• 제목/요약/키워드: Window Glazing

검색결과 72건 처리시간 0.027초

저방사 코팅이 진공창의 열성능에 미치는 영향 (Study on thermal performance of vacuum window with various low-ε coating glasses)

  • 조성환;태춘섭
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.300-311
    • /
    • 1997
  • A theoretical method was developed to analyze the effect of low-$\varepsilon$ coatings which have influence on thermal performance of vacuum windwo glazing and double pane glazing. The overall heat transfer coefficient(U) value and thermal performance were analyzed by theroretical method on various kins of windows. TRNSYS program was used to analyze total heating and cooling energy consumption on the model building which has various windows. As the result, better thermal insulation can be achieved on the vacuum window glazing than double pane glazing when low-$\varepsilon$ coating was done on the surface of glass. Total heating and cooling energy consumption was almost same on the double pane window glazing but was lessened on the vacuum window glazing when the window size of south direction increased. Therefore, low-$\varepsilon$ coating was very necessary for vacuum window glazing in order to improve thermal insulation performance and efficient energy conservation can be achieved by vacuum window glazing at the real building which has large window.

  • PDF

덧유리 및 방풍재 적용을 통한 슬라이딩 창의 단열 및 기밀성능 개선효과 분석 (The Effect of the Attached Glazing and Windbreak on the Thermal Performance and Air Tightness of Sliding window)

  • 배민정;강재식;최경석;최현중
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.59-65
    • /
    • 2017
  • Purpose: Thermal performance and air tightness of window are improved for the building energy efficiency. As the deteriorated houses are increased, the improve measures with low cost and easy installation are developed in the energy performance of window. Attached glazing and windbreak can be easily applied to the window with low cost. In this paper, the effect of the attached glazing and windbreak on the thermal performance and air tightness of window is analyzed as the measure to improve performance of window. Method: Thermal transmittance of glazing is evaluated through WINDOW simulation according to thickness of attached glazing and air cavity. Based on the simulation results, thermal transmittance, air tightness and condensation resistance performance of four cases are tested according to Korea standards. One type of PVC sliding double window is chosen as the specimen. For the analysis on low performance of window, the outside of window is excluded in the PVC sliding double window. Result: This study shows that thermal performance of glazing can be increased by the application of attached glazing. Furthermore, lower thermal performance of glazing can obtain the higher effect of attached glazing. The application of attached glazing and windbreak can effect on increasing thermal performance and air tightness of window.

창호를 통한 열전달 현상에 관한 연구 (A Study on the Heat Transfer Phenomenon through the Glazing System)

  • 강은율;오명원;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.32-37
    • /
    • 2009
  • An energy loss through the window system occupies about 10 to 30 percent on energy consumption of the whole building. That is the reason, several elements for a building composition of window system are the weakest from the heat. Insulation performance increases for the reducing heat loss. Heat transfer through the window system that is reducing heat transfer through conduction, convection and radiation. Insulation performance reinforcement methods classify improving heat specific quality of window system and improving efficiency of whole window system. The most application method among each methods is reducing emission ratio of the window system(Low-E glass), increasing a number of glazing(multiple window) and a method of vacuuming between glazing and glazing. Therefore this study is investigated a sort of glazing and specific character, U-value calculation with changing glazing thickness and calculation of temperature distribution and U-value with a glazing charging gas kind from double glazing. For a conclusion, an aspect of U-value figure at the smallest value case of vacuum glazing with Low-E coating. That means insulation efficiency is the best advantage during a building plan selecting vacuum glazing with Low-E coating for a energy saving aspect. In this way, U-value become different the number of glazing, coating whether or not and selecting injection gas. Therefore selecting of glazing is very important after due consideration by a characteristic and use of building and consideration of strong point and weak point.

  • PDF

Glazing 특성에 따른 고층 오피스 건물의 에너지성능 분석 (The Analysis on Energy Performance according to Characteristics of Glazing in High-rise Office Buildings)

  • 황우진;김교준;최원기
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.156-161
    • /
    • 2011
  • In case of newly constructed buildings, the construction type is almost Curtain-wall system or large window in building skin. However, these kind of buildings have problems with regulations on building energy efficiency. And national regulations on building energy efficiency limit only the V-factor of window(except infiltration), it is hard to predict energy consumption of Curtain-wall buildings which gain large solar energy in summer. In this study, the influence of LSG(Light to Solar Gain) on energy performance was theoretically analyzed with simulation. LSG is the value of VLT divide SHGC and represents the optical performance of the glass or glazing. The Window & Therm program developed in LBNL was used to analyze window systems and EnergyPlus was used to building energy. Cases of glazing are three types; single coated Low-e clear glazing, tripple coated Low-e clear glazing, tripple coated Low-e tinted glazing. The results of this study are follows; 1) The building energy consumption of Alt-l, 2, 3 were about 300, 253, $259kWh/m^2{\cdot}yr$ respectively. Therefore, improvement of LSG could save the energy up to 16%. 2) The saved energy could be converted 1 billion won as annual benefit of total energy costs 3) SHGC and LSG more influence on cooling energy than heating energy in office buildings.

  • PDF

공기 중 폭발하중에 대한 창호시스템의 방폭설계 절차에 관한 고찰 (A Review on the Blast Resistant Design for Glazing and Window Systems Subject to High-explosive Loadings)

  • 허영철;정태영;오성근
    • 한국소음진동공학회논문집
    • /
    • 제20권12호
    • /
    • pp.1229-1235
    • /
    • 2010
  • Anti-terrorism design for public buildings as well as military facilities is important to minimize the mass casualties from terrorist attacks. Also, well designed glazing and window systems can reduce the potential injury of human caused by scattering fragment of a glazing. In this paper, blast resistant design for glazing and window systems is investigated based on the U.S. Standard. The design procedures include minimum requirements for the design, standard practice for design evaluation of the glazing and standard test method for evaluation of the performance.

단열성 시험 방법을 통한 진공유리의 구성 및 필러 배치에 따른 열 성능 평가 (The Evaluation of Thermal Performance of Vacuum Glazing by Composition and the Pillar Arrangement through Test Method of Thermal Resistance)

  • 조수;김석현;엄재용
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.61-68
    • /
    • 2015
  • The advanced counties effort to the supplement of the zero energy buildings for the global building energy saving. In the middle of the development of passive technology, the government has to effort to the energy saving of buildings by enhanced performance of the window thermal insulation. By the method of enhanced performance of window thermal insulation, the use of vacuum double glazing saves the energy consumption in building. This glazing has low U-value(heat transmission coefficient) than normal double glazing. The vacuum glazing enhanced thermal insulation performance by vacuum space of between the glass and glass. For this vacuum glazing, pillar maintain the space between glass and glass. But this structure cause the raising the heat transmission coefficient in pillar approaching glass. This study confirmed the U-value by the test method of thermal resistance for windows and doors. Also this study confirmed the variation of heat transmission coefficient by the structure of vacuum glazing. And this study measured the surface temperature of the vacuum glazing about pillar approaching glass and vacuum space in cool chamber and hot box. That result, this study confirmed U-value of $0.422W/m^2{\cdot}K$ of vacuum glazing. Also this study confirmed U-value of $0.300{\sim}0.422W/m^2{\cdot}K$ by various the structure of vacuum glazing. And this study confirmed the heat flow in pillar approaching glass.

로이유리 발코니 창호의 단열성능에 따른 공동주택 건축물 에너지효율등급 평가 연구 (A Study on Evaluation of the Building Energy Rating depending on the Thermal Performance of Balcony Window with Low-E glazing)

  • 이나은;안병립;장철용;이승복
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.58-63
    • /
    • 2012
  • As the exterior of building has been considered one of th important parts, the use of glass that is suitable to express various appearances gets raised. However, windows have 6~7times lower insulating performance than insulated walls. Lately, highly efficient windows are required as the needs for reduction of energy consumption come to the force. Therefore, Nowadays more people use cooling systems in summer, more the use of Low-E glazing is increasing. Because it is good to block Solar Radiant Energy which can cause much of heat loss while cooling system is working. This study measures U-value of the double Low-E glazing window and commonly used single Low-E glazing window. And then the effect of each window on the efficiency rating has been analyzed applying to the certification system of the building energy efficiency rating which has implemented.

시뮬레이션과 실증실험을 통한 슈퍼윈도우의 성능분석 (Analysis Performance of Super Window through Simulation and Verification Experiment)

  • 백상훈;이진성;조수;장철용;성욱주;서승직
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1069-1074
    • /
    • 2006
  • Heat loss by window in building occupies about 1/4 of energy amount used building. Therefore, high thermal insulation of windows system can speak as very important part in save energy of building. in this research, After select most suitable frame design and Glazing system for high thermal insulation of windows, execute simulation of mixing frame and Glazing System. Also, manufacture windows with the result and execute verification experiment, with verified simulation, this research evaluated thermal insulation performance of window by Glazing System's change.

  • PDF

축소모형을 이용한 분할형 유리 투과체 창호시스템의 채광성능실험 (Scale Model Experiment on Daylighting of Differentiated Glazing System)

  • 정인영;김정태
    • KIEAE Journal
    • /
    • 제4권4호
    • /
    • pp.61-68
    • /
    • 2004
  • Daylight is a critical factor in architecture, as it helps enhance the working efficiency and pleasantness of the people working inside, in addition to reduce the power consumption in heating and cooling and make the interior space brighter. There are many kinds of glazing and daylighting systems. At present, research and efforts for their development are carried out, alongside quantitative evaluation. This study aims to present basic materials to be used to design proper glazing and daylighting systems in architecture based on a quantitative evaluation by scale models of existing office buildings. The result of the study can be summarized as follows. 1)As a result of the experiment, it appeared that the ratio of the interior illumination (i.e. at the working table, ceiling and wall) against the outdoor illumination increases at a constant rate, as the transmittance of the glazing goes up. 2) It was found that the SIR(Sunlight Illuminance Ratio) of a separated window system goes up by 20-50% at the rear part than in the case of an ordinary window system.

국내 친환경 아파트의 채광창 면적비에 관한 연구 (A Study on Glazing Ratio of Certified Green Building Apartment)

  • 김상범;박종훈;양병이
    • KIEAE Journal
    • /
    • 제10권5호
    • /
    • pp.95-100
    • /
    • 2010
  • Buildings receive solar radiation through windows and the solar radiation helps to save heating energy in winter. Therefore the bigger the glazing ratio is, the larger the amount of solar radiation we can receive. In this study we analysed the glazing ratio of Certified Green Building Apartments. And we verified whether the glazing ratio reflects energy saving through accepting solar radiation with correlation analysis. For glazing ratio analysis, we selected 116 apartment buildings of 19 apartment complexes that certified in 2008-2009 and took pictures of outside windows of the buildings. After that, we analysed the building's glazing ratio with 4 azimuth and checked distinction of the glazing ratio between 6 coupled azimuths. And we analysed the correlation between importance order of azimuth for energy saving and the glazing ratio change with the azimuth. The analysis showed that the glazing ratio does not reflect energy saving through accepting solar radiation.