• 제목/요약/키워드: Wire rope

검색결과 120건 처리시간 0.032초

와이어 로프의 파단특성에 관한 실험적 연구 (An Experimental Study on the Fracture Characteristics of Wire Ropes)

  • 김종현;이근오;태순호
    • 한국안전학회지
    • /
    • 제9권4호
    • /
    • pp.3-10
    • /
    • 1994
  • This study examines fracture characteristics of wire rope of 6$\times$37+FC 14mm B degree, Which has been widely used for the strength support for machinery, cranes and shipping. The examination Is based on the fellowing experimental conditions. Firstly, this study analyzes the effect of the strength of wlre rope. When number of broken wires is occuring at the level of 5%, 10% and 15% degree respectively in the following two cases:1) Case of broken down to each strand equally. 2) Case of broken down to one strand only. Secondly, this study analyzes the effect of corrosion on the strength of wire rope. Corrosion times are 72hours, 144hours and 216hours corrosion respectively under following conditions. 1) Case of only a corrosion without wire breaking. 2) Case of corrosion after 5% degree wire breaking to each strand equally. Some outcomes of these experiment are as follows. 1) From the of tension test, We can find that the ratio of strength reduction case of wire broke down to one strand concentrically is greater than that ratio case of broke down to each strand equally. 2) From the corrosion test, We can also find that the ratio of strength reduction case of corroded after 5% degree wire breaking to each strand equally Is greater than that ratio case of corroded without wire breaking. 3) After comparing theoretical fracture load of wires with experimental fracture load of wires, we can find the fracture load of the case of broken down to each strand equally is most similar to theoretical fracture load. 4) It is proposed that safety rules on wire rope in the Industrial safety and healthy labor of law have to change “breaking over 10% of number of wires in one strand of wire rope(excluded filler wire )”has to be replaced by“breaking over 10% of number of all wires in all strand of wire rope(excluded filler wire)”

  • PDF

비 부착형 와이어로프로 보강된 철근콘크리트 보의 전단 거동 (Shear Behavior of Reinforced Concrete Beams Strengthened with Unbonded-Type Wire Rope Units)

  • 김선영;변항용;심재일;정헌수;양근혁
    • 콘크리트학회논문집
    • /
    • 제19권1호
    • /
    • pp.83-90
    • /
    • 2007
  • 본 연구에서는 와이어로프 단위를 이용한 철근콘크리트 보의 비 부착형 보강 공법을 제시하였다. 전단에서 파괴된 15개의 보가 제시된 보강 공법에 의해 보수, 보강 된 후 재 실험되었다. 주요 변수는 전단경간비, 와이어로프 단위의 초기 프리스트레스력, 배근 방법 및 간격이다. 실험 결과 제시된 와이어로프로 보강된 보들의 전단강도와 파괴 후 연성 거동이 원래 보의 것들에 비해 매우 향상되었다. 또한 수직 와이어로프보다는 경사 와이어로프가 내력 향상에 유리하였으며 와이어로프에 작용된 초기 프리스트레스의 증가는 콘크리트 스트럿에서 주 인장응력의 크기를 감소시킴으로서 사인장 균열내력을 향상시켰다. 보강된 보의 전단내력과 ACI 318-05 및 EC 2 설계기준과의 비교로부터 전단경간비 2.5 이하의 보강된 보들의 전단내력은 ACI 318-05 기준에 의해 적절히 평가될 수 있었다. 한편 EC 2는 전단경간비 2.5 이상인 보강된 보들에서 와이어로프의 전단 전달 능력을 과대평가하였다.

누설자속 탐상법 및 노이즈 필터를 이용한 와이어로프의 결함진단시스템 개발 (A Development of the Fault Detection System of Wire Rope using Magnetic Flux Leakage Inspection Method and Noise Filter)

  • 이영진;아미나;이권순
    • 전기학회논문지
    • /
    • 제63권3호
    • /
    • pp.418-424
    • /
    • 2014
  • A large number of wire rope has been used in various industries such as cranes and elevators. When wire used for a long time, wire defects occur such as disconnection and wear. It leads to an accident and damage to life and property. To prevent this accident, we proposed a wire rope fault detection system in this paper. We constructed the whole system choosing the leakage fault detection method using hall sensors and the method is simple and easy maintenance characteristics. Fault diagnosis and analysis were available through analog filter and amplification process. The amplified signal is transmitted to the computer through the data acquisition system. This signal could be obtained improved results through the digital filter process.

Wire Rope Isolator 마운팅 수동 조작 패널의 진동 저감 (Vibration Reduction for a Local Operation Panel Mounted by Wire Rope Isolator)

  • 김재실;김동일;허종대;황재덕
    • 한국기계가공학회지
    • /
    • 제13권6호
    • /
    • pp.127-133
    • /
    • 2014
  • This paper reviews a finite element model of a wire rope isolator (WRI) via an experimental comparison test. A local operation panel (LOP) mounted on a WRI is modeled using a finite element method. Mode analyses and harmonic analyses are conducted while varying of the thickness of the rope for the WRI. A feasible WRI can be selected considering the reduction of the vibration and the total weight of the LOP system.

Wire Rope형 진동완충장치 개발 (Development of Wire Rope Snubbers)

  • 박종범;안용호;배병홍;김민배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.334-336
    • /
    • 1999
  • Piping systems of the power generating stations have been generally protected by hydraulic and mechanical snubbers which can allow large displacements arising from temperature change while those can reduce or absorb stresses due to vibrations. However these snubbers require amounts of budget for maintenance or replacement because of the leakage, lubrication and finally short life cycle. Recently the snubbers consisted of wire rope have been proved to reduce vibrations of piping systems. While the wire rope snubbers are free of maintenance such as leakage and lubrication imported price are so high. Now it is necessary to design. manufacture and certificate these wire rope snubbers.

  • PDF

Wire Rope Dynamics 기반의 조선용 탑재 크레인 동역학 시뮬레이션 (Dynamic Simulation of a Shipbuilding Erection Crane based on Wire Rope Dynamics)

  • 차주환;구남국;노명일;이규열
    • 한국전산구조공학회논문집
    • /
    • 제25권2호
    • /
    • pp.119-127
    • /
    • 2012
  • 와이어 로프(wire rope)는 여러 가닥의 얇고 긴 철사를 감아서 밧줄과 같이 만든 것으로 굽힘과 비틀림 하중에 비해 축 하중에 더 크게 저항할 수 있는 특징을 가지고 있다. 해상 크레인, 갠트리 크레인, 크롤러 크레인 등과 같이 선박 또는 해양 구조물의 탑재를 위해 사용되는 조선용 탑재 크레인은 이러한 와이어 로프를 이용해 큰 중량의 블록들을 들거나 내리고 있다. 따라서 블록의 안전한 탑재를 위해서는 와이어 로프에 대한 동역학적 특성을 잘 파악해야 한다. 본 연구에서는 블록 탑재 시 크레인의 와이어 로프에 작용하는 장력과 비틀림 모멘트에 대한 계산식을 유도하고, 이를 기반으로 한 조선용 탑재 크레인의 동역학 시뮬레이션을 수행하였다. 그 결과, 개발된 시뮬레이션 방법이 실제 조선소의 안전한 블록 탑재 과정에 충분히 적용할 수 있음을 확인하였다.

An initial investigation of the inverted trussed beam formed by wooden rectangular cross section enlaced with wire rope

  • Gesualdo, F.A.R.;Lima, M.C.V.
    • Structural Engineering and Mechanics
    • /
    • 제44권2호
    • /
    • pp.239-255
    • /
    • 2012
  • This work presents a contribution to understand the inverted trussed beams behavior. The system has a main beam and struts with rectangular cross section associated to a wire rope enlaced to the main beam. It is an unpublished system with the advantage of easy positioning of the wire rope, once it is a continuous and connected by turnbuckles. It is a system that can be used as support for concrete formworks or for rehabilitation wooden beams proposal. The enlacement of the cable demands a small notch at the top of the cross section and a cross pin at the bottom. Six inverted trussed beams were tested, with spans of 180 cm with cables diameter of 1/4". Additionally, four simple beams without any external steel cable were also tested with material from the same lot of wood, allowing a comparison in rupture. The results showed capacity gain of around 60% compared to a simple beam. Once the wire rope characteristics and anchoring are very important for structure response, some improvement suggestions for the efficiency of the cables are also presented.

면역-유전알고리즘에 의한 Wire Rope의 굽힘강성도 동정 (Identification of Flexural Rigidity for Wire Rope Using Immune-Genetic Algorithm)

  • 최병근;양보석;길병래;이수종
    • 동력기계공학회지
    • /
    • 제2권1호
    • /
    • pp.52-58
    • /
    • 1998
  • An immune system has powerful abilities such as memory, recognition and learning to respond to invading antigens, and is applied to many engineering algorithm recently. In this paper, the combined optimization algorithm is proposed for multi-objective problem by introducing the capability of the immune system that controls the proliferation of clones to the genetic algorithm. The optimizing ability of the proposed algorithm is identified by using multi-peak function which have many local optimums and identification of the flexural rigidity for wire rope model.

  • PDF

Hall 센서를 이용한 엘리베이터 와이어 로프의 비파괴 검출시스템의 개발 (Development of Nondestructive Detecting System for Elevator Wire Ropes using Hall-effect Sensors)

  • 김성덕
    • 센서학회지
    • /
    • 제10권1호
    • /
    • pp.33-41
    • /
    • 2001
  • 와이어 로프는 무거운 중량을 안전하게 운반하거나 기계적인 에너지를 빠르게 전송하는 곳과 같은 산업응용 분야에 광범위하게 사용되어 왔다. 특히, 운전 중 엘리베이터의 와이어 로프가 파손되면 큰 재산 상 손실과 주변 인명의 심각한 상해를 초래할 수 있다. 따라서, 와이어 로프의 정기적인 검사는 매우 중요하다. 와이어 로프의 고장 검출은 로프의 구조, 특성, 결함 특성, 검출방법과 신호처리 방법에 대한 기본적인 이해가 요구된다. 이 연구에서는 엘리베이터에 노화된 와이어 로프에 대한 마모, 단선, 부식과 형붕괴와 같은 결함을 검출하기 위하여, Hall 센서를 결합한 새로운 결함 검출시스템의 개발에 대하여 다룬다. 휴대용 계측기로서 검출기를 사용하기 위하여, Hall 센서를 가진 센싱 부분과 아날로그 신호처리 및 프로그램의 제작에 대한 몇 가지 특성들이 서술되었다. 제작된 검출시스템에 대한 실험과 실장시험 결과 역시 제시되었다. 그 결과, 검출시스템은 사용 중인 노화된 와이어 로프의 결함을 검출하는데 양호한 효율성을 갖는다는 것을 확인하였다.

  • PDF

와이어로프를 적용한 고강도 철근콘크리트 기둥의 내화공법 및 하중비에 따른 내화성능에 관한 연구 (A Study on the Fire Resistance Performance Concerning Types of Fire Protection Method and Load Ratio of High Strength Concrete Column Using The Wire Rope)

  • 조범연;여인환;김흥열;김형준;권인규
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.64-71
    • /
    • 2012
  • 60 MPa급, 100 MPa급 고강도 철근콘크리트 기둥에 대하여 횡구속력 보강공법(와이어로프)과 내화보강공법(Fiber-Cocktail) 적용 유무 및 하중비에 따른 내화성능을 평가하기 위하여 표준화재 재하조건에 내화실험을 실시하였다. 실험결과 60 MPa급 고강도 콘크리트 기둥의 경우 와이어로프를 적용함으로써 화재시 축방향의 연성이 향상되며, 내화성능은 23 % 이상 향상되는 것으로 나타났다. 또한 와이어로프를 적용할 경우 하중은 설계하중의 70 % 수준이 적정하다고 판단된다. 100MPa급 고강도 콘크리트 기둥에 와이어로프와 Fiber-Cocktail을 적용할 경우 띠철근만을 적용한 경우보다 내화성능이 4배 이상 향상되는 것으로 나타났으며, 100MPa급 고강도 콘크리트 기둥에 내화성능을 확보하기 위해서는 하중은 설계하중의 70 % 미만으로 설정하는 것이 적정하다고 판단된다.