• Title/Summary/Keyword: Working Mode

Search Result 300, Processing Time 0.024 seconds

The Performance Characteristics of Heat Pump Using the Refrigerant Subcooling (냉매 과냉각을 이용한 열펌프 시스템의 성능 특성)

  • Roh, Geon-Sang;Son, Chan-Ghyo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.4
    • /
    • pp.413-421
    • /
    • 2007
  • In this paper, the performance characteristics of heat pump system using a new refrigerant subcooling system designed for the study, are introduced. The new heat pump system have the ice storage tank at the outlet of condenser. The experimental apparatus is a well-instrumented water/water heat pump which consisted of working fluid loop, coolant loop, and ice storage tank. The experiment parameters of subcooling ranged as the evaporating temperature from $-5^{\circ}C$ to $8^{\circ}C$, the condensing temperature from $30^{\circ}C$ to $35^{\circ}C$. The test of the ice storage was carried out at evaporating temperature of $-10^{\circ}C$ and the ice storage mode is Ice-On-Coil type. The working fluid was R-22 and the storage materials were city-water. The test results obtained were as follows; The refrigerant mass flow rate and compressor shaft power were unchanged by the degrees of subcooling, that is, they were independent of degrees of subcooling. The cooling capacity of the new heat pump system increase as the evaporating temperature and subcooling degrees increase and is higher by $25{\sim}30%$, compared to the normal heat pump system. The COP of the new heat pump system increases as the degrees of subcooling and evaporating temperature increase and is higher by 28% than that of the normal heat pump system.

An Experimental Study on a Rectangular Parallelepiped Sodium Heat Pipe for High Temperature Class Forming (고온 유리 성형 공정을 위한 직육면체형 Sodium 히트파이프의 실험 연구)

  • Park, Soo-Yong;Boo, Jun-Hong;Kim, Jun-Beom
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1622-1629
    • /
    • 2002
  • To enhance isothermal characteristics of glass-farming surface, a rectangular parallelepiped heat pipes was fabricated, tested, and analyzed. The working fluid was sodium and the wall material was stainless steel 304. The dimension of the heat pipe was 210 (L) $\times$ 140(W) $\times$ 92(H)mm. A lattice structure covered with screen mesh was inserted to promote return of working fluid. The bottom side of heat pipe was heated electrically and the top side was cooled by liquid circulation. The temperature distribution at the bottom surface was of major concern and was monitored to determine isothermal characteristics. A frozen start-up of rectangular parallelepiped liquid metal heat pipe was tested. The operating mode of the sodium heat pipe was affected by the temperature of cooling zone, input heat flux, and the operating temperature of heat pipe. The heat pipe operated in a normal fashion as long as the heat flux was over 5.78W/cm$^2$, and the inside wall temperature of condenser part was above 95$^{\circ}C$ The maximum temperature difference at the bottom surface was observed to be 32$^{\circ}C$ when the operating temperature of the heat pipe was operating normally around 50$0^{\circ}C$. The result showed that a sodium heat pipe was very effective in reducing significantly the temperature difference in the glass-forming surface.

A Study on Electro-optical Characteristics of the Ion Beam Aligned FFS Cell on a Inorganic Thin Film (무기 박막을 이용한 이온빔 배향 FFS 셀의 전기광학특성에 관한 연구)

  • Hwang, Jeoung-Yeon;Park, Chang-Joon;Jeong, Youn-Hak;Kim, Kyung-Chan;Ahn, Han-Jin;Baik, Hong-Koo;Seo, Dae-Shik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.10
    • /
    • pp.1100-1106
    • /
    • 2004
  • In this paper, we intend to make fringe-field switching (FFS) mode cell by the ion beam (IB) alignment method on the a-C:H thin film, to analyze electro-optical characteristics in this cell. We studied on the suitable inorganic thin film for fringe-field switching (FFS) cell and the aligning capabilities of nematic liquid crystal (NLC) using the alignment material of a-C:H thin film as working gas at 30 W rf bias condition. A high pretilt angle of about 5 $^{\circ}C$ by ion beam (IB) exposure on the a-C:H thin film surface was measured. Consequently, the high pretilt angle and the good thermal stability of LC alignment by the IB alignment method on the a-C:H thin film surface as working gas at 30 W rf bias condition can be achieved. An excellent voltage-transmittance (V -T) and response time curve of the IE-aligned FFS-LCD was observed with oblique IB exposure on the a-C:H thin films. Also, AC V-T hysteresis characteristics of the IB-aligned FFS-LCD with IE exposure on the a-C:H thin films is almost the same as that of the rubbing-aligned FFS cell on a polyimide (PI) surface.

The Effect of a Piezoelectric Ultrasonic Scaler with Curette Tip on Root Substitute Removal in Vitro (큐렛형 팁을 장착한 압전방식 초음파 치석제거기가 치근대체물 삭제에 미치는 영향)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.429-442
    • /
    • 2000
  • Based on current evidence in the literature, it is known that endotoxin is a weakly adherent surface phenomenon and that power-driven instruments can be used to accomplish definitive root detoxification and maximal wound healing without overinstrumentation of root and without extensive cementum removal. And one of the newly developed curette tips used with low power of piezoelectric ultrasonic scaler, is effective to remove calculus and not to remove the excessive cementum. The purpose of this study is therefore, to assess the influence of ultrasonic power and various working parameters on root substitute removal when instrumentation is performed with the curette tip on piezoelectric ultrasonic scaler. This study assessed defect depth, width and area resulting from instrumentation using a piezoelectric ultrasonic scaler with a curette type tip in vitro to acrylic resin block as a root substitute. The working parameters was standardized by the sledge device which controls lateral force(0.5 N, 1 N, 2 N) and instrumentation time(5 sec, 10 sec, 20 sec) and power setting was adjusted 0,2,4,8 in P mode. Power setting had the greatest influence on defect depth compared to lateral force and instrumentation time(standardized regression parameter estimates${\pm}$standard error, $0.37{\pm}0.02$, $0.19{\pm}0.02$, $0.07{\pm}0.02$). The effects on defect area also greatest for power setting($0.57{\pm}0.03$) compared to lateral force and instrumentation time($0.33{\pm}0.03$, $0.12{\pm}0.03$). The effect of the power setting on the defect width($0.15{\pm}0.01$) is not so great as defect depth or defect area compared to lateral force($0.12{\pm}0.01$) and effect of instrumentation time is minimal($0.02{\pm}0.01$). It could be concluded that the power setting has the greatest influence on the defect depth and area in curette type tip with low power of piezoelectric ultrasonic device. Many parameters can be adjusted in various situation in clinical use of piezoelectric ultrasonic scaler but the power setting is the first parameter to be adjusted.

  • PDF

Values of travel time reliability (통행시간 신뢰성 가치 산정에 관한 연구)

  • Chang, Justin Su-Eun;Kang, Ji-Hye
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.6
    • /
    • pp.133-142
    • /
    • 2008
  • The term, travel time reliability, refers to variations in journey time that travelers cannot predict. This issue has been one of the main research topics in transport studies. This paper, especially, investigates the value of travel time reliability. The marginal substitution rate method is suggested as the way for the valuation and travelers' stated preference data are collected based on a choice experiment. A mode choice model is estimated using the data surveyed. The parameters of travel costs and travel time reliability from the model are used to calculate the marginal substitution rate that is interpreted as the value of travel time reliability. The value is arranged by travel areas of intercity and urban trips and by journey purposes of working and non-working types. The result of this research is expected to be helpful of conducting more cautious economic feasibility studies of transport schemes.

Development of a Database Program for Management Planning in National Forests (국유림(國有林) 관리(管理) 영림계획(營林計劃) 운영(運營)을 위(爲)한 데이터베이스 프로그램의 개발(開發))

  • Park, Eunsik;Chung, Joosang
    • Journal of Korean Society of Forest Science
    • /
    • v.88 no.1
    • /
    • pp.63-72
    • /
    • 1999
  • In this study, a relational database program to manage the data involved in forest planning was developed in such a way to simulate the whole process of 'Younglim' planning in Korean National Forest System. Using the pull-down menu system of various functions required for developing 'Younglim' plan, the database program can handle the data of forest inventory, 10-year working plans, annual working plans and the history of forest operations automatically and simultaneously. The model was designed to run under the environment of Korean version of Windows 95. Visual Basic 5.0 was used as the basic tool for programming and Microsoft ACCESS as the basic engine of the database system. In this paper, the process of designing the structure of database program following the process of 'Younglim' plan and the structure of the model are discussed. In addition, the functions of menu system are presented using the screen-mode output windows of the model.

  • PDF

Performance Analysis of Solar Thermal System with Heat Pump for Domestic Hot Water and Space Heating (온수 급탕 및 난방을 위한 히트 펌프 태양열 시스템의 성능 분석)

  • Sohn, Jin-Gug
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.5
    • /
    • pp.49-62
    • /
    • 2018
  • This study aims to analyze the performance of solar thermal system with heat pump for domestic hot water and heat supply. There are four types of system. Systems are categorized based on the existence of a heat pump and the ways of controlling the working fluid circulating from the collector. Working fluid is controlled by either temperature level (categorized as system 1 and 2) or sequential flow (system 3 and 4). Heat balance of the system, the solar fraction, hot water and heating supply rates, and performance of heat pump are analyzed using TRNSYS and TESS component programs. Technical specifications of the main facilities are as follow; the area of the collector to $25m^2$, the volumes of the main tank and the buffer tank to $0.5m^3$ and $0.8m^3$, respectively. Heating capacity of the heat pump in the heating mode is set to 30,000 kJ / hr. Hot water supply set 65 liters per person each day, total heat transfer coefficient of the building to 1,500 kJ / kg.K. Indoor temperature is kept steadily around $22^{\circ}C$. The results are as follows; 6 months average solar fraction of system 1 turns out to be 39%, which is 6.7% higher than system 2 without the heat pump, indicating a 25% increase of solar fraction compared to that of system 2. In addition, the solar fraction of system 1 is 2% higher than that of system 3. Hot water and heating supply rate of system 1 are 93% and 35%, respectively. Considering the heat balance of the system, higher heat efficiency, and solar fraction, as whole, it can be concluded that system 1 is the most suitable system for hot water and heat supply.

Wideband and 2D vibration energy harvester using multiple magnetoelectric transducers

  • Yang, Jin;Yu, Qiangmo;Zhao, Jiangxin;Zhao, Nian;Wen, Yumei;Li, Ping
    • Smart Structures and Systems
    • /
    • v.16 no.4
    • /
    • pp.579-591
    • /
    • 2015
  • This paper investigates a magnetoelectric (ME) vibration energy harvester that can scavenge energy in arbitrary directions in a plane as well as wide working bandwidth. In this harvester, a circular cross-section cantilever rod is adopted to extract the external vibration energy due to the capability of it's free end oscillating in arbitrary in-plane directions. And permanent magnets are fixed to the free end of the cantilever rod, causing it to experience a non-linear force as it moves with respect to stationary ME transducers and magnets. The magnetically coupled cantilever rod exhibits a nonlinear and two-mode motion, and responds to vibration over a much broader frequency range than a standard cantilever. The effects of the magnetic field distribution and the magnetic force on the harvester's voltage response are investigated with the aim to obtain the optimal vibration energy harvesting performances. A prototype harvester was fabricated and experimentally tested, and the experimental results verified that the harvester can extract energy from arbitrary in-plane directions, and had maximum bandwidth of 5.5 Hz, and output power of 0.13 mW at an acceleration of 0.6 g (with $g=9.8ms^{-2}$).

Stoichiometry of $Ns^+/Ca^{2+}$ Exchange Quantified with Ion-selective Microelectrodes in Giant Excised Cardiac Membrane Patches

  • kang, Tong Mook;Hilgemann, Donald W.
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 2003.06a
    • /
    • pp.30-30
    • /
    • 2003
  • Without a definitive resolution of stoichiometry of cardiac Na$^{+}$-Ca$^{2+}$exchange (NCX), we cannot proceed to any quantitative analysis of exchange function as well as cardiac excitation-contraction coupling. The stoichiometry of cardiac NCX, however, is presently in doubt because reversal potentials determined by various groups range between those expected for a 3-to-1 and a 4-to-1 flux coupling. For a new perspective on this problem, we have used ion-selective microelectrodes to quantify directly exchanger-mediated fluxes of $Ca^{2+}$and Na$^{+}$in giant membrane patches. $Ca^{2+}$- and Na$^{+}$-selective microelectrodes, fabricated from quartz capillaries, are placed inside of the patch pipettes to detect extracellular ion transients associated with exchange activity. Ion changes are monitored at various distances from the membrane, and the absolute ion fluxes through NCX are determined via simulations of ion diffusion and compared with standard ion fluxes (Ca$^{2+}$ fluxes mediated by $Ca^{2+}$ ionophore, and Na$^{+}$ fluxes through gramicidin channels and Na$^{+}$/K$^{+}$pumps). Both guinea pig myocytes and NCX1-expressing BHK cells were employed, and for both systems the calculated stoichiometries for inward and outward exchange currents range between 3.2- and 3.4-to-1. The coupling ratios do not change significantly when currents are varied by changing cytoplasmic [Ca$^{2+}$] or by adding cytoplasmic Na$^{+}$. The exchanger reversal potentials, measured in both systems under several ionic conditions, range from 3.1- to 3.3-to-1. Taken together, a clear discrepancy from a NCX stoichiometry of 3-to-1 was obtained. Further definitive experiments are required to acquire a fixed number, and the present working hypothesis is that NCX current has an extra current via ‘conduction mode’.ent via ‘conduction mode’.

  • PDF

Development of Economic based Optimal Operation Program for Microgrid (경제성 기반의 마이크로그리드 최적운영 프로그램 개발)

  • Lee, Hak-Ju;Cha, Woo-Ku;Song, Il-Kun;Yoon, Yong-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.106-114
    • /
    • 2009
  • This paper addresses unit commitment for microgrid optimization including renewable energy sources, working under deregulated power market. As microgrid supplies both heat and electricity for consumer, operational optimization must be done to meet their demand economically. So renewable energy sources are considered to be negative load, and batteries are used as the load flattening device to raise possibly operational function. In the state of solution, the program is developed to solve out the maximum profit of microgrid using dynamic programming method. Finally, its validity is verified through case study in isolation mode and interconnected mode. The S/W will be used to operate microgrid economically after the market of microgrid is formed.