• Title/Summary/Keyword: Winter cooling storage

Search Result 23, Processing Time 0.023 seconds

Storage Characteristics of Rough Rice by Storage Method (저장방법에 따른 벼의 저장특성)

  • Lee, J.S.;Hong, H.K.;Kang, T.H.;Li, H.;Ham, T.M.;Kim, Y.H.;Han, C.S.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.3
    • /
    • pp.167-172
    • /
    • 2008
  • The objective of this study was to investigate the adequate storage method that was able to maintain the high quality of rough rice according to storage methods and period. The quality change of the rough rice during the storage period was evaluated by storage method such as cooling bin using winter cold air, ordinary temperature bin, freezing, refrigeration and indoor storage. Moisture content, brown rice whiteness, hardness, crack ratio and germination ratio were measured in this study. Moisture content of rough rice stored in cooling bin using winter cold air and ordinary temperature bin were decreased by 0.07% and 0.42%, respectively, which were lower than the other storage method. The hardness of brown rice increased in order of storage method such as winter cooling bin, normal bin, freezing storage, refrigeration storage and indoor storage. Crack ratio by indoor and ordinary temperature bin storage were increased by 2.68% and 3.63%, respectively, whereas cooling bin using winter cold air, refrigeration and freezing storage showed below 1.0%. The highest germination rate was found in cooling bin using winter cold air. As a result, cooling bin using winter cold air can be evaluated for the adequate storage method of rough rice.

Low Temperature Storage of Rough Rice Using Cold-Air in Winter (II) - Low Temperature Storage Characteristics of Rough Rice Using a Cooling System in the Top of a Bin - (겨울철 냉기를 이용한 벼의 저온저장 (II) - 빈상부 쿨링시스템을 이용한 냉각 벼의 저온저장 특성 -)

  • Lee, Jae-Seok;Hong, Hyun-Ki;Li, He;Park, Jong-Soo;Ham, Tack-Mo;Han, Chung-Su
    • Journal of Biosystems Engineering
    • /
    • v.32 no.1 s.120
    • /
    • pp.13-19
    • /
    • 2007
  • Storage rough rice in low temperature using the winter cold air avoids rough rice temperature increase which happens from early May, and this is possible by installing a cooling system in the top of a bin, the room between top rice level and bin ceiling. The research objective is to establish low temperature rough rice storage technique, furnishing winter cold air to rough rice, by investigating the cooling system potential of maintaining low rough rice temperature and by analyzing rough rice storage characteristics over a storage period. The rough rice storage characteristics were evaluated from January to August 2003, using a storage and dry bin of 400-ton capacity. Results of this research are as follows: Cooling bin using the cooling system in the top of the bin maintained the rice temperature less than 15$^{\circ}C$ in entire portions in August. Moisture contents and germination rates of rough rice were decreased over the storage period, on the other hand, the rough rice stored in the ambient temperature bin had relatively lower moisture contents and germination rates to compare with the bin using winter cold air. Crack ratio and acid value of brown rice in the ambient temperature bin storage had increased more than the cooling bin storage. The result indicates that the storage bin using winter cold air and the cooling system maintains moisture content and germination of rice, minimizes cracked kernel and acid value, and preserves rice quality as well.

Low Temperature Storage of Rough Rice Using Cold-Air in Winter(I) - Storage Characteristics after Rough Rice Cooling - (겨울철 냉기를 이용한 벼의 저온저장(I) - 벼 냉각 후 저장특성 -)

  • Lee J. S.;Han C. S.;Ham T. M.;Yon K. S.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.3 s.110
    • /
    • pp.155-160
    • /
    • 2005
  • The objective of this research was to establish a domestically available cooling storage technique by cold-air in winter, using winter cool air ventilation fur determining rough rice cooling method in the storage and dry bin. The rough rice storage characteristics of two test conditions, winter cool-air ventilation storage and ambient temperature storage, were evaluated from January to July 2001, using a storage and dry bin of 300-ton capacity. Results of this research are as follows: Grain temperature was from $-5.1\~-8.5^{\circ}C$ after winter cool-air ventilation, and grain initial temperature for ambient temperature bin storage was $0.3\~1.9^{\circ}C$. Moisture content of rough rice decreased from $0.28\;to\;0.93\%$ and from $1.53\;to\;1.92\%$ to compare with original moisture contents for winter cool-air ventilation, and for ambient temperature bin storage, respectively. Broken ratio of brown rice from winter cool-air ventilation bin increased from $0.16\;to\; 0.92\%$, and brown rice broken ratio was from $2.24\;to\;2.86\%$ for ambient temperature bin storage to compare with initial broken ratio. Hardness of stored rice increased along storage period increase in alt storage methods, and cooling bin storage increased rice hardness of 0.271kgf: this increasing was lower then the other methods from 0.059 to 2.239kgf. Germination rates were decreased approximately 9.03, 3.14 and $3.20\%$ for upper, middle, and bottom of ventilating winter air bin, respectively, and germination rates of 2.70, 3.47 and $4.14\%$ were approximately decreased for upper, middle, and bottom parts of ambient temperature bin storage, respectively.

Study on the Simulation of Heat Pump Heating and Cooling Systems to Hospital Building (병원 건물의 히트펌프 냉난방 시스템 적용을 위한 시뮬레이션 연구)

  • Choi, Young-Don;Han, Seong-Ho;Cho, Sung-Hwan;Kim, Du-Sung;Um, Chul-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.4
    • /
    • pp.275-282
    • /
    • 2008
  • In Korea, air source heat pump system is less efficient than conventional heat source facilities, because the air temperature in winter season is so low that COP of air source heat pump system drops below 3.0. Therefore, the study on the application of heat pump heating and cooling systems is crucial for the efficient popularization of heat pump. In this work, we present the dynamic analysis of energy consumption for the large hospital building by heat resistance-capacitance method. The system simulation of water storage air source heat pump is additionally performed by changing sizes and locations of the hospital building. The computed results show that energy cost of water storage air source heat pump is low, so it is more economical than absorption chiller & heater.

Study on the Performance of an ATES Geothermal Heat Pump System and Economic Analysis (ATES 열펌프 시스템 성능 및 경제성 분석에 관한 연구)

  • Oh, Myung-Suk;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.289-296
    • /
    • 2012
  • The aim of this study is to investigate the performance of a heating and cooling system with aquifer thermal energy storage(ATES heat pump system) known as one of the underground thermal energy storage application systems. The ATES system was composed of heat pump unit and ATES, which was installed in a factory building located in Anseoung. The system represented very high heating and cooling performance, and showed nearly constant COP at each heating and cooling season due to the stability of EWT. The economic analysis about an ATES system and a conventional system was also executed. The conventional system adopted an air-conditioner in the summer season and a LNG boiler in the winter season. The payback period of the ATES system was estimated by 6.62 years.

Storage Characteristics of Low Temperature Grain Warehouse using Ambient Cold Air in Winter

  • Ning, Xiao Feng;Li, He;Kang, Tae-Hwan;Han, Chung-Su
    • Journal of Biosystems Engineering
    • /
    • v.37 no.3
    • /
    • pp.184-191
    • /
    • 2012
  • Purpose: This study was conducted to investigate the storage and quality characteristics of brown rice under the low temperature warehouse conditions using ambient cold air in the winter. Methods: This new technique maintains rough rice warehouse temperature below $15^{\circ}C$ without cooling operation until the end of May. Four hundred tons of rough rice were stored in the low temperature grain warehouse, and were aerated from the top to the bottom using ambient cold air in February. The quality of rough rice was evaluated from February through October. Results: The results were as followings. Moisture contents of rough rice in the low temperature storage had decreased less than the ordinary temperature storage. Cracked rate of brown rice in the ordinary temperature storage and low temperature storage increased by 4~10.8% and 1.6~7.2%, respectively. The germination rate of rough rice under the ordinary and the low temperature warehouse decreased by 15.0~25.0% and 1.7~8.0%, respectively. The acid value of brown rice under the ordinary and the low temperature warehouse increased by 3.67~6.72 KOH mg/100g and 3.08~4.08 KOH mg/100g, respectively. Conclusions: The result indicates that low temperature storage using ambient winter air showed better maintaining germination of rice, less change of physiological activities and cracked kernel, and better maintaining of rice quality, comparing the ordinary temperature storage.

A Performance Analysis on a Chiller with Latent Thermal Storage According to Various Control Methods (잠열 축열식 칠러시스템의 제어 방식에 따른 성능 분석)

  • Kang, Byung Ha;Kim, Dong Jun;Lee, Choong Seop;Chang, Young Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.11
    • /
    • pp.592-604
    • /
    • 2017
  • A chiller, having a thermal storage system, can contribute to load-leveling and can reduce the cost of electricity by using electricity at night. In this study, the control experiments and simulations are conducted using both conventional and advanced methods for the building cooling system. Advanced approaches, such as the "region control method", divide the control region into five zones according to the size of the building load, and determines the cooling capacities of the chiller and thermal storage. On the other hand, the "dynamic programming method" obtains the optimal cooling capacities of the chiller and thermal storage by selecting the minimum-cost path by carrying out repetitive calculations. The "thermal storage priority method" shows an inferior chiller performance owing to the low-part load operation, whereas the chiller priority method leads to a high electric cost owing to the low utilization of thermal storage and electricity at night. It has been proven that the advanced control methods have advantages over the conventional methods in terms of electricity consumption, as well as cost-effectiveness. According to the simulation results during the winter season, the electric cost when using the dynamic programming method was 6.5% and 8.9% lower than that of the chiller priority and the thermal storage priority methods, respectively. It is therefore concluded that the cost of electricity utilizing the region control method is comparable to that of the dynamic programming method.

Study on the Simulation of Heat Pump Heating and Cooling Systems to Resident Building (숙박업소 건물의 히트펌프 냉난방 시스템 적용을 위한 시뮬레이션 연구)

  • Choi, Young-Don;Han, Seong-Ho;Cho, Sung-Hwan;Kim, Du-Sung;Um, Chul-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.1
    • /
    • pp.65-74
    • /
    • 2008
  • In Korea, air source heat pump system is less efficient than conventional heat source facilities, such as ground source, river water, because the air temperature in winter season is so low that COP of air source heat pump system drops below 3.0. Therefore, the study on the application of heat pump heating and cooling systems is crucial for the efficient popularization of heat pump. In this work, we present the dynamic analysis of energy consumption for the large resident building by heat resistance-capacitance method. The system simulation of water storage air source heat pump is additionally performed by changing of sizes and locations of the hospital building. The computed results show that energy cost of water storage air source heat pump is low, so it is more economical than absorption chiller & heater.

Thermal Storage Characteristics of Low Temperature Phase Change Materials for Thermal Environmental Control of Protected Cultivation System (시설 농업의 열환경조절을 위한 저온 상변화 물질의 축열 특성)

  • 송현갑;유영선;노정근;박종길
    • Journal of Bio-Environment Control
    • /
    • v.6 no.3
    • /
    • pp.216-224
    • /
    • 1997
  • In the recent 10 years the protected cultivation area in Korea has been increased rapidly, and now it is very important issue to develop the heating and cooling system using the renewable energy, because the greenhouse heating and cooling cost is increased with the fossil fuel price rises. Actually the development of the cooling system is more difficult than that of the heating system, since the cooling load of greenhouse in the summer season is 2―3 times larger than the heating load in the winter season. In this study low temperature phase change materials (LTPCM) for the cold storage system were selected and developed. The theoretical and experimental analysis of thermal characteristics of LTPCM makes it possible to control the phase change temperature and stabilize the thermo-physical properties. LTPCM developed in this study has good advantages to be used as the cold storage not only for the house and working space in factory but also for the cold storage of agricultural and live-stock products.

  • PDF