the Medical Research Council power of wrist extension scale. The results in this case study suggest that CT in conjunction with adjunctive electrostimulation, may accelerate functional recovery from postoperative radial palsy, and provide a useful alternative treatment in this situation.

Design of Upper-limb Rehabilitation Device with Power-assist Function for Stroke Survivals (뇌졸중 환자용 동력보조형 상지재활훈련기의 설계)

  • Bae, J.H.;Moon, I.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.79-85
    • /
    • 2011
  • In this paper, we proposed a design of upper-limb rehabilitation device with power-assist function for stroke survivals. The designed upper-limb rehabilitation device has three degrees of freedom; it is possible to perform flexion and extension motions of wrist, index finger and the other fingers except the thumb independently. The power-assist for wrist motion is performed by a pneumatic double-acting cylinder, but the fingers are actuated by electrical linear actuators to assist motions. A prototype upper-limb rehabilitation device and its controller were implemented. The position controller showed 0.8 mm errors in the steady-state. Experimental results showed that the proposed upper-limb rehabilitation device with power-assist function is feasible.

Artificial Neural Network based Motion Classification Algorithm using Surface Electromyogram (표면 근전도를 이용한 Artificial Neural Network 기반의 동작 분류 알고리즘)

  • Jeong, E.C.;Kim, S.J.;Song, Y.R.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.1
    • /
    • pp.67-73
    • /
    • 2012
  • In this paper, Artificial Neural Network(ANN) based motion classification algorithm is proposed to classify wrist motions using surface electromyograms(sEMG). surface EMGs are obtained from two electrodes placed on the flexor carpi ulnaris muscle and extensor carpi ulnaris muscle of 26 subjects under no strain condition during wrist motions and used to recognize wrist motions such as up, down, left, right, and rest. Feature is extracted from obtained EMG signals in time domain for fast processing and used to classify wrist motions using ANN. DAMV, DASDV, MAV, and RMS were used as features and accuracies of motion classification based on ANN were 98.03% for DAMV, 97.97% for DASDV, 96.95% for MAV, 96.82% for RMS.

  • PDF

The Study of Distribution of Upper Extremity Surgery for Korean Baseball Player (한국 프로야구 선수의 상지 수술 분포 연구)

  • Park, Jun-hyuck;Seo, Hyun-kyu
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.22 no.1
    • /
    • pp.71-76
    • /
    • 2016
  • Background: The objective of this research is to provide base line data on Korea Baseball rehabilitation treatment by presenting the distribution of upper extremity surgeries according the surgical sites of Korean professional baseball players. Methods: The targets of this research are 561 players from nine Korean baseball clubs. The number of players that have undergone surgery was investigated. In other words, the frequency of shoulder joint surgeries, elbow joint surgeries, and wrist and hand surgeries per each baseball club was investigated. Results: The number of the players who have had surgeries was 151, but among the players, there were some who have had repeated surgeries for which the total number of surgery experience was 162. The result showed that elbow joint surgeries were the most frequently enacted, followed by shoulder joint surgeries, and wrist and hand surgeries. From the nine clubs, Samsung was the club with the highest frequency of surgeries. Conclusions: This research shows that Korean professional baseball players need special training centers with systematic rehabilitation programs. Another conclusion suggests that urgent need for rehabilitation program of upper arm which particularly focused on elbow joint is existing. On the basis of this research, we expect more studies on the specific rehabilitation programs which is categorized by injury areas.

  • PDF