Thermally Simulated Current of Corona-Charged PVDF Film (코로나 대전된 PVDF 필름의 열자격 전류)

  • Kim, C.H.;Kim, G.Y.;Hong, J.W.;Lee, J.U.
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.489-491
    • /
    • 1987
  • It has been shown that the thermally stimulated current technique can be one of the most powerful methods for evaluating the electrical properties. An unstretched $\alpha$-form specimen of corona-charged, 50[${\mu}m$],t Polyvinylidene Fluoride shows four TSC peaks designated $\delta}$, $\gamma$, $\beta$ and $\alpha$ in assending order of temperature in temperature range $-100{\sim}200^{\circ}C$. The $\delta$, $\gamma$ peaks may be attributed to the dipolar depolarization in the amorphous regions and $\beta$, $\alpha$ peaks are associated with the detrap from trapped carriers in the crystalline regions.

  • PDF

Removal of NOx by Pulsed Streamer discharge (펄스 스트리머 방전을 이용한 NOx 제거)

  • 고희석;박재윤;김건호
    • Electrical & Electronic Materials
    • /
    • v.10 no.8
    • /
    • pp.807-811
    • /
    • 1997
  • In this paper we have investigated the removal characteristics of NOx by pulsed corona discharge with a multi-pointplane electrode where a magnetic field is applied in the discharge region. The efficiency of NOx removal was measured and analyzed as a function of pulse frequency gas flow rate NOx initial concentration magnetic flux density. In this result the highest removal efficiency of NOx was obtained at the following operating conditions; the frequency =400[Hz] gas flow =1[$\ell$/min] initial concentration= 400[ppm] and magnetic flux density=0.36[T].

  • PDF

Ultrasonic Noises in Power Transformer (전력용 변압기에서의 초음파 노이즈)

  • Kweon, D.J.;Jung, G.J.;Choi, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2305-2307
    • /
    • 1999
  • Partial discharge measurement using a ultrasonic technique allows us to detect degradation of the electrical insulation in a power transformer. However, The ultrasonic measurement studies don't offer a good solution in operating conditions. In this paper, we investigated characteristics of ultrasonic noise caused by a 345kV power transformer under operating conditions. The ultrasonic noises generated by corona in air, vibration of core, pump and fan, etc. An ultrasonic frequency caused by corona in air was appeared 9 and 18[MHz] at the outside wall of the transformer. And a spectra of core vibration was detected below 2.5[kHz]. These spectrum were compared with 20 $\sim$ 200[kHz] of the internal partial discharge in the model transformer.

  • PDF

Polymer Surfaces for Cell Adhesion I. Surface Modification of Polymers and ESCA Analysis (세포적합성 고분자 표면에 관한 연구 I. 고분자 표면 개질과 ESCA 분석)

  • 이진호;강길선
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.43-52
    • /
    • 1989
  • We modified polymer surfaces, polyethylene, polystyrene and polyester, to improve cellcompatibility. For surface modification of the polymers, we used various surface treatment methods; physicochemical oxidation methods such as plasma discharge, corona discharge, sulfuric acid and chloric acid treatments, and biological methods such as adsorption of plasma protein and fibronectin onto the polymer surfaces. The treated polymer surfaces were characterized by electron spectroscopy for chemical analysis ( ESCA ). The physicochemically treated polymers showed different surface chemical structures depending on the treated methods. The sulfuric acid-treated surfaces showed greater carboxyl groups than those of plasma- or corona- treated surfaces, while the chloric acid-treated one showed high density of hydroxyl group on the surface. By the biological treatments, the surfaces were uniformly coated with proteins. The fibronectin adsorbed on the surface seems to have unique properties for cell binding.

  • PDF

Evidence of Molecular Rearrangement in Benzyl-type Radicals

  • Yoon, Young-Wook;Lee, Seung-Woon;Lee, Sang-Kuk
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.10
    • /
    • pp.2783-2785
    • /
    • 2010
  • Searching for new molecular radicals which are believed to play an important role as reaction intermediates in aromatic chain reactions, we have applied the technique of corona excited supersonic expansion employing a pinhole-type glass nozzle to obtain the vibronic spectrum from the corona discharge of precursor 3,5-difluorotoluene with a large amount of inert carrier gas helium. An analysis of the observed spectrum revealed that many vibronic bands are from other isomeric difluorobenzyl radicals generated in the jet by migration of the fluorine atom or methylene group to the adjacent position in the 3,5-difluorobenzyl radical. A possible mechanism was proposed for the formation of other isomers by using a bridged cyclic intermediate structure.

CORONAL TEMPERATURE AS AN AGE INDICATOR

  • Sung, Hwan-Kyung;Bessell, M.S.;Sana, Hugues
    • Journal of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • The X-ray spectra of late type stars can generally be well fitted by a two temperature component model of the corona. We find that the temperatures of both components are strong functions of stellar age, although the temperature of the hotter plasma in the corona shows a larger scatter and is probably affected by the activity of stars, such as flares. We confirm the power-law decay of the temperature of the hot plasma, but the temperature of the cool plasma component decays linearly with log(age).

Environmental effects by corona discharge from a 765kV double circuit transmission line (765kV 2회선 송전선의 코로나 방전에 의한 환경영향 연구)

  • 김정부;이동일;신구용;양광호;안희성;구자윤
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.451-455
    • /
    • 1996
  • This paper specified the measurement results conducted by the Korea Electric Power Research Institute (KEPRI) 765kV double circuit transmission test line that measured the audible noise, hum noise, radio interference, electric field and aeolian measurement. This test line consists of 6-480mm$^{2}$ conductors per phase. The analysis of the test results shows that this 6-Rail conductor bundle satisfies the audible noise criterion under the stable rainy weather condition and the radio interference level under the fair weather. And the other items are also agreed with the design level criterion. (author). 9 refs., 7 figs., 2 tabs.

  • PDF

Development of Audible Noise Prediction Formulas Applied to HVAC Transmission Lines Design by Using Genetic Programming (유전프로그래밍에 의한 초고압 송전선로 환경설계용 코로나 소음 예측계산식 개발)

  • Yang, Kwang-Ho;Hwang, Gi-Hyun;Park, June-Ho;Park, Jong-Keun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.5
    • /
    • pp.234-240
    • /
    • 2001
  • Audible noise (AN) produced by corona discharges from high voltage transmission lines is one of the more important considerations in line design. Therefore, line designers must pre-determine the AN using prediction formulas. This paper presents the results of applying evolutionary computation techniques using AN data from lines throughout the world to develop new, highly accurate formulas for predicting a A-weighted AN during heavy rain and stable rain from overhead ac lines. Calculated ANs using these new formulas and existing formulas are compared with measured data.

  • PDF

Considerations on the TF Map using Partial Discharge Pulse Characteristics (부분방전 펄스특성을 이용한 TF Map에 대한 고찰)

  • Kim, Jeong-Tae;Kim, Nam-Joon;Chang, Yong-Moo;Kim, Ji-Hong;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2126-2128
    • /
    • 2005
  • In this paper, it was investigated the applicability of TF analysis for the discrimination of air corona in on-site PD measurement. For the purpose, single and multiple discharges combined with oil discharges and air corona were generated and measured by use of artificial models and HFPD pulse detector. Through the TF analysis, data clusters could be classified each other in the TF Map, even in the case of multiple discharges. Therefore, it is known that TF analysis could be applied for the improvement of on-site PD measurement.

  • PDF

2019 Total Solar Eclipse Expedition of KASI

  • Bong, Su-Chan;Yang, Heesu;Lee, Jae-Ok;Kim, Jinhyun;Jeon, Young-Beom;Jang, Bi-Ho;Seough, Jungjoon;Park, Young-Deuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.69.2-69.2
    • /
    • 2020
  • Korea Astronomy and Space Science Institute (KASI) is developing a coronagraph to measure the coronal electron density, temperature, and speed utilizing spectral change of the K-corona around 400 nm. However, near UV light is more affected by atmospheric effect on the ground than visible light. For the total solar eclipse on July 2 2019, KASI organized an expedition team to test the possibility of the similar measurement scheme in the visible light. The observation site was in Las Flores, San Juan, Argentina. We built an imaging spectrograph using micro lenslet array and grism, named Coronal Integral Field Spectrograph (CorIFS). In addition, images of white light corona, wide field background, and all sky were taken with various camera settings. We present the preliminary results of the expedition.