• Title/Summary/Keyword: With-Corona

Search Result 828, Processing Time 0.03 seconds

A NON-SPHERICAL MODEL FOR THE HOT OXYGEN CORONA OF MARS

  • KIM YONG HA;SON SUJEONG;YI YU;KIM JHOON
    • Journal of The Korean Astronomical Society
    • /
    • v.34 no.1
    • /
    • pp.25-29
    • /
    • 2001
  • We have constructed a non-spherical model for the hot oxygen corona of Mars by including the effects of planetary rotation and diurnal variation of the Martian ionosphere. Exospheric oxygen densities are calculated by integrating ensemble of ballistic and escaping oxygen atoms from the exobase over the entire planet. The hot oxygen atoms are produced by dissociative recombination of $O^+_2$, the major ion in the Martian ionosphere. The densities of hot oxygen atoms at the exobase are estimated from electron densities which have been measured to vary with solar zenith angle. Our model shows that the density difference of hot oxygen atoms between noon and terminator is about two orders of magnitude near the exobase, but reduces abruptly around altitudes of 2000 km due to lateral transport. The diurnal variation of hot oxygen densities remains significant up to the altitude of 10000 km. The diurnal variation of the hot oxygen corona should thus be considered when the upcoming Nozomi measurements are analyzed. The non-spherical model of the hot oxy-gen corona may contribute to building sophisticate solar wind interaction models and thus result in more accurate escaping rate of oxygens from Mars.

  • PDF

Deflective Behavior of Charged Particles in a Two-Stage Electrostatic Precipitator

  • Lim, Hun-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.83-91
    • /
    • 2011
  • Even if smoke, fumes, mist or dust particles are removed by electrostatic precipitators (ESPs), the occurrence of ozone, which is harmful to human body, has to be severely restricted in the indoor environments of hospitals, offices, and workshops. Therefore, the two-stage ESP generating positive corona at the ionizer is typically used because it creates less ozone than the two-stage ESP generating negative corona at the ionizer. In order to predict the collection performance and the optimal design of the two-stage ESP applied to positive high-voltage, particle concentration is experimentally investigated in this paper. In addition, particle motion within the collector section is also numerically analyzed. The positive corona discharge current of the ionizer is found to be affected by the applied voltage in the collector section but less so by the particle concentration. Particle concentration shows a minimum near the high voltage electrode of the collector section. The minimum value of the collection efficiency is almost proportional to gas velocity. When the collector length decreases, the minimum value of the collection efficiency increases. Charged particles entering the collector region are linearly deflected towards the grounded plate by an electric field. From the above experimental and numerical results, two empirical equations on the concentration ratio and the collection efficiency are derived, and are in good agreement with the experimental data.

1-Dimensional Simulation of the Corona Discharge using Fluid Method (유체법을 이용한 코로나 방전의 1차원 수치해석)

  • 이용신;심재학;고광철;강형부
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.172-176
    • /
    • 1997
  • It is likely that the corona discharge appears due to the motion and the multiplication of electron and ion under the nonuniform electric field. Because the motion and the multiplication of electron and ion are the function of electric field, for the simulation of the corona discharge, we have to calculate the electric field, before the calculation of the motion and the multiplication of electron and ion. In this paper, the electric field is calculated on the assumption that the gap between a hyperboloidal needle and a plane is 1-dimension, and the motion and the multiplication of electron and ion are determined by Flux-Corrected Transport method. For this purpose, we solve the electron and ion continuity equation together with Poisson equation. We calculated the current density and the electron and ion density distributions between electrodes as well as electric field distortion due to the space charge assuming that the discharge channel radius is 100${\mu}{\textrm}{m}$. In this simulation, it is found that the current density has one peak as observed by experiment, and electric field distortion is important to the formation and the stability of the corona discharge.

  • PDF

Study of Characteristics of Corona Discharge Plasma in a Wire-Cylinder Type Reactor (Wire-Cylinder형 반응로에서의 코로나 방전 플라스마의 특성 연구)

  • 박승자;박인호;고욱희
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.3
    • /
    • pp.132-138
    • /
    • 2004
  • We used the self-consistent one-dimensional model applied to FCT algorithm and FEM method in a wire-cylinder type reactor to study the characteristics of corona discharge plasma in air at the atmospheric pressure. At the pulsed do voltage and do voltage, we studied the changes of the characteristic of plasma by computing electron density profile according to the changes of voltage and the size of reactor. The changes of active radius from this result are compared with the data of Peek's. The numerical simulation results for a corona discharge plasma explain the physical mechanism of the discharge process and could be used to obtain the optimized parameters for designing the plasma reactor for pollution abatement.

Surface Properties and Adhesion of Semiconducting and Insulating Silicone Rubber by Corona Discharge Treatment (코로나 방전처리에 의한 반도전-절연 실리콘 고무의 표면특성 및 접착특성)

  • Lee, Ki-Taek;Hwang, Sun-Mook;Hong, Joo-Il;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.9
    • /
    • pp.868-872
    • /
    • 2006
  • In this work, the effects of the corona treatment on surface properties of semiconducting silicone rubber were investigated in terms of contact angles, ATR-FTIR(Attenuated total reflection fourier transform infrared spectroscopy) and XPS(X-ray photoelectron spectroscopy). And the adhesive characteristics were studied by measuring the T-peel strengths. Based on chemical analysis, the surface modification can be mainly ascribed to the creation of chemically active functional groups such as C-O, C=O and C-OH on semiconducting silicone surface. This oxidized rubber layer is inorganic silica-like structure of Si bound with three to four oxygen atoms ($SiOx,\;x=3{\sim}4$. The Corona treatment produces an increase in joint strength that is maximum for 10 min treatment. However, due to brittle property of this oxidized layer, the highly oxidized layer from too much extended treatment could be act as a weak point, decreasing the adhesion strength.

Corona declassified imagery for land use mapping: Application to Koh Chang, Thailand

  • Kusanagi, Michiro;Nogami, Jun;Chemin, Yann;Wandgi, Thinley Jyamtsho;Oo, Kyaw Sann;Rudrappa, Prasad Bauchkar;Hieu, Duong Van
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.891-893
    • /
    • 2003
  • This study uses the images from the Corona ‘spy’ satellite, which have been declassified in November 2002 and available on Internet order for a very low cost. The image used dates from 1973 and has about 6m panchromatic characteristics. Along with a Landsat5TM of 1990 and Aster of 2001, a temporal range of about 30 years is achieved. A simple classification of the area was processed and crosschecked manually from the available recent toposheets of Thailand. Results show the development of human infrastructure in the Protected Island of Koh Chang in Thailand, from 1973 to date. Specific human locations are identified linked either to tourism development, or to villages of fishermen. Scope for using Corona in land cover changes on a longer time period than usual satellite images is possible. Some classification issues coming from the sensor have to be taken into account. Accuracy assessment is also an issue because of the age of the sensor.

  • PDF

Ultrasonic Signal Detection in a Transformer Through Noise Elimination (변압기내 노이즈제거를 통한 초음파 신호 검출)

  • 박현수;곽희로;박중신
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.231-234
    • /
    • 2000
  • The corona in oil, the surface discharge in oil, the void discharge which could be in a transformer were imitated by using three electrodes with different shapes and the frequency bands of each ultrasonic signal were measured. After emitting artificial noises toward the transformer, only ultrasonic signals were extracted by frequency filtering, from the ultrasonic signals with noises at partial discharge. As a result, it was confirmed that the ultrasonic signals due to the corona in oil, the surface discharge in oil, the void discharge could be distinguished from the noises.

  • PDF

Considerations on the TF Anal,ysis using Partial Discharge Pulse Characteristics in Oil (유중 부분방전 펄스 특성을 이용한 TF 분석에 대한 고찰)

  • Kim, Jeong-Tae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.508-514
    • /
    • 2005
  • In this paper, it was investigated the characteristics of PD(partial discharge) pulse shapes in oil and the possibility of TF(Time-Frequency) analysis for the discrimination of air corona in on-site PD measurement of oil transformers. For the purpose, single and multiple discharges combined with oil discharges and air corona were generated and measured by use of artificial models through the HFPD pulse detector and the oscilloscope. PD pulse shapes were different according to the type of defects, especially including air corona- pulses. Also, through the TF analysis, data clusters could be classified each other in the TF Map, even in the case of multiple discharges. Therefore, it is known that TF analysis could be aprlied for the improvement of on-site PD measurement in oil transformers.

Analysis on NOX Removal Efficiencies and Particle Growth Using Pulsed Corona Discharge Reactor (펄스 코로나 방전 반응기를 이용한 NOX 제거 효율 및 입자 성장 분석)

  • Park, Jung-Hwan;Kim, Dong-Joo;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.155-161
    • /
    • 2001
  • In this study, we analyzed the $NO_X$ removal efficiency and particle size distribution by the pulsed corona discharge process and investigated the effect of several process variables. The NO removal efficiencies and the particle characteristics were measured and analyzed as the function of initial concentrations of NO, $H_2O$, and $NH_3$, applied voltage, pulse frequency and residence time. As the frequency of applied voltage increases, or as the applied voltage increases or as the residence time increases, the NO removal efficiency increases. The change of initial $NH_3$ and $H_2O$ concentrations do not affect the NO removal efficiency significantly. The particle concentration and size increases with the increases of initial NO concentration, residence time and applied voltage.

  • PDF

A Study on the NOx Removal Rate by Arrangement of Discharge Electrode in Pulsed Corona Discharge Reactor (펄스 코로나 반응기에서 방전극의 배열에 따른 탈질율 연구)

  • Choi, Min;Park, So-Jin;Wi, Young-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.3
    • /
    • pp.315-323
    • /
    • 2003
  • The goal of this study if the optimization of discharge electrode for pulsed corona discharge reactor located in thermal power plant. For this purpose, we have performed experiments of NO$_{x}$ removal rate by exchange of discharge electrode diameter and arrangement of discharge electrode in the non -thermal plasma reaction facility using a ethylene as additive. If the diameter and numbers of discharge electrode were larger, the NO$_{x}$ removal rate was higher. From these results, if we optimized the shape and installed numbers of discharge electrode at the pilot plant, we could increase the NO$_{x}$ removal rate with less amount of additive than current amount.mount.