• Title/Summary/Keyword: Working fluid ratio

Search Result 176, Processing Time 0.022 seconds

The Effect of the Fill Charge Ratio on the Heat Transfer Characteristics of a Two-Phase Closed Thermosyphon (충전율의 변화가 밀폐형 2-상 열사이폰의 열전달 특성에 미치는 영향에 관한 연구)

  • Park, Yong-Joo;Hong, Sung-Eun;Kim, Chul-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.12
    • /
    • pp.1646-1654
    • /
    • 2002
  • A two-phase closed thermosyphon was one of the most effective devices in the removing heat because of its simple structure, thermal diode characteristics, wide operating temperature range and so on. In this study, a two-phase closed thermosyphon(working fluid PFC(C6F14), container copper(inner grooved surface)) was fabricated with a reservoir which can change the fill charge ratio. The experiments were performed in the range of 50~600W heat flow rate and 10~70% fill charge ratio. The results were compared with some correlations that were presented by Rohsenow and Immura et al. in the evaporator, by Nusselt, Gross and Uehara et al. in the condenser and by Cohen and Bayley, Wallis, Kutateladze and Faghri et al. in heat transfer limitation etc.. The heat transfer coefficient at the evaporator increased with the input power. However the effect of the fill charge ratio was nearly negligible. At the condenser, it showed an opposite trend to the evaporator and with increase of the fill charge ratio, showed some enhancement of heat transfer. The heat transport limitation was occurred by the dry-out limitation for small fill charge ratio(10%) and presented about 100W. For the case of large fill charge ratio(Ψ$\geq$40%), it was occurred by the flooding limitation at about 500W.

Performance Test of Low Temperature Waste Heat Recovery Heat Exchanger Using Self-excited Oscillating Heat Pipe (자려 진동형 히트 파이프를 이용한 저온 폐열 회수 열교환기의 성능 실험)

  • 이욱현;이종현;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.853-859
    • /
    • 2000
  • In this study, low temperature waste heat recovery heat exchanger was developed using a principle of self-excited oscillating heat pipe. The heat exchanger of serpentine type was composed of extruded flat aluminum tube with 6 channels (3 nm$\times$ 2.75nm) and louvered fin. The heat transfer area density of heat exchanger was $331.9 m^2/m^3$. Working fluid is R141b and charge ratio was 40% by volume. Heat transfer rate and the effectiveness of heat exchanger was primary concern of this study. As a result, the effectiveness of heat exchanger was about 0.4-0.67, and recovered waste heat rate was about 4.5 kW per one unit of heat exchanger.

  • PDF

Effect of the Nozzle Curvature on Critical Flows (임계노즐 유동에 미치는 노즐 곡률의 영향)

  • Kim, Jae-Hyung;Kim, Heuy-Dong;Park, Kyung-Am
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.331-336
    • /
    • 2002
  • Recently the critical nozzles with small diameter are being extensively used to measure mass flow in a variety of industrial fields and these have different configurations depending on operation condition and working gas. The curvature radius of the critical nozzle throat is one of the most important configuration factors promising a high reliability of the critical nozzle. In the present study, computations using the axisymmetric, compressible, Navier-Stokes equations are carried out to investigate the effect of the nozzle curvature on critical flows. The diameter of the critical nozzle employed is D=0.3mm and the radius of curvature of the critical nozzle throat is varied in the range from 1D to 3D. It is found that the discharge coefficient is very sensitive to the curvature radius(R) of critical nozzle, leading to the peak discharge coefficient at R = 2.0D and 2.5D, and that the critical pressure ratio increases with the curvature radius.

  • PDF

An Experimental Investigation of Side-Orifice Effects on Pressure Drop for Single-Phase Flow

  • Seo, Kyong-Won;Chun, Moon-Hyun;Nam, Ho-Yun;Park, Seok-Ki;Lee, Yong-Bum
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.295-300
    • /
    • 1996
  • To investigate the effects of the side-orifice on the pressure drop for single-phase flow, a series of experiments have been carried out with 16 different downstream test sections with various combinations of side-orifice shapes, different numbers of side-orifices, and different arrangements of the side-orifice using water as a working fluid. From the measurements of the pressure drop and the flow rate, the pressure loss coefficient of the side-orifice(s) has been evaluated. Based on the total number of 529 present data, an empirical correlation for the pressure loss coefficient has been developed in terms of Reynolds number and geometric parameters, such as area ratio, equivalent diameter, leading edge, and average width of side-orifice.

  • PDF

Simulation of HFC organic Rankine cycles for geothermal power generation (지열발전을 위한 HFC 유기랭킨 사이클의 시뮬레이션)

  • Baik, Young-Jin;Kim, Min-sung;Chang, Ki-Chang;Yoon, Hyung-Kee;Lee, Young-Soo;Ra, Ho-Sang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.569-572
    • /
    • 2009
  • In this study, HFC ORCs (Organic Rankine Cycles) are investigated for a low-temperature geothermal power generation by a simulation method. A steady-state simulation model is developed to analyze and optimize cycle's performance. The model contains a turbine, a pump, an expansion valve and heat exchangers. The turbine and pump are modelled by an isentropic efficiency. Simulations were carried out for the given heat source and sink inlet temperatures, and given flow rate that is based on the typical power plant thermal-capacitance-rate ratio. 3 HFC fluids are considered as a candidate for a working fluid of low-temperature ORCs. In this study, all optimized HFC ORCs are shown to yield almost the same performance in terms of power for a low-temperature heat source of about $100^{\circ}C$.

  • PDF

The combustion characteristics of catalytic combustor with preheating heat exchanger (예열용 열 교환식 촉매연소기의 연소특성에 관한 실험)

  • Yu, Sang-Phil;Seo, Yong-Suk;Song, Kwang-Sup;Ryu, In-Su
    • 한국연소학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.79-84
    • /
    • 2002
  • The catalytic heat exchanger was designed which employs the regenerative preheating system of combustion air. The characteristics of the catalytic heat exchanger have been experimentally studied at the various operating parameters. The results showed that the mixture velocity did not affect significantly the performance of catalytic combustor whereas the preheating temperature of combustion air affected significantly the conversion rate. The complete conversion was achieved in the catalyzed honeycomb at a preheating temperature of $370-390^{\circ}C$, a mixture velocity of 0.53 $^{\sim}$ 0.75 m/s and an equivalence ratio of 0.19 $^{\sim}$ 0.27. The heat exchange efficiency of the catalytic heat exchanger appeared to be about 75 % when the air of room temperature was used as a working fluid. The results showed that both the heat balance of the system and the mixture conditions determine its stable catalytic combustion.

  • PDF

An Investigation on Operating Characteristics of the Closed Cycle System Using High Pressure Diesel Engine (고압 디젤엔진을 이용한 폐회로 시스템의 운전특성에 관한 고찰)

  • 김인교;박신배
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.65-72
    • /
    • 2002
  • The closed cycle diesel system is operated in closed circuit system where there is non air breathing with working fluid consists of combination of oxygen, argon and recycled exhaust gas far obtaining underwater or underground power sources. Experimental apparatus using the MTU8V183SE92 high pressurized engine adapted for closed cycle running, capable of operating at the system pressure of maximum 5 bar is constructed with ACAP as data acquisition system in order to operate equally in the open cycle in surface or the closed cycle in submerged conditions. The general features and the characteristics of combustion of HP(high pressure) diesel engine, specially designed and manufactured only for CCDE, are investigated. The test results of performance of HP diesel engine in closed cycle system are presented with respect to power and boost pressure and compared with those of low pressure diesel engine. The oxygen concentration and specific heat ratio are investigated with its deviation

Study of the Linear Compressor Characteristics of The Stirring Refrigerator (스터링 냉동기의 선철압축기 운전특성에 관한 연구)

  • 홍용주;박성제;김효봉;고득용;김종학;유병건
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.2
    • /
    • pp.49-54
    • /
    • 2001
  • The purpose of this study is to analyze the characteristics of the linear compressor for Stirling refrigerator. To ensure high performance and long life of the FPFD(Free Piston. Free Displacer) type Stirling refrigerator, the operating parameters of the linear compressor should be optimized. The experimental results show that the operating frequency of the linear compressor has significant effect on the input power characteristics. and that the compressor with higher charging pressure of working fluid has high pressure ratio. For the high performance of the linear compressor. compressor should be operated at the resonance frequency with respect to the given charging pressure.

  • PDF

Effects of Pad Number on the Static Performances of Large Tilting Pad Journal Bearings (패드 수의 변화가 대형 틸팅패드 저어널 베어링의 정특성에 미치는 영향)

  • Kim Sung-Gi;Kang Ji-Hoon;Kim Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.20 no.6
    • /
    • pp.330-336
    • /
    • 2004
  • In this paper, thermohydrodynamic characteristics of large tilting pad journal bearings which have $3\~8$ tilting pads were numerically analyzed. The turbulent lubrication equation and the energy equation were solved. The regime of operation of this bearing is laminar, turbulent and transitional. Also viscosity of working fluid was considered as function of only temperature and inlet pressure build-up was considered. Numerical results for a large tilting pad journal bearing showed pressure distribution, temperature distribution, eccentricity ratio, and friction torque. The effects of pad number on the static performances of a large tilting pad journal bearing are discussed.

Analysis of The Operation of a Low Temperature Differential Model Stilting Engine (저온도차 모형 스터링 엔진의 작동 해석)

  • Kim, Jung-Kuk;Shim, Kyung-Yong;Jung, Pyung-Suk
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.199-204
    • /
    • 2000
  • A low temperature differential model stirling engine is manufactured, and its operation characteristics are measured and analyzed by SIMPLE analysis model, in which heat transfer processes are simply considered. The heat transfer coefficients between working fluid and heat sources in the analysis are estimated by comparing the P-V diagrams by experiment and by analysis. This result may be very useful for further design and manufacture of model Stilting engines as well as real engines because it provides a comparatively correct predictions of the operation conditions and power output. It will be also conveniently used as an educational material for mechanical engineering students because it can be a nice example of optimal design process to decide the phase angle and compression ratio of engine design with a simple but realistic simulation.

  • PDF