• 제목/요약/키워드: Working Hour

Search Result 309, Processing Time 0.029 seconds

Hospital oral and maxillofacial nursing care in Jeju province (제주 지역 병원의 구강 악안면 간호 실태)

  • Kim, Sung-Joon;Kim, Se-Il;Song, Hyo-Jeong;Kahm, Se-Hoon;Lee, Byoung-Jin
    • The Journal of the Korean dental association
    • /
    • v.53 no.1
    • /
    • pp.36-46
    • /
    • 2015
  • Objectives: The objective of this work was to investigate the hospital nursing care of oral and maxillofacial health in jeju province. Methods: 438 Registered nurses(RN) who were working at each of secondary hospitals in Jeju province had responded to the questionnaire. The data were analyzed via frequency analyses and one-way ANOVA to assess the state of RN on hospital nursing care of oral and maxillofacial health. Results: The class of education on density in formal density that marked '0 hour' and '1-3 hours' were 73.5% and 19.9%, respectively. The class of refresher training on density that marked '0 hours' and '1-3 hours' were 92.9% and 6.6%, aggregately 99.5%. The nursing education on appearance after tumor of maxillofacial area that marked 'formal education' and 'none' were 45.2% and 52.1%, respectively. The score of question 'function, effect and side effect of hexamedin gaggle' was $2.68{\pm}0.95$ by Likert 5-point scale. Likewise, the scores were $2.82{\pm}0.88$ on question 'management of removal denture', $2.83{\pm}0.95$ on question 'preventive dental treatment before anticancer therapy', $2.88{\pm}0.86$ on question 'function of saliva', $2.96{\pm}0.99$ on question 'oral management of tube feeding patient', $3.13{\pm}1.00$ on question 'bacterial endocarditis from oral microflora', $3.36{\pm}0.89$ on question 'dysphagia' and $3.62{\pm}1.03$ on question 'aspiration pneumonia'. RN replied that 'lack of knowledge' and 'delay of cooperation' formed 53.7% and 33.3% respectively, on question 'problem in dental consultation other diseased patient'. Conclusions: From this study, it is necessary for RN and student of nursing science to be educated on the oral and maxillofacial nursing. Authors suggest further co-study and nation-wide research.

A Study on Estimation of Human Damage Caused by Rupture of Butane Can (부탄 캔 파열로 인한 인체피해예측에 관한 연구)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Choi, Seong-Joo;Lee, Jong-Rark;Lim, Dong-Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.98-104
    • /
    • 2007
  • As the industrial society is highly developing, human need in daily life has also changed drastically. With the introduction of 40 hour working week system, more households enjoy picnics on weekends. More gas accidents take place on Saturdays and on Sundays than any other days of week. In this context, the Institute of Gas Technology Training in Korea Gas Safety Corporation carries out explosion experiment to make trainees to take all possible measure to ensure safe management of gas in the field by fully recognizing the hazards of gas explosion accidents. In this study, the influence of explosion over-pressure caused by the rupture of butane can thrown away after use was calculated by using the Hopkinson's Scaling Law and the accident damage was estimated by applying the influence on the adjacent people into the Probit model. The value of those away from 50 meters from the explosion site was 1.35kPa and the peak overpressure to thoes away from 25 meters directly was 3.2kPa. Those value was input to the PROBIT model, the estimation showed the sante result 0 percent of damage possibility.

Relationship between Occupational Stress and Work-related Factors in Dental Hygienists (치과위생사의 직무스트레스와 직무요인의 관계)

  • Lee, So-Young;Yu, Byeng-Chul
    • Journal of dental hygiene science
    • /
    • v.11 no.6
    • /
    • pp.553-562
    • /
    • 2011
  • This study was purposed to evaluate the level of occupational stress and the work-related factors of occupational stress in dental hygienists. The study was conducted during the period from May to October 2010 with study population consisted of 316 dental hygienists. The occupational stress was estimated with questionnaire of the Korean Occupational Stress Scale(KOSS) and the work-related factors were consisted with 9 work characteristics. Data analysis was performed with t-test, ANOVA and multiple regression analysis using SPSS(win ver 18.0) program. The level of occupational stress was $52.42{\pm}4.95$ in dental hygienists. The levels of sub-scales for occupational stress were $64.56{\pm}12.17$ in interpersonal conflict, $59.85{\pm}13.59$ in physical environment, $54.60{\pm}13.51$ in organizational system, $52.37{\pm}11.47$ in job demand, $51.71{\pm}10.58$ in lack of reward, $48.14{\pm}12.97$ in insufficient job control, $46.68{\pm}9.25$ in job insecurity, $41.46{\pm}15.98$ in occupational climate, respectively. According to multiple regression analysis, physical burden and daily repetitive working hour were work-related factors of occupational stress in dental hygienists. To conclude, the occupational stress in dental hygienists was higher than mean score of reference values of occupational stress in Korean workers and methods for reducing work load and work hours considering work characteristics of dental hygienist are needed to prevent occupational stress in dental hygienists.

AN ELECTROCHEMICAL STUDY ON THE CORROSION RESISTANCE OF THE VARIOUS IMPLANT METALS (수종 임플랜트 금속의 내식성에 관한 전기화학적 연구)

  • Jeon Jin-Young;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.423-446
    • /
    • 1993
  • Titanium and its alloys are finding increasing use in medical devices and dental implants. The strong selling point of titanium is its resistance to the highly corrosive body fluids in which an implant must survive. This corrosion resistance is due to a tenacious passive oxide or film which exists on the metal's surface and renders it passive. Potentiodynamic polarization measurement is one of the most commonly used electro-chemical methods that have been applied to measure corrosion rates. And the potentiodynamic polarization test supplies detailed information such as open circuit, rupture, and passivation potential. Furthermore, it indicates the passive range and sensitivity to pitting corrosion. This study was designed to compare the corrosion resistance of the commonly used dental implant materials such as CP Ti, Ti-6A1-4V, Co-Cr-Mo alloy, and 316L stainless steel. And the effects of galvanic couples between titanium and the dental alloys were assessed for their useful-ness-as. materials for superstructure. The working electrode is the specimen , the reference electrode is a saturated calomel electrode (SCE), and the counter electrode is made of carbon. In $N_2-saturated$ 0.9% NaCl solutions, the potential scanning was performed starting from -800mV (SCE) and the scan rate was 1 mV/sec. At least three different polarization measurements were carried out for each material on separate specimen. The galvanic corrosion measurements were conducted in the zero-shunt ammeter with an implant supraconstruction surface ratio of 1:1. The contact current density was recorded over a 24-hour period. The results were as follows : 1. In potential-time curve, all specimens became increasingly more noble after immersion in the test solution and reached between -70mV and 50mV (SCE) respectively after 12 hours. 2. The Ti and Ti alloy in the saline solution were most resistant to corrosion. They showed the typical passive behavior which was exhibited over the entire experimental range. Therefore no breakdown potentials were observed. 3. Comparing the rupture potentials, Ti and Ti alloy had the high(:st value (because their break-down potentials were not observed in this study potential range ) followed by Co-Cr-Mo alloy and stainless steel (316L). So , the corrosion resistance of titanium was cecellent, Co-Cr-Mo alloy slightly inferior and stainless steel (316L) much less. 4. The contact current density sinks faster than any other galvanic couple in the case of Ti/gold alloy. 5. Ag-Pd alloy coupled with Ti yielded high current density in the early stage. Furthermore, Ti became anodic. 6. Ti/Ni-Cr alloy showed a relatively high galvanic current and a tendency to increase.

  • PDF

Analysis of Network Traffic with Urban Area Characteristics for Mobile Network Traffic Model (이동통신 네트워크 트래픽 모델을 위한 도시 지역 이동통신 트래픽 특성 분석)

  • Yoon, Young-Hyun
    • The KIPS Transactions:PartC
    • /
    • v.10C no.4
    • /
    • pp.471-478
    • /
    • 2003
  • Traditionally,, analysis, simulation and measurement have all been used to evaluate the performance of network protocols and functional entities that support mobile wireless service. Simulation methods are useful for testing the complex systems which have the very complicate interactions between components. To develop a mobile call simulator which is used to examine, validate, and predict the performance of mobile wireless call procedures must have the teletraffic model, which is to describe the mobile communication environments. Mobile teletraffic model is consists of 2 sub-models, traffic source and network traffic model. In this paper, we analyzed the network traffic data which are gathered from selected Base Stations (BSs) to define the mobile teletraffic model. We defined 4 types of cell location-Residential, Commercial, Industrial, and Afforest zone. We selected some Base Stations (BSs) which are represented cell location types in Seoul city, and gathered real data from them And then, we present the call rate per hour, cail distribution pattern per day, busy hours, loose hours, the maximum number of call, and the minimum number of calls based on defined cell location types. Those parameters are very important to test the mobile communication system´s performance and reliability and are very useful for defining the mobile network traffic model or for working the existed mobile simulation programs as input parameters.

A Study on the Reasonable Personnel Management of Radiology Department -Centering around the General Hospitals in Seoul- (진단방사선과(診斷放射線科)의 적정인력(適正人力) 관리(管理)에 관(關)한 연구(硏究) -서울시내 종합병원(綜合病院) 중심(中心)으로-)

  • Chung, Soon-Kuy
    • Journal of radiological science and technology
    • /
    • v.11 no.2
    • /
    • pp.27-64
    • /
    • 1988
  • Most hospital administrators in our country have doubted whether or not the size of their hospital personnel staffs, and the personnel management styles implemented are efficient or not. Actually, increased personnel expenditures due to sophisticated specialization of medical practices has become the biggest hospital expense. Therefore, it is said that hospitals can be run move efficiently by implementing reasonable management strategies for hospital personnel management. In this paper, the departments of diagnostic radiography in 16 general hospitals in Seoul, which were classified into 4 groups by the scale of hospital beds, were used as sample cases. Then, the data for the number of X-ray examination by diagnostic item was collected from sample hospitals. The unit hour spent on X-ray examinations in each diagnostic service was quoted from "A Study on setting-up of the relative value units of medical services and on the structure of current fee schedules" written by Mr. Ik Je Seong. The data analysis results are as follows; First, the number of hours per day spent on X-ray examinations in 13 hospitals out of 16 hospitals, was shorter than the general daily working hours (8 hours). Second, in the morning there was not enough time to work for X-ray examinations required, with the available manpower. In the afternoon, however, the situation was diametrically opposed to that in the morning. Third, in light of above results, though most hospitals employ sufficient personnel for the quantity of the actural work, they were always short-handed where their works were performed Fourth, this study tells us that there is a maldistribution of the work in the schedule : too much work for the available personnel in the morning. The following recommendations are resulted from the data analysis described above. First, it is recommended that all out-patients coming again, except specific patients(G. B. or I.V.P. etc) who have to have their X-ray examinations on an empty stomach in the morning among out-patients, be required to visit the hospital in the afternoon. Second, it is recommended that all new out-patients be required to make a reservation in order to equalize the number of patients throughout the day. Third, it is recommended that all in-patients, except specified patients, be arranged to have their X-ray examinations in the afternoon. Fourth, it is recommended that part time workers be employed during peak hours. This recommendation, if applied in a wider scale, would allow hospitals to overcome the problem of the maldistribution of work and personnel, and then more efficient hospital management through the appropirate personnel management procedures could be expected.

  • PDF

A Study on Temperature Analysis for Smart Electrical Power Devices (스마트 전력 기기의 온도 분석에 관한 연구)

  • Vasanth, Ragu;Lee, Myeongbae;Kim, Younghyun;Park, Myunghye;Lee, Seungbae;Park, Jwangwoo;Cho, Yongyun;Shin, Changsun
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.8
    • /
    • pp.353-358
    • /
    • 2017
  • An electrical power utility, like an electrical power pole, includes various kinds of sensors for smart services. Temperature data is considered one of the important factors that can influence the smart operations of this utility. This study suggests a method for temperature data analysis for deciding the status of the smart electrical power utilities by using Kalman Filter and Ensemble Model. The suggested approach separates the temperature data according to the different positions of the temperature sensors of a utility, then uses Kalman Filter and Ensemble Model to analyse the characteristics of the temperature variation. With detailed processes, method explains the variation between an external temperature factor like weather temperature data and the sensed temperature data, and then, analysis the temperature data from each position of electrical power utilities. In this process, the suggested method uses Kalman Filter to remove error data and the ensemble model to find out mean value of every hour of electrical data. The result and discussion of temperature analysis were described clearly with the analysed results of electrical data. Finally, we were able to check the working condition of the power devices and the range of the temperature data foe each devices, which may help to indicate any causalities with respect to the devices in the utility pole.

The Relationship between Quitting Time and Subsequent Time Allocation of Full-time Workers in Korea (전일제 임금근로자의 퇴근시간과 일과 후 생활시간의 관계)

  • Lee, Seungho;Park, Mijin
    • 한국사회정책
    • /
    • v.24 no.1
    • /
    • pp.117-151
    • /
    • 2017
  • This study explored the relationship between quitting time and subsequent time allocation of full-time workers with young children. First, as a result of sub-group difference analysis of subsequent time allocation by quitting time, the group who finished their work early used their additional time mostly for housework and care work. And if the workers finish their work late, they decreased their housework and active leisure time first, and then supplementally reduced their care work and passive leisure time. In addition, SUR analysis showed that as the workers finish their work earlier, the proportion of housework, care work and active leisure among five activities was getting higher. Last but not least, it was verified that the relationship between the quitting time and the subsequent time allocation was moderated by gender in housework, care work, and regenerative activity. This research can contribute to the development of debate on work-life balance of workers' by providing the concrete and detailed results.

A Study of the Employment Condition and Labour Experience of Elementary After-School Care Teachers: A Case of Gwangju Metropolitan City (초등돌봄교사의 고용형태와 노동경험에 관한 연구: 광주광역시 사례를 중심으로)

  • Kim, Hyun Mi;Shin, Julia Jiwon
    • 한국사회정책
    • /
    • v.23 no.2
    • /
    • pp.141-172
    • /
    • 2016
  • This study examines the employment conditions and labour experience of elementary after-school care teachers in South Korea. Based on the empirical data collected through in-depth interviews with after-school care teachers in Gwangju Metropolitan City, the study considers multifaceted problems faced by after-school care teachers in their workplace. The after-school care class is part of educational policies initiated and rapidly expanded by the Ministry of Education, resulting in the substantial increase of non-regular school workers. The irregularization of after-school care teachers illustrates that the common problems faced by female non-regular workers, such as social discrimination, exclusion and inequality, are also transplanted into the typical public sector. In the case of Gwangju Metropolitan City, during the past two years there have been evident increases both in under 15-hour short time contract care teachers and outsourcing of care classes. Temporary part-time contract care teachers suffer relentless job insecurity and experience poor working conditions, exclusion and discrimination within the workplace and labour alienation. In order to minimize the organized resistance of care teachers, school authorities implicitly individualize and isolate care teachers through hierarchization, the division of labour and the spatial division of classes between indefinite and temporary contract teachers.

A Point of Production System for Semiconductor Wafer Dicing Process (반도체 웨이퍼 다이싱 공정을 위한 생산시점 정보관리시스템)

  • Kim, In-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.10
    • /
    • pp.55-61
    • /
    • 2009
  • This paper describes a point of production(POP) system which collects and manages real-time shop floor machining information in a wafer dicing process. The system are composed of POP terminal, line controller and network. In the configuration of the system, LAN and RS485 network are used for connection with the upper management system and down stratum respectively. As a bridge between POP terminal and server, a line controller is used. The real-time information which is the base of production management are collected from information resources such as machine, product and worker. The collected information are used for the calculation of optimal cutting condition. The collection of the information includes cutting speed, spout of pure water, accumulated count of cut in process for blade and wafer defect. In order to manage machining information in wafer dicing process, production planning information is delivered to the shop floor, and production result information is collected from the shop floor, delivered to the server and used for managing production plan. From the result of the system application, production progress status, work and non-working hour analysis for each machine, and wafer defect analysis are available, and they are used for quality and productivity improvements in wafer dicing process. A case study is implemented to evaluate the performance of the system.