• Title/Summary/Keyword: Worst Case Discharge

Search Result 15, Processing Time 0.021 seconds

Stress mode proposal for an efficient ESD test (효율적인 ESD(ElectroStatic Discharge) test를 위한 Stress mode 제안)

  • Gang, Ji-Ung;Chang, Seog-Weon;Kwack, Kae-Dal
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1289-1294
    • /
    • 2008
  • Electrostatic discharge(ESD) phenomenon is a serious reliability concern. It causes approximately most of all field failures of IC. To quality the ESD immunity of IC product, there are some test methods and standards developed. ESD events have been classified into 3 models, which are HBM, MM and CDM. All the test methods are designed to evaluate the ESD immunity of IC products. This study provides an overview among ESD test methods on ICs and an efficient ESD stress method. We have estimated on all pin combination about the positive and negative ESD stress. We make out the weakest stress mode. This mode called a worst-case mode. We proposed that positive supply voltage pin and I/O pin combination is efficient because it is a worst-case mode.

  • PDF

Discussion on the Criterion for the Determination of On-Water Oil Removal Resource Requirement in Korea (우리나라 기름오염 방제능력 확보기준의 타당성)

  • Kang Seong-Gil;Sung Hong-Gun;Lee Moonjin;Choi Hyuek-Jin;Yu Jeong-Seok;Kang Chang-Gu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.5 no.4
    • /
    • pp.3-18
    • /
    • 2002
  • The present study was carried out to discuss the suitability of the criterion for the determination of the on-water oil removal resource requirement in Korea by comparison with the US criterion. According to the present criterion in Korea, the on-water response operation against the worst case discharge assuming the oil spillage of 60,000 ton from the accident of DWT 300,000 tanker requires the oil recovery capacity of 19,425 kl/hr (on-water recovery volume 20,000 ton). Under the US criterion, the recovery capacity of 16,667 kl/hr is required to respond to oil spill accident of the worst case discharge from the DWT 300,000 tanker. The result shows that resource requirement from the Korean criterion is 16% higher than US criterion, indicating that thc Korean criterion is reasonable.

  • PDF

Influence of Plasma Treatment & UV Absorbent on Lightfastness Improvement of Brazilin (플라즈마 전처리와 자외선 흡수제에 의한 소목의 내일광성 향상에 관한 연구)

  • 신정숙;손원교
    • The Research Journal of the Costume Culture
    • /
    • v.11 no.1
    • /
    • pp.66-74
    • /
    • 2003
  • This study is to improve the worst lightfastness of a natural dye. To modify the fiber surface, low temperature oxygen plasma was carried out on silk fabric. The result is followed below after the examination of surface shape, dyeability, color change, UV absorbent influence and lightfastness. 1. When electric discharge outputs are 60W, 80W and 100w, and processing times are 10minutes, 20minutes and 40minutes, the etching effect of surface increased as electric discharge outputs and processing times increased. 2. When examined UV absorbent for 5hours, 10hours, 20hours, 40hours and 80hours, the value changes of E are 1.47, 2.51, 2.91, 3.71, 4.51 and 5.31 in case of Al pre-mordanting/ prasma 80W, 20min./ UVabsorbent 5% (100:1), 2.31, 2.47, 3.84, 3.90, 3.61 and 4.42 in case of Al pre-mordanting/prasma 80W, 20min.1 UV absorbent 5% (o.w.f.). The lightfastness decreased when UV absorbent increased. 3. Dyeability of the samples pre-treated with five different methods was in the following order: plasma processing for 20minutes at 60W/Al pre-mordanting > Al pre-mordanting > plasma processing for 20minutes at 60W > Al after-mordanting. non mordanting Plasma treatment had superior effect on dyeability. 4. When UV absorbent was applied in fabric, the sample under higher electric discharge out puts showed more effective in improving lightfastness.

  • PDF

Sports injuries: a 5-year review of admissions at a major trauma center in the United Kingdom

  • Ahmad Hammad Hassan;Aref-Ali Gharooni;Harry Mee;James Geffner;Fahim Anwar
    • Journal of Trauma and Injury
    • /
    • v.36 no.1
    • /
    • pp.39-48
    • /
    • 2023
  • Purpose: Sports offer several health benefits but are not free of injury risk. Activity dynamics vary across sports, impacting the injury profile and thereby influencing healthcare resource utilization and health outcomes. The purpose of this study was to investigate sports-related major trauma cases and compare differences across sports and activity groups. Methods: A retrospective case notes review of sports-related major traumas over a 5-year period was conducted. Demographic, hospital episode-related, and health outcome-related data were analyzed, and differences were compared across sports and activity groups. The Glasgow Outcome Scale (GOS) at discharge was used as the primary outcome measure and the length of hospital stay as the secondary outcome measure. Results: In total, 76% of cases had good recovery at discharge (GOS, 5), 19% had moderate disability (GOS, 4), and 5% had severe disability (GOS, 3). The mean length of hospital stay was 11.2 days (range, 1-121 days). The most severely injured body region was the limbs (29.1%) and vertebral/spinal injuries were most common (33%) in terms of location. A significant difference (P<0.05) existed in GOS across sports groups, with motor sports having the lowest GOS. However, no significant differences (P>0.05) were found in other health-outcome variables or injury patterns across sports or activity groups, although more competitive sports cases (67%) required admission than recreational sports cases (33%). Conclusions: Spinal injuries are the most frequent sports injuries, bear the worst health outcomes, and warrant better preventive measures. Head injuries previously dominated the worst outcomes; this change is likely due to better preventive and management modalities. Competitive sports had a higher injury frequency than recreational sports, but no difference in health outcomes or injury patterns.

An Analysis of the Composite Discharge Capacity Effect with GCP Method (GCP공법의 복합통수능 효과 분석)

  • Park, Minchul;Kwon, Hyukchan;Shin, Hyohee;Jang, Gisoo;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.12
    • /
    • pp.37-46
    • /
    • 2011
  • An application frequency of vertical drainage method is increasing as an effective consolidation acceleration method. PBD method is most frequently used as a consolidation acceleration method in vertical drainage methods. PBD is economical and easy to operate but has some problems those are an environmental pollution and a decrease of a discharge capacity caused by bending of drainage materials when it is used in great depth. SCP method was frequently used because it's discharge capacity was good but now it is rarely used because of an increase of the material price because of an order imbalance. As the way to solve these problems, GCP method has been to the fore. For analyzing the effect of GCP method on the discharge capacity, three types of composite discharge capacity tests are done by using GCP, SCP and PBD respectively with the circle case, ${\phi}38{\times}h70cm$. On the contrary to this, GCP shows the worst discharge capacity for a decrease of the void ratio and the clogging phenomenon caused by increasing load. Also to figure out the clogging range of GCP, the clogging of GCP is checked in each load stage with a large case($1.0m{\times}0.5m{\times}1.1m$) which has clear acrylic front face. The diameter of GCP was 35cm and a clogging phenomenon occurred in 10% approximately. The result shows that the discharge capacity of GCP was given the lowest value for a decrease of the void ratio and the clogging phenomenon causing by increasing load. And the clogging phenomenon mostly occurred within 10% of GCP's diameter range.

Numerical modeling of seawater flow through the flooding system of dry ocks

  • Najafi-Jilani, A.;Naghavi, A.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.1 no.2
    • /
    • pp.57-63
    • /
    • 2009
  • Numerical simulations have been carried out on the flooding system of a dry located at the south coasts of Iran. The main goals of seawater flow haracteristics in the intake channels conditions of the flooding system are imposed in the modeling. The upstream boundary condition is the tidal fluctuations of sea water level. At the downstream, the gradually rising water surface elevation in the dry described in a transient boundary condition. The numerical results are compared with available laboratory a good agreement is obtained. The seawater discharge through the flooding system and the required time to filling up the dry dock is determined at the worst case. The water current velocity and pressure on the rigid boundaries are discussed.

Offsite Consequence Modeling for Evacuation Distances against Accidental Hydrogen Fluoride (HF) Release Scenarios (Hydrogen Fluoride (HF) 누출 사고 시 피해 범위 예측 및 장외영향평가를 위한 모델링 활용 방법)

  • Kim, Jeonghwan;Jung, Seungho
    • Korean Chemical Engineering Research
    • /
    • v.54 no.4
    • /
    • pp.582-585
    • /
    • 2016
  • This study intends to provide initial evacuation distances for the public in case of accidental releases of hydrogen fluoride (HF). HF is a very toxic chemical that is widely used in the chemical, electrical, and electronics industries. Consequence modeling programs, such as ALOHA and PHAST, were used to help formulate a contingency plan in case of an HF leak. For the purpose of this study, the release of entire quantity of HF in 10 min is defined as a worst-case scenario and the release from a partial line rupture is used as an alternative case scenario as National Institute of Chemical Safety (NICS) guidelines. Once the discharge rates were calculated based on the scenarios, the ERPG-2 endpoint distances have been obtained for representative daytime and nighttime weather conditions. This paper presents graphs that can be used to enact swift evacuation orders and emergency response plans in the case of accidental releases of HF.

The Study on the Implementation and Design of Power Supply Unit of Digital Communication Satellite (디지털위성중계기용 전원공급기 설계 및 구현에 대한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.9
    • /
    • pp.855-860
    • /
    • 2016
  • This study describes the design and implementation of digital Payload power supply. We materialized the interface of the PLDIU and power supply of a satellite bus, and minimized the potential for the occurrence of such erroneous operation circuit ESD through the WCA of the space environment. We designed a reliable power supply through simulation for a TID according to the vibration generated during the launch and space radiation environment, and found no problem in the function and performance through the test space environment after production.

Risk Assessment and Safety Measures for Methanol Separation Process in BPA Plant (BPA 공장의 메탄올 분리공정에서 위험성 평가 및 안전대책)

  • Woo, In-Sung;Lee, Joong-Hee;Lee, In-Bok;Chon, Young-Woo;Park, Hee-Chul;Hwang, Seong-Min;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.22-28
    • /
    • 2012
  • For a methanol separation column of the BPA (Bisphenol A) plant, HAZOP (hazard and operability) assessment was performed and damage ranges were predicted from the accident scenarios for the fire and the explosion. As a result, the damage range of the jet fire was 20 m in the case of rupture of the discharge pipe (50 mm diameter) of safety valve, and that of the flash fire was 267 m in the case of catastrophic rupture. Also, the damage ranges of the unconfined vapor cloud explosion (UVCE) for the rupture of the discharge pipe and for the catastrophic rupture were 22 m and 542 m, respectively. For the worst case of release scenarios, safety measures were suggested as follows: the pressure instruments, which can detect abnormal rise of the internal pressure in the methanol separation column, should be installed by the 2 out of 3 voting method in the top section of the column. Through the detection, the instruments should simultaneously shut down the control and the emergency shut-off valves.

Energy Balance and Power Performance Analysis for Satellite in Low Earth Orbit

  • Jang, Sung-Soo;Kim, Sung-Hoon;Lee, Sang-Ryool;Choi, Jae-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.3
    • /
    • pp.253-262
    • /
    • 2010
  • The electrical power system (EPS) of Korean satellites in low-earth-orbit is designed to achieve energy balance based on a one-orbit mission scenario. This means that the battery has to be fully charged at the end of a one-orbit mission. To provide the maximum solar array (SA) power generation, the peak power tracking (PPT) method has been developed for a spacecraft power system. The PPT is operated by a software algorithm, which tracks the peak power of the SA and ensures the battery is fully charged in one orbit. The EPS should be designed to avoid the stress of electronics in order to handle the main bus power from the SA power. This paper summarizes the results of energy balance to achieve optimal power sizing and the actual trend analysis of EPS performance in orbit. It describes the results of required power for the satellite operation in the worst power conditions at the end-of-life, the methods and input data used in the energy balance, and the case study of energy balance analyses for the normal operation in orbit. Both 10:35 AM and 10:50 AM crossing times are considered, so the power performance in each case is analyzed with the satellite roll maneuver according to the payload operation concept. In addition, the data transmission to the Korea Ground Station during eclipse is investigated at the local-time-ascending-node of 11:00 AM to assess the greatest battery depth-of-discharge in normal operation.