• Title/Summary/Keyword: Working Device

Search Result 556, Processing Time 0.027 seconds

An Exploration of Various Evaluation Methods to Improve Usability of Museum Mobile Device

  • Ahn, Mi-Lee;Cha, Hyun-Jin;Hwang, Yun-Ja;Kim, Hee-Jin
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.6
    • /
    • pp.765-773
    • /
    • 2011
  • Objective: This study aims towards exploring a model of the HCI evaluation methods to improve the usability of mobile device, based on a case of a Mobile PDA system in a Museum context. Background: Mobile PDA systems in a Museum context is widely utilized for the educational purposes, but it is criticized for low usability that the device only play a role in textbooks on legs without any interactive educational activities. Therefore, the usability improvements on the mobile PDA system should be considered. Method 1: This model was developed with a combination of the expert review and the user testing, and with a combination of the qualitative and quantitative studies. In more details, first of all, a qualitative study was conducted as a combination of three different methods: 1) expert review with heuristics, 2) interviews with persons working in a museum, and 3) contextual enquiry. Results 1: The experts review provided with critical usability issues, and the semi-constructive interview helped to understand the background of the mobile device. Lastly, the contextual enquiry showed user experience problems and directions of improving the device from user's perspective. Method 2: Based on the results of the qualitative study, a questionnaire was designed. Results 2: The analysis of the quantitative study was conducted to generalize the problems, and prioritize the direction of improving the device within the limitation of the cost and time in a museum. Conclusion: This study has implications in developing an example of a HCI evaluation model to improve the user experience of the mobile device as well as finding problems and directions of how to improve the mobile PDA systems in the museum. Application: In fact, most of the studies related to the evaluation of the mobile device have been conducted in a laboratory context due to the cost and time. This paper, however, attempted to apply to various HCI research techniques from different constituents in real context.

The Effect of a Piezoelectric Ultrasonic Scaler with Curette Tip on Casting Gold Removal in Vitro (큐렛팁을 장착한 압전방식 초음파치석제거기의 작업조건에 따른 치과주조용 합금의 삭제에 관한 연구)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.3
    • /
    • pp.531-542
    • /
    • 2001
  • Periodontal debridement is most important procedure in periodontal treatment, because periodontal disease is the biofilm infection. The use of ultrasonic instrument has many clinical advantages compared to classical hand instrument. The introduction of newly developed ultrasonic scaler tips made the use of ultrasonic scaler popular. However the study of tooth substance removal according to the working parameters of ultrasonic scaler with newly developed tips is not sufficient. The purpose of this study is to evaluate the effects of working parameters of piezoelectric ultrasonic scaler with curette tip on casting gold removal. The working parameters was standardized by the sledge device which controls lateral force(0.5 N, 1.0 N, 2.0 N) and power setting was adjusted 2, 4, 8 in P mode and S mode and instrumentation time was 5 seconds. The defect depth and width were measured with profile meter and defect surface was examined by SME. The depth of defect was significantly large in S mode( $39.58{\pm}19.35{\mu}m$) compared to P mode( $8.37{\pm}6.98{\mu}m$). There was significant decrease of depth of defect between 1.0N($32.87{\pm}27.18{\mu}m$) and 2.0N( $14.86{\pm}15.04{\mu}m$). The area of defect was also significantly large in S mode($4482.42{\pm}3551.71{\mu}m^2$) compared to P mode( $922.06{\pm}960.32{\mu}m^2$). There was significant decrease of area of defect between 1.0N($3889.12{\pm}3936.00{\mu}m$) and 2.0N( $974.66{\pm}986.01{\mu}m$). The change of mode did not effect on the width of the defect. The change of power setting did not effect on the depth, width, and area of defect. In spite of limitation of this study it could be concluded that the use of piezoelectric ultrasonic scaler with curette tip on S mode could make significant tooth substance loss.

  • PDF

A Study on Heat Transfer Characteristics of Helical Coiled Tube (나선코일의 열전달 특성에 관한 연구)

  • PARK, Jong-Un;CHO, Dong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.16 no.2
    • /
    • pp.257-270
    • /
    • 2004
  • The two-phase closed thermosyphon is a heat transfer device capable of transfer large quantities of heat from a source to a sink by taking advantage of the high heat transfer rates associated with the evaporation and condensation of a working fluid within the device. A study was carried out with the performance of the heat transfer of the thermosyphon having 50, 60, 70, 80, 90 internal micro grooves in which boiling and condensation occur. A plain thermosyphon having the same inner and outer diameter as the grooved thermosyphon is also tested for comparison. Water, methanol and ethanol have been used as the working fluids. The liquid filling as the ratio of working fluid volume to total volume of thermosyphon, the inclination angle, micro grooves and operating temperature have been used as the experimental parameters. The heat flux and the boiling and the condensation heat transfer coefficient and overall heat transfer coefficient at the condenser and evaporator zone are estimated from the experimental results. The experimental results have been assessed and compared with existing correlations. Imura's and Kusuda's correlation for boiling showed in good agreement with experimental results within ${\pm}20$% in plain thermosyphon. The maximum heat transfer rate was obtained when the liquid fill ratio was about 25%. The high heat transfer coefficient was found between 25o and 30o of inclination angle for water and between 20o and 25o for methanol and ethanol. The relatively high rates of heat transfer have been achieved in the thermosyphon with internal micro grooves. The micro grooved thermosyphon having 60 grooves shows the best heat transfer coefficient in both condensation and boiling. The maximum enhancement (i.e. the ratio of the heat transfer coefficients of the micro grooved thermosyphon to plain thermosyphon) is 2.5 for condensation and 2.3 for boiling.

A Study on the Safety and Health Management Plan of Subway Construction Workers using Macpa Stress Index (맥파 스트레스 지수를 활용한 도시철도 건설공사자의 안전보건관리 방안에 관한 연구)

  • Joung Sik, Chae;Yu Jeong, Lee;Jong bin, Lee;Seong Rok, Chang
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.102-107
    • /
    • 2022
  • South Korea will soon be a super-aged society, as more than 20.6% of its population will be 65 years and older by 2025. As of 2022, 17.5% of the total population in South Korea is 65 years and older, which exceeds the set threshold for an aged society, where more than 14% of the population is 65 years and older. The proportion of older subway construction workers has increased. Aging workers and their work stress negatively impact their workability. A previous study demonstrated that the stress index measured using the uBioMacpa measurement device (Macpa stress index) had a significant correlation with work stress in South Korea. The device tests vascular health and measures stress levels via Macpa signal analysis. In this study, the pulse waves of subway construction workers were measured using uBioMacpa to identify their stress levels. The stress levels were analyzed by age, years of service, job position, employment type, and work type. Herein, these statistics could not be easily represented by a normal distribution; therefore, the Kruskal-Wallis test, a nonparametric statistical method, was used for the analysis of data. The results showed that age, job position, employment type, and working type affected the Macpa stress index and the stress levels of workers increased with age. In terms of job position, technical engineers were more stressed than other workers because of their poor working environment. In terms of employment type, daily-wage workers were more stressed than other workers. In terms of working type, tunneling, waterproofing, and construction scored the highest Macpa stress indexes without any significant difference, whereas earthworks scored the lowest. Based on the analysis of Macpa stress index, safety and health management plans were proposed to reduce the stress levels of workers. Moreover, a manual for efficient stress management must be developed for subway construction workers.

Satellite Thermal Control Device Enhanced by Latent Heat of the Phase Change Material (응고/융해 잠열을 이용한 위성용 열제어장치의 실험적 연구)

  • Kim, Tae Su;Shin, Yoon Sub;Kim, Taig Young;Seo, Jung-gi;Hyun, Bum-Seok;Cheon, Hyeong Yul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.10
    • /
    • pp.887-894
    • /
    • 2016
  • The thermal control device using solid-liquid phase change material (PCM) is designed, manufactured, and experimented in thermal environment chamber. The n-Hexadecane is selected as a PCM and its melting point is placed within the component working temperature range. The PCM container is made of Al6061 and has the thermal spreading fins inside. To simulate the working condition for on-orbit satellite the heat pipes are used to connect the heater and radiator and the PCM thermal control device (PCMTD) is installed at the middle portion of heat pipes. The thermal buffer mass (TBM), which is same configuration and volume with PCMTD, is also manufactured to compare the thermal control performance. As a result, the PCMTD is not only more efficient than TBM in their temperature control features but both mass and power of compensation heater are reduced.

Study on the Satellite Thermal Control Hardware Composed of Two Parallel Channels Working for Heat Pipe and Phase Change Material (열관과 상변화물질을 일체형으로 병렬 배열한 위성용 열제어 부품 연구)

  • Kim, Taig-Young;Hyun, Bum-Seok;Lee, Jang-Joon;Rhee, Ju-Hun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.11
    • /
    • pp.1087-1093
    • /
    • 2010
  • The satellite thermal control H/W composed of two parallel channels working for heat pipe (HP) and phase change material (PCM) is suggested for the high heat dissipating component which works intermittently with short duty. In a limited point of view, the HP-PCM device is a kind of off-the-shelf component that requires no dedicated configuration and thermal designs to PCM. Therefore, it can be used with less impact on the program cost and schedule different from most of the PCM applications. In present study the typical honeycomb structure radiator applying the HP-PCM device is designed and the detail thermal math model is developed for numerical analyses. The result comparison between without and with PCM shows that the HP-PCM device redistributes the peak heat around the whole mission period through the alternate melting and freezing of PCM, and, as a result, the maximum and minimum temperatures are effectively alleviated. The drawback of PCM application due to low thermal conductivity can be successfully resolved by means of parallel arrangement of HP channel.

A Study on the Monitoring Technique for Musculoskeletal Safety Management and Implementation of the System (근골격계 안전관리를 위한 모니터링 기법에 관한 연구 및 시스템 구현)

  • Shin, Yeong-Ju;Joo, Ha-Young;Yang, Jin-Hong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.3
    • /
    • pp.267-276
    • /
    • 2020
  • Manufacturing workers are easily exposed to the risk of musculoskeletal disorders caused by repetitive tasks in their working environment. This is due to problems with occupational characteristics that repeatedly use the body. However, the current lack of monitoring systems for monitoring and prevention has led to an increase in workers' exposure to risks each year. This paper presents how to solve these problems in real working environment by producing wearable devices using IMU sensors. After wearing a wearable type device, the user's movement is judged through data analysis by receiving the rotation value according to musculoskeletal movement. At this time, the risk is determined by measuring the number of rotations of the user by eliminating bias and eliminating cumulative error, acquiring sophisticated data, and analyzing it in the form of dynamic threshold values. Using the wearable device proposed in this paper, the effect of this method could be checked through a web page measuring the number of rotations for elbow musculoskeletal disorders.

A Generic Interface for Internet of Things (IoT) Platforms (IoT 플랫폼을 위한 범용 인터페이스)

  • Kim, Mi;Lee, Nam-Yong;Par, Jin-Ho
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.7 no.1
    • /
    • pp.19-24
    • /
    • 2018
  • This paper presents an IoT platform of common interfaces that are flexible IoT applications and Connect the smart devices. The IoT platform includes automatic collaboration discovery the smart Device. It is different things case with connection each device through IoT Platforms are each device and application service. Due to these heterogeneities, it is quite advantages to develop applications working with derived IoT services. This circumstance needs the generic interface and results in a range of IoT architectures by not only the environments settings and discovery resource but also varied uniqe to implementation services working with IoT applications. Therefore, this suggestion of solve the problems and make it possible independent platforms always alive to connection with each devices based on the generic interface. The generic interface is heterogeneity-driven solve the problems and effectively contributions a platform that could be operated in diverse IoT Platforms.

Assessment of Volatile Organic Compound Reduction Using an Air Purification Facility in an Adhesive Handling Process (접착제 취급 작업장 내 공기정화 설비를 이용한 휘발성 유기화합물 저감 평가)

  • Jaemin Woo;Dongjun Kim;Jihun Shin;Gihong Min;Chaekwan Lee;Wonho Yang
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.2
    • /
    • pp.78-88
    • /
    • 2023
  • Background: Exposure to volatile organic compounds (VOCs) can have acute and chronic health effects on human beings in general and in working environments. In particular, VOCs are often emitted in large quantities in industrial settings. In such circumstances, there is a need to improve the indoor air quality at workplaces. Objectives: The purposes of this study were to verify the effectiveness of air cleaning devices in workplaces and provide alternative solutions for improving working environments. Methods: Personal exposure and area level of VOCs for workers were evaluated in a car-part adhesive process before and after installing an air cleaning device with a TiO2-coated filter. Passive samplers and direct reading instruments were used to collect and analyze the VOCs, and the removal efficiency and improvement of air quality were evaluated. We also calculated the exposure index (EI) to assess the risk level in the workplace. Results: The removal efficiency for VOCs through the installation of the air cleaning device was approximately 26.9~69.0% as determined by the concentration levels before and after installation. The measured substances did not exceed the exposure limits for the work environment and the EI was less than 1. However, carcinogenic substances such as benzene, formaldehyde, carbon tetrachloride, and trichloroethylene were detected. Conclusions: The application of an air cleaning device can be a solution for controlling the indoor air quality in a workplace, particularly in cases where ventilation systems cannot be installed due to process limitations.

According to the User's Device Selection Priority Automatic Algorithm (사용자 기기 선택에 따른 우선순위 자동 설정 알고리즘)

  • Jeong, Do-Hyeong;Choi, Hyung-Wook;Jang, Ki-Man;Jeong, Dae-Jin;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.891-892
    • /
    • 2016
  • Recent research has become a smart home for operating the joining operation of the relationships between the device progress. However, Existing systems, there is a problem that the efficiency of the work can be degrade by the interference occurs when the operation of the other device, and triggered if the device is operating. In this paper, we designed a priority automatically set algorithm according to a user selection device to solve this problem. The user selects the device used by the application and by comparing between devices, select whether or not to set the priority of the tasks in. This allows the user can configure the working environment of only the desired device, and less chance of interference from other devices that are not selected during the work in progress can expect a more efficient productivity.

  • PDF