• 제목/요약/키워드: Windows and Doors System

검색결과 45건 처리시간 0.024초

주택시장에서 경쟁력을 갖기 위한 아파트 차별화 요소에 관한 연구 (A Study on the Differentiating Design Factors to Take the Lead in the Apartment Housing Market)

  • 하미경;박남희;이경희;정소원
    • 한국주거학회논문집
    • /
    • 제18권2호
    • /
    • pp.1-9
    • /
    • 2007
  • This survey on the housing consumers in the Daegu region aims to understand their needs for differentiating design items, which are now regarded to be essential factors to take the lead in the apartment housing market. The survey questionnaires on the differentiating items in six categories, were filled by 135 apartment households in Deagu, and the answers on each item were analyzed according to their home size and age. For the general apartment plan, the strongest need was found in the energy saving design; and larger windows for a fine view are significantly favored by the older households. For the unit design, more households were interested in the design items related to the kitchen or subsidiary-kitchens. For the storage space design, enough space for ampler storage was desired the most. For the interior design, prevailing needs for the use of environment-friendly furnishing materials and the non-slippery flooring of bathroom were found. For facilities and up-to-date system design, most of households displayed their interests in noise-proof doors. For the environment design of the complex, the need for a walk passage was highest in general.

공동주택 침기의 불확실성 분석 (Infiltration in Residential Buildings under Uncertainty)

  • 현세훈;박철수;문현준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.369-374
    • /
    • 2006
  • Quantification of infiltration rate is an important issue in HVAC system design. The infiltration in buildings depends on many uncertain parameters that vary with significant magnitude and hence, the results from standard deterministic simulation approach can be unreliable. The authors utilize uncertainty analysis In predicting the airflow rates. The paper presents relevant uncertain parameters such as meteorological data, building parameters (leakage areas of windows, doors, etc.), etc. Uncertainties of the aforementioned parameters are quantified based on available data from literature. Then, the Latin Hypercube Sampling (LHS) method was used for the uncertainty propagation. The LHS is one of the Monte Carlo simulation techniques that is suited for our needs. The CONTAMW was chosen to simulate infiltration phenomena in a residential apartment that is typical of residential buildings in Korea. It will be shown that the uncertainty propagating through this process is not negligible and may significantly influence the prediction of the airflow rates.

  • PDF

접합부 상세에 따른 복합 병렬 전단벽 시스템의 구조 성능 (Structural Performance of Hybrid Coupled Shear Wall System Considering Connection Details)

  • 박완신;윤현도;김선웅;장영일
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권3호
    • /
    • pp.128-137
    • /
    • 2012
  • 복합 병렬 전단벽(Coupled shear walls)은 커플링 보와 철근콘크리트 벽체로 구성되어 바람이나 지진 등의 횡하중으로부터 유발된 전도모멘트의 상당 부분을 철골 연결보의 커플링 작용에 의하여 골조 작용(Frame action)을 의하여 횡력에 효율적으로 저항하게 된다. 본 연구에서는 접합부 상세에 따른 복합병렬 전단벽의 접합부 강도에 대한 규준식을 정립하기 위한 선행연구로서 병렬 전단벽 접합부에서 커플링 보의 매립길이 및 벽체 두께를 주변수로 실험적 연구를 수행하여 접합부 상세에 따른 복합 병렬 전단벽 시스템의 거동특성을 규명하고자 하였다. 본 실험결과, 실험체의 거동 및 내력은 매립길이 및 접합부 상세에 많은 영향을 받는 것으로 나타났으며 향후 설계시 이에 대한 영향을 반영해야 할 것으로 판단된다.

방범하드웨어의 침입범죄 저항성능 시험·인증 체계에 관한 모형 연구 (Developing a Model for Crime Prevention Hardware Performance Test and Certification System)

  • 박현호
    • 시큐리티연구
    • /
    • 제36호
    • /
    • pp.255-292
    • /
    • 2013
  • 이 연구는 이미 오랫동안 제도적으로 시스템이 구축되어 가고 있는 외국에 비하여 시작단계에 있는 국내의 건축물 방범 관련 하드웨어 시험인증체계의 발전방향을 탐색하기 위해 시작되었다. 주요 목적은 주요 외국 사례를 심층 비교분석하고 국내의 유관 인증체계를 탐색하여 한국형 방범하드웨어 인증체계 모형을 도출하는 것이다. 연구방법은 방범하드웨어 인증제도에 대한 국내연구가 거의 전무하고 또한 방범하드웨어 인증제도에 관한 연구의 흐름이 이론적인 연구보다는 실무자들의 논의를 통한 법제적 논의나 사례연구가 대부분이라 주로 해외 선진국의 법제 및 사례를 통하여 한국형 방범하드웨어 인증제도 모색을 위한 시사점을 도출하는 탐색적 연구이다. 이를 위해 침입범죄 예방을 위한 해외의 방범하드웨어 인증제도와 국내의 유사 인증제도 사례에 대해 질적 연구방법 중에서도 대표적인 비교사례연구(comparative case study)를 실시하였다. 비교연구는 방법론적으로 명백하고 뚜렷한 개념 정의나 범위가 존재하지는 않지만, 장소 및 시간에 따른 비교가 가장 흔하게 활용되는 방법으로서 특히 이 연구에서는 복수사례설계(multiple case design)를 적용하였고 국가 간 그리고 제도 간 사례비교에서는 가능한 한 많은 체계에서 유사한 사례들을 비교분석하고 체계 간 차이점은 설명변수로 취급되는 최대유사체계설계를 반영하였다. 외국의 선진 방범제품 인증시스템과 국내의 소방/방화제품 인증시스템에 대한 이 비교연구 결과는 국내에서 방범제품 시험인증시스템 모형을 개발 및 구축하는데 여러 면에서 중요한 정보를 제공하고 시사점을 주고 있는데 근거 법규의 마련, 관련 시험 및 인증 표준 및 기준, 방범인증제품의 건축물 방범성능 인증과의 연계성, 공인시험기관을 통한 성능시험과 시험시설심사 또는 품질관리체계 심사 등 인증심사의 범위, 사후관리를 위한 주기적 인증갱신 또는 품질관리 및 검사, 인정 및 인증 체계, 시험원의 성격, 품질인증제품 사용에 대한 인센티브로서의 보험료 경감 또는 조달청 심사 가산점 부여 등이 주요 시사점이자 한국형 인증시스템 모형의 틀과 내용으로 도출되었다.

  • PDF

머름의 특성과 변천에 관한 연구 - 별당과 정자건축을 중심으로 - (A Study on the Characteristics and Periodical Changes of Meoreum - Focused on Byeoldang (Annexe) and Pavilion Architecture -)

  • 박일찬;이호열
    • 건축역사연구
    • /
    • 제20권2호
    • /
    • pp.7-22
    • /
    • 2011
  • This study primarily aims to illuminate the characteristics of $Meoreum$ in Korean traditional fitting system according to the respective types and its periodical changes. Using the research findings as a chronological indicator by which to estimate the construction date of the building is the secondary purpose. In this study 42 of $Byeoldang$ and pavilion architecture remaining in $Yeongnam$ district were examined through the field surveys and methods of documentary research. The research results are as follows. First, $Meoreum$, which is located below the windows or doors, provides protection against the outer wind and has the function to prevent some warm air of the room from flowing outside. Second, $Meoreum$ was recorded as $Yoeum$(了音), $Woneum$(遠音), and $Maleum$(末音) in $Yeong-geon-ui-gwe$(營建儀軌) of Joseon period. While $Yoeum$(了音) was used in $Yeong-geon-ui-gwe$(營建儀軌) of 1776 and 1856, $Woneum$(遠音) had been also used continuously since the year of 1800. The word, $Maleum$(末音) can be seen in $Lim-won-gyeong-je-ji$(林園經濟志), published in 1827. $Woneum$(遠音) and $Maleum$(末音) seem to be the $Yi-du$(吏讀) types of expression of $Meoreum$ which is being extensively used now. Third, the kinds of $Meoreum$ can be classified as $TohMeoreum$, $TongMeoreum$, $TongpanMeoreum$, and $JjaneunMeoreum$. $TongMeoreum$ and $TohMeoreum$ were mostly used at the front part of $Ondol-rooms$, the backside of main floor called $Daechung$(大廳), and at the space between $Daechung$ and rooms in the Pavilions and $Byeoldangs$(Annexes) that had been built in the early Joseon dynasty. $TohMeoreum$ was usually used at the bottom parts of windows between $Daechung$ and $Ondol-rooms$. $TongpanMeoreum$ was mainly used in the mid-Joseon period and relatively high height was the distinctive feature of $Meoreum$ at that time. $Jjaneun$ $Meoreum$, used mainly in the late Joseon dynasty, has become lower and lower gradually in height since 19th century, so people could enter the room through the windows(fittings). Such changes in $Meoreums$ types has brought about the flow of human traffic directly from $Toenmaru$, narrow wooden porch running along the outside of a room to $Ondol-rooms$.

기존 노후 건물의 단열 성능에 따른 옥상 녹화 시스템 설치시 에너지 성능 변화 (Energy Saving Effects of Green Roof in Exiting Buildings according to Different Insulation Levels)

  • 안경아;한승원;문현준
    • 한국생활환경학회지
    • /
    • 제21권6호
    • /
    • pp.959-964
    • /
    • 2014
  • Energy performance of building envelope components, including external walls, floors, roofs, windows and doors, is crutial for determining how much energy is required for heating and cooling in a building. Among various building technologies, a green roof system can be a good option for reducing heat gain and loss in new buildings as well as existing buildings for green remodeling. This paper evaluates the performance of green roof systems according to soil depth and Leaf Area Index (LAI) for existing buildings. It also attempts to quantify the energy saving effects on new and existing buildings with different insulation levels. Thermal performance of green roofs is mainly dependent on soil thickness and LAI. Installation of green roofs in deteriorated existing buildings can lead to improvements in roof insulation, due to the soil layer. An increase in soil depth leads to a decrease in heating load, regardless of conditions of vegetation on the green roof. Larger LAI values may reduce cooling loads in the cooling season. Installation of green roof in deteriorated existing buildings showed bigger energy saving effect in comparison to a case in new buildings. A simulation study showed that the installation of green roof systems in deteriorated existing buildings with low insulation levels, due to low thermal performance requirements when constructed, could improve the energy performance of the buildings similar or better to the peformance on new buildings with the most updated insulation standard. Thus, when remodeling a deteriorated building, green roofs could be a good option to meet the most recent energy requirements.

건축물 침입에 이용되는 침입수법 및 도구의 유형화 연구 (Study on the categorization of modus operandi and tools used in domestic burglary)

  • 박현호;조준택
    • 시큐리티연구
    • /
    • 제40호
    • /
    • pp.57-86
    • /
    • 2014
  • 본 연구는 건축물에 범죄예방설계가 도입되는 내용이 포함된 건축법 개정안이 통과됨에 따라 앞으로 활성화될 방범하드웨어 개선사업이 증거에 기반하여(evidence-based) 수행되기 위한 기초자료를 확보하기 위해 대상물 강화(target hardening)에 초점을 두고 침입범죄의 수법과 도구에 관한 조사를 실시하였다. 분석을 통해 침입수법에 대한 통계자료 구축방식의 개선, 침입수법에 대한 형사사법기관과 방범산업계, 관련 전문가들의 적극적인 공유 및 협력 강화, 지역주민 대상으로 침입수법에 대한 교육 등 범죄예방 안전교육 활성화와 같은 정책적 시사점을 도출하였다. 본 연구를 바탕으로 지역주민의 안전수준을 획기적으로 제고하기 위해서는 본 연구 결과에 기반하여 주요 침입구인 출입문, 창문, 창살 등 방범하드웨어의 침입저항 성능시험 연구, 성능에 대한 표준 및 인증체계에 관한 연구, 방범하드웨어의 개선과 범죄율과의 관계 관한 연구 등 다양한 후속연구가 활성화될 필요가 있다.

  • PDF

제천 스포츠센터 화재의 다수 사상자 발생원인 분석 -초기대응과 관리적인 측면을 중심으로- (Analysis of the Causes of Casualties of Jecheon Sports Center Fire - Focus on an Initial Response and Management -)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제32권5호
    • /
    • pp.57-66
    • /
    • 2018
  • 29명이 사망하고 40명이 부상을 입은 제천 스포츠센터 화재 사례에 대해 다수 사상자가 발생한 원인을 초기대응과 관리적인 측면을 중심으로 분석하였다. 초기대응 측면은 119신고 지연, 2층 세신사 비상구로 피난유도를 하지 않음, 1층과 3층 비상계단쪽 방화문 개방 상태 유지, 3층 주계단실 쪽 방화문 닫지 않음, 비상방송을 하지 않음으로 분석하였다. 관리적인 측면은 1층의 스프링클러설비 알람밸브 폐쇄, 소방펌프 제어반에서 기동 정지 위치에 놓음, 주차장 반자 안 누수 및 누전 방치, 2층 여탕의 휴게실 피난구유도등이 가려져 있고 비상구에 물건이 적치됨, 2층 자동문의 조작버튼 불량상태로 방치, 형식적인 소방안전관리, 소방시설 부실한 자체점검, 방화셔터와 배연창 미작동으로 분석하였다.

유리 파단면의 화재감식에 관한 실험적 연구 (An Experimental Study on the Fire Investigation to the Broken Plane Types of Glass)

  • 문용수;공하성
    • 대한안전경영과학회지
    • /
    • 제10권4호
    • /
    • pp.105-109
    • /
    • 2008
  • The purpose of this study is to distinguish the causes of broken glass on doors or windows when it is originally kept among the remains on the floor in fire site - whether it was broken due to heating or outer power-through test and characteristics of the broken plane including the pattern on the plane. Addition to it, the study tries to find characteristics to judge the point and direction of breakdown through the analysis of glass broken by outer power. With two assumed causes - a) breakdown due to heating and b) breakdown due to outer power-3 pieces of glass plates ($30cm{\times}30cm{\times}5mm$) were tested for each case, getting the results as following: First, for the glass broken due to the change of temperature, the broken plane is of slow and smooth curve without any pattern. Second, for the glass broken due to outer power, with the impact point as the center, the glass shows breakdown of radial type and the side shows breakdown of near-perpendicular type. The far the broken piece is from the impact point, the bigger the size is. The broken piece at the impact point is of long triangle type and the two long planes of the triangle shows semi-arc with the center of breakdown point and the other plane shows opposite pattern. Third, when glass that is damaged by outer power is heated, damaged forms and side patterns of the glass that is damaged by outer power are heated and disappeared.

Floor Plan Analysis of Detached Houses for the Low-income Households

  • Kim, Junghwa;Ahn, Byunglip;Jang, Cheolyong;Jeong, Hakgeun;Kim, Jonghun
    • KIEAE Journal
    • /
    • 제14권3호
    • /
    • pp.39-45
    • /
    • 2014
  • Energy poverty has been defined as low-income households who paid energy cost more than 10% of their ordinary income. Therefore, there are various subsidy programs focused on house remodeling for low-income households and one of them is the Home Energy Efficiency Assistance Program which have done by Korea Energy Foundation since 2007. The aim of the program is to improve the thermal performance of dilapidated dwellings and analyzed the detached house for the low-income households to develop the building typology. The database contained approximately 3,061 households which was obtained from the program in 2013 and the results of the study were like this; 1) For the shape of residential houses, the number of rectangular shaped building was higher than non-rectangular shaped ones. 2) For the orientation of buildings, the south layout of the detached housing was dominant to gain heating energy into buildings. 3) For the floor area, the average floor area was $44.2m^2$, although its size varied wide variations, which range from $6.3m^2$ to $107.1m^2$. 4) For the windows and doors, the south-facing window was larger than the other side. Finally it would be possible to determine the characteristics of residential houses for low-income families. A future study could establish typology of low-income housing that it would estimate the performance of each model building before and after the retrofit to improve the energy performance.