• Title/Summary/Keyword: Window glass breakage

Search Result 7, Processing Time 0.017 seconds

A Experimental Study on Window Glass Breakage in Compartment Fires (구획 화재시 창유리 파괴 현상에 관한 실험적 연구)

  • 이수경;김종훈;최종운;이정훈
    • Fire Science and Engineering
    • /
    • v.12 no.3
    • /
    • pp.21-30
    • /
    • 1998
  • This is a study on the relation of window glass breaking time, shape, and vent condition in a compartment fire through the experiment. We recognize the phenomenon that window glass breakage in a compartment fire be arose from the thermal stresses due to the temperature temperature difference was 233.4$^{\circ}C$ for test 1-3, 138$^{\circ}C$ for text 2-1, 83.6$^{\circ}C$ for test 2-2. The interior test 2-2, 400.9$^{\circ}C$ for test 2-3. so if the flame didn't reach at the surface of window glass, the breakage of glass occure at 40$0^{\circ}C$~50$0^{\circ}C$. when the fire size reached to 1541.14kW, the window might be broken by thermal stress. But window glass was not collapsed.

  • PDF

A Comparative Experiment on Thermal Stress Failure of Vacuum Glazing applied in Curtain Wall at Spandrel area (커튼월 스팬드럴용 진공유리의 열파손에 대한 비교실험)

  • Kim, Seung-Chul;Yoon, Jong-Ho;Shin, U-Cheol;Ahn, Jung-Hyuk
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.121-128
    • /
    • 2016
  • Purpose: The vacuum glazing should constantly retain the gap in vacuum state to maintain high thermal performance. To do so, pillars are used to prevent the glazing from clinging to each other by the atmospheric pressure and therefore surface of the vacuum glazing is consistently affected by residual stress. The vacuum glazing could be applied to curtain wall systems at spandrel area to fulfill a rigorous domestic standard on U-value of the external wall. However, this can lead to high glazing temperature increase by heat concentration at a back panel and finally thermal stress breakage. This study experimentally determined weakness of the vacuum glazing systems on the thermal stress breakage and investigated effect of the residual stress. Method: The experiment first built two scale-down mock-up facilities that replicate the spandrel area in curtain wall, and then installed single low-e glass and vacuum glazing respectively. The two mock-up facilities were exposed to outside to induce the thermal stress breakage. Result: The experiment showed that the temperature occurred the thermal stress breakage was $114.4^{\circ}C$ for the single low-e glass and $118.9^{\circ}C$ for the vacuum glazing respectively. The result also showed the vacuum glazing reached the critical point earlier than the single low-e glass, which means that the vacuum glazing has high potential to occur the thermal shock breakage. In addition, the small temperature difference between two glazing indicates that the residual stress scarcely affects breakage of the vacuum glazing.

A study on the strengthening of Sodalime glass using ion exchange method (이온강화법을 이용한 소다라임 글라스 강화에 관한 연구)

  • Ahn, H.W.;Oh, J.H.;Kweon, S.G.;Choi, S.D.
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.145-151
    • /
    • 2014
  • The glass used for mobile display windows is required to have high strength. Chemical strengthening by means of ion exchange is widely used glass. The depth of the layer and the compressed stress are affected by tempering temperature and time. The purpose of this study is to investigate the range of DOL and CS, which to less breakage during reliability tests such as the ball drop test, hole drop test, 3-point bending test, drop test, and tumble test with Soda-lime Glass.

Experimental Study on Interaction of Water Sprayed Curtain on Hot Surface of a Window Glass and its Effects on Glass Surface Temperature in Room Fires (구획화재 시 국부복사열에 노출된 유리면의 수막접촉에 따른 급냉파열특성 관한 실험적 연구)

  • 박형주;지남용
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.124-130
    • /
    • 2003
  • This research focuses on analysis of a interaction fracture of various glasses due to contact of water sprayed curtain on hot glass surface with high temperature produced from convective heat source near glass wall. A large scaled experimental test was done in order to find the range of the glass surface temperature to be able to cause the breakage of the glasses when water droplets reach on the hot surface. This paper shows the allowable temperature of the glass surface for prevention of the cooling down breakage before water curtain droplets contact the surface. Allowable Temperature if $250^{\circ}C$ for the tempered glass but general glass is very relatively low. Therefore if the water curtain spray system was adequately activated by a thermal detector installed below ceiling adjacent glass wall with water curtain nozzle system, all hot glass would not break out by cooling water droplet's contact on the hot surface due to convective heat released by adjacent fire source near the glass wall.

Comparative Analysis between a Real-Life Explosion Case and A Damage Prediction Program (J도 LPG충전소 가스 누출로 인한 폭발사례와 피해예측 프로그램의 비교 분석)

  • Yongho Yang;Soonju Kim;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.3
    • /
    • pp.59-70
    • /
    • 2024
  • This study aims to estimate the scope of damage impact with a real-life explosion case and a damage prediction program (ALOHA) and suggest measures to reduce risk by comparing and analyzing the results using a Probit model. After applying it to the ALOHA program, the toxicity, overpressure, and radiant heat damage of 5 tons of storage scopes between 66 to 413 meters, and the real-life case also demonstrated that most of the damage took place within 300 meters of the LPG gas station. In the Probit analysis, the damages due to radiant heat were estimated as first-degree burns (13-50%), while structural damage (0-75%) and glass window breakage (94-100%) were expected from overpressure, depending on the storage volume. After comparing the real-life case and the damage prediction program, this study concluded that the ALOHA program could be used as the scope of damage impacts is nearly the same as the actual case; it also concluded that the analysis using the Probit model could reduce risks by applying calculated results and predicting the probability of human casualties and structural damages.

A Study on the Fire Spread between Office Room and Atrium in the Atrium Building (아트륨 빌딩에서의 사무실과 아트륨간의 화재확산에 관한 연구)

  • Lee, Su-Kyung;Kim, Jong-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.2
    • /
    • pp.78-83
    • /
    • 2000
  • Generally, There is to install fire resist shutter or to compart between the office room and the atrium in the atrium buildings in Korea. But, Glass wall that is installed sprinkler which purpose to protect it from fire, is already installed between the office room and the atrium in the advanced nations. We study this problem as follow; We made the fire scenario, and analyze each scenario using FASTLite is fire modeling software and BREAK1 is to predict the window breakage time in the compartment fire. In this study, we can decide that fire compartmentalization between atrium and office rooms doesn't require in Atrium building if the material and fire protection system were reliable. Consequently, Korean Fire Protection Regulations have to consider in direction of increasing freedom of building.

  • PDF