• Title/Summary/Keyword: Window 95

Search Result 132, Processing Time 0.023 seconds

A Study on BASINS/WinHSPF for Evaluation of Non-point Source Reduction Efficiency in the Upstream of Nam-Han River Watershed (BASINS/WinHSPF를 이용한 남한강 상류 유역의 비점오염원 저감효율평가)

  • Yoon, Chun-Gyeong;Shin, Ah-Hyun;Jung, Kwang-Wook;Jang, Jae-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.951-960
    • /
    • 2007
  • Window interface to Hydrological Simulation Program-FORTRAN (WinHSPF) developed by the United States Environmental Protection Agency (EPA) was applied to the upstream of Nam-Han river watershed to examine its applicability for loading estimates in watershed scale and to evaluate non-point source control scenarios using BMPRAC in WinHSPF. The WinHSPF model was calibrated and verified for water flow using Ministry of Construction and Transportation (MOCT, 3 stations, 2003~2005) and water qualities using Ministry of Environment (MOE, 5 station, 2000~2006). Water flow and water quality simulation results were also satisfactory over the total simulation period. But outliers were occurred in the time series data of TN and TP at some regions and periods. Therefore, it required more profit calibration process for more various parameters. As a result, all the study was performed within the expectation considering the complexity of the watershed, pollutant sources and land uses intermixed in the watershed. The estimated pollutant load for annual average about $BOD_5$, T-N and T-P respectively. Nonpoint source loading had a great portion of total pollutant loading, about 86.5~95.2%. In WinHSPF, BMPRAC was applied to evaluate non-point source control scenarios (constructed wetland, wet detention ponds and infiltration basins). All the scenarios showed efficiency of non-point source removal. Overall, the HSPF model is adequate for simulating watersheds characteristics, and its application is recommended for watershed management and evaluation of best management practices.

Water Quality Management using WASPS & WASP Builder for a Basin of an Agricultural Reservoir (WASP5 & WASP Builder을 이용한 농업용저수지 유역의 수질관리)

  • Chung, Paul-Gene;Goh, Hong-Seok;Hyun, Mi-Hee;Lee, Eun-Ju
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.422-431
    • /
    • 2004
  • Water quality modeling was performed for the purpose of diagnosis and prediction of water quality in Gyoung Choen reservoir, using EUTR05/WASP Build model. WASP Builder is capable of visual display in window and it has an advantage of updating and modification for data. Field data of 1992, Spring, Summer, and Fall, were used to calibrate model and these results were validated using data of 2000, Spring, Summer, and Fall. The reservoir was divided into 4 epilimnion segments. Water quality system for modeling were consist of BOD, Chlorophyll-a, DO, $NH_3-N$, $NO_3-N$, T-N, $PO_4-P$, T-P. The results of water quality modelling using EUTR05/WASP Builder, a range of the Correlation for calibration of BOD, T-N, T-P, and Chlorophyll-a according to three seasons are 0.63~0.90, 0.81~0.97, 0.75~0.98, and 0.77~0.98 respectively. And the correlation between simulated and observed values for verification of BOD, T-N, T-P, and Chlorophyll-a according to three seasons are 0.93, 0.94, 0.81, and 0.80 respectively. Among the pollutant sources for a basin of the Gyoung Choen reservoir, generated amount of livestock is the highest and BOD, T-N, T-P of generated loading percentage are 94%, 81%, and 95%. So, we suppose that inflow load amount will decrease 50% and increase 50% only livestock about current load amount. If increasing load amount of livestock 50% in segment 2 and 3, BOD, T-N, and T-P simulated increasing to range of $0.02~0.15mg/{\ell}$, $0.029~0.08mg/{\ell}$, $0.011~0.029mg/{\ell}$ in comparison with current water quality

The Use of FDG PET for Nodal Staging of Non-Small-Cell Lung Cancer (비소세포폐암 환자의 국소 림프절 전이 발견을 위한 FDG PET의 이용)

  • 백희종;박종호;최창운;임상무;최두환;조경자;원경준;조재일
    • Journal of Chest Surgery
    • /
    • v.32 no.10
    • /
    • pp.910-915
    • /
    • 1999
  • Background: Positron emission tomography(PEFT) using fluorine-18 deoxyglucose(FDG), showing increased FDG uptake and retention in malignant cells, has been proven to be useful in differentiating malignant from benign tissues. We indertook the prospective study to compare the accuracy of the whole-body FDG PET with that of the conventional chest computed tomography(CT) for nodal staging of non-small-cell lung cancers(NSCLC). Material and Method: FDG PET and contrast enhanced CT were performed in 36 patients with potentially resectable NSCLC. Each Imaging study was evaluated independently, and nodal stations were localized according to the AJCC regional lymph nodes mapping system. Extensive lymph node dissection(1101 nodes) of ipsi- and contralateral mediastinal nodal stations was performed at thoracotomy and/or mediastinoscopy. Image findings were compared with the histopathologic staging results and were analyzed with the McNema test(p) and Kappa value(k). Result: The sensitivity, specificity, positive predictive value, and negative predictive value of CT for ipsilateral mediastinal nodal staging were 38%, 68%, 25%, 79%, and 61%, and those of PET were 88%, 71%, 47%, 95%, and 75%(p>0.05, K=0.29). When analyzed by individual nodal group(superior, aortopulmonary window, and inferior), the sensitivity, specificity, positive predictive value, and negative predictive value of CT were 27%, 82%, 22%, 85%, and 73%, and those of PET were 60%, 87%, 92%, and 82%(p<0.05, k=0.27). Conclusion: FDG PET in addition to CT appears to be superior to CT alone for mediastinal staging of non-small cell lung cancers.

  • PDF

Simulation of Characteristics of Lens and Light Pipe for High Concentration Solar PV System (고집광 태양광 발전을 위한 렌즈 및 광 파이프 특성 시뮬레이션)

  • Ryu, Kwnag-Sun;Shin, Goo-Hwan;Cha, Won-Ho;Myung, Noh-Hoon;Kim, Young-Sik;Chung, Ho-Yoon;Kim, Dong-Kyun;Kang, Gi-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.282-286
    • /
    • 2011
  • The artificial increase in the solar intensity incident on solar cells using lenses or mirrors can allow solar cells to generate equivalent power with a lower cost. In application areas of Fresnel lenses as solar concentrators, several variations of design were devised and tested. Some PV systems still use commercially available flat Fresnel lenses as concentrators. In this study, we designed and optimized flat Fresnel lens and the 'light pipe' to develop 500X concentrated solar PV system. We performed rigorous ray tracing simulation of the flat Fresnel lens and light-pipe. The light-pipe can play imporatant roles of redistributing solar energy at the solar cell and increase the mechanical tolerance so that it can increase the lifetime of the high-concentration solar PV system and decrease the cost of manufacturing. To investigate the sensitivity of the solar power generated by the concentrated solar PV according to the performance of lens and light pipe, we performed raytracing and executed a simulation of electrical performance of the solar cell when it is exposed to the non-uniform illumination. We could conclude that we can generate 95 % or more energy compared with the energy that can be generated by perfectly uniform illumination once the total energy is given the same.

  • PDF

Design and Preliminary Performance Test for 5kWt Dish Solar Collector ($5kW_t$급 접시형 태양열 집열기의 설계 및 예비 성능실험)

  • Seo, Joo-Hyun;Ma, Dae-Sung;Kim, Yong;Seo, Tae-Beom;Han, Gui-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.113-120
    • /
    • 2007
  • The 5kWt dish solar collector is designed and the preliminary performance test for this is carried out. The diameter of the parabolic dish is 3.2 m, and its focal length is 2 m. It consists of 10 small reflectors which have their own curvatures, and the effective reflecting area is $5.9\;m^2$, and the rim angle of the dish is $43.85^{\circ}$. The reflectivity of reflectors is 0.95, and the thermal capacity of the system is about 5 kW thermal. The aperture diameter of the cylindrical-shape receiver which is made of stainless steel is 100 mm, and the height is 210 mm. A quartz window is installed at the receiver aperture to minimize the convective heat loss and prevent air leakage. In order to increase the heat transfer area, porous materials (nickel-alloy) are inserted into the receiver. Air flows into the upper part of the receiver which is the opposite side of the aperture. After the air flows through the inside of the receiver, that goes out of the receiver through 3 exits which are located near the aperture. The volumetric flow rates of air are varied from 600 to 1200 L/min. The results show that the system efficiency and receiver efficiency increase as the volume flow rate increases.

A Basic Study on the Exhibition Evaluation and Improvement in Science Museum - Focused on the exhibitions of the National Science Museum in Korea - (과학관의 전시평가와 개선방안에 관한 기초연구 - 국립중앙과학관의 상설전시관을 중심으로 -)

  • Hwang Eun-Kyung;Hong Su-Mi;Lim Che-Zinn
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.4 s.51
    • /
    • pp.95-105
    • /
    • 2005
  • To plan more effective exhibitions, exhibitions should be evaluated and verified through research. This is Important in that it will present measures for improving shortcomings in exhibition goals and procedures; and it will also provide new ideas and goals for future exhibition plans. The purposes of this study are to investigate the applicability of evaluation methods by organizing related theories systematically through a literature review and to provide more practical and valuable information about the methods by applying them to actual museums. For this study, the National Science Museum was investigated since it uses various themes and exhibition methods, compared with other science museums. Exhibition structures and presentation formats were first analyzed, and then the methods of trace and observation were used to investigate how visitors use the museum. Surveys were also conducted at two different times. The results of the analyses showed that problems of exhibits, arrangement methods of exhibition space, or guide systems are more prominent than those of the presentation format itself. Based on these results, measures for improvement are suggested as follows: First, new formats of exhibition halls using new window frames or holes should be explored to stimulate visitors' curiosity and to lead viewing traffic flow in the museum. Second, in presenting representative exhibits, a gate can be installed at each exhibition area, and representative exhibits are displayed by the gate or between exhibition booths. Third, if a small space is provided at the end of each exhibition area, it can be used to give an orientation on the next exhibition or used as a resting place.

Color and hardness changes in artificial white spot lesions after resin infiltration (레진 침투법 후 인공 법랑질 백색 병소의 색과 경도 변화 비교)

  • Kim, Ji-Hoon;Son, Ho-Hyun;Chang, Ju-Hea
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.2
    • /
    • pp.90-95
    • /
    • 2012
  • Objectives: The purpose of this study was to determine the effect of resin infiltration technique on color and surface hardness of white spot lesion (WSL) with various degrees of demineralization. Materials and Methods: Ten human upper premolars were cut and divided into quarters with a $3{\times}4mm$ window on the enamel surface. Each specimens were separated into four groups (n = 10) and immersed in demineralization solution to create WSL: control, no treatment (baseline); 12 h, 12 hr demineralization; 24 h, 24 hr demineralization; 48 h, 48 hr demineralization. Resin infiltration was performed to the specimens using Icon (DMG). $CIEL^*a^*b^*$ color parameters of the enamel-dentin complex were determined using a spectroradiometer at baseline, after caries formation and after resin infiltration. Surface hardness was measured by Vickers Micro Hardness Tester (Shimadzu, HMV-2). The differences in color and hardness among the groups were analyzed with ANOVA followed by Tukey test. Results: Resin infiltration induced color changes and increased the hardness of demineralized enamel. After resin infiltration, there was no difference in color change (${\Delta}E^*$) or microhardness among the groups (p < 0.05). Conclusion: There was no difference in the effect of resin infiltration on color and hardness among groups with different extents of demineralization.

COVID-19 vaccine-induced immune thrombotic thrombocytopenia: a review

  • Siti Nur Atikah Aishah Suhaimi;Izzati Abdul Halim Zaki;Zakiah Mohd Noordin;Nur Sabiha Md Hussin;Long Chiau Ming;Hanis Hanum Zulkifly
    • Clinical and Experimental Vaccine Research
    • /
    • v.12 no.4
    • /
    • pp.265-290
    • /
    • 2023
  • Rare but serious thrombotic incidents in relation to thrombocytopenia, termed vaccine-induced immune thrombotic thrombocytopenia (VITT), have been observed since the vaccine rollout, particularly among replication-defective adenoviral vector-based severe acute respiratory syndrome coronavirus 2 vaccine recipients. Herein, we comprehensively reviewed and summarized reported studies of VITT following the coronavirus disease 2019 (COVID-19) vaccination to determine its prevalence, clinical characteristics, as well as its management. A literature search up to October 1, 2021 using PubMed and SCOPUS identified a combined total of 720 articles. Following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guideline, after screening the titles and abstracts based on the eligibility criteria, the remaining 47 full-text articles were assessed for eligibility and 29 studies were included. Findings revealed that VITT cases are strongly related to viral vector-based vaccines, which are the AstraZeneca COVID-19 vaccine (95%) and the Janssen COVID-19 vaccine (4%), with much rarer reports involving messenger RNA-based vaccines such as the Moderna COVID-19 vaccine (0.2%) and the Pfizer COVID-19 vaccine (0.2%). The most severe manifestation of VITT is cerebral venous sinus thrombosis with 317 cases (70.4%) and the earliest primary symptom in the majority of cases is headache. Intravenous immunoglobulin and non-heparin anticoagulant are the main therapeutic options for managing immune responses and thrombosis, respectively. As there is emerging knowledge on and refinement of the published guidelines regarding VITT, this review may assist the medical communities in early VITT recognition, understanding the clinical presentations, diagnostic criteria as well as its management, offering a window of opportunity to VITT patients. Further larger sample size trials could further elucidate the link and safety profile.

A study on the thermochromism of $V_{1-x}M_xO_2$thin film ($V_{1-x}M_xO_2$박막의 thermochromism에 대한 연구)

  • Lee, Si-U;Lee, Mun-Hui
    • Korean Journal of Materials Research
    • /
    • v.4 no.6
    • /
    • pp.715-722
    • /
    • 1994
  • Thermochromic $Vo_{2}$ thin films for "smart windows" were prepared by electron beam evaporationmethod on a glass substrate and spectral transmittances were examined by spectrophotometer. Substratetemperature of $300^{\circ}C$ and annealing temperature of $400^{\circ}C$ were found to be effective to give athermochromism on $Vo_{2}$ thin film due to the crystallization of the thin film. Furthermore, annealing of$Vo_{2}$ thin film affected the spectral transmittance and reduced the transmittance significantly at wavelengthbelow 500nm.$V_{0.95}W_{0.05}O_{2}$ thin film doped by 5 atomic percent of W showed semiconductor-metal transition around 0$0^{\circ}V_{0.995}W_{0.005}O_{2}$thin film which contains 0.5 atomic percent Sn showed therrnochrornisrn when it was depositedat substrate temperature of $300^{\circ}C$ and annealed at $450^{\circ}C$ for 5 hours in argon gas. The transitiontemperature of the $V_{0.995}W_{0.005}O_{2}$ thin film was found to be about $25^{\circ}C$ and showed some hysterisis. and showed some hysterisis.

  • PDF

Development of depression diagnosis system using EEG signal (뇌파 측정 신호를 이용한 우울증 진단장치 개발)

  • Kim, Kyu-Sung;Jung, Ju-Hyeon;Lee, Woo-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.452-458
    • /
    • 2017
  • In this study, a device was developed for diagnosing depression using EEG signals from July 2016 to June 2017. For normal people, the left alpha rhythm is more activated than the right alpha rhythm, but for the depressed patients, the right alpha rhythm is more activated than the left one. An analog circuit and digital low pass filter were used for noise removal and amplification of EEG, and the Hamming window function was applied to eliminate the signal leakage generated by the fast Fourier transform. To verify the validity of the developed diagnosis system, the EEG of 20 university students in the 3rd and 4th grade with an average age of 24 years was measured. Calculations of the relative value of the left and right alpha rhythm for the depression diagnosis revealed a minimum, maximum, and mean value of 66.7, 113.3, and 92.2, respectively. In addition, 7 out of 20 subjects were between 90 and 95, and those with a higher mean deviation of approximately 20 tended to have mild depression. These results can provide meaningful data for the development of depression treatment equipment by solving the left and right brain asymmetry problem, and it may be applied usefully to diagnose depression after clinical trials on a large number of depressed patients.