• Title/Summary/Keyword: Workplace Illuminance

Search Result 4, Processing Time 0.021 seconds

A Fundamental Study on the Photosensor Modeling for the Daylight Responsive Dimming System - Using RADIANCE Program (광센서 조광제어시스템에서의 광센서 모델링에 관한 기초적 연구 -RADIANCE 프로그램 활용-)

  • Hong, Seong-Kwan;Park, Byoung-Chul;Choi, An-Seop;Lee, Jeong-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.97-100
    • /
    • 2008
  • The daylight responsive dimming system is an energy saving system that automatically controls lighting output of artificial lighting according to available daylight in inside, as well as keeps uniform workplace illuminance. The basic three components of the daylight responsive dimming system consist of a photosensor, a controller and a dimming ballast. This paper is a fundamental study of photosensor modeling for the daylight responsive dimming system. The correlation between photosensor illuminance on the ceiling and workplace illuminance is an important factor to accuracy of system performance, so that the purpose of this study is to improve accuracy for daylight responsive dimming system. This study performs to derive the optimized conditions of photosensor using the RADIANCE.

  • PDF

An Experimental Study of the Optimum Spatial Characteristics and Location of Photosensor for Daylight Responsive Dimming Systems (광센서 조광제어시스템의 광센서 최적 방향성과 위치에 관한 실험적 연구)

  • 정봉근;최안섭
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.8-14
    • /
    • 2003
  • The daylight responsive dimming system, which uses daylight and automatically controls the light output of electric lighting according to the amount of 3.vailable daylight, is an energy saving system Successful performance relies on how photosensor signal can precisely represent workplace illuminance. However, it is not accurately identified due to the dynamic nature of the sun and the sky changed with respect to different seasons or time. The purpose of this research is to identify the correlation between workplace illuminance and photosensor signals, and propose an optimal location and spatial characteristics of the photosensor through experiments, which minimizes the above impacts and improve system performance.

A Study on lighting Energy Conservation in a Small Office Space with Daylight Dimming Control System (소규모 사무공간에서 디밍제어를 이용한 조명에너지 절약에 관한 연구)

  • 김한성;김강수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.15-21
    • /
    • 2003
  • This paper presents field measurements on daylighting and electric lighting with dimming controlled systems for a small office in Seoul, Korea. And the main purpose of this study is to provide the evaluation data of lighting energy performance when a dimming system is installed. For the performance evaluation, the mock-up room(3.6x7.2x2.6[m]) was used for the actual test. The results of this study were as follows; 1) The correlation between daylight illuminance at a workplane(Ed) and the photosensor signal(Sd) was an important factor affecting the performance of daylight responsive dimming system, 2) The mock-up office space gained a sufficient workplace illuminance of 579[lux] with the dimming control system 3) About 53[%J of monthly lighting energy could be saved using the dimming control system.

A Study on the Evaluation of Lighting Performance in an Office Space (사무공간의 조명성능 평가에 관한 연구)

  • 김한성;김영민;김강수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.16-22
    • /
    • 2003
  • The purpose of this study was to provide visual evaluation data in a workstation space when different lighting types were applied. For the performance evaluation, Radiance program was used for simulations, and the mock-up room(15.0x11.6x3m) was used for the actual test. The results of this study were as follows; 1) When the inidirect lighting simulation data using Radiance was compared with the actual data in a small workstation space, there was a 6.5% difference. Therefore, Radiance program was proved to be useful for the evaluation of lighting performance. 2) Higher light levels (higher light ratio (%)) were recorded in the straddled layout and lower light levels (lower light ratio (%)) were recorded in the centered layout condition in most cases. 3) Also, the results show that the indirect luminaires and the straddled layouts provide higher uniformity, whereas the direct luminaires and the centered layouts have lower uniformity.